HORIBA
Filter
Showing 31–60 of 676 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9625-10D |
| Temperature Range | 0–100 °C |
| pH Range | 0–14 |
| ORP Range | ±1500 mV |
| Electrode Type | Combination pH/ORP/Temp (3-in-1), Gel-Filled, Plastic Body, Flat-Tipped ISFET-Glass Hybrid Design |
| Response Time (pH) | ≤15 s (t₉₀, ΔpH = 1.0) |
| Drift | <0.01 pH/h (25 °C, buffered solution) |
| Reference System | Cation-Selective Hollow-Fiber Junction |
| Glass Membrane | Rare-Earth-Doped High-Strength Bulb (JIS S 6001 Compliant, >10× strength) |
| Storage | Dry (no KCl soaking required) |
| Electrode Head Geometry | Flat, 100 µm clearance to protective sleeve |
| ESD Protection | Integrated semiconductor-grade anti-static circuitry |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9680-10D |
| Temperature Range | 0–100 °C |
| pH Range | 0–14 |
| Electrode Type | Composite Glass pH Electrode with Integrated Reference System |
| Body Material | Chemically Resistant Plastic |
| Tip Geometry | Flat-Surface, Semi-Hemispherical Bulb |
| Compliance | JIS Z 8802 (pH Electrode Performance Standards), ISO 7027 (for optical interface compatibility in hybrid systems) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9681-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Electrode Type | Combined Glass/Reference/ATC (Integrated Temperature Compensation) |
| Construction | Ruggedized Plastic Body with Hemispherical Tip |
| Sensing Surface | Flat-Tip Glass Membrane |
| Compliance | Meets JIS Z 8802 for pH electrode mechanical strength (10× requirement) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 5002A-10C |
| Measuring Range | 0.1–1000 ppm NH₃ |
| Electrode Type | Composite ISE (integrated reference) |
| Compatible Instruments | HORIBA F-72, F-73, F-74, F-74BW benchtop analyzers |
| Regulatory Compliance | Designed for ISO 5667-3, ASTM D1426, and EPA Method 350.1 applications |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APDA-370 |
| Measurement Principle | Beta-ray Attenuation Method |
| Measured Parameter | PM₁₀ |
| Range | 0–1000 / 5000 µg/m³ (standard) |
| Repeatability | ±20 µg/m³ @ 200/500 µg/m³ |
| Linearity | ±30 µg/m³ @ 200/500 µg/m³ |
| Zero Drift | ±20 µg/m³/day across all ranges |
| Span Drift | ±30 µg/m³/day @ low ranges |
| Sampling Flow Rate | ~16.7 L/min |
| Measurement Interval | 1 hour |
| Data Output | RS-232C, optional LAN (TCP/IP), analog 0–1 V, pulse & contact I/O |
| Power Supply | AC 100 V ±10 V, 50/60 Hz, ~200 VA |
| Dimensions | 430 × 483.5 × 266 mm (W×D×H) |
| Weight | Monitor unit: ~19 kg |
| Sampling pump | ~5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APDA-370 |
| Measurement Principle | Beta-ray attenuation |
| Measured Parameters | PM2.5 and PM10 |
| Range | 0–1000/5000 µg/m³ (standard), up to 10,000 µg/m³ (custom configurations) |
| Repeatability | ±20 µg/m³ @ 200/500 µg/m³ |
| Linearity | ±30 µg/m³ @ 200/500 µg/m³ |
| Zero Drift | ±20 µg/m³/day across all ranges |
| Span Drift | ±30 µg/m³/day @ low ranges |
| Sampling Flow Rate | ~16.7 L/min |
| Measurement Interval | 1 hour |
| Data Output | RS-232C, optional LAN (TCP/IP), analog 0–1 V, pulse & contact I/O |
| Power Supply | AC 100 V ±10 V, 50/60 Hz, ~200 VA |
| Dimensions (W×D×H) | 430 × 483.5 × 266 mm |
| Weight | Monitor unit: ~19 kg |
| Sampling pump | ~5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APDA-375A |
| Measurement Principle | Beta-ray Absorption |
| Safety Classification | Non-explosion-proof |
| Measurement Range | Standard: 0–1000 / 0–5000 µg/m³ |
| Resolution | ±1.0 µg/m³ (instantaneous) |
| Accuracy | ±2.0 µg/m³ (24-h average) or ±1% of reading (for concentrations >80 µg/m³) |
| Detection Limit | <1.0 µg/m³ (24-h average), <4.8 µg/m³ (1-h average) |
| Sampling Flow Rate | 16.7 L/min |
| Cut-point Options | VSCC (Vortex Separation Cyclone Classifier) for PM10 |
| Operating Temperature | −30 to +60 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 220 V, 50/60 Hz |
| Power Consumption | ~200 VA (up to ~320 VA with optional dehumidification & heater) |
| Dimensions (Analyzer Unit) | 430 W × 400 D × 266 H mm |
| Weight (Analyzer Unit) | ~19 kg |
| Weight (Pump Unit) | ~5 kg |
| Analog Output | 4–20 mA or 0–1 V |
| Digital Interfaces | Optional RS-232C, Ethernet (TCP/IP) |
