Labthink
Filter
Showing 331–360 of 497 results
| Brand | Labthink |
|---|---|
| Model | MFY-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 1,400 – 4,200 |
| Vacuum Range | 0 to −90 kPa (Accuracy Class 1) |
| Vacuum Chamber Dimensions (Standard) | Φ270 mm × 210 mm (H) |
| Air Supply Requirement | 0.7 MPa via Φ6 mm polyurethane tubing |
| Power | AC 220 V, 50 Hz |
| Net Weight | 12 kg |
| Compliance | GB/T 15171, ASTM D3078 |
| Brand | Labthink |
|---|---|
| Model | MFY-01 |
| Origin | Jinan, Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Vacuum Range | 0 to –90 kPa |
| Accuracy Class | Grade 1 |
| Standard Vacuum Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Requirement | 0.7 MPa (user-provided) |
| Air Inlet | Φ6 mm polyurethane tubing |
| Overall Dimensions | 300 mm (L) × 380 mm (W) × 450 mm (H) |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 12 kg |
| Compliance Standards | GB/T 15171–1994, ASTM D3078–22 |
| Brand | Labthink |
|---|---|
| Model | MFY-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 1,400 – 4,200 |
| Vacuum Range | 0 to –90 kPa |
| Vacuum Accuracy | Class 1 |
| Standard Vacuum Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Optional Chamber Sizes | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Pressure | 0.7 MPa (user-provided) |
| Air Inlet Fitting | Φ6 mm Polyurethane Tubing |
| Brand | Labthink |
|---|---|
| Model | MFY-01 |
| Measurement Principle | Vacuum Decay Method |
| Standard Compliance | GB/T 15171, ASTM D3078 |
| Vacuum Range | 0 to –90 kPa |
| Accuracy Class | Class 1 |
| Vacuum Chamber Dimensions (Standard) | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Pneumatic Supply | 0.7 MPa (user-provided, Φ6 mm polyurethane tubing) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 12 kg |
| Dimensions (L×W×H) | 300 mm × 380 mm × 450 mm |
| Control System | Microprocessor-based with LCD interface |
| Key Functions | Automatic pressure compensation, timed vacuum hold, auto-release via reverse blow-off, programmable vacuum setpoint and dwell time |
| Actuation | Imported pneumatic components |
| Enclosure Material | Industrial-grade PVC front panel |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MFY-01 |
| Price Range | USD 1,400 – 4,200 |
| Vacuum Range | 0 to –90 kPa (Class 1 Accuracy) |
| Standard Vacuum Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Requirement | 0.7 MPa (user-provided) |
| Air Inlet | Φ6 mm polyurethane tubing |
| Overall Dimensions | 300 mm (L) × 380 mm (W) × 450 mm (H) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 12 kg |
| Compliant Standards | GB/T 15171, ASTM D3078 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink International Co., Ltd. |
| Model | MFY-01 |
| Vacuum Range | 0 to –90 kPa |
| Accuracy Class | Class 1 |
| Vacuum Chamber Dimensions (Standard) | Φ270 mm × 210 mm (H) |
| Pneumatic Supply Requirement | 0.7 MPa (user-supplied) |
| Air Inlet Fitting | Φ6 mm polyurethane tubing |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 12 kg |
| Compliance Standards | GB/T 15171, ASTM D3078 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MFY-01 |
| Price Range | USD 1,400 – 4,200 |
| Vacuum Range | 0 to −90 kPa |
| Accuracy Class | Class 1 |
| Vacuum Chamber Dimensions (Standard) | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Requirement | 0.7 MPa (user-provided) |
| Air Inlet | Φ6 mm polyurethane tubing |
| Overall Dimensions | 300 mm (L) × 380 mm (W) × 450 mm (H) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 12 kg |
| Compliant Standards | GB/T 15171, ASTM D3078 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | Labthink MFY-01 |
| Pricing | Available Upon Request |
| Vacuum Range | 0 to –90 kPa |
| Accuracy Class | Class 1 |
| Vacuum Chamber Dimensions (Standard) | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Pressure | 0.7 MPa (user-provided) |
| Air Inlet Fitting | Φ6 mm Polyurethane Tubing |
| Brand | Labthink |
|---|---|
| Model | MFY-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price | USD 2,150 (approx.) |
| Vacuum Range | 0 to –90 kPa |
| Accuracy Class | Class 1 |
| Standard Vacuum Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Requirement | 0.7 MPa (user-provided) |
| Air Inlet | Φ6 mm polyurethane tubing |
| Overall Dimensions | 300 mm (L) × 380 mm (W) × 450 mm (H) |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 12 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | MFY-01 |
| Vacuum Range | 0 to –90 kPa (±1% FS) |
| Accuracy Class | Grade 1 |
