Harvard Apparatus
Filter
Showing 91–120 of 137 results
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RGBP Research-Grade Invasive Blood Pressure Measurement System |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SAV 2500 |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | SC100 |
| Certification | CE |
| Channel Configuration | Single-channel (upgradable to dual-channel with additional specimen platform) |
| Measurement Method | Oscillometric + Korotkoff-based non-invasive tail-cuff sphygmomanometry |
| Output Interfaces | BNC (BP, HR, ECG waveform), 9-pin serial (data logging & PC connectivity), Centronics printer port |
| Compatibility | Mice and rats (four standard tail-cuff balloon sizes included) |
| Data Acquisition | Digital signal processing, real-time pulse detection, configurable respiratory artifact filtering |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Size 5 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Size1 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Surgical Lights |
| Pricing | Contact for Quotation |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Table Top |
| Gas Delivery System | Non-rebreathing, single-circuit |
| Vaporizer Type | TECH3 Isoflurane/Sevoflurane |
| Flow Range | 0–1000 mL/min (O₂) |
| Vapor Output Range | 0.5–5% |
| Weight | ~10 kg (unit + vaporizer) |
| Safety Features | Vaporizer lockout, visual drug level window, activated carbon scavenging system |
| Compliance | ASTM F2749-22 (Anesthetic Equipment), ISO 80601-2-13:2021 (Medical Electrical Equipment – Particular Requirements for Anesthetic Workstations) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Tabletop |
| Flowmeter Options | 0.2–4 L/min O₂, 0–1000 mL/min O₂, Dual O₂ (0.2–4 L/min + 0–1000 mL/min), or O₂ + N₂O with Fail-Safe Valve |
| Dimensions (W×D×H) | 30" × 20" × 32.5" (762 × 508 × 825.5 mm) |
| Weight | 25 lb (11.34 kg) |
| Animal Capacity | Single subject up to 4.5 kg |
| Circuit Type | Non-rebreathing |
| Compatible Vaporizers | Tech3, Tech4, Ohio, and 100-series |
| CO₂ Absorber | Optional standalone unit (Part #723010) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | TC-3000 |
| Input Channels | Single or Triple Thermocouple |
| Temperature Range (Single-Channel) | 25.0–45.0 °C (0.1 °C resolution, Celsius only) |
| Temperature Range (Triple-Channel) | −10.0 to +60.0 °C (14.0 to 140.0 °F), 0.1 °C resolution |
| Sampling Rate | 3 Hz per channel |
| Power Supply | 4 × C-cell batteries (included) |
| Output | Analog voltage output (0–5 V DC, proportional to temperature) |
| Display | Front-panel LCD with manual channel selection |
| Compliance | CE-marked, RoHS-compliant, designed for laboratory use under GLP conditions |
| Brand | Harvard Apparatus |
|---|---|
| Model | Tech3, 100 Series |
| Origin | USA |
| Fill Type | Funnel-Fill |
| Anesthetic Agents | Isoflurane, Halothane, Sevoflurane |
| Dial Settings | 0.5% and 1.0% increments |
| Inlet/Outlet Taper | 22–23 mm |
| Sump Capacity | 135 mL (35 mL absorbed by wick) |
| Dimensions (L × W × H) | 5.75 in × 5.25 in × 7.25 in |
| Weight | 1.5 lbs |
| Flow & Temperature Compensation | Yes |
| Sight Glass | Single |
| Manifold Design | Tapered, no check valve |
| Labeling | Color-coated agent-specific identification |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TFA |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TOPO |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Vaporstick Anesthesia Machine |
| Flow Rate Range | 0.2–4 L/min (O₂) |
| Optional N₂O Flowmeter | Yes |
| Fail-Safe Valve | Included (Model 723009) |
| Mounting | Z-Bracket Universal Vaporizer Holder |
| Circuit Type | Non-rebreathing (Jackson-Rees, Mapleson D) |
| Upgradeable to Rebreathing | Yes (with external CO₂ absorber) |
| Frame | 5-Point Castor Base with MRI-Compatible Option |
| Construction | FDA-Approved Polymer Housing |
| Surface Finish | Electrostatic Powder Coating |
| Dimensions (H×W) | 134 cm × 152.4 mm |
| Weight Capacity | Up to 4.5 kg Animals |
| Exhaust Management | Active Scavenging-Compatible Pop-up Exhaust Valve |
| Fresh Gas Outlet | Dedicated Non-rebreathing Port |
| Absorber Design | Sealed Canister with Optimized Soda Lime Exposure Geometry |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VentElite |
| Price Range | USD 1,400 – 7,000 |
| Weight Range | 10 g – 1 kg |
| Species Compatibility | Mice to Guinea Pigs |
| Airway Connection | Inlet 3.6–3.8 mm (0.14–0.15 in), Outlet 4.0 mm (0.16 in) |
| Ventilation Modes | Volume-Controlled and Pressure-Controlled |
| Tidal Volume Range | 50 µL – 5 mL |
