HORIBA
Filter
Showing 121–150 of 676 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-72 |
| Form Factor | Benchtop |
| Conductivity Range | 0.0 µS/m – 1.999 S/m |
| TDS Range | 0.01 mg/L – 1000 g/L |
| Resistivity Range | 0.0 Ω·m – 1.999 MΩ·m |
| Salinity Range | 0.00 – 80.00 ppt |
| Temperature Range | 0.0 – 100.0 °C (extended to −30.0 – 130.0 °C) |
| Accuracy | ±0.5% F.S. ±1 digit (conductivity/resistivity/salinity/TDS), ±0.1 °C ±1 digit (temperature) |
| Resolution | 0.05% F.S. (conductivity/resistivity), 0.01 ppt (salinity), 0.01 mg/L (TDS), 0.1 °C (temperature) |
| Data Storage | 2000 measurements |
| Compliance | JIS Z 8806, USP <645>, EP 2.2.38, JP XVIII, ChP (Chinese Pharmacopoeia) General Chapter 0681 |
| Language Support | English, Japanese, Chinese, Korean |
| Power Supply | AC adapter 100–240 V, 50/60 Hz, ~9.8 VA |
| Weight | 700 g |
| Interfaces | USB port for PC communication and USB mass storage |
| GLP/GMP Features | Audit trail-capable data logging, user authentication support, calibration history with timestamped entries |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-72 |
| Form Factor | Benchtop |
| Conductivity Range | 0.0 µS/m – 1.999 S/m |
| TDS Range | 0.01 mg/L – 1000 g/L |
| Resistivity Range | 0.0 Ω·m – 1.999 MΩ·m |
| Salinity Range | 0.00 – 80.00 ppt |
| Temperature Range | 0.0 – 100.0 °C (extended to −30.0 – 130.0 °C) |
| Accuracy | ±0.05% F.S. |
| Resolution | 0.001 (unit-dependent) |
| Data Storage | 2000 sets |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVIII, ChP |
| Language Support | English, Japanese, Chinese, Korean |
| Power Supply | AC adapter 100–240 V, 50/60 Hz |
| Power Consumption | ~9.8 VA |
| Weight | ~700 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-72 |
| Form Factor | Benchtop |
| Conductivity Range | 0.0 µS/m – 1.999 S/m |
| TDS Range | 0.01 mg/L – 1000 g/L |
| Resistivity Range | 0.0 Ω·m – 1.999 MΩ·m |
| Salinity Range | 0.00 – 80.00 ppt |
| Temperature Range | 0.0 – 100.0 °C (extended to −30.0 – 130.0 °C) |
| Accuracy | ±0.05% of Full Scale |
| Resolution | 0.05% of Full Scale |
| Data Storage | 2000 measurements |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVIII, ChP |
| Connectivity | USB host/device, GLP/GMP-compliant data export |
| Language Support | English, Japanese, Chinese, Korean |
| Power | AC adapter 100–240 V, 50/60 Hz, ~9.8 VA |
| Weight | 700 g |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Model | Duetta |
| Wavelength Range (Excitation/Absorption) | 250–1000 nm |
| Wavelength Range (Emission) | 250–1100 nm |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Optical Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Fluorescence Sensitivity (Water Raman SNR) | ≥6000:1 (350 nm excitation, 5 nm bandwidth) |
| Absorbance Accuracy | ≤±0.02 A |
| Absorbance Range | 0–2 A |
| Spectral Acquisition Rate | ≥510,000 nm/min |
| A-TEEM Mode Acquisition Time | ≤30 s |
| EEM 3D Scan Time | ≤1 s (configurable) |
| Light Source | 75 W Xenon Arc Lamp |
| Detector (Fluorescence) | CCD Array |
| Detector (Absorption) | Silicon Photodiode |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Duetta |
| Wavelength Range (Fluorescence) | 250–1100 nm |
| Detection Technology | Back-Illuminated CCD |
| Sensitivity (Water Raman S/N) | >6000:1 |
| Dispersion Element | Holographic Grating |
| Slit Width / Spectral Bandpass | Variable, software-controlled |
| Wavelength Accuracy | ±0.5 nm |
| Internal Correction | Automated primary and secondary inner-filter effect compensation |
| Core Technology | A-TEEM™ (Absorbance-Transmitted Excitation-Emission Matrix) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Duetta |
| Wavelength Range (Fluorescence) | 250–1100 nm |
| Spectral Bandwidth (Slit) | 1–20 nm |
| Optical Resolution | 1 nm |
| Sensitivity (Water Raman RMS) | 6000:1 |
| Wavelength Accuracy | ±1 nm |
| Dispersion Element | Grating |
| Detector | CCD |
| Measurement Modes | Simultaneous Fluorescence & Absorbance |
| A-TEEM™ Capability | Yes |
| Auto Inner-Filter Correction | Yes |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | EasyRatioPro |
| Spectral Dispersion Element | Grating |
| Excitation Wavelength Control | Motorized Dual-Filter Wheel with Precision Filter Positioning |
| Maximum Wavelength Scanning Speed | 500 nm/s |
| Illumination Technology | DeltaRAM™ High-Speed Monochromatic Illumination System |
| Data Acquisition Engine | PAE (Precision Acquisition Engine) |
| Human Interface | WarpDrive™ Ergonomic Control Console |
| Primary Applications | Intracellular Ca²⁺, Na⁺, and pH Ratiometric Imaging |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection Type | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Correction |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional extended range) |
| Sample Flow Rate | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient Temperature | –5 to 40 °C |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication Interface | RS-485 |
| Protocol | Modbus RTU |
| Baud Rates | 1200–19200 bps |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual (standard), Auto (optional) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection Type | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) / 0–50 ppm to 0–2000 ppm (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional extended range) |
