| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCRPZ-1000.2 |
| Price | USD 1,700 (FOB) |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | 0.1–10 K/min (programmable) |
| Temperature Accuracy | ±1 °C |
| Sample Dimensions | Max. 50 mm length × 8 mm diameter |
| Measurement Range | ±5 mm |
| Resolution | 0.1 µm |
| Atmosphere Options | N₂, Ar, inert gas, vacuum (−0.1 MPa) |
| Sample Holder Material | Fused quartz |
| Power Supply | 220 V ±10%, 50 Hz |
| Cooling Requirement | External water chiller (max. 100 °C inlet, ≤2 kW heating power) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSCRS-A |
| Price | USD 1,450 (FOB Beijing) |
| Application Field | Electronics & Electrical Equipment |
| Test Specimens | Plastics and Non-Metallic Materials |
| Repeatability Error | ±1 s |
| Flame Power | 50 W (IEC 60695-11-3 / GB/T 5169.16-2008 Compliant) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-AB |
| Price | USD 670 (FOB) |
| Measurement Principle | High-Frequency Resonance Method (Q-meter Based) |
| Frequency Range | Configurable Across Three Models (GCSTD-A / B / C) |
| Test Parameters | Relative Permittivity (εᵣ), Dissipation Factor (tanδ), Q-factor, Capacitance (C), Inductance (L), Series/Parallel Resistance (Rₛ/Rₚ), Characteristic Impedance (Z₀) |
| Sample Types | Solid (disc, Φ38 mm, thickness 0.5–15 mm), Liquid (cell: Φ48 mm × 7 mm depth), Powder (with liquid cell adapter) |
| Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985, ASTM D150, IEC 60250 |
| Operating Environment | 0–40 °C, RH < 80 %, 220 V ±10 %, 50 Hz ±5 % |
| Power Consumption | ≤25 W |
| Net Weight | 7 kg |
| Dimensions (L×W×H) | 380 × 280 × 132 mm |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-AB.2 |
| Price | USD 1,800 (FOB Beijing) |
| Frequency Range | 1 MHz – 100 MHz (typical for AB.2 variant) |
| Measurement Principle | High-Frequency Resonance Method (Q-factor based) |
| Display | Digital LCD with auto-resonance search & frequency lock |
| Test Modes | Solid, Liquid, Powder (with optional cells) |
| Electrode Diameter | Φ38 mm (standard) |
| Sample Thickness | 0.5–15 mm (solids) |
| Liquid Cell Dimensions | Φ48 mm × 7 mm depth |
| Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985, ASTM D150, IEC 60250 |
| Operating Environment | 0–40 °C, RH < 80 %, 220 V ±10 %, 50 Hz ±2.5 Hz |
| Power Consumption | ~25 W |
| Net Weight | ~7 kg |
| Dimensions (L×W×H) | 380 × 280 × 132 mm |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-AB4 |
| Price | USD 1,890 (FOB Beijing) |
| Frequency Range | 10 kHz – 1 MHz (low-frequency band, compliant with GB/T 1409–2006 & ASTM D150) |
| Measurement Parameters | Relative Permittivity (εᵣ), Dissipation Factor (tan δ) |
| Test Method | Automatic Resonant Frequency Sweep with Digital Frequency Locking |
| Electrode Configuration | Solid/liquid/powder-compatible parallel-plate electrodes (Φ38 mm measuring electrode |
| optional liquid cell | Φ48 mm × 7 mm depth) |
| Sample Thickness Range (solid) | 0.5–15 mm |
| Operating Temperature | 0–40 °C |
| Humidity Limit | <80% RH |
| Power Supply | 220 V ±10%, 50 Hz ±2.5 Hz |
| Power Consumption | ~25 W |
| Net Weight | 7 kg |
| Dimensions (L×W×H) | 380 × 280 × 132 mm |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-AB5 |
| Price | USD 1,900 (FOB) |
| Frequency Range | 1 MHz – 70 MHz (typical for AB-series) |
| Measurement Principle | High-Frequency Resonance Method (Series/Parallel Resonant Circuit Analysis) |
| Key Parameters | ε (Dielectric Constant), tanδ (Dissipation Factor), Q-factor, C (Capacitance), L (Inductance), D (Loss Factor) |
| Electrode Configuration | Solid: Φ38 mm parallel-plate electrode, adjustable sample thickness ≥0.5 mm and ≤15 mm |
| Liquid/Powder | Optional Φ48 mm cup (7 mm depth) with Φ38 mm electrode |
| Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985, ASTM D150, IEC 60250 |
