GuanCe Instruments
Filter
Showing 181–210 of 329 results
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCWP-A1 |
| Price | USD 1,280 (FOB Beijing) |
| Electrode Diameter | 6 mm |
| Number of Electrodes | 4 |
| Electrode Shielding | Inner layer — 304 stainless steel |
| Measurement Channels | 4-channel simultaneous testing |
| Frequency Switching | Programmable sample switching interval |
| Operating Modes | Manual and automated test sequences |
| Data Export | Raw impedance/dielectric data (CSV/Excel), real-time Lissajous & Cole–Cole plots, printable ASTM-compliant test reports |
| Measurement Frequency Range | Compatible with Agilent 4294A Precision Impedance Analyzer (40 Hz – 110 MHz) |
| Temperature Range | −180 °C to +500 °C |
| Heating Rate | 0.5–2.5 °C/min (programmable) |
| Signal Cabling | Silver-plated copper low-temperature shielded cables |
| Enclosure Material | Q235 carbon steel chassis with high-temp epoxy powder coating |
| Power Supply | AC 220 V, 50 Hz, 2 kW |
| Reference Impedance Analyzer | Agilent 4294A (or equivalent IEC 60250–compliant bridge) |
| Environmental Requirements | Avoid dusty, high-vibration, direct-sunlight, or corrosive-gas environments |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCWP-A2 |
| Frequency Range | 100 Hz – 10 MHz (as defined by integrated Agilent 4294A impedance analyzer) |
| Electrode Configuration | Four-channel coaxial shielded electrodes (6 mm diameter) |
| Temperature Range | −180 °C to +500 °C |
| Heating Rate | 0.5–2.5 °C/min |
| Input Power | AC 220 V, 50 Hz, 2 kW |
| Shielding | Inner sleeve — AISI 304 stainless steel |
| Data Interface | Silver-plated copper low-temperature shielded cables |
| Enclosure | Q235 carbon steel chassis with high-temp epoxy powder coating |
| Compliance | Designed for ASTM D150, IEC 60250, and ISO 257-3 environments |
| Data Output | Raw time-domain/frequency-domain datasets, Lissajous plots, Cole-Cole diagrams, ε′/ε″ vs. frequency & temperature, printable test reports per GLP-compliant template |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCWP-A3 |
| Supply Voltage | AC 220 V, 50 Hz |
| Power Consumption | 2 kW |
| Electrode Diameter | 6 mm |
| Number of Electrodes | 4 (quad-channel) |
| Electrode Housing | Inner layer — 304 stainless steel |
| Temperature Range | −180 °C to +500 °C |
| Heating Rate | 0.5–2.5 °C/min |
| Measurement Frequency Range | As specified by integrated impedance analyzer |
| Impedance Analyzer | Keysight 4294A (or equivalent high-precision LCR bridge) |
| Data Cable | Silver-plated copper, cryogenic-grade shielded cable |
| Enclosure Material | Q235 carbon steel with high-temperature epoxy powder coating |
| Operating Environment | Low-dust, low-vibration, non-corrosive atmosphere |
| Data Output | Raw measurement files (CSV/ASCII), real-time Lissajous & Cole-Cole plots, printable test reports |
| Test Modes | Manual and programmable automated sequence |
| Sample Switching Interval | User-definable time-based channel selection |
| Brand | GuanCe Instruments |
|---|---|
| Model | GCWP-A4 |
| Measurement Principle | Precision Impedance Bridge (Agilent 4294A-based) |
| Electrode Configuration | Quadruple-channel guarded electrode system (4 × 6 mm stainless-steel electrodes) |
| Shielding | Dual-layer coaxial shielding — inner tube: 304 stainless steel, outer jacket: PTFE |
| Temperature Range | −180 °C to +500 °C |
| Heating Rate | 0.5–2.5 °C/min |
| Data Interface | Silver-plated copper low-noise cryogenic shielded cables |
| Compliance | Designed for ASTM D150, IEC 60250, and ISO 257-1/2 environments |
| Power Supply | AC 220 V, 50 Hz, 2 kW |
| Enclosure | Q235 steel chassis with high-temp epoxy powder coating |
| Operating Environment | Requires low-vibration, low-dust, EMI-shielded laboratory |
| Data Output | Raw impedance spectra (.csv), loss tangent (tan δ) vs. frequency/temperature plots, printable test reports with timestamped metadata |
| Brand | GuanCe Instruments |
|---|---|
| Model | GCWP-A5 |
| Measurement Principle | Precision Impedance Bridge (Agilent 4294A-based) |
| Electrode Configuration | Quadruple 6-mm Diameter Electrodes |
| Temperature Range | −180 °C to +500 °C |