| Tidal Volume Resolution | 1 µL |
| Tidal Volume Accuracy | ±0.1 µL |
| Peak Inspiratory Pressure (PIP) Range | 0–125 cmH₂O |
| PIP Accuracy | ±1.75 cmH₂O |
| PIP Resolution | 2.5 cmH₂O |
| Respiratory Rate | 10–300 bpm |
| I | E Ratio: 20%–80% |
| Sigh Frequency | 1 per 10–999 breaths (adjustable) |
| Sigh Volume/Pressure | 0–20% of set tidal volume (VC mode) or PIP (PC mode) |
| Gas Supply | Medical air or non-flammable gas mixtures |
| Alarms | High/low pressure, system fault |
| Input/Output Signals | TTL-compatible (0–5 VDC, 5 mA) |
| Communication Interface | RS-485 |
| Display | 7-inch resistive touchscreen LCD |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W × D × H) | 31.8 × 20.3 × 11.3 cm (12.5 × 8.0 × 4.45 in) |
| Weight | 3.4 kg (7.6 lbs) |
| Warranty | 2 years |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Heated Rodent Table |
| Heating Surface Area | 20 × 26 cm (8 × 10 in) |
| Accessories | Four stainless steel rods (6.5 mm / 0.25 in diameter), four tying cleats |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DigiGiat |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Species Compatibility | Mouse, Rat, Guinea Pig |
| Treadmill Speed Range | 0–25 cm/s |
| Incline/Decline Adjustment | ±15° |
| Imaging | High-Speed Monochrome Camera (≥200 fps), Cold-LED Illumination |
| Data Output | Spatial-Temporal Parameters (Stride Length, Stance Duration, Swing Phase, Paw Angle, Inter-Limb Coordination), Pressure-Weighted Contact Area (Relative Intensity Mapping) |
| Software | DigiGiat v3.2 with Automated Paw Detection, Kinematic Event Tagging, and Export to CSV/Excel |
| [Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model Range | NORT-3D Series |
| Price Range | USD 1,400 – 7,000] |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | BIO-TST4 |
| Sensor Type | Precision Load Cell (Gravity-Based Force Transduction) |
| Output Parameters | Immobility Time (s), Immobility Ratio (%), Mean Struggling Force (mN), Energy Expenditure (mJ), Threshold-Adjustable Immobility Detection |
| Connectivity | USB 2.0 |
| Max Concurrent Units per PC | 6 |
| Animal Capacity | 3–6 mice (configurable 3×2 array) |
| Housing Material | Black-and-White Acrylic Enclosure with Stainless Steel Hooks |
| Optional Integration | SMART 3.0 Video Analysis Module (add-on) |
| Data Export | CSV/Excel-compatible format |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE862 / LE865 |
| Stimulus Range | 0.1–2 mA (LE10025 Electrode Stimulator), Pulse Duration: 0.1–10 s |
| Detection Resolution | Single-lick resolution via patented sipper-tube sensor |
| Cage Capacity | Up to 32 cages per PC (with PACKWIN software) |
| Onboard Memory | 99 drinking events per detector |
| Compliance | Designed for GLP-aligned behavioral phenotyping workflows |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LE840 (Rat), LE842 (Mouse), H10-35-EPM (Universal) |
| Dimensions | LE840 — Enclosed Arms: 1000 × 1000 × 500 mm (gray walls) |
| Open Arms | 100 × 450 mm |
| LE842 — Enclosed Arms | 650 × 650 × 150 mm (gray walls) |
| Open Arms | 60 × 295 mm |
| H10-35-EPM — Arm Width | 250 px (≈63.5 mm), Arm Length: 1250 px (≈317.5 mm), Wall Height: 750 px (≈190.5 mm), Platform Height: 1375 px (≈349.3 mm) |
| Material | Cast Methyl Methacrylate (PMMA), Anodized Aluminum Frame |
| Transparent Wall Height | 30 mm (rat), 18 mm (mouse) |
| Tracking Compatibility | Manual Scoring or Video-Based Analysis with SMART 3.0 Software Suite (sold separately) |
| Output Metrics | Position Coordinates, Time Spent per Zone, Total Path Length, Instantaneous & Average Velocity, Arm Entries, Latency to First Entry |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE810 (mouse), LE812 (rat), LE816 (mouse, automated), LE818 (rat, automated) |
| Chamber Dimensions (mouse) | Light chamber 240 × 250 × 250 mm |
| Chamber Dimensions (rat) | Light chamber 240 × 310 × 310 mm |
| Detection | Load-cell-based position sensing |
| Interface | RS-232 serial communication |
| Software | PPCWIN v3.x (Windows-compatible) |
| Compliance | Designed for GLP-aligned behavioral phenotyping workflows |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE895/6/7/8 |
| Detection Method | Video Tracking (SMART 3.0) or Load-Cell-Based Gravimetric Sensing (PPCWIN) |
| Max Concurrent Units | 8 chambers per PC |
| Rat Chamber Assembly | 88 × 47 × 1125 px (L×W×H) |
| Compartment | 40 × 34 × 1125 px |
| Passage | 25 × 13 × 1125 px |
| Mouse Chamber Assembly | 46 × 27 × 625 px |
| Compartment | 20 × 18 × 625 px |
| Passage | 20 × 7 × 625 px |
| Construction | Optical-grade acrylic |
