GuanCe Instruments
Filter
Showing 1–30 of 329 results
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | DW-1000 |
| Price | USD 2,800 (FOB Beijing) |
| Max Output Current | 1000 A AC |
| Temperature Channels | 2 independent acquisition + 1 closed-loop control |
| Control System | Siemens S7-1200 PLC + 15″ HMI touchscreen |
| Power Supply | 380 VAC ±10%, 50 Hz ±0.5 Hz, 20 kW |
| Ambient Operating Range | −30–40 °C, ≤85% RH, ≤1000 m altitude |
| Enclosure Dimensions (L×W×H) | 1400 × 1150 × 1700 mm |
| Weight | 500 kg |
| Protection | Overcurrent, overtemperature, grounding fault, voltage anomaly, seismic-rated (horizontal 3 m/s² / vertical 1.5 m/s²) |
| Grounding Resistance | ≤4 Ω |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GEST-20042F |
| Compliance | GB/T 20042.6–2011, GB/T 20042.7–2014 |
| Measurement Modes | Through-plane (2-probe) & In-plane (4-probe) |
| Electrode Diameter | 50 mm gold-plated |
| Control Interface | 10-inch industrial touchscreen HMI |
| Loading Actuation | Servo-motor-driven precision force application |
| Data Output | Real-time pressure, compressive strain, voltage, current, resistance, resistivity (mΩ·cm, Ω·cm, kΩ·cm), conductivity (S/cm, S/m) |
| Test Protocols | Constant-force, constant-pressure, stepwise gradient (force/pressure/strain), compression-ratio control |
| Data Export | CSV via USB |
| Auto-reset | Yes |
| Reporting | On-screen preview + thermal printout |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | ZKMD-6609b |
| Instrument Type | Bulk Density Tester (for Powders) |
| Application | Bulk density measurement of free-flowing and cohesive particulate solids (e.g., carbon fiber powders, metal powders, pharmaceutical granules) |
| Construction | Stainless steel |
| Portability | Benchtop (non-portable, fixed-position design) |
| Compliance Basis | ASTM D1895–23, ISO 697–2022, USP <616>, GB/T 1479.1–2011 |
| Sample Form | Dry, free-flowing or slightly cohesive solid powders only |
| Liquid Measurement Capability | None |
| Density Range | 0.1–5.0 g/cm³ (typical for powder bulk density applications) |
| Repeatability | ±0.01 g/cm³ (under controlled environmental conditions per ISO 29553) |
| Brand | Guance Instruments |
|---|---|
| Model | GCZMD-10b |
| Origin | Beijing, China |
| Instrument Type | True Density Analyzer |
| Design | Portable |
| Sample Type | Solids and Liquids |
| Density Range | 0.1–20 g/cm³ |
| Maximum Sample Weight | 20 g |
| Density Resolution | 0.01 g/cm³ |
| Density Accuracy | ±0.1 g/cm³ (typical repeatability ≤0.3% RSD) |
| Measurement Principle | Gas Expansion Displacement (Helium Pycnometry) based on Boyle’s Law (PV = nRT) |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Measurement Time | ~4 min per run |
| Operating Temperature | 0–40 °C |
| Pressure Range | 1.3–2.0 bar |
| Recommended Analysis Gas | Helium (N₂ compatible with calibration adjustment) |
| Data Interface | RS485, RJ45 Ethernet, USB for U-disk storage |
| Display | Touchscreen with handwriting input |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Minimum Sample Mass | 0.1 g |
| Data Output | Real-time process logging + CSV export via USB |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCCLC-AII |
| Impact Energy Range | 50–300 J |
| Impact Velocity | 2–5.5 m/s |
| Pendulum Torque (Impact Constant) | 15 N·m |
| Load Cell Capacity | 16 kN |
| Maximum Lifting Height | 1500 mm |
| Temperature Chamber Range | −40 °C to +100 °C |
| System Sampling Rate | 2 MHz |
| A/D Resolution | 16-bit |
| Frequency Response | 500 kHz |
| Dynamic Test Error | <2% |
| Overall Dimensions (w/o chamber) | 850 × 1700 × 3300 mm |
| Net Weight | 1200 kg |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDH-B6 |
| Price | USD 2,350 (approx.) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Standards Compliance | GB/T 1411-2002, IEC 61621:1997, ASTM D495, IEC 149, UL 746A |
| Rated Test Voltage | 12.5 kV |
| Voltage Accuracy | ±1% |
| Current Range | 10–40 mA (selectable steps) |
| Current Control Accuracy | ±3% |
| Current Measurement Accuracy | ±1.5% |
