Harvard Apparatus
Filter
Showing 31–60 of 137 results
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | f/air |
| Capacity | 50 g (halogenated anesthetic gases) |
| Dimensions | 15.2 cm H × 8.3 cm D (6 in × 3.25 in) |
| Active Sorbent Mass | 200 g |
| Usage | Single-use, non-reusable |
| Accessories | Tubing connector sold separately |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Germinator 500 |
| Warm-up Time | 20 min |
| Operating Temperature | 250 °C (≈500 °F) |
| Sterilization Time | 2–5 sec |
| Well Depth | 20 cm |
| Well Diameter | 5 cm |
| Unit Dimensions (H×W×D) | 6.75″ × 5.25″ × 5.25″ |
| Stainless Steel Well Internal Dimensions | 2.0″ diameter × 4.0″ depth |
| Weight | 4.5 lbs |
| Electrical Input | 230–250 V, 60 Hz, 0.85 A, 110 W |
| Glass Bead Size | 1.5 mm lead-free glass spheres |
| Compliance | CE Marked (Test Report No. 991004/GERM/EMC 041800/AC187/LVD) |
| Warranty | 1 year |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Heat Therapy Pump |
| Flow Rate | 9–14 gal/hr (34–53 L/hr) |
| Operating Temperature Range | 85–107 °F (29.4–41.7 °C) |
| Hose Length | 10 ft (3 m) |
| Dimensions (W × D × H) | 8.5 × 5.6 × 6.25 in (20.6 × 14.3 × 16.2 cm) |
| Weight | 5.2 lb (2.6 kg) |
| Power Input | 120 VAC, 60 Hz (standard) |
| Connector Types | Click-Tight quick-connect or Colder metal cold-end fittings |
| Accuracy | ±2 °F (±1.1 °C) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Heat Therapy Pump |
| Connector Type | Click-Tight or Colder |
| Flow Rate | 9–14 gal/hr |
| Operating Temperature Range | 85–107 °F |
| Hose Length | 10 ft (3 m) |
| Power Supply | 120 VAC, 60 Hz or 220 VAC, 50 Hz |
| Dimensions (W × D × H) | 8.5 × 5.6 × 6.25 in (20.6 × 14.3 × 16.2 cm) |
| Weight | 5.2 lb (2.6 kg) |
| Accuracy | ±2 °F |
| Mobility | Four swivel casters + integrated carrying basket |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Heated Animal Small Table |
| Heating Power | 40 W |
| Heating Surface Area | 23 × 33 cm (9 × 13 in) |
| Includes One Set of Animal Restraint Accessories | 6 Adjustable Restraint Rods and Multiple Clamps |
| Supplier Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HOMECAGE |
| Price Range | USD 1,400 – 7,000 |
| Brand | Harvard Apparatus |
|---|---|
| Model | Homeothermic Blanket System |
| Origin | USA |
| Control Range | 35–40 °C (95–104 °F) |
| Preset Temperature | 37 °C |
| Probe Types | Flexible (2 mm Ø, 100 mm length) & Rigid Stainless Steel (1.6 mm Ø) |
| Blanket Sizes | Small (15 × 20 cm), Medium (45 × 70 cm), Large (60 × 90 cm) |
| Cable Length | 2 m (blanket & probe) |
| Power Delivery | Proportional DC control |
| Display | Front-panel LCD + LED power bar graph |
| Electrical Isolation | Floating design with optional grounding switch |
| Compliance | Designed for GLP-compliant in vivo physiological studies |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Homeothermic Blanket System |
| Temperature Range | 35–40 °C (95–104 °F) |
| Probe Types | Flexible (2 mm Ø, 100 mm length) & Rigid Stainless Steel (1.6 mm Ø) |
| Blanket Sizes | Small (15 × 20 cm), Medium (45 × 70 cm), Large (60 × 90 cm) |
| Power Supply | Regulated Low-Voltage DC |
| Control Method | Proportional Feedback Loop |
| Display | Front-Panel LCD + Horizontal LED Power Bar Graph |
| Cable Length | 2 m (probe & blanket) |
| Grounding Option | Front-Panel Switchable Ground |
| Electrical Noise Suppression | Integrated Shielded Circuitry |
| Compliance | Designed for GLP/GMP-aligned preclinical research environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HPMS |
| Instrument Type | ECG-based Multi-Parameter Physiological Monitor |
| Connectivity | Bluetooth 5.0 |
| Display Platform | Android tablet (included) |
| Data Output Formats | LabChart-compatible binary, CSV |
| Heating Platform | Temperature-regulated (setpoint range: 25–42 °C, ±0.3 °C stability) |