| Sample Flow Rate | 500 mL/min |
| Operating Ambient Temperature | –5 to +40 °C |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication Interface | RS-485, Modbus RTU (optional) |
| Sample Gas Requirements | O₂ <21%, dust-free, dry, pressure ≥1.98 kPa |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual (standard), Auto-calibration (optional) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection Type | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Minimum Detection Limit | 0–50 ppm (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional extended range) |
| Sample Flow Rate | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient Temperature | –5 to +40 °C |
| Analog Output | Isolated DC 4–20 mA (standard), optional 0–10 V / Modbus RTU via RS-485 |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂ (196–690 kPa |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Interference-Corrected Non-Dispersive Infrared (NDIR) Absorption |
| Measurands | CO, CO₂, CH₄ (configurable per application) |
| Range Options | 0–0.11 vol% to 0–100 vol% (CO/CO₂), 0–50 ppm to 0–2000 ppm (CH₄) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient | –5 to 40 °C, ≤90% RH |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / Modbus-RTU over RS-485 |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5–10 L/min |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Correction |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) / 0–50 ppm to 0–2000 ppm |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow | 500 mL/min |
| Operating Ambient | –5 to +40 °C, RH <90%, vibration <0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication | RS-485, Modbus RTU (selectable baud rates: 1200–19200 bps) |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5 L/min (operational), 10 L/min (purge) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Correction |
| Detectable Gases | CO, CO₂, CH₄ (configurable) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero/Full-Scale Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional range) |
| Sample Flow Rate | 500 mL/min |
| Operating Temperature | −5 to +40 °C |
| Analog Output | Isolated 4–20 mA (DC), optional voltage outputs |
| Communication | RS-485, Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Sample Gas Requirements | O₂ <21%, dust-free, dry, pressure ≥1.98 kPa |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual standard |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (CO/CO₂), 0–50 ppm to 0–2000 ppm (CH₄) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow | 500 mL/min |
| Operating Ambient | –5 to +40 °C, RH <90%, vibration <0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication | RS-485, Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5–10 L/min |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Interference-Corrected Non-Dispersive Infrared (NDIR) Absorption |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% FS (standard range) |
| Linearity | ±1.0% FS |
| Zero & Span Drift | ±2.0% FS/week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow | 500 mL/min |
| Operating Ambient | –5 to +40 °C, RH <90%, vibration <0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V |
| Communication | RS-485, Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5 L/min (operational), 10 L/min (purge mode) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection Type | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) / 0–50 ppm to 0–2000 ppm (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow Rate | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient Temperature | –5 to +40 °C |
| Analog Output | Isolated DC 4–20 mA (standard), optional 0–10 V / 0–5 V / 1–5 V / 0–16 mA |
| Communication Interface | RS-485 |
| Protocol | Modbus-RTU |
| Baud Rates | 1200–19200 bps |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual (standard), Auto-calibration (optional) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% FS (standard range) |
| Linearity | ±1.0% FS |
| Zero/Scale Drift | ±2.0% FS/week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional extended range) |
| Sample Flow Rate | 500 mL/min |
| Operating Ambient | –5 to +40 °C, RH <90%, vibration <0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V |
| Communication | RS-485, Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5 L/min (operational), 10 L/min (purge) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection Type | Ex d IIB+H2 T4 (EIA-51d) / Ex p IIB T4 X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption with Interference Compensation |
| Measured Gases | CO, CO₂, CH₄, and other hydrocarbons |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% F.S. (zero & span, standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional ranges) |
| Sample Flow Rate | 500 mL/min |
| Operating Temperature | –5 to +40 °C |
| Analog Output | Isolated DC 4–20 mA (standard), optional 0–10 V / 1–5 V / 0–1 V |
