Kyocera
Filter
Showing 31–60 of 64 results
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-2100 |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Max Operating Pressure | 40 MPa (5800 psi) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Sample Capacity | Up to 768 positions (384-well MTP × 2) |
| Column Oven Temperature Range | (Ambient −10) °C to 85 °C (CTO-20AC) |
| UV-Vis Wavelength Range | 190–700 nm |
| Baseline Noise | ≤2 × 10⁻⁵ AU (254 nm, methanol, 1.0 mL/min, 60 min warm-up) |
| Drift | ≤4 × 10⁻⁵ AU/h |
| LOD (Naphthalene) | ≤1 × 10⁻⁹ g/mL |
| Data Acquisition Rate | 500 ms (LCsolution-compatible) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LC2000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.002–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | Not Specified (Front-Panel Manual Injection Interface) |
| Injection Volume Range | Not Specified |
| Column Oven Temperature Control Range | Not Specified |
| Wavelength Range (UV/VIS Detector) | 190–700 nm |
| Data Acquisition Frequency | Not Specified |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | LC2100 |
| Pricing | Upon Request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LC2200 |
| Price | Upon Request |
| Pump Flow Range | 0.001–10.0 mL/min |
| Max Pressure | 6000 psi |
| Pump Accuracy | ±1% at 1 µL/min |
| Pump Precision | ±0.25% (0.1–10.0 mL/min) |
| UV Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | <6 nm |
| Baseline Noise | <±2×10⁻⁵ AU |
| Baseline Drift | <4×10⁻⁴ AU (p-p) |
| D₂ Lamp Lifetime | 3500 h (1000 h warranty) |
| UV Detector Output | 0.0005–4 AU/mV (chart recorder), 4 AU/V (data system) |
| Power Supply (Pump) | 85–264 VAC, 47–63 Hz, 60 W |
| Power Supply (UV Detector) | 100–240 VAC, 50–60 Hz, 80 W |
| Dimensions & Weight | Pump — 5.9 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC3000A |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Maximum Pressure (P3210) | 42 MPa |
| Maximum Pressure (P3220) | 30 MPa |
| Flow Rate Range (P3210) | 0.001–9.999 mL/min |
| Flow Rate Range (P3220) | 0.01–49.99 mL/min |
| Flow Accuracy | ≤0.4% |
| Flow Precision (RSD) | ≤0.1% |
| UV/VIS Detector (UV3000A) | Wavelength Range 190–700 nm |
| Light Source | Deuterium Lamp (standard), Tungsten Lamp (optional) |
| Wavelength Accuracy | ≤±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Absorbance Range | 0–2 AU |
| Absorbance Error | <±5% |
| Baseline Noise (254 nm) | ≤1.5×10⁻⁵ AU (dynamic, 1 mL/min, MeOH/H₂O 80:20) |
| Baseline Drift (254 nm) | ≤4×10⁻⁴ AU/h (dynamic, 1 mL/min, MeOH/H₂O 80:20) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Auto-Zero Function | Full-scale |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC3000A Preparative Liquid Chromatograph |
| Max. Pressure (P3210) | 42 MPa |
| Max. Pressure (P3220) | 30 MPa |
| Flow Rate Range (P3210) | 0.001–9.999 mL/min |
| Flow Rate Range (P3220) | 0.01–49.99 mL/min |
| Flow Accuracy | ≤0.4% |
| Flow Precision (RSD) | ≤0.1% |
| UV/VIS Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ≤±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Absorbance Range | 0–2 AU |
| Absorbance Error | <±5% |
| Baseline Noise (254 nm) | ≤1.5×10⁻⁵ AU (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Baseline Drift (254 nm) | ≤4×10⁻⁴ AU/h (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Scan Modes | Programmable stop-and-go wavelength scanning (start/end λ and step size user-definable) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | PTC-30A |
| Sample Capacity | 30-position |
| Instrument Type | Water-and-Soil Integrated Purge and Trap System |
| Dehumidification Trap Temp Range | Ambient to 240 °C (1 °C increments) |
| Valve & Transfer Line Temp Range | Ambient to 220 °C (1 °C increments) |
| Trap Cooling/Desorption Temp Range | −30 °C to 400 °C (electronic cooling, 1 °C increments) |
| Sample Heating Temp Range | Ambient to 240 °C (1 °C increments) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Sample Vial | 40 mL |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SP-7800 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical GC |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | Ambient + 4 °C to 450 °C |
| Injector Pressure Setting Range | 0–100 psi (optional 0–150 psi) |
| Injector Total Flow Setting Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | SP6890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Control Channels | 4 independent zones |
| Temperature Stability | ±0.1 °C |
| FID Detection Limit | ≤5.0×10⁻¹¹ g/s (benzene/CS₂) |
| TCD Sensitivity | ≥2500 mV·mL/mg (benzene) |
| Dimensions | 470 × 430 × 455 mm |
| Weight | ~45 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP690 |
| Price | USD 2,100 (FOB Beijing) |
| Standard Compliance | JB/T 6244–1992, JJG 700–1990 |