| Probe Compatibility | Rectal thermistor, ECG needle electrodes, SpO₂ sensor (reflectance-type), NIBP cuff (rat/mouse), Capnography module (sidestream CO₂) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Inspira ASVv (Volume-Controlled) |
| Animal Weight Range | 15 g – 10 kg |
| Tidal Volume Range | 0.1 – 100 mL |
| Respiratory Rate | 5 – 200 bpm |
| I | E Ratio Adjustment: 1:4 to 4:1 |
| Trigger Sensitivity (Assist Mode) | –1 to –10 cmH₂O |
| PEEP Capability | Not applicable (ASVv is volume-controlled |
| Cylinder Options | 0.1–10 mL and 10–100 mL glass/graphite piston-cylinder assemblies |
| Sigh Breathing | Programmable or manual trigger via front-panel SIGH button |
| Gas Compatibility | Non-flammable anesthetic agents (e.g., isoflurane, sevoflurane, nitrous oxide, halothane) |
| Interfaces | Front-mounted gas ports, dual analog outputs, external trigger input, synchronization output |
| Display | Backlit LCD with intuitive keypad navigation |
| Compliance | Designed for GLP-compliant preclinical research |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LDS 3000 |
| Dimensions | 134.6 cm H × 61.0 cm W (base diameter with casters) |
| Enclosure | Powder-coated, dust-resistant finish |
| Mobility | Five swivel casters (two with brakes) |
| Gas Exhaust Interface | Multi-port exhaust manifold for non-rebreathing circuit configuration |
| Included Accessories | (1) Two 64" black hoses (5.08 cm ID) |
| Vendor Type | Authorized distributor |
| Origin Category | Imported |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE507 / LE509 / LE512 |
| Dimensions (LE509 internal) | 252 × 280 × 240 mm |
| Dimensions (LE507 internal) | 190 × 220 × 240 mm |
| Aperture diameter (rat) | 23 mm, depth: 14 mm |
| Aperture diameter (mouse) | 13 mm, depth: 10 mm |
| Construction | Acrylic, aluminum alloy, stainless steel |
| Max simultaneous chambers per software instance | 8 |
| Sensor type | Infrared nose-poke detectors (per aperture and food tray) |
| Visual cue | Adjustable-brightness LED stimulus lights (per aperture) |
| Actuation | Motorized aperture shutters (individually controllable) |
| Reward delivery | Pellet dispenser (LE507/LE509), integrated per-aperture reward dispensers (LE512) |
| Software | Panlab PackWin v3.x (Windows-based, GLP-compliant experimental control & data acquisition) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE7106 |
| Stimulus Source | Halogen lamp |
| Max Stimulus Temperature | 250 °C |
| Ramp Time (40 °C → 250 °C) | ≤10 s |
| Default Cut-off Time | 20 s |
| Adjustable Cut-off Time | Yes |
| Temporal Resolution | 0.1 s |
| Display | 4-digit LED |
| Dimensions (Controller) | 350 × 350 × 130 mm |
| Dimensions (Stimulator) | 400 × 140 × 155 mm |
| Housing Material | Methyl methacrylate |
| Animal Weight Range | 20–400 g |
| Compliance | CE certified |
| Interface | RS232 |
| Optional Software | SeDaCom |
| Footswitch | Included |
| Tail Restraint | Adjustable groove-based fixture for mice and rats |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE7306 |
| Maximum Applied Force | 999 g |
| Resolution | 1 g |
| Tip Diameter Options | 1 mm (flat-tipped and conical-tipped) |
| Stimulus Probe Material | Acrylic (methyl methacrylate) |
| Compliance | CE-certified |
| Control Unit Dimensions (W × D × H) | 350 × 350 × 130 mm |
| Stimulator Unit Dimensions (W × D × H) | 150 × 210 × 166 mm |
| Software | SeDaCom v3.x for automated data acquisition, timestamped event logging, and statistical export (CSV, Excel-compatible) |
| Actuation | Stepper motor-driven linear displacement with real-time load cell feedback |
| Footswitch | Integrated remote foot pedal for hands-free start/stop and auto-return activation |
| Base Design | Rotational pivot mount to prevent lateral torque and excessive localized pressure on paw tissue |
| Display | Digital LED readout showing real-time force (g) and directional status |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LE830 |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Chamber Dimensions (H × W × D) | 16 × 25 × 18 cm |