| Arc On/Off Timing Error | < ±1 ms |
| Electrode Force | 0.5 ± 0.05 N |
| Electrode Material | Tungsten Rod |
| Electrode Spacing | 6.35 ± 0.1 mm (IEC), 6.0 ± 0.1 mm (ASTM) |
| Input Power | 220 V AC, 50 Hz |
| Transformer Capacity | 3 kVA |
| Output Voltage Range | 0–17.5 kV AC |
| Operating Environment | 23 ± 2 °C, 50 ± 5 % RH |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GEST-20042I |
| Price | USD 1,550 (FOB Beijing) |
| Brand | Guance Instruments |
|---|---|
| Model | GCFTDZ-I |
| Origin | Beijing, China |
| Measurement Principle | Two-Point Probe DC Resistivity |
| Max Applied Pressure | 3.9 MPa |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Force Range | 0–5 kN |
| Force Accuracy | ±0.5% FS |
| Resistivity Range | 10⁻⁶ – 10⁵ Ω·m |
| Voltage Resolution | 1 µV (at 2 mV range) |
| Current Sources | 10 µA to 10 A (8 ranges) |
| Current Accuracy | ±0.5% |
| Voltage Accuracy | ±0.1% |
| Thickness Resolution | ±1 µm |
| Control Interface | 10-inch Industrial Touchscreen (Siemens PLC-based) |
| Compliance | GB/T 24521–2018 |
| Data Output | Thermal Printer + USB Export (CSV) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCFTDZ-I |
| Pressure Range | 0–5 kN (up to 3.9 MPa) |
| Force Accuracy | ±0.5% FS |
| Resistivity Measurement Range | 10⁻⁶ – 10⁵ Ω·m |
| Current Sources | 10 μA – 10 A (8 ranges) |
| Voltage Resolution | 100 nV (2 mV range) |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Compression Thickness Resolution | ±1 μm |
| Data Output | USB export + thermal printer |
| Control Interface | 10-inch industrial touchscreen with Siemens PLC |
| Compliance | GB/T 24521–2018 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-D4 |
| Price | USD 2,600 (FOB Beijing) |
| Frequency Range | 20 Hz – 2 MHz (10 mHz resolution) |
| Test Signal Level | 10 mV – 5 Vrms (1 mV step) |
| Basic Accuracy | ±0.1% |
| Measurement Speed | Up to 200 readings/sec |
| Display | 320×240 dot-matrix graphical LCD |
| Resolution | 5-digit |
| Impedance Parameters | 22 configurable combinations (e.g., C–D, C–Q, L–Q, R–X, Z–θ) |
| Electrode Options | Fixed parallel-plate electrodes (Ø38 mm / Ø50 mm standard), liquid cell (15 mL capacity), powder-specific electrode kits |
| Sample Forms | Solid sheets, films, pellets, liquids, pastes, powders, irregular geometries |
| Test Methods | Contact (for flat, uniform-thickness specimens) and Non-contact (capacitive coupling for rough or curved surfaces) |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150–18, IEC 60250:2015 |
| DC Bias | Internal ±10 V / 100 mA |
| ALA/ALC | Automatic Level Control with V/I monitoring |
| Scan Modes | 10-point frequency, voltage, or bias list sweep |
| Data Storage | 20 instrument setups |
| Interface | USB Host/Device, RS232, GPIB (optional), LAN (optional) |
| Firmware Update | Via USB flash drive |
| Language | English / Chinese switchable |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCWP-A |
| Electrode Diameter | 6 mm (4 electrodes) |
| Electrode Shielding | Inner layer – 304 stainless steel |
| Channel Configuration | Quad-channel simultaneous measurement |
| Frequency Switching | Programmable sample switching interval |
| Operating Modes | Manual and automated sequence control |
| Data Export | Raw data export (CSV/Excel), real-time curve plotting, printable test reports |
| Frequency Range | Determined by integrated Agilent 4294A Precision Impedance Analyzer |
| Temperature Range | −180 °C to +500 °C |
| Heating Rate | 0.5–2.5 °C/min (programmable) |
| Cryogenic Cabling | Silver-plated copper shielded cables |
| Enclosure | Q235 carbon steel chassis with high-temp epoxy powder coating |
| Power Supply | AC 220 V, 50 Hz, 2 kW |
| Core Impedance Analyzer | Agilent 4294A |
| Environmental Requirements | Avoid dusty, high-vibration, direct sunlight, or corrosive gas environments |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | GCWP-A88 |
| Price | USD 2,000 (FOB) |
| Heating Method | Electric Resistance Heating |
| Cooling Method | Liquid Nitrogen Cryogenic Cooling |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Range | −30 °C to +200 °C |