| Operating Environment | 0–40 °C, RH <80%, 220 V ±10%, 50 Hz ±2.5 Hz |
| Power Consumption | ~25 W |
| Dimensions (L×W×H) | 380 × 280 × 132 mm |
| Net Weight | ~7 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | GCSTD-CII2 |
| Price | USD 1,150 (FOB Beijing) |
| Standard Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985 |
| Operating Frequency | 45–65 Hz (Auto-Tuned to 50 Hz Nominal) |
| Measurement Modes | Direct Connection, Reverse Connection, External HV Source Mode |
| Output Voltage Range | 2.5 kV, 5 kV, 10 kV (5-step adjustable, integrated HV generator) |
| tanδ Range | 0.00%–99.9%, Resolution: 0.01%, Accuracy: ±(1% × reading + 0.09%) |
| Cx Range | 30 pF–0.3 µF (internal HV), Resolution: 0.1 pF, Accuracy: ±(1.5% × reading + 1 pF) |
| Input Power | 220 V ±10%, 50 Hz, 1.5 kVA |
| Dimensions (L×W×H) | 470 × 320 × 360 mm |
| Weight | 16 kg |
| Ambient Temp | 10–30 °C |
| Relative Humidity | 20–80% RH |
| Display | Large LCD with Chinese menu interface |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-CII3 |
| Price | USD 1,780 (FOB Guangdong) |
| Standard Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985 |
| Measurement Principle | Schering Bridge (High-Voltage AC Bridge) with Variable-Frequency Excitation |
| Test Voltage Range | 2.5 kV – 10 kV (5-step adjustable), Integrated High-Voltage Source & Measurement Unit |
| Measurement Modes | Direct Connection, Reverse Connection, External HV Source Mode |
| Accuracy | tanδ: ±(1% × reading + 0.09%), Cx: ±(1.5% × reading + 1 pF) |
| Resolution | tanδ: 0.01%, Cx: 0.1 pF |
| Sample Compatibility | Solid insulators (Φ50 mm / Φ100 mm / Φ38 mm discs), liquid dielectrics (using standard oil cup), cables, bushings, transformers, current/voltage transformers, power capacitors |
| Operating Environment | 10–30 °C, 20–80% RH |
| Power Input | 220 V ±10%, 50 Hz |
| Dimensions (L×W×H) | 470 × 320 × 360 mm |
| Weight | 16 kg |
| Output Capacity | 1.5 kVA |
| Display | Large-backlight monochrome LCD with Chinese menu interface |
| Protection | Overcurrent trip, arc detection, short-circuit/flashover safeguard |
| Data Output | Built-in thermal printer, RS232 interface for PC connectivity |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GCSTD-CII4 |
| Price | USD 1,250 (FOB Beijing) |
| Operating Frequency | 45–65 Hz (Auto-Tuned to 50/60 Hz) |
| Measurement Principle | Schering Bridge with Digital Phase-Sensitive Detection |
| Display | 320×240 Dot-Matrix LCD with Chinese GUI |
| Input Power | 220 V ±10%, 50/60 Hz |
| Dimensions (L×W×H) | 470 × 320 × 360 mm |
| Weight | 16 kg |
| Output Power | 1.5 kVA |
| Voltage Range | 2.5 kV / 5 kV / 10 kV (Selectable, RMS) |
| Test Modes | Direct Connection, Reverse Connection, External HV Source Mode |
| tgδ Range | 0.00%–99.9%, Resolution: 0.01%, Accuracy: ±(1% of reading + 0.09%) |
| Cx Range | 30 pF–0.3 µF (internal HV), Resolution: 0.1 pF, Accuracy: ±(1.5% of reading + 1 pF) |
| Sample Electrode Diameters Supported | 38 mm, 50 mm, 100 mm |
| Environmental Operating Range | 10–30 °C, 20–80% RH |
| Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-D.1 |
| Price | USD 265 (approx.) |
| Frequency Range | 20 Hz – 2 MHz (10 mHz resolution) |
| Test Signal Level | 10 mV – 5 V (1 mV step) |
| Basic Accuracy | ±0.1% |
| Measurement Speed | up to 200 readings/sec |
| Display | 320×240 dot-matrix LCD |
| Readout Resolution | 5 digits |
| Impedance Parameters | 22 configurable combinations |
| Output Impedance Options | 10 Ω / 25 Ω / 50 Ω / 100 Ω |
| DC Bias Source | Internal ±10 V / 100 mA |
| External DC Bias Support | Up to ±40 A (with dual TH1776 units, optional) |
| Auto Level Control (ALC) | Yes |
| V/I Monitoring | Real-time test signal voltage/current monitoring |
| Graphic Sweep Analysis | Frequency, level, and bias sweeps with on-screen plot |
| Storage | 20 instrument setups |
| Comparator | 10-bin sorting with pass/fail counting |