| Temperature Control Zones | Column Oven, TCD Detector, FID Detector, Methanizer |
| Temperature Range | 7 °C above ambient to 399 °C |
| Temperature Stability | ±0.1 °C at 200 °C |
| Detection Modes | TCD, FID (with optional methanizer) |
| Sample Introduction | Split/splitless injector, compatible with headspace, purge-and-trap, vacuum degassing, and shaking degassing systems |
| Analytical Capability | Simultaneous quantification of C₁–C₂ hydrocarbon gases (H₂, O₂, N₂, CH₄, CO, CO₂, C₂H₄, C₂H₆, C₂H₂) in transformer oil per IEC 60599 and ASTM D3612 |
| Data Acquisition | Dual-channel auto-switching, baseline correction, peak integration, retention time locking |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP6900 |
| Application Field | Petrochemical Industry |
| Temperature Control | 5 independent zones, 5-step programmable ramping |
| Column Oven Range | Ambient +15°C to 399°C |
| Temperature Stability | Better than ±0.1°C |
| Heating Rate | 0.1–40°C/min |
| Time Programming | 0–255 min per step |
| TCD Sensitivity | ≥3500 mV·mL/mg (benzene) |
| Baseline Noise | ≤0.02 mV |
| Drift | <0.1 mV/h |
| Weight | ~60 kg |
| Sample Introduction | 6-port gas sampling valve |
| Data Output | Real-time purity and component quantification via PC interface |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | SP7800 |
| Pricing | Available Upon Request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Industrial GC System |
| Model | SP7800II |
| Pricing | Available Upon Request |
| Detection Principle | Capillary/Packed Column Gas Chromatography with TCD/FID/PID Detector Options |
| Sample Introduction | Automated Valve-Actuated Loop Injection or Manual Gas Bag Sampling |
| Column Configuration | Triple-Column Parallel Setup with Programmable Multi-Position Valves |
| Temperature Control | Dual-Zone Oven with ±0.1 °C Stability |
| Detection Limits | CO, C₂H₂, C₂H₄ ≤ 1 ppm (v/v) |
| TCD Sensitivity | ≥ 5000 mV·mL/mg |
| System Accuracy | ≤ 1% RSD (Relative Standard Deviation) |
| Compliance Standards | GB/T 13610–2003, GB/T 11062–1998, SH/T 0230–92, GB/T 12206–2006, GB 10410.1–89, GB 10410.2–89, GB 10410.3–89 |
| Data Output | Real-Time Reporting via Embedded PC, USB/RS-232/Ethernet Connectivity, Optional 21 CFR Part 11-Compliant Software Module |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | TP-6000 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 450 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 210 °C (1 °C increment) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 9 positions |
| Vial Size | 10 mL |
| Temperature Stability | < ±0.5 °C |
| RSD for Peak Area | ≤1.5% (under optimized conditions) |
| Equilibration/Injection/Clean Time Range | 0–60 min (user-programmable) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | WS-1 |
| Price | Upon Request |
| Display | 4-digit LED, microgram (µg) resolution |
| Water Quantification Range | 5 µg – 30 mg H₂O |
| Detection Limit | 1 µg H₂O |
| Accuracy | ±3 µg for 5–1000 µg |
| Electrolysis Current | 0–300 mA (auto-controlled) |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Power Consumption | <40 VA |
| Operating Temperature | 5–40 °C |
| Operating Humidity | ≤85% RH |
| Dimensions (W×D×H) | 450 × 230 × 200 mm |
| Weight | ~7 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | WX-AA7000 |
| Service Fee | USD 700–1,400 (excl. parts) |
| Technician Experience | 10 Years |
| Instrument Type | Analytical Instrument |
| Response Time | ≤12 Hours |
| Scope | AAS & Spectrometer Maintenance, Calibration, Component Replacement, System Diagnostics |
| Location | Beijing, China |
| Brand | Kyocera |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Reseller |
| Import Status | Imported Instrument |
| Model | WX-ABI3730XL |
| Service Fee | USD 5,000–10,000 (Quotation Required) |
| Technician Experience | 10 Years |
| Instrument Category | Analytical Instrument |
| Response Time | Within 12 Hours |
| Service Scope | ABI 3730XL Sequencer Repair, Calibration, and Preventive Maintenance |
| Service Location | Beijing, China |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | WX-AFS-9700 |
| Service Fee | USD 700–1,400 (excl. parts) |
| Field Experience | 10 years |
| Instrument Type | Analytical Instrument |
| Response Time | ≤12 hours |
| Service Scope | Preventive Maintenance, Fault Diagnosis, Component Replacement, System Calibration, Performance Validation |
| Location | Beijing, China |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | WX-LC |
| Service Fee | USD 1,400–2,800 (excl. parts) |
| Field Experience | 10 years |
| Instrument Type | Analytical Instrument |
| Response Time | Within 12 hours |
| Service Scope | HPLC Maintenance & Repair |