| Construction Material | Optical-grade acrylic panels with stainless steel and white/transparent polymer inserts |
| Electric Shock Stimulus | 0–3 mA (square-wave, constant-current), programmable duration 0–10 s, foot-switch actuated |
| Required Ancillary Systems | HD video acquisition system (e.g., 60 fps USB3 camera with IR illumination), SMART 3.0 Behavioral Tracking Software (v3.0 or later) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE902 |
| Rotation Sensor Type | High-resolution bidirectional optical encoder |
| TTL Digital Output | Yes |
| Angular Resolution | Adjustable from 4 to 36 segments per full revolution |
| Recording Modes | Full and partial left/right rotations |
| Time Interval Logging | User-defined (e.g., 1 min, 5 min, 30 min bins) |
| Experimental Chamber Options | 400 mm diameter × 200 mm height circular bowl OR 400 mm diameter × 300 mm height cylindrical chamber |
| Tether Material | Flexible, low-torque silicone tether |
| Data Acquisition Software | SEDACOM V2.0 |
| Compliance | Designed for preclinical behavioral phenotyping in GLP-aligned research environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Martin ME 102 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | MC4000 |
| Animal Species | Mice and Rats |
| Measurement Principle | Oscillometric + Korotkoff-based Tail-Cuff Method |
| Simultaneous Channels | 4 |
| Measurement Duration per Animal | <15 min (15 readings) |
| Output Parameters | Systolic BP, Diastolic BP (directly measured), Mean Arterial Pressure, Heart Rate, Pulse Waveform |
| Data Storage | Full waveform + summary statistics (mean ± SD) |
| Compliance | Designed for GLP-compliant preclinical research |
| Software | Integrated database with audit trail, export to CSV/Excel, real-time PC streaming via USB |
| Analog Outputs | BP, HR, and pulse waveform (0–10 V) |
| Optional Accessories | Additional specimen platforms, species-specific tail cuffs, LED/sensor assemblies |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Micro Vent |
| Tidal Volume | 0–130 µL (continuously adjustable) |
| Respiratory Rate | 60–400 breaths/min (continuously adjustable) |
| Power Supply | 12 V DC, 0.5 A via external AC adapter |
| Dimensions (H×L×W) | 8 × 10 × 20 cm |
| Weight | 1.0 kg (unit), 0.3 kg (AC adapter) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | MiniVent |
| Tidal Volume Range | 30–350 µL |
| Respiratory Rate | 60–400 breaths/min |
| Power Supply | 115 V or 220 V AC |
| Dead Space Volume | <0.1 mL |
| Compliance Error Compensation | ±3 µL |
| Gas Inlet Options | Ambient air or explosion-proof gas mixtures |
| PEEP Capability | Yes |
| Included Accessories | Two silicone tubing sets (1.5 mm ID × 3.0 mm OD × 14 cm), tracheostomy cannula (1.3 mm OD, P/N 73-2730), endotracheal tube (1.2 mm OD, P/N 73-2844), multi-gas inlet adapter |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model Series | 5013xx |
| Heating Element | 250 W, 31 cm × 51.5 cm (12 in × 20 in) stainless steel surface |
| Max Animal Weight Capacity | 40 kg (88 lb) |
| Temperature Rise | +4.4°C above ambient (no load) |
| Base Options | Hydraulic or Fixed Stand |
| Electrical Configurations | 115 VAC/60 Hz or 230 VAC/50 Hz |
| Instrument Tray | 30 cm × 22.5 cm × 61 cm (L×W×H), vertical rod Ø12.5 mm |
| Cross Rods | Ø12.5 mm × 53.3 cm (0.5 in × 21 in) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | 51700 |
| Animal Weight Range | 10–75 g |
| Base Dimensions | 25 × 25 cm |
| Type | Mouse-Specific, Manual Precision Frame |
| Zeroing Function | Yes |
| Compatibility | Standard Stoelting Accessories (e.g., electrodes, cannulae, microinjection systems) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | 613 |
| Tidal Volume Range | 30–750 mL |
| Respiratory Rate | 7–50 breaths/min |
| I | E Ratio: 25–50% |
| Dimensions (H×W×D) | 30 × 50 × 22.5 cm |
| Weight | 21 kg |