| Environmental Compliance | Designed for continuous ambient air quality monitoring per ISO 12103-1, EN 12341, and US EPA EQOA-PM-01 reference method equivalency criteria |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APHA-370 |
| Instrument Type | Online Gas Analyzer |
| Target Analytes | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC) |
| Measurement Principle | Flame Ionization Detection (FID) with Selective Combustion Technology |
| Detection Limit | 0.050 ppmC (2σ, ≤5 ppmC range) or 0.5% F.S. (2σ, >5 ppmC range) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±2.0% F.S. |
| Zero Drift | ±0.1 ppmC/day or ±2.0% F.S./day (whichever is greater) |
| Span Drift | ±2.0% F.S./day |
| Response Time (T90) | ≤60 s |
| Sample Flow Rate | ~0.9 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 W × 550 D × 221 H mm |
| Weight | ~33 kg |
| Output Signals | 0–1 V / 0–10 V / 4–20 mA (user-selectable) |
| Data Storage | CF card (optional) |
| Communication | Ethernet/LAN interface (optional) |
| Display Language | English, German, French, Japanese |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APHA-370 |
| Measurement Principle | Flame Ionization Detection (FID) with Selective Combustion Technology |
| Target Analytes | CH₄, NMHC, THC (expressed as ppmC) |
| Standard Range | 0–5 / 10 / 20 / 50 ppmC |
| Optional Range | 0–100 ppmC (4 selectable spans, span ratio ≤10) |
| Detection Limit | 0.050 ppmC (2σ, for ranges ≤5 ppmC) or 0.5% F.S. (2σ, for ranges >5 ppmC) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±2.0% F.S. |
| Zero Drift | ±0.1 ppmC/day or ±2.0% F.S./day (whichever is greater) |
| Span Drift | ±2.0% F.S./day |
| Response Time (T90) | ≤60 s |
| Sample Flow Rate | ~0.9 L/min |
| Output Signals | 0–1 V, 0–10 V, 4–20 mA (user-specified) |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 W × 550 D × 221 H mm |
| Weight | ~33 kg |
| Display Language Options | English, German, French, Japanese |
| Data Storage | CF card (optional) |
| Network Interface | Ethernet/LAN (optional) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Laboratory Benchtop CEMS |
| Detection Principle | Selective Catalytic Oxidation + Flame Ionization Detection (FID) |
| Measurement Targets | CH₄, NMHC, THC |
| Detection Range | 0–50 / 200 / 500 / 1000 / 2000 ppm (selectable full-scale ranges) |
| Response Time | <150 s at sample inlet |
| Configuration | Integrated VOC Analyzer for Stack/Flue Gas Applications |
| Compliance Context | Designed for regulatory-grade monitoring per EPA Method 25A, ISO 12039, and EN 12619 requirements |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APMA-370 |
| Instrument Type | Portable Gas Analyzer |
| Detection Target | Single-component (CO) |
| Measurement Range | 0–5 / 0–10 / 0–20 / 0–50 ppm (selectable) |
| Repeatability | ±1.0% F.S. |
| Response Time (T90) | ≤60 s (at lowest range) |
| Zero Drift | ±0.1 ppm/day or ±1.0% F.S./day (whichever is greater) |
| Span Drift | ±2.0% F.S./day or ±3.0% F.S./week |
| Linearity Error | ±1.0% F.S. |
| Detection Limit | 0.05 ppm (2σ, for ranges ≤10 ppm) |
| Sample Flow Rate | ~1.5 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~16 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APNA-370(G) |
| Instrument Type | Online Continuous Emission Monitor |
| Measured Gases | Nitric Oxide (NO), Nitrogen Dioxide (NO₂), Total Nitrogen Oxides (NOₓ) |
| Response Time (T90) | ≤120 s |
| Detection Limit | 0.5 ppb (2σ, ≤0.2 ppm range) / 1.0% F.S. (2σ, >0.2 ppm range) |
| Measurement Range | 0–10 ppm (4 selectable sub-ranges, max span ratio 10:1) |
| Accuracy | ±1.0% F.S. (linearity & repeatability) |
| Zero Drift | ±1.0 ppb/day or ±1.0% F.S./day (whichever greater) |
| Span Drift | ±1.0% F.S./day |
| Sample Flow Rate | ~0.8 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~21 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APNA-370 |
| Measurement Principle | Dual-Flow Modulated Chemiluminescence Detection (CLD) |
| Range Options | 0–0.1 / 0.2 / 0.5 / 1.0 ppm (standard) |
| LOD | 0.5 ppb (2σ, ≤0.2 ppm range) or 1.0% F.S. (2σ, >0.2 ppm range) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±1.0 ppb/day or ±1.0% F.S./day (whichever greater) |
| Span Drift | ±1.0% F.S./day |