| Heating Rate | 0.5–2.5 °C/min |
| Frequency Range | Dependent on Integrated Agilent 4294A Impedance Analyzer |
| Electrode Shielding | 304 Stainless Steel Inner Sleeve / PTFE Outer Jacket |
| Data Interface | Silver-Plated Copper Low-Temperature Shielded Cables |
| Compliance | ASTM D150, IEC 60250, ISO 17025 (when operated in accredited lab environment) |
| Power Supply | AC 220 V, 50 Hz, 2 kW |
| Enclosure | Q235 Steel with High-Temperature Powder Coating |
| Operating Environment | Dust-Free, Low-Vibration, EMI-Shielded Laboratory |
| Data Output | Raw CSV Export, Real-Time Lissajous & Bode Plots, PDF Report Generation |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCYSBX-1 |
| Price | USD 1,770 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCYSBX-1 |
| Price | USD 3,500 (FOB Beijing) |
| Standard Compliance | GB/T 6669–2008 / ISO 1856:2000 |
| Specimen Dimensions | 50 mm × 50 mm × 25 mm |
| Capacity | 20 specimens per test cycle |
| Compression Plates | Parallel stainless-steel plates with adjustable spacing and clamping mechanism |
| Calibration Spacers | 12.5 mm (50% compression), 6.25 mm (75%), and 2.5 mm (90%) — 4 pieces each |
| Glass Cover Slides | 55 mm × 55 mm × 1.5 mm |
| Temperature-Controlled Oven Range | 0–300 °C |
| Oven Temperature Accuracy | ±1 °C |
| Oven Power Supply | 220 V AC, 50 Hz |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | GCZMD-10 |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Compact) |
| Sample Types | Solids (bulk, granular, powdered) & Liquids |
| Density Range | 0–20 g/cm³ |
| Maximum Sample Weight | 5 g |
| Density Resolution | 0.01 g/cm³ |
| Density Accuracy | ±0.1% (relative), <0.5% RSD per ASTM D5550 |
| Repeatability | ≤0.01 g/cm³ (standard deviation over ≥5 replicates) |
| Minimum Sample Volume | 0.1 mL (liquids) / 0.1 g (solids) |
| Temperature Operating Range | 0–40 °C |
| Display | High-contrast 7-inch capacitive touchscreen |
| Data Interface | RS-485, RJ45 Ethernet, USB host (for U-disk logging), built-in thermal printer (TMS variant) |
| Pressure Control | Dual-stage precision pressure regulation (max. 2.0 bar) |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Cycle Time | ~4 min per analysis (configurable via embedded script) |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions (W×D×H) | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Pressure Sensors | 24-bit ADC acquisition, calibrated transducers |
| Compliance | Designed to support GLP/GMP data integrity requirements (audit trail enabled in PNS firmware version) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GCZMD-10 |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Not Portable — Corrected per Technical Specification) |
| Sample Type | Solids & Liquids |
| Density Range | 0.1–20 g/cm³ |
| Maximum Sample Weight | 20 g |
| Density Accuracy | ±0.1% (Relative) |
| Display | Digital LCD Touchscreen |
| Operating Temperature Range | 0–40 °C |
| Repeatability | ≤0.3% RSD (n ≥ 3) |
| Volume Resolution | 0.01 mL |
| Minimum Sample Volume | 0.1 mL |
| Test Time | ~4 min per run |
| Pressure Control | Up to 2.0 bar (adjustable) |
| Analysis Gas | Helium (recommended), N₂ (optional, requires calibration adjustment) |
| Data Interface | RS485, RJ45 Ethernet, USB port for U-disk storage |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Compliance | ASTM D5550, ISO 12154, USP <699>, GLP-ready data logging |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | GCZMD-10a |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Not Portable — corrected per technical specification: 4.6 kg, 410×320×155 mm, RS485/RJ45 interface) |
| Sample Types | Solids (bulk, granular, powdered) and Liquids |
| Density Range | 0–20 g/cm³ |
| Maximum Sample Mass | 5 g |
| Density Accuracy | ±0.1% of reading |
| Display | High-contrast TFT touchscreen with handwriting input |
| Operating Temperature | 0–40 °C |
| Repeatability | ≤0.01 g/cm³ (RSD 0.1–0.3% over n≥3 measurements) |
| Resolution | 0.01 g/cm³ |
| Minimum Sample Volume | 0.1 mL (solids) / 0.1 g (liquids) |
| Measurement Principle | Gas Pycnometry (He or N₂ displacement, based on Boyle’s Law) |