| Configurable Cues | Interchangeable wall textures/colors, modular floor substrates (tactile/visual), repositionable 3D spatial dividers |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE 7406 |
| Heating Plate Material | Pure Aluminum |
| Heating Plate Dimensions (D × T) | 200 mm × 10 mm |
| Base Dimensions (L × W × H) | 200 mm × 300 mm × 110 mm |
| Cylinder Dimensions (D × H) | 200 mm × 250 mm |
| Temperature Range | 45–62 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Time Resolution | 0.1 s |
| Input Control | Footswitch-activated timing |
| Data Output | RS-232 serial interface |
| Compliance | CE-marked |
| Optional Software | SeDaCom |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE116 |
| Price Range | USD 1,400 – 7,000 |
| Dimensions | 250 × 250 × 250 mm (L×W×H) |
| Animal Weight Range | 15–500 g |
| Acoustic Stimulus Range | 200–10,000 Hz, 60–120 dB |
| Sensor Technology | Precision Load Cell-Based Gravimetric Detection |
| Stimuli Control | Programmable Light, Tone, Foot Shock, Air Puff |
| Max Simultaneous Units | 8 per PC |
| Software Modules | PACKWINCS-FR (Fear Conditioning), PACKWINCS-ST (Startle Reflex) |
| Environmental Configurability | Interchangeable Floor/Wall Panels, Modular Chamber Geometry (Square, Circular, Triangular) |
| Compliance | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | Harvard Apparatus |
|---|---|
| Origin | Mexico |
| Model | LE7420 |
| Temperature Range | −3 °C to 65 °C (at ambient 20–25 °C, 50% RH) |
| Temperature Uniformity | < 0.5 °C across plate surface |
| Timing Resolution | 0.1 s |
| Plate Dimensions | 165 × 165 mm |
| Base Dimensions | 305 × 280 × 158 mm |
| Weight | 6.5 kg |
| Included Software | BSRamp Software |
| Optional Software | SeDaCom Data Acquisition Software |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | LE7500 |
| Price Range | USD 1,400 – 7,000 |
| Control Unit Dimensions (W × D × H) | 280 × 280 × 110 mm |
| Stimulus Unit Dimensions (W × D × H) | 230 × 220 × 300 mm |
| Activation | Front-panel keypad or footswitch |
| Resolution | 0.01 mL (3-digit display) |
| Chamber Material | Methyl methacrylate (PMMA) |
| Frame Material | Stainless steel |
| Electrode Material | Platinum |
| Certification | CE-marked |
| Measurement Parameter | Paw volume (displacement-based plethysmography) |
| Interface | RS-232 serial connection to PC |
| Software Control | PC-based acquisition and analysis interface |
| Auto-zero function | Footswitch-triggered |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE7900 |
| Touchscreen Resolution | 0.05 g |
| Averaging Time | 1–300 s |
| Max Load Capacity | 2000 g |
| Controller Dimensions | 17 × 25 × 10 cm |
| Weight Units | g / N / lb |
| Data Storage | 200 entries |
| Animal Compatibility | Mouse, Rat, Rabbit (with optional kit) |
| Software | SeDaCom (Excel export supported) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE803 / LE804 |
| Cup Dimensions (LE804) | 10 cm Ø × 25 cm H |
| Cup Dimensions (LE803) | 20 cm Ø × 50 cm H |
| Cup Dimensions (LE803L) | 30 cm Ø × 50 cm H |
| Behavioral Classification | Immobility, Swimming, Climbing |
| Detection Accuracy | <4% error rate |
| Reproducibility | 100% |
| Camera Configuration | Dual-angle (top-down + side-view) |
| Software | SMART v3.x with GLP-compliant data archiving |
| Throughput | Up to 4 rodents simultaneously |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE8205 |
| Price Range | USD 1,400 – 7,000 |
| Rotation Speed Range | 4–40 rpm |
| Acceleration Ramp Duration | 30 s – 100 min |
| Time Resolution | 1 s |
| Drum Diameter Options | Species-Specific (Mouse/Rat) |
| Height Extension Kit | 375 mm (Modular, Removable) |
| Fall Detection | Real-Time Optical/Position-Based Triggering |
| Data Output | USB & RS-232 |
| Software | SedCom v3.x (Windows-based Statistical Analysis Suite) |
| Compliance | GLP-Ready Architecture, Audit Trail Capable (FDA 21 CFR Part 11 Optional Configuration) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE830 |
| Chamber Dimensions | 16 × 25 × 450 px (W × D × H) |
| Floor Configuration | Four identical stainless steel plates (8 × 275 px each), 4 mm inter-plate gap |
| Stimulus Type | Square-wave current |
| Current Range | 0–3 mA |
| Pulse Duration | 1–10 s |
| Stimulus Trigger | Footswitch-activated |
| Output Metric | Number of plate crossings (i.e., shocks delivered per 60 s) |
| Construction | White opaque plastic walls, transparent acrylic lid, stainless steel floor plates |
| Intended Species | Mus musculus (adult mice) |
| Application Domain | Preclinical anxiety phenotyping and anxiolytic drug screening |