| Response Time (T₉₀) | ≤120 s (at minimum range) |
| Sample Flow Rate | ~0.8 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 W × 550 D × 221 H mm |
| Weight | ~21 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APOA-370 |
| Measurement Principle | Non-Dispersive Ultraviolet (NDUV) Absorption |
| Range | 0–0.1 / 0.2 / 0.5 / 1.0 ppm (standard) |
| Detection Limit | 0.5 ppb (2σ, ≤0.2 ppm range) or 0.5% F.S. (2σ, >0.2 ppm range) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±1.0% F.S./day, ±2.0% F.S./week |
| Span Drift | ±1.0% F.S./day, ±2.0% F.S./week |
| Response Time (T90) | ≤120 s |
| Sample Flow Rate | ~0.7 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~20 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APOA-370 |
| Instrument Type | Fixed-Position |
| Measurement Range | 0–10 ppm |
| Detection Limit | 0.5 ppb |
| Response Time (T90) | ≤120 s |
| Zero Drift | ±1% F.S./day |
| Resolution | 0.1 ppb |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APSA-370 |
| Detection Principle | Ultraviolet Fluorescence (UVF) |
| Measurement Range | 0–100 ppb to 0–10 ppm (field-selectable) |
| Detection Limit | <50 ppt (3σ, 1-minute average) |
| Accuracy | ±1% of full scale |
| Response Time (T90) | <60 seconds |
| Sample Flow Rate | 0.5–1.0 L/min |
| Operating Temperature | 0–40 °C |
| Humidity Tolerance | 0–90% RH (non-condensing) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Compliance | EPA EQOA-01, ISO 7935:1990, JIS K 0301 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APSA-370 |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Range | 0–0.05 / 0.1 / 0.2 / 0.5 ppm (standard) |
| LOD | 0.5 ppb (2σ, for ranges ≤0.2 ppm) or 0.5% F.S. (2σ, for ranges >0.2 ppm) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±1.0% F.S./day (lowest range), ±2.0% F.S./week (lowest range) |
| Span Drift | ±1.0% F.S./day (lowest range), ±2.0% F.S./week (lowest range) |
| Response Time (T₉₀) | ≤180 s |
| Sample Flow Rate | ~0.7 L/min |
| Output Signals | 0–1 V / 0–10 V / 4–20 mA (configurable) |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (user-specified) |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~19 kg |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Instrument Type | Imported |
| Model | AquaLog |
| Wavelength Range (Excitation) | 200–800 nm |
| Wavelength Range (Emission) | 250–800 nm |
| Wavelength Range (Absorption) | 230–800 nm |
| Excitation Monochromator | Dual-grating with automatic order-sorting filter wheel |
| Emission Monochromator | CCD-based spectrometer with 405 g/mm grating (blazed at 250 nm) |
| Spectral Bandwidth (Slit) | 5 nm |
| Spectral Resolution | 0.41 nm/pixel (configurable to 0.82, 1.64, 3.28 nm/pixel) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio | >20,000:1 (RMS, 350 nm excitation, water Raman peak) |
| Full EEM Acquisition Time | 30 s |
| Full Emission Spectrum Readout Time | 5 ms |
| Detector | TE-cooled back-illuminated CCD |
| Built-in Corrections | Dark current, excitation source drift, excitation/emission spectral response, inner-filter effect, 1st/2nd-order Rayleigh scatter zeroing, Raman peak subtraction |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Aqualog® |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 5 nm |
| Optical Resolution | 0.58 nm |
| Sensitivity | 20,000:1 (SNR, RMS, water Raman at 350 nm excitation, 30 s integration) |
| Wavelength Accuracy | ±1.0 nm |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Auto SE |
| Spectral Range | 450–1000 nm |
| Incident Angle | 70° fixed |
| Detector | CCD array |
| Spot Size Options | 8 discrete sizes (automatically selectable) |
| Sample Stage | Motorized XYZ stage (200 mm × 200 mm travel, Z > 35 mm) |
| Optical Architecture | Liquid crystal phase modulation (no moving parts in measurement path) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-173 |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Conductivity Range | 0–199 µS/cm, 0.2–1.99 mS/cm, 2–19.9 mS/cm |
| Resolution | 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm |
| Accuracy | ±2% of reading |
| Salinity Range | 0–1.1% (w/w) |
| Temperature Compensation | Automatic, 5–35 °C with 2%/°C coefficient |
| Power Supply | Two 3V CR2032 batteries (approx. 500 hours lifespan) |