| Measurement Time | ~4 min per analysis (configurable via script) |
| Pressure Range | 1.3–2.0 bar (user-selectable) |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Data Output | Real-time process logging, USB flash drive storage, RS485 & RJ45 Ethernet connectivity, optional thermal printer (TMS variant) |
| Power Supply | AC 220 V / 50 Hz, 28 W |
| Dimensions | 410 × 320 × 155 mm |
| Weight | 4.6 kg |
| Sensor Resolution | 24-bit ADC |
| Compliance | ASTM D5550, ISO 12154, USP <699>, GLP-ready audit trail support (via software log export) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | GCZMD-10c |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Compact) |
| Sample Compatibility | Solids & Liquids |
| Density Range | 0–20 g/cm³ |
| Maximum Sample Mass | 5 g |
| Density Accuracy | ±0.1% (relative) |
| Display | High-Resolution TFT Touchscreen |
| Operating Temperature Range | 0–40 °C |
| Repeatability | ≤0.01 g/cm³ (RSD ≤0.1–0.3%) |
| Resolution | 0.01 g/cm³ |
| Minimum Sample Volume | 0.1 mL |
| Measurement Principle | Gas Expansion Displacement (Helium Pycnometry) |
| Test Time | ~4 min per cycle |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Working Pressure | 1.3 bar (max. 2.0 bar) |
| Recommended Analysis Gas | He (N₂ optional, requires calibration adjustment) |
| Pressure Control Valve | 154N-050A-C (U.S.-sourced) |
| Solenoid Valve | CFVB25-Z-O-B2C-3 (Japan-sourced) |
| Data Interface | RS485, RJ45 Ethernet, USB Host (U-disk storage), Built-in Thermal Printer (TMS variant) |
| Input Method | Capacitive Touchscreen with Handwriting Support |
| ADC Resolution | 24-bit |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions (W×D×H) | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Calibration Standards Supplied | PVC, Al, Cu reference materials |
| Software Architecture | Embedded C-based real-time OS with scriptable workflow engine |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | GCZMD-10d |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Compact) |
| Sample Compatibility | Solids & Liquids |
| Density Range | 0–20 g/cm³ |
| Maximum Sample Mass | 5 g |
| Density Resolution | 0.01 g/cm³ |
| Density Accuracy | ±0.1% (relative) |
| Repeatability | ≤0.01 g/cm³ (RSD 0.1–0.3%) |
| Minimum Sample Volume | 0.01 mL |
| Temperature Operating Range | 0–40 °C |
| Display | High-contrast 7-inch TFT capacitive touchscreen |
| Pressure Control | Dual-stage regulated up to 2.0 bar (default test pressure: 1.3 bar) |
| Gas Options | Helium (recommended), Nitrogen (user-specified) |
| Measurement Principle | Gas Pycnometry (Helium Displacement, ASTM D5550 / ISO 12154 compliant) |
| Test Time | ~4 minutes per run (configurable via script) |
| Data Interface | RS485, RJ45 Ethernet, USB host (U-disk storage), integrated thermal printer (TMS variant) |
| ADC Resolution | 24-bit |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 28 W |
| Dimensions (W×D×H) | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCZRS-A |
| Application Field | Electrical & Electronic Equipment |
| Heating Element | Ni80/Cr20 alloy wire (Φ4 mm) |
| Repeatability Error | ±1°C |
| Intended Use | Flammability assessment of insulating materials, engineering plastics, and other solid combustible materials |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-250.1 |
| Price | USD 2,100 (approx.) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-250a |
| Price | USD 410 (converted from ¥2888 at 1 USD ≈ ¥7.0) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-250B |
| Price | USD 410 (converted from ¥2888 at 1 USD = ¥7.03) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-250c |
| Price | USD 410 (converted from ¥2888 at 1 USD = ¥7.0) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-250D |
| Price | USD 1,800 (FOB Beijing) |
| Temperature Range | Ambient to 250 °C |
| Sample Chamber Dimensions | 600 mm (L) × 400 mm (W) × 400 mm (H) |
| Enclosure Material | Powder-Coated Steel |
| Input Power | 220 V AC, 50 Hz, Three-Phase |
| Operating Humidity | <50 % RH |
| Ambient Temp | 22–27 °C |
| Compressed Air Supply | 0.5 MPa (clean, oil-free) |
| Positive-Pressure Purge Air | 0.05 MPa (explosion-proof inert gas optional) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-500.2 |