| Interfaces | USB Device/Host, RS232, GPIB (optional), LAN (optional) |
| Electrode Options | Fixed disk electrodes (Ø38 mm / Ø50 mm, standard: Ø38 mm), liquid cell (15 mL capacity), powder cell (customizable volume) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-D2 |
| Price Range | USD 1,550 – 5,600 |
| Frequency Range | 20 Hz – 2 MHz (10 mHz resolution) |
| Test Signal Level | 10 mV – 5 V (1 mV step) |
| Basic Accuracy | ±0.1% |
| Measurement Speed | Up to 200 readings/s |
| Display | 320 × 240 dot-matrix graphical LCD |
| Resolution | 5-digit |
| Impedance Parameters | 22 configurable combinations |
| DC Bias Source | Internal |
| External DC Bias Current Support | Up to 40 A (with dual TH1776 units, optional) |
| ALP/ALC | Automatic Level Control with V/I monitoring |
| Sweep Modes | 10-point list sweep, graphical analysis |
| Memory | 20 instrument setups |
| Comparator | 10-bin sorting with counting |
| Interfaces | USB Host, RS232, GPIB (optional), Handler I/O |
| Electrode Options | Fixed disk electrodes (Ø38 mm / Ø50 mm standard), liquid cell (15 mL capacity), powder-specific electrode kits |
| Sample Types | Solids, liquids, powders, pastes, regular or irregular geometries |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-D3 |
| Price | USD 1,850 (FOB Beijing) |
| Frequency Range | 20 Hz – 2 MHz (10 mHz resolution) |
| Test Signal Level | 10 mV – 5 Vrms (1 mV step) |
| Basic Accuracy | ±0.1% |
| Measurement Speed | Up to 200 readings/sec |
| Display | 320×240 dot-matrix LCD |
| Impedance Parameters | 22 configurable combinations (e.g., C–D, C–Q, L–Q, R–X, Z–θ) |
| Electrode Options | Fixed parallel-plate electrodes (Ø38 mm standard, Ø50 mm optional), liquid cell (15 mL capacity), powder cell (customizable volume), and non-contact electrode module |
| Sample Types | Solids (flat or irregular), liquids, powders, pastes |
| DC Bias | Internal ±10 V / 100 mA |
| ALR/ALC | Automatic Level Control with V/I monitoring |
| Scan Modes | 10-point list sweep, graphical frequency/amplitude sweep |
| Memory | 20 instrument setups |
| Interface | USB Host/Device, RS232, GPIB (optional), LAN (optional) |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150–18, IEC 60250:2019 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-D35 |
| Price | USD 140 (approx.) |
| Frequency Range | 20 Hz – 2 MHz (10 mHz resolution) |
| Test Signal Level | 10 mV – 5 V (1 mV step) |
| Basic Accuracy | ±0.1% |
| Measurement Speed | up to 200 readings/sec |
| Display | 320×240 dot-matrix LCD |
| Resolution | 5-digit |
| Impedance Parameters | 22 configurable combinations |
| DC Bias Source | Built-in |
| External DC Current Bias | Up to 40 A (with dual TH1776 units, optional) |
| ALR/ALC | Automatic Level Control |
| V/I Monitoring | Real-time test signal monitoring |
| Graphical Sweep Analysis | Yes |
| Internal Memory | 20 instrument setups |
| Comparator | 10-bin sorting with counting |
| Interfaces | USB Host, RS232, GPIB (optional), Handler I/O |
| Operating Language | English / Chinese selectable |
| Firmware Update | Via USB HOST |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCSTD-F.4 |
| Frequency Range | 10 Hz – 10 MHz (typical for F-series) |
| Electrode Configuration | Coaxial Cylindrical (316 Stainless Steel Outer/Inner Cylinders) |
| Electrode Spacing | Fixed via Six Nylon Set Screws |
| Material Compatibility | Stainless Steel / Nylon / PTFE |
| Cleaning Protocol | Solvent Immersion (Acetone/Ethanol) + Ultrasonic Bath |
| Calibration Support | Two-Point Capacitance-Based Calibration (Air & Standard Liquid Reference) |
| Compliance Context | Designed for ASTM D150, IEC 60250, and ISO 18738-compliant dielectric characterization workflows |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-F1 |
| Price | USD 1,850 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | GCSTD-F3 |