| Dimensions | 15 × 2 × 2 cm (L × W × H) |
| Included | Calibration standard solution (1410 µS/cm KCl) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-712 |
| Measurement Principle | Glass Electrode Method |
| pH Range | 2.0–12.0 |
| Accuracy | ±0.1 pH (after calibration, using standard buffer solutions) |
| Calibration | 1-point or 2-point automatic calibration |
| Minimum Sample Volume | 0.05 mL (with optional sampling film B) or ≥0.1 mL |
| Temperature Compensation | Automatic (ATC) |
| Auto-Hold Function | Yes |
| Ingress Protection | IP67 (1 m submersion for 30 min |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Power Supply | Two CR2032 lithium batteries |
| Dimensions (L×W×H) | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | Approx. 50 g (instrument only, excl. batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Measurement Principle | Ion-selective Electrode Method |
| Salinity Range | 0.1–10% (NaCl, w/w) |
| Temperature Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Resolution | 0.1% |
| Minimum Sample Volume | 0.05 mL × 2 or ≥0.3 mL |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| Auto-Hold Function | Yes |
| Ingress Protection | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | ~50 g (instrument only, excl. batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.0–10% (NaCl) |
| Conductivity Range | 0–19.9 mS/cm |
| TDS Range | 0–9900 ppm |
| Resistivity Range | 0–19.9 mS/cm (expressed as reciprocal conductivity) |
| Temperature Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% (salinity), 0.1 mS/cm (conductivity), 1 ppm (TDS), 0.1 °C (temperature) |
| Calibration | Two-point calibration with NaCl standard solutions |
| Temperature Compensation | Automatic, fixed 2%/°C coefficient |
| Ingress Protection | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | Approx. 50 g (instrument only, batteries excluded) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.1–10% (w/w NaCl) |
| Temperature Measurement Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| IP Rating | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, batteries excluded) |
| Measurement Principle | Ion-selective electrode (ISE) method for NaCl-specific salinity |
| Sample Volume | 0.05 mL × 2 or ≥0.3 mL |
| Calibration | Two-point calibration with standard NaCl solutions |
| Compliance | Designed for field and lab use under ISO 8665, ASTM D1125, and USP <645> environmental constraints |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Measurement Principle | Ion-selective electrode (NaCl-specific) |
| Salinity Range | 0.1–10% (w/w NaCl) |
| Temperature Range | 5–40 °C |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| Accuracy | ±10% of reading |
| Resolution | 0.1% |
| IP Rating | IP67 |
| Power Source | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe tip) |
| Weight | ~50 g (instrument only, no batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.1–10% (w/w NaCl) |
| Temperature Measurement Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% |
| Temperature Compensation | Automatic, fixed 2%/°C coefficient |
| Protection Rating | IP67 |
| Power Source | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | ~50 g (instrument only, excluding batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.1–10% (w/w NaCl) |
| Temperature Measurement Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| IP Rating | IP67 |
| Power Source | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, excluding batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Measurement Principle | Ion-Selective Electrode Method |
| Salinity Range | 0.1–10% w/w (based on specific gravity) |
| Temperature Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Resolution | 0.1% |
| IP Rating | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-721 |
| Portability | Pen-type |
| Salinity Measurement Range | 0.1–10% (w/w NaCl) |
| Temperature Measurement Range | 5–40 °C |
| Accuracy | ±10% of reading |
| Minimum Resolution | 0.1% |
| Temperature Compensation | Automatic (2%/°C fixed coefficient) |
| IP Rating | IP67 |
| Power Supply | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. probe protrusion) |
| Weight | Approx. 50 g (instrument only, excl. batteries) |