| Vacuum Chamber Dimensions (Std.) | Φ270 mm × 210 mm (H) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 12 kg |
| Air Supply Requirement | 0.7 MPa, Φ6 mm polyurethane tubing |
| Brand | Labthink |
|---|---|
| Model | MFY-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Price Range | USD 1,400 – 4,200 (FOB Qingdao) |
| Vacuum Range | 0 to –90 kPa |
| Accuracy Class | Class 1 |
| Standard Chamber Dimensions | Φ270 mm × 210 mm (H) (standard) |
| optional chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Requirement | 0.7 MPa, Φ6 mm polyurethane tubing interface |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 12 kg |
| Compliance | GB/T 15171, ASTM D3078 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MFY-01 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Vacuum Range | 0 to –90 kPa |
| Accuracy Class | Class 1 |
| Vacuum Chamber Dimensions (Standard) | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Requirement | 0.7 MPa, Φ6 mm polyurethane tubing |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 12 kg |
| Compliance | GB/T 15171, ASTM D3078 |
| Brand | Labthink |
|---|---|
| Model | MFY-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Vacuum Range | 0 to –90 kPa (±1% FS, Class 1 accuracy) |
| Vacuum Chamber Dimensions (Standard) | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Requirement | 0.7 MPa, Φ6 mm polyurethane tubing |
| Power Input | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 12 kg |
| Compliance | GB/T 15171, ASTM D3078 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MFY-01 |
| Price Range | USD 1,400 – 4,200 (FOB Qingdao) |
| Vacuum Range | 0 to –90 kPa |
| Accuracy Class | Class 1 |
| Vacuum Chamber Dimensions (Std.) | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Pressure | 0.7 MPa (user-provided) |
| Air Inlet | Φ6 mm polyurethane tubing |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 12 kg |
| Compliance | GB/T 15171, ASTM D3078 |
| Brand | Labthink |
|---|---|
| Model | MFY-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Vacuum Range | 0 to –90 kPa |
| Accuracy Class | Class 1 |
| Standard Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Requirement | 0.7 MPa, Φ6 mm polyurethane tubing |
| Power Input | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 12 kg |
| Dimensions (L×W×H) | 300 mm × 380 mm × 450 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MXD-01 |
| Price Range | USD 1,400 – 7,000 |
| Load Range | 0–5 N |
| Accuracy Class | Class 1 |
| Traverse Distance | 10 mm + 60 mm |
| Standard Sled Masses | 200 g, 500 g (1000 g optional) |
| Test Speed | 100 mm/min |
| Ambient Operating Conditions | 10–40 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 470 × 310 × 200 mm |
| Net Weight | 31 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | MXD-01 |
| Load Range | 0–5 N |
| Accuracy Class | Class 1 |
| Travel Distance | 10 mm + 60 mm |
| Slider Mass Options | 200 g, 500 g (1000 g optional) |
| Test Speed | 100 mm/min |
| Operating Environment | 10–40 °C, 20–70 %RH |
| Standards Compliance | GB 10006–1988, ISO 8295 |
| Interface | RS232 |
| Data Output | Built-in thermal printer, Lystem™ Lab Data Management System |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | MXD-01 |
| Load Range | 0–5 N |
| Accuracy Class | Class 1 |
| Travel Distance | 10 mm + 60 mm |
| Slider Mass Options | 200 g, 500 g (1000 g optional) |
| Test Speed | 100 mm/min |
| Temperature Range | 10–40 °C |
| Relative Humidity Range | 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 470 × 310 × 200 mm |
| Net Weight | 31 kg |
| Compliance | GB 10006, ISO 8295 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MXD-01 |
| Price Range | USD 1,400 – 7,000 |
| Standards Compliance | GB 10006, ISO 8295 |
| Load Range | 0–5 N |
| Accuracy Class | Class 1 |
| Travel Distance | 10 mm + 60 mm |
| Slider Mass Options | 200 g, 500 g (1000 g optional) |
| Test Speed | 100 mm/min |
| Ambient Temperature | 10–40 °C |
| Relative Humidity | 20–70 %RH |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 470 × 310 × 200 mm |
| Net Weight | 31 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | MXD-01 Static and Dynamic Coefficient of Friction Tester |
| Price Range | USD 1,400 – 7,000 |
| Load Range | 0–5 N |
| Accuracy Class | Class 1 |
| Travel Distance | 10 mm + 60 mm |
| Slider Masses | 200 g, 500 g (1000 g optional) |
| Test Speed | 100 mm/min |
| Environmental Operating Conditions | 10–40 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 470 × 310 × 200 mm |
| Net Weight | 31 kg |
| Compliance | GB 10006, ISO 8295 |