| Service Location | Beijing, China |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor & Service Provider |
| Product Category | Domestic Instrument |
| Model | WX-LC-2010 |
| Service Fee | USD 700–1,400 (excl. parts) |
| Field Experience | 10 years |
| Instrument Type | Analytical Instrument |
| Response Time | ≤12 hours |
| Scope | Preventive Maintenance, Fault Diagnosis, Component-Level Repair, System Validation |
| Location | Beijing, China |
| Compliance Support | GLP/GMP-aligned documentation available upon request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor & Service Provider |
| Instrument Type | Analytical Instrument (Atomic Absorption Spectrometer) |
| Model | WX-TAS-990 |
| Service Response Time | ≤12 hours |
| Years of Specialized AAS Service Experience | 10+ |
| Service Scope | Comprehensive maintenance, fault diagnosis, optical alignment, flame/graphite furnace module calibration, nebulizer & burner head refurbishment, electronics board diagnostics, software validation, and performance verification per ASTM E275 and ISO/IEC 17025 requirements |
| Geographic Coverage | On-site service across Beijing |
| Compliance Support | Documentation aligned with GLP, GMP, and CNAS-accredited laboratory requirements |
| Brand | Kyocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WX-AA-600 |
| Service Fee | USD 700–1,400 (excl. parts) |
| Field Experience | 10 Years |
| Instrument Type | Analytical Instrument |
| Response Time | ≤12 Hours |
| Service Scope | Comprehensive AAS Maintenance & Repair |
| Location | Beijing, China |
| Brand | Kyocera |
|---|---|
| Country of Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WX-AAnalyst800 |
| Service Fee | USD 700–1,400 (excl. parts) |
| Technician Experience | 10+ Years |
| Instrument Type | Analytical Spectrometer |
| Response Time | ≤12 Hours |
| Service Scope | AAS System Diagnostics, THGA Graphite Furnace Calibration, Optical Alignment, Lamp & Detector Optimization, Background Correction Verification, Software Revalidation (WinLab32), Compliance-Ready Documentation |
| Location | Beijing, China |
| Brand | Kyocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WX-AA-6300 |
| Service Fee | USD 700–1,400 (excl. parts) |
| Experience | 10 Years |
| Instrument Type | Analytical Instrument |
| Response Time | ≤12 Hours |
| Service Scope | AAS, UV-Vis, ICP-OES, Fluorescence Spectrometers |
| Location | Beijing, China |
| [Brand | Kyocera |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Third-Party Service Provider |
| Instrument Type | Analytical Instrument (Atomic Absorption Spectrometer) |
| Model | WX-AA-7000 |
| Service Response Time | ≤12 Hours |
| Service Coverage | Beijing, China |
| Experience | 10 Years Specializing in AAS Systems |
| Compliance | ASTM E2439, ISO/IEC 17025-Aligned Procedures, GLP-Ready Documentation Support |
| Software Compatibility | WizAArd v3.x and Later |
| Supported Configurations | Flame AAS, Graphite Furnace AAS, Autosampler Integration (GFAAS), Dual-Lamp Simultaneous Operation] |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Zl-GCMS-TQ8050 |
| Rental Rate | USD 700–1,400/month (FOB Beijing) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | WX-LC-10A |
| Service Fee | USD 700–1,400 (excl. parts) |
| Technician Experience | 10 Years |
| Instrument Type | Analytical Instrument |
| Response Time | ≤12 Hours |
| Service Scope | HPLC Maintenance, Calibration, Troubleshooting & Refurbishment |
| Location | Beijing, China |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | WX-LC-6AD |
| Service Fee | USD 700–1,400 (excl. parts) |
| Field Experience | 10 years |
| Instrument Type | Analytical Instrument |
| Response Time | ≤12 hours |
| Service Scope | HPLC System Maintenance, Troubleshooting, Calibration Support, and Refurbishment |
| Location | Beijing, China |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Business Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | WX-LCMS-2010EV |
| Service Fee | USD 700–1,400 per incident (excl. parts) |
| Technician Experience | 10 years on Shimadzu LC/MS platforms |
| Instrument Category | Analytical Instrumentation |
| Response Time | ≤12 hours (business days) |
| Service Scope | On-site repair, remote diagnostics, preventive maintenance, system refurbishment, short- to mid-term instrument leasing |
| Service Location | Beijing Metropolitan Area |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | WX-LCMS-8080 |
| Service Fee | USD 700–1,800 per incident (excluding parts) |
| Experience | 10 years in LC-MS/MS service |
| Instrument Type | Analytical Instrument |
| Response Time | ≤12 hours |
| Service Scope | Repair, Preventive Maintenance, Refurbishment, Short- to Medium-Term Rental |
| Location | Beijing, China |