| Price | USD 1,700 (approx.) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-500.3 |
| Price | USD 2,200 (FOB) |
| Temperature Range | −160 °C to +500 °C |
| Temperature Stability | ±0.5 °C |
| Electrode Material | Brass |
| Electrode Diameter | 25 mm |
| Test Frequency Range | 20 Hz – 2 MHz |
| Heating Method | Electric Resistance Heating |
| Cooling Method | Liquid Nitrogen Cryogenic Cooling |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150, IEC 60250 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-500b |
| Price | USD 1,850 (FOB) |
| Temperature Range | −160 °C to +500 °C |
| Temperature Stability | ±0.5 °C |
| Heating Method | Electric Cartridge Heater |
| Cooling Method | Liquid Nitrogen Cryogenic System |
| Electrode Material | Brass |
| Electrode Diameter | 25 mm |
| Test Frequency Range | 20 Hz – 2 MHz |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150, IEC 60250 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-500C |
| Price | USD 2,100 (FOB) |
| Temperature Range | −160 °C to +500 °C |
| Temperature Stability | ±0.5 °C |
| Cooling Method | Liquid Nitrogen |
| Heating Method | Resistive Cartridge Heating |
| Electrode Material | Brass |
| Electrode Diameter | 25 mm |
| Test Frequency Range | 20 Hz – 2 MHz |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-500d |
| Price | USD 1,400 (approx.) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW-500e |
| Price | USD 980 (FOB) |
| Temperature Range | −160 °C to +500 °C |
| Temperature Stability | ±0.5 °C |
| Heating Method | Electric Cartridge Heater |
| Cooling Method | Liquid Nitrogen Cryogenic Cooling |
| Electrode Material | Brass |
| Electrode Diameter | 25 mm |
| Test Frequency Range | 20 Hz – 2 MHz |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150, IEC 60250 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDW500.3 |
| Price | USD 1,980 (FOB) |
| Temperature Range | −160 °C to +500 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Cooling Method | Liquid Nitrogen |
| Heating Method | Resistive Electric Heating |
| Electrode Material | Brass |
| Electrode Diameter | 25 mm |
| Test Frequency Range | 20 Hz – 2 MHz |
| Brand | GuanCe Instruments |
|---|---|
| Model | GEST-1214 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 1×10⁻¹⁶ A to 2×10⁻⁴ A |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Accuracy | ±1% (≤1×10¹⁰ Ω), ±5–10% (>1×10¹⁰ Ω) |
| Display | Digital LCD |
| Power Supply | 220 V AC / 50 Hz |
| Power Consumption | 100 W |
| Dimensions (L×W×H) | 300 mm × 300 mm × 150 mm |
| Weight | ~5 kg |
| Standard Electrode | Three-electrode system for solid samples ≥80 mm diameter |
| Compliance | Designed for ASTM D257, IEC 62631-3-1, GB/T 1410, ISO 3915 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GEST-121A.22 |
| Price | USD 2,100 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GEST-121A1a |
| Price | USD 280 (approx.) |
| Minimum Current Resolution | 1×10⁻¹⁶ A |
| Temperature Range | −40 °C to +250 °C |
| Heating Rate | 0.5–10 °C/min |
| DC Voltage Ranges | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V |
| Electrode Diameter | 10 mm |
| Sample Stage | Motorized Vertical Positioning |
| Heating Method | Resistive Wire Heater |
| Cooling Method | Compressor-Based Active Cooling |
| Thermal Bath Medium | Dimethyl Silicone Oil (2 cSt, 10 L capacity) |
| Data Acquisition | PC-controlled real-time acquisition with dynamic curve visualization |
| Data Export | Excel (.xlsx) format with timestamped metadata and audit-ready report generation |
| Fully Automated Test Sequence | Parameter-defined start/stop temperature, dwell time, ramp rate, and bias voltage |
| Heating Power | 1500 W |
| Net Weight | 100 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GEST-121A2 |
| Price | USD 265 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GEST-121Ac |
| Price | USD 980 (FOB Beijing) |
| Heating Method | Electric Resistance Heating |
| Cooling Method | Liquid Nitrogen Cryogenic Cooling |
| Temperature Control Accuracy | ±0.5 °C |
| Maximum Operating Temperature | 400 °C |
| Minimum Operating Temperature | −50 °C |