| Brand | Labthink |
|---|---|
| Model | MXD-02 |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Travel Distance | 70 mm / 150 mm |
| Standard Sled Mass | 200 g |
| Test Speeds | 100 mm/min, 150 mm/min |
| Environmental Conditions | 23 ± 2 °C, 20–70 %RH |
| Compliance Standards | ISO 8295, GB 10006, ASTM D1894, TAPPI T816 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MXD-02 |
| Price Range | USD 1,400 – 8,500 |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Travel Distance | 70 mm / 150 mm |
| Standard Sled Mass | 200 g (custom sleds available) |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Environmental Conditions | 23 ± 2 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 630 × 360 × 230 mm |
| Net Weight | 33 kg |
| Compliance Standards | ISO 8295, GB/T 10006, ASTM D1894, TAPPI T816 |
| Brand | Labthink |
|---|---|
| Model | MXD-02 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Travel Distance | 70 mm / 150 mm |
| Standard Slider Mass | 200 g (customizable) |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Ambient Conditions | 23 ± 2 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 630 × 360 × 230 mm |
| Net Weight | 33 kg |
| Compliance | GB 10006, ISO 8295, ASTM D1894, TAPPI T816 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | MXD-02 |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Stroke | 70 mm / 150 mm |
| Standard Sled Mass | 200 g (customizable) |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Environmental Conditions | 23 ± 2 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 630 × 360 × 230 mm |
| Net Weight | 33 kg |
| Compliance | ISO 8295, GB 10006, ASTM D1894, TAPPI T816 |
| Brand | Labthink |
|---|---|
| Model | MXD-02 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Traverse Distance | 70 mm / 150 mm |
| Standard Sled Mass | 200 g (custom sleds available) |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Operating Environment | 23 ± 2 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 630 × 360 × 230 mm |
| Net Weight | 33 kg |
| Compliance | GB 10006, ISO 8295, ASTM D1894, TAPPI T816 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Jinan Labthink Electromechanical Technology Co., Ltd. |
| Model | MXD-02 |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Travel Distance | 70 mm / 150 mm |
| Standard Slider Mass | 200 g (customizable) |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Operating Environment | 23 ± 2 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 630 × 360 × 230 mm |
| Net Weight | 33 kg |
| Compliance | ISO 8295, GB 10006, ASTM D1894, TAPPI T816 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | MXD-02 |
| Price Range | USD 1,400 – 8,500 |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Travel Distance | 70 mm / 150 mm |
| Standard Sled Mass | 200 g |
| Adjustable Test Speeds | 100 mm/min, 150 mm/min |
| Environmental Conditions | 23±2°C, 20–70% RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 630×360×230 mm |
| Net Weight | 33 kg |
| Compliance Standards | ISO 8295, GB 10006, ASTM D1894, TAPPI T816 |
| Brand | Labthink |
|---|---|
| Model | MXD-02 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 1,400 – 8,500 |
| Load Capacity | 0–5 N (Class 0.5 Accuracy) |
| Travel Distance | 70 mm / 150 mm |
| Standard Sled Mass | 200 g (custom sleds available) |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Operating Environment | 23 ± 2 °C, 20–70 %RH |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 630 × 360 × 230 mm |
| Net Weight | 33 kg |
| Compliance | ISO 8295, GB 10006, ASTM D1894, TAPPI T816 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MXD-02 |
| Price Range | USD 1,400 – 8,500 |
| Compliance | GB 10006, ISO 8295, ASTM D1894, TAPPI T816 |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Travel Distance | 70 mm / 150 mm |
| Standard Sled Mass | 200 g (customizable) |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Environmental Requirements | 23 ± 2 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 630 × 360 × 230 mm |
| Net Weight | 33 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Labthink MXD-02 |
| Price Range | USD 1,400 – 8,500 |
| Standards Compliance | GB 10006, ISO 8295, ASTM D1894, TAPPI T816 |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Travel Distance | 70 mm / 150 mm |
| Standard Sled Mass | 200 g (customizable) |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Environmental Conditions | 23 ± 2 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 630 × 360 × 230 mm |
| Net Weight | 33 kg |