| Electrode Material | Brass |
| Electrode Diameter | 25 mm |
| Test Frequency Range | 20 Hz to 2 MHz |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150, IEC 60250 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BETA201A.4 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (with optional dynamic mode support) |
| Analysis Stations | 1 |
| Surface Area Range | 0.0001 m²/g (using Kr adsorption) to unlimited |
| Pressure Range | 0–133 kPa |
| Repeatability | < ±1% |
| Operating Ambient Temperature | Up to 400 °C |
| Temperature Control Accuracy | ±0.1% |
| Vacuum System Base Pressure | ≤1×10⁻⁸ Pa (≤7.5×10⁻¹¹ Torr) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLC-AI |
| Quotation | USD 4,200 (FOB Beijing) |
| Instrument Type | Drop-Weight Impact Tester |
| Impact Energy | 300 J |
| Impact Velocity | 25 m/s |
| Hammer Moment (Impact Constant) | 24 N·m |
| Load Cell Range | 300 kN |
| Maximum Lift Height | 1500 mm |
| Hammer Mass Options | 5 kg / 15 kg / 20 kg (customizable) |
| Effective Impact Height | 1500 mm |
| Dimensions (L×W×H) | 1200 × 700 × 2100 mm |
| Weight | 300 kg |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DRD-1000KV |
| Price | USD 2,650 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GEST-126T |
| Test Voltage Range | DC 110 V / 220 V / 300 V / 500 V / 1000 V / 1500 V / 2000 V |
| Series Resistor | 10 kΩ |
| Maximum Breakdown Current | 200 mA |
| Electrode Material | Stainless Steel (AISI 304) |
| Measurement Accuracy | ±1% of reading |
| Compliance | GB/T 12476.9–2010, GB/T 16427–2018 |
| Includes | Main Unit, Pair of Parallel-Plate Electrodes, Two Glass Rods (for compaction), USB Data Cable |
| Key | Brand: Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DW-100 |
| Output Current | 1000 A AC (adjustable) |
| Temperature Channels | 2 acquisition + 1 control loop |
| Control System | Siemens PLC + 15″ HMI touchscreen |
| Power Supply | 380 VAC ±10%, 50 Hz ±0.5 Hz, 20 kW |
| Dimensions (L×W×H) | 1400 × 1150 × 1700 mm |
| Weight | 500 kg |
| Ambient Operating Range | −30–40 °C, ≤85% RH, ≤1000 m altitude |
| Grounding Resistance | ≤4 Ω |
| Seismic Withstand | Horizontal 3 m/s², Vertical 1.5 m/s² |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PMQS-I |
| Price | USD 2,800 (approx.) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | FTDZS-I |
| Price | USD 2,100 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZS-I |
| Price | USD 2,150 (approx.) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZS-I |
| Price | USD 2,150 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCCBC-B Series |
| Impact Energy Options | 1 J / 5 J / 25 J / 50 J (Charpy) |
| Impact Velocity | ≤4 J: 2.9 m/s |
| ≥7.5 J | 3.8 m/s (Charpy) |
| Pendulum Moment (Impact Constant) | 18 N·m |
| Load Cell Range | 16 kN |
| Maximum Lifting Height | 150 mm |
| Support Span | 230 mm (Charpy), 335 mm (Izod) |
| Pre-lift Angle | 150° |
| Specimen Dimensions (Charpy) | 40–95 mm (L) × 4–15 mm (W) × 3–10 mm (T) |
| (Izod) | 61.5–82 mm (L) × 10–12.7 mm (W) × 3.2–12.7 mm (T) |
| Anvil Radius | R = 1 mm (Charpy), R = 0.8 mm (Izod) |
| Striking Edge Angle | 30° |
| Striking Edge Radius | R = 2 mm |
| Power Supply | 220 V AC, 200 W |
| Release Mechanism | Electromagnetic motor-driven release |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCDDJ-100kV |
| Breakdown Voltage Range | 0–100 kV AC/DC |
| Electrical Capacity | 5 kVA |
| Input Voltage | AC 220 V / 50 Hz |
| Voltage Accuracy | ≤ ±1.5% |
| Rise Rate Adjustment | 0.1–5 kV/s (stepless) |
| Test Modes | Dielectric Strength, Withstand Voltage, Stepwise Voltage Testing |
| Detection Method | Dual-criterion (voltage drop + leakage current threshold) |
| Leakage Current Range | 0–100 mA |
| Voltage Sensor Range | 0–100 V (scaled to 100 kV) |
| Electrode Options | φ25 mm (×2), φ75 mm (×1), customizable |
| Test Medium | Ambient air, insulating oil bath (300 × 150 × 200 mm), optional high-temperature chamber |
| Safety Systems | Overvoltage, overcurrent, short-circuit, and ground-fault protection |