| Price | USD 1,550 (approx.) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-F5 |
| Price | USD 1,280 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GCSTD-FI |
| Price | USD 1,920 (approx. based on ¥13,700 at 7.14 exchange rate) |
| Measurement Principle | Capacitance-based dielectric spectroscopy at fixed frequency |
| Test Frequency | 10 kHz sinusoidal excitation |
| Electrode Type | External coaxial cylindrical electrode (316 stainless steel outer/inner cylinders, nylon spacers) |
| Measurement Ranges | 1–20 and 1–200 (dimensionless relative permittivity, εᵣ) |
| Accuracy | ±2% of reading |
| Repeatability & Linearity | ±0.2% of full scale |
| RMS Excitation Voltage | ~7 V (range 1–20), ~0.7 V (range 1–200) |
| Compliance Standards | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-FI.2 |
| Test Frequency | 10 kHz Sinusoidal Signal |
| Measurement Ranges | 1–20 and 1–200 (dimensionless relative permittivity scale) |
| Accuracy | ±2% |
| Repeatability & Linearity | ±0.2% RMS |
| Electrode Type | External coaxial cylindrical probe (316 stainless steel outer/inner cylinders, nylon spacers, PTFE-insulated) |
| Excitation Voltage | ~7 V RMS (range 1–20), ~0.7 V RMS (range 1–200) |
| Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-FI.6 |
| Price | USD 1,950 (FOB Beijing) |
| Measurement Principle | Two-electrode capacitance bridge method at fixed frequency |
| Frequency | 10 kHz sinusoidal excitation |
| Measurement Ranges | 1–20 and 1–200 (dimensionless relative permittivity, εᵣ) |
| Accuracy | ±2% of reading |
| Repeatability & Linearity | ±0.2% of full scale |
| Electrode Type | External coaxial cylindrical probe (316 stainless steel outer/inner cylinders, nylon spacers, PTFE-insulated) |
| Excitation Voltage RMS | ~7 V (range 1–20), ~0.7 V (range 1–200) |
| Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-FI.7 |
| Frequency Range | 10 kHz sinusoidal excitation |
| Measurement Ranges | 1–20 and 1–200 (dimensionless relative permittivity scale) |
| Accuracy | ±2% |
| Repeatability & Linearity | ±0.2% RMS |
| Electrode Type | External coaxial cylindrical probe (316 stainless steel outer/inner cylinders, nylon spacers, PTFE-insulated) |
| Excitation Amplitude | ~7 V RMS (range 1–20), 0.7 V RMS (range 1–200) |
| Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-FI2 |
| Price | USD 1,950 (FOB Beijing) |
| Measurement Principle | Two-Terminal Capacitance-Based Dielectric Spectroscopy at Fixed 10 kHz |
| Compliance | GB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985 |
| Accuracy | ±2% of reading |
| Repeatability & Linearity | ±0.2% |
| Electrode Type | External coaxial cylindrical electrode (316 stainless steel outer/inner cylinders, nylon spacers, PTFE-insulated) |
| Excitation Signal | 10 kHz sine wave, RMS amplitude selectable: ~7 V (range 1–20), ~0.7 V (range 1–200) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | GCTKK-700 |
| Power Rating | 1.5 kW |
| Rated Voltage | 220 V / 50 Hz |
| Maximum Operating Temperature | 700 °C |
| Thermocouple Type | K-type (0–800 °C) |
| Gas Flow Sensor Range | 0–250 L/h, Accuracy: ±4% FS |
| Pressure Sensor Range | 0–1 MPa, Accuracy Class ≥ 1.5 |
| Sample Vibration Frequency | 1 rpm |
| Sample Dimensions | Ø50 mm ±1 mm × 60 mm ±1 mm |
| Chamber Uniformity Zone | Stable isothermal zone at 700 °C with ±1 °C stability (PID-controlled) |
| External Dimensions | 750 mm (L) × 700 mm (W) × 1600 mm (H) |
| Net Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GCTKK-700b |
| Price | USD 450 (FOB Beijing) |
| Rated Power | 1.5 kW |
| Rated Voltage | 220 V / 50 Hz |
| Maximum Operating Temperature | 700 °C |
| Thermocouple Type | K-type (0–800 °C) |
| Gas Flow Range | 0–250 L/h (Accuracy: ±4%) |
| Pressure Sensor Range | 0–1 MPa (Accuracy Class ≥1.5) |
| Sample Vibration Frequency | 1 rpm |
| Sample Dimensions | Ø50 mm ±1 mm × 60 mm ±1 mm |