| Communication | RS-485, Modbus RTU (selectable baud rates: 1200–19200 bps) |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p IIT4 X (EIA-51p) |
| Measurement Principle | Interference-Corrected Non-Dispersive Infrared (NDIR) Absorption |
| Detectable Gases | CO, CO₂, CH₄, and other hydrocarbons |
| Minimum Range | 0–0.11 vol% (gas-dependent) / 0–50 ppm |
| Maximum Range | 0–100 vol% / 0–2000 ppm |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow Rate | 500 mL/min |
| Operating Ambient Temperature | –5 to +40 °C |
| Analog Output | Isolated DC 4–20 mA (optional 0–10 V, 0–5 V, etc.) |
| Communication | RS-485 Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual standard / Auto calibration optional |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Correction |
| Detection Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero/Scale Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional extended range) |
| Sample Flow | 500 mL/min |
| Operating Ambient | –5 to +40 °C, RH <90%, vibration <0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V |
| Communication | RS-485, Modbus RTU (selectable baud rates: 1200–19200 bps) |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5 L/min (operational), 10 L/min (purge mode) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Measured Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow Rate | 500 mL/min |
| Operating Ambient Temperature | –5 to +40 °C |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V |
| Communication | RS-485, Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual standard / Auto-calibration optional |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Measured Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (CO/CO₂), 0–50 ppm to 0–2000 ppm (CH₄) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient | –5 to +40 °C, RH ≤90%, vibration ≤0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (standard), optional 0–10 V / 0–5 V / 1–5 V |
| Digital Interface | RS-485, Modbus RTU (selectable baud rates: 1200–19200 bps) |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual (standard), Auto-calibration (optional) |
| Purge Gas | N₂, 196–690 kPa, 0.5 L/min (operational), 10 L/min (purge mode) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Measured Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) / 0–50 ppm to 0–2000 ppm |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow Rate | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Ambient Operating Temperature | –5 to +40 °C |
| Analog Output | Isolated 4–20 mA (standard), optional 0–10 V / 0–5 V / 1–5 V |
| Communication | RS-485, Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5 L/min (operational), 10 L/min (purge mode) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d, EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Minimum Detection Limit | 0–50 ppm (gas-dependent) |
| Repeatability | ±0.5% FS (standard range) |
| Linearity | ±1.0% FS |
| Zero/Scale Drift | ±2.0% FS/week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional ranges) |
| Sample Flow | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient | –5 to +40 °C, RH ≤90%, vibration ≤0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication | RS-485, Modbus RTU (selectable baud rates: 1200–19200 bps) |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5 L/min (operational), 10 L/min (purge) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) / 0–50 ppm to 0–2000 ppm |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero/Full-Scale Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow Rate | 500 mL/min |
| Operating Ambient | –5 to +40 °C, RH <90%, vibration <0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication | RS-485, Modbus RTU (selectable baud rates: 1200–19200 bps) |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5–10 L/min |
| Brand | HORIBA |
|---|---|
| Origin | Imported |
| Manufacturer | HORIBA, Ltd. |
| Model | EMGA-Expert |
| Detection Principle | Pulse Heating Extraction + NDIR (CO/CO₂, H₂O) & TCD (N₂) |
| Gas Detection Methods | Non-Dispersive Infrared (NDIR) for O and H |
| Automation Options | Auto-Sampler, Auto-Crucible Loader, Auto-Electrode Cleaner, Halogen Trap |
| Compliance Support | ASTM E1019, ISO 14284, ISO 22356, JIS G 1257, USP <233>, FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready software architecture |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | EMIA-Expert |
| Pricing | Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace |
| Maintenance Interval | Up to 200 Analyses Without Service |
| Analysis Time | ≤70 Seconds per Sample |
| 清扫 Mechanism | Brushless Automatic Cleaning System |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | EMIA-Pro |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Measurement Range | C: 0.0002–6.0 wt% |
| S | 0.0002–1.0 wt% |
| Sensitivity | C: 0.01 ppm |
| S | 0.01 ppm |
| Accuracy | C: ±1 ppm or ±1.0% RSD |
| S | ±1 ppm or ±1.5% RSD |
| Analysis Time | 40 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ENDA-600ZG |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±1.0 %F.S. |
| Repeatability | ±0.5 %F.S. |
| Response Time (SO₂) | 60–240 s |
| Stability | ±2.0 %F.S./week |