| Data Acquisition | Optically isolated digital I/O with Siemens S7 PLC control |
| Software Platform | Windows-based GUI with real-time curve plotting, Excel export, configurable reporting, and audit-ready test logging |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCDDJ-50kV |
| Breakdown Voltage Range | 0–50 kV AC/DC |
| Electrical Capacity | 5 kVA |
| Input Voltage | AC 220 V / 50 Hz |
| Rise Rate Adjustment | 0.1–5 kV/s (continuously variable) |
| Voltage Accuracy | ≤ ±1.5% |
| Leakage Current Measurement Range | 0–100 mA |
| Electrode Options | φ25 mm (×2), φ75 mm (×1), customizable |
| Test Medium | Air, oil bath (300×150×200 mm tank), or elevated temperature environment |
| Safety Protections | Overvoltage, overcurrent, short-circuit, and leakage current protection |
| Host Dimensions (L×W×H) | 1600 × 850 × 1700 mm |
| Weight | ~300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCDRD-5KV |
| Voltage Range | 0–5 kV DC |
| Compliance | GB/T 13542.2–2009, IEC 60674-2:1988 |
| Application | Electrical Weak Point Detection in Polymer Insulating Films |
| Control System | PC-based Closed-loop Voltage Ramp & Real-time Data Acquisition |
| Sample Handling | Motorized Unwind/Re-wind with Adjustable Linear Speed |
| Output Metrics | Weak Point Count per m², Weak Line Count, Automatic Zero Return & Statistical Summary |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCDRD5KV-ZX |
| Price | USD 1,850 (FOB Beijing) |
| Test Voltage Range | 0–10 kV DC (±1% stability) |
| Voltage Ramp Rate | Programmable |
| Film Traverse Speed | 2–5 m/min |
| Electrode Configuration | Copper roller (lower), conductive rubber roller (upper) |
| Data Output | Real-time voltage/current logging, weak-point coordinate mapping, areal density calculation (points/m²), linear spacing analysis (m/point), auto-zeroing post-test |
| Compliance | GB/T 13542.2–2009, IEC 60674-2:1988 |
| Software | Windows-based control & analysis suite with audit trail, CSV export, and GLP-compliant metadata tagging |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCFTDZ-I |
| Force Range | 0–5 kN (max. 3.9 MPa) |
| Pressure Control Accuracy | ±0.5% FS |
| Resistivity Measurement Range | 10⁻⁶ – 10⁵ Ω·m |
| Resistance Resolution | 10⁻⁸ Ω |
| Voltage Range | 2 mV – 2 V (±0.1% accuracy) |
| Current Sources | 10 μA to 10 A (7 ranges, ±0.5% accuracy) |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Sample Height Resolution | ±1 μm |
| Power Supply | 220 V / 50 Hz / 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCFTDZ-I |
| Price | USD 2,100 (FOB) |
| Force Range | 0–5 kN (up to 3.9 MPa) |
| Force Accuracy | ±0.5% FS |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Resistivity Measurement Range | 10⁻⁶ – 10⁵ Ω·m |
| Resistance Resolution | 10⁻⁸ Ω |
| Current Sources | 10 μA – 10 A (8 ranges) |
| Voltage Range | 2 mV – 2 V |
| Voltage Accuracy | ±0.1% |
| Thickness Resolution | ±1 μm |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GCFTDZ-I |
| Price | USD 2,100 (approx.) |
| Max Applied Force | 5 kN (equivalent to 3.9 MPa at φ30 mm electrode) |
| Force Accuracy | ±0.5% FS |
| Current Source Range | 10 μA – 10 A (8 ranges) |
| Voltage Measurement Range | 2 mV – 2 V |
| Resistance Measurement Range | 10⁻⁶ – 10⁵ Ω |
| Resolution | 10⁻⁸ Ω |
| Voltage Accuracy | ±0.1% |
| Current Source Accuracy | ±0.5% |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Height Resolution | ±1 μm |
| Test Modes | Constant Force, Constant Pressure, Gradient Force, Gradient Pressure, Compression Ratio |
| Data Output | USB export, thermal printer integration |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCFTDZ-I |
| Price | USD 2,100 (FOB) |
| Load Capacity | 0–5 kN (max. 3.9 MPa) |
| Force Accuracy | ±0.5% FS |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Current Source Range | 10 μA to 10 A (8 ranges) |
| Resistance Measurement Range | 10⁻⁶ Ω to 10⁵ Ω |
| Resistance Resolution | 10⁻⁸ Ω |
| Resistance Accuracy | ±0.5% |
| Voltage Range | 2 mV–2 V (4 ranges) |
| Voltage Accuracy | ±0.1% |
| Height Resolution | ±1 μm |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