| Chamber Uniformity Zone | ≥100 mm (±1 °C at 700 °C) |
| Equipment Dimensions (L×W×H) | 750 × 700 × 1600 mm |
| Net Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKP-700 |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable, up to 10 °C/min (typical) |
| Temperature Accuracy | ±1 °C (after thermal equilibrium) |
| Displacement Range | 0–1 mm |
| Displacement Resolution | ±0.001 mm |
| Sample Dimensions | (i) Ø50 mm × 60 mm |
| Atmosphere Control | Pressure range 0–50 kPa (gauge), compatible with inert, reducing, or vacuum environments |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 1.7 kW |
| Thermal Sensor | K-type thermocouple (0–1000 °C, Class 0.1 accuracy) |
| Gas Flow Control | 0–80 L/min (mass flow controller) |
| Instrument Dimensions | 700 × 810 × 1150 mm (W × D × H) |
| Net Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKP-700b |
| Price | USD 1,280 (FOB Beijing) |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable, 0.1–10 °C/min (standard configuration) |
| Temperature Accuracy | ±1 °C (after thermal equilibrium, per ASTM E228 calibration protocol) |
| Displacement Range | 0–1 mm |
| Measurement Resolution | ±0.001 mm |
| Sample Dimensions | (i) Ø50 mm × 60 mm cylindrical |
| Atmosphere Control | Pressure range 0–50 kPa (gauge), compatible with inert (N₂, Ar), reducing (5% H₂/95% N₂), or vacuum conditions |
| Power Supply | 220 V AC / 50 Hz / 1.7 kW |
| Thermocouple | Type K, 0–1000 °C, Class 0.1 accuracy |
| Gas Flow Control | Mass flow controller, 0–80 L/min |
| Dimensions (W×D×H) | 700 mm × 810 mm × 1150 mm |
| Net Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCTKP-700C |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable (0–10 °C/min typical) |
| Displacement Range | 0–1 mm |
| Displacement Resolution | ±0.001 mm |
| Sample Dimensions | Ø50 mm × 60 mm or ≥5 mm cross-section × ≥50 mm length |
| Atmosphere Control | 0–50 kPa (gauge), compatible with inert/N₂/air/vacuum |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 1.7 kW |
| Thermocouple | Type K (0–1000 °C, Class 0.1 accuracy) |
| Gas Flow Meter | 0–80 L/min |
| Dimensions (W×D×H) | 810 × 700 × 1150 mm |
| Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKP-700H |
| Price | USD 1,280 (FOB Beijing) |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable, 0.1–20 °C/min (standard) |
| Temperature Accuracy | ±1 °C (after stabilization, per ASTM E228 calibration protocol) |
| Displacement Range | 0–1 mm |
| Measurement Resolution | ±0.001 mm |
| Sample Dimensions | (i) Ø50 mm × 60 mm cylindrical |
| Atmosphere Control | Pressure range 0–50 kPa (gauge), compatible with inert (N₂, Ar), oxidizing (air), or reducing (5% H₂/95% N₂) environments |
| Power Supply | 220 V AC, 50 Hz, 1.7 kW |
| Thermocouple | Type K, 0–1000 °C, Class 0.1 accuracy |
| Gas Flow Control | Digital mass flow controller, 0–80 L/min |
| Unit Dimensions | 700 × 810 × 1150 mm (W × D × H) |
| Net Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKY-100KN |
| Maximum Test Load | 100 kN |
| Compliance | GB/T 3074.1–2021 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCWDS-5K |
| Instrument Type | Electromechanical Universal Testing Machine |
| Maximum Test Load | 5 kN |
| Accuracy Class | Class 0.5 |
| Frame Type | Portal-Style, Floor-Standing |
| Load Cell Accuracy | ±1% of reading (2–100% FS) |
| Force Resolution | 1/300,000 of full scale |
| Displacement Resolution | 0.01 mm |
| Crosshead Speed Range | 0.05–850 mm/min |
| Speed Accuracy | ±1% of set value |
| Effective Tensile Stroke | 650 mm |
| Effective Test Width | 600 mm |
| Dimensions (W×D×H) | 695 × 580 × 2400 mm |
| Weight | 300 kg |
| Power Supply | 220 V, 50 Hz, 1 kW |
| Control System | SmartTest™ Digital Controller with Windows-Based Software |
| Compliance Standards | GB/T 228.1, ISO 6892-1, ASTM E4, ASTM E8, ASTM D638, ASTM D790, JIS Z2241, DIN 50125 |