| Inlet/Outlet ID | 12.7 mm |
| Inlet/Outlet OD | 14.4 mm |
| Power Options | 115 VAC or 230 VAC |
| Animal Weight Range | 1.5–50 kg |
| PEEP Capability | Yes (via water column) |
| Compliance | CE-marked |
| Gas Supply | Medical air or non-flammable gases |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 683 |
| Price | Upon Request |
| Tidal Volume (Small Cylinder) | 0.5–5 mL/stroke (0.5 mL increments) |
| Tidal Volume (Large Cylinder) | 3–30 mL/stroke (0.3 mL increments) |
| Respiratory Rate | 18–150 breaths/min (adjustable during operation) |
| PEEP Control | Yes |
| Dimensions (H×L×W) | 25 × 32.5 × 15 cm |
| Weight | 8 kg |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Gas Port ID/OD | 3.5 mm / 5 mm (instrument side), 2.2 mm / 4 mm (animal side) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 687 |
| Price | Upon Request |
| Tidal Volume Range | 0.05–1 mL/stroke (0.1 mL increments) |
| Respiratory Rate | 18–150 breaths/min (adjustable during operation) |
| PEEP Control | Yes |
| Dead Space Minimization | Dual-piston cylinder design with end-stroke termination |
| Cylinder Stroke Calibration | Permanent laser-etched volume scale |
| Flow Path Interface | Four-port configuration (Instrument In, Animal In, Animal Out, Instrument Out) |
| Port Dimensions | ID 2.2 mm (0.086 in), OD 4 mm (5/32 in) and ID 3.5 mm (1/8 in), OD 5 mm (3/16 in) |
| Dimensions (H×L×W) | 25 × 32.5 × 15 cm (10 × 13 × 6 in) |
| Weight | 8 kg (18 lb) |
| Power Input | 115/230 VAC, 50/60 Hz |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | MouseOx |
| Sensor Type | Reflectance-based photoplethysmographic probe |
| Measurement Parameters | SpO₂ (0–100%, accuracy < ±1.5% across full range), Pulse Rate (90–900 BPM, update latency 0.72 s per beat), Respiratory Rate (25–450 breaths/min, reported as 10-breath moving average every 1.7 s), Pulse Amplitude (0–800 µm vessel diameter equivalent, accuracy < ±2.4%), Respiratory Amplitude (quantified as thoracic/abdominal displacement magnitude) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Nanomite Pump |
| Drive Type | Microprocessor-Controlled Syringe Pump |
| Infusion/Withdrawal | Programmable |
| Accuracy | ±0.5% |
| Repeatability | ±0.05% |
| Syringe Capacity | 0.5 µL – 10 mL |
| Flow Rate Range | 0.54 pL/min – 11.7 mL/min |
| Display | 4.3" WQVGA TFT Color Touchscreen |
| Linear Force | 5 kg (11 lbf) |
| Step Resolution | 0.198 µm/step |
| Input Voltage | 12–30 VDC |
| Dimensions (Controller) | 22.6 × 17.78 × 15 cm |
| Weight | 1.96 kg |
| Compliance | CE, ETL (UL/CSA), WEEE, EU RoHS, CB Scheme |
| Interfaces | RS-232, USB, TTL Footswitch, RS-485, IEEE-1394, 15-pin D-Sub, Mini-Phono Jack |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | P1500 |
| Flow Rate Range | 0.01–1,500 mL/min |
| Maximum Speed | 235 rpm |
| Drive Motor Compatibility | Interchangeable P-70 / P-230 / P-1500 Modules |
| Display | Full-color LCD touchscreen interface |
| Control Interfaces | USB, RS-485, 15-pin digital I/O, analog input, footswitch port |
| Operating Modes | Constant Flow, Flow Ramp, Stepped, Pulsatile, Concentration-based dosing |
| Calibration Support | User-defined tubing ID/ID-OD, automatic flow calibration per tube type |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Packwin 2.0 |
| Price Range | USD 1,400 – 7,000 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PHD 22/2000 Hpsi |
| Injection Capacity | up to 800 mL (4 × 200 mL syringes) |
| Max Force Output | 197 kg (433 lbf) |
| Accuracy | ±0.5% (stability), ±0.05% (repeatability) |
| Syringe Range | 20–200 mL stainless steel only |
| Flow Rate | 1.5 µL/hr – 112 mL/min |
| Drive Resolution | 0.0397 µm/step |
| Input Voltage | 100–240 VAC, 50/60 Hz |
| Communication | RS-232 (9-pin D-Sub), TTL, RJ11-4 |
| Control Box Dimensions | 9.5 × 27.9 × 22.9 cm |
| Syringe Mount Dimensions | 22.9 × 43.2 × 30.5 cm |
| Cable Length | 1.5 m (standard), optional 9.1 m extension |
