| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CYZ-G |
| Instrument Type | Initial Adhesion Tester |
| Adjustable Inclination Angle | 0–60° |
| Tabletop Width | 120 mm |
| Test Zone Width | 80 mm |
| Standard Steel Balls | 1/32″ to 1″ (0.794 mm to 25.4 mm) |
| Dimensions (L×W×H) | 320 × 140 × 180 mm |
| Net Weight | 6 kg |
| Compliance Standards | GB/T 4852, JIS Z 0237 |
| Brand | Labthink |
|---|---|
| Model | CYZ-G |
| Testing Method | Inclined Plane Rolling Ball Method |
| Adjustable Incline Angle | 0–60° |
| Test Surface Width | 80 mm |
| Base Table Width | 120 mm |
| Standard Steel Balls | 1/32″ to 1″ (0.794 mm to 25.4 mm) |
| Dimensions (L×W×H) | 320 × 140 × 180 mm |
| Net Weight | 6 kg |
| Compliance | GB/T 4852, JIS Z 0237-2000 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Labthink CYZ-G |
| Pricing | Upon Request |
| Test Principle | Inclined Plane Rolling Ball Method |
| Adjustable Incline Angle | 0–60° |
| Tabletop Width | 120 mm |
| Test Zone Width | 80 mm |
| Standard Steel Balls | 1/32″ to 1″ (0.794 mm to 25.4 mm) |
| Dimensions (L×W×H) | 320 × 140 × 180 mm |
| Net Weight | 6 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CZY-6S |
| Instrument Category | Holding Power / Creep Resistance Tester |
| Voltage | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 600 × 240 × 400 mm |
| Net Weight | 20 kg |
| Test Stations | 6 |
| Standard Roller Mass | 2000 g ± 50 g |
| Applied Load | 1000 g ± 10 g (including loading plate) |
| Test Plate Dimensions | 60 mm (L) × 40 mm (W) × 1.5 mm (D) |
| Timing Range | 0–99 h (standard) |
| Compliance | GB/T 4851, ASTM D3654, JIS Z0237 |
| Brand | Labthink |
|---|---|
| Model | CZY-6S |
| Origin | Shandong, China |
| Manufacturer | Labthink Co., Ltd. |
| Application | ASTM D3654, GB/T 4851, JIS Z0237 |
| Test Principle | Vertical constant-load shear adhesion measurement under ambient conditions |
| Test Stations | 6 |
| Standard Weight Load | 1000 g ± 10 g (including loading plate) |
| Standard Roller | 2000 g ± 50 g |
| Test Plate Dimensions | 60 mm × 40 mm × 1.5 mm |
| Timing Range | 0–99 h (standard), up to 9999 h (optional) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 20 kg |
| Dimensions | 600 mm × 240 mm × 400 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CZY-6S |
| Standards Compliance | GB/T 4851, ASTM D3654, JIS Z0237 |
| Test Plate Dimensions | 60 mm × 40 mm × 1.5 mm |
| Standard Weight Load | 1000 g ±10 g (including loading plate) |
| Roller Mass | 2000 g ±50 g |
| Test Stations | 6 |
| Timing Range | 0–100 h (standard), up to 10000 h (optional) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 20 kg |
| Overall Dimensions | 600 mm × 240 mm × 400 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CZY-6S |
| Instrument Category | Holding Power Tester |
| Voltage | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 600 × 240 × 400 mm |
| Net Weight | 20 kg |
| Test Stations | 6 |
| Standard Roller Mass | 2000 g ± 50 g |
| Standard Weight Load | 1000 g ± 10 g (including loading plate) |
| Test Plate Dimensions | 60 mm (L) × 40 mm (W) × 1.5 mm (D) |
| Timing Range | 0–99 h (standard) |
| Compliance Standards | GB/T 4851, ASTM D3654, JIS Z0237 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | CZY-8SA |
| Instrument Classification | Holding Power Tester |
| Test Standards | GB/T 4851-2014, ASTM D3654, JIS Z0237 |
| Standard Roller Mass | 2000 g ± 50 g |
| Load Mass | 1000 g ± 5 g (including triangular hook) |
| Test Plate A Dimensions | 125 mm × 50 mm × 1.3 mm |
| Timing Range | 0–9999 h 59 min 59 s |
| Stations | 8 |
| Dimensions (L×W×H) | 900 mm × 315 mm × 544 mm |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz (dual-voltage selectable) |
| Net Weight | 25 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CZY-8SA |
| Instrument Category | Hold-Time Adhesion Tester |
| Power Supply | 220VAC±10% 50Hz / 120VAC±10% 60Hz (selectable) |
| Standard Roller Weight | 2000g ± 50g |
| Test Load | 1000g ± 5g (including triangular hook) |
| Test Plate A Dimensions | 125mm(L) × 50mm(W) × 1.3mm(D) |
| Timing Range | 0–9999 h 59 min 59 s |
| Test Stations | 8 |
| Overall Dimensions | 900mm(L) × 315mm(W) × 544mm(H) |
| Net Weight | 25 kg |
| Brand | Labthink |
|---|---|
| Model | CZY-8SA |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Holding Power Tester |
| Test Principle | Vertical Static Load Shear Adhesion Measurement |
| Standards Compliance | GB/T 4851-2014, ASTM D3654, JIS Z0237 |
| Test Stations | 8 |
| Load Mass | 1000 g ± 5 g (including triangular hook) |
| Standard Roller | 2000 g ± 50 g |
| Test Plate A Dimensions | 125 mm × 50 mm × 1.3 mm |
| Timing Range | 0–9999 h 59 min 59 s |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz (user-selectable) |
| Dimensions (L×W×H) | 900 mm × 315 mm × 544 mm |
| Net Weight | 25 kg |
| Data Storage Capacity | Up to 1200 test records |
| Environmental Monitoring | Real-time temperature & humidity logging with dual-unit display (°C/°F) |
| Optional Modules | Temperature-Controlled Chamber (23 °C / 38 °C precision), Horizontal Test Plate B, 4500 g Load Set, NIST SRM1810A Fibreboard, Micro Printer, GMP-Compliant Software Suite, DataShield™ Centralized Data Management System |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CZY-8SA Tack-Hold |
| Price Range | USD 1,400 – 7,000 |
| Instrument Category | Tack-Hold Adhesion Tester |
| Power Supply | 220 VAC ±10% 50 Hz / 120 VAC ±10% 60 Hz (selectable) |
| Test Stations | 8 |
| Standard Roller Weight | 2000 g ±50 g |
| Load Mass | 1000 g ±5 g (including triangular hook) |
| Test Plate A Dimensions | 125 mm (L) × 50 mm (W) × 1.3 mm (D) |
| Timing Range | 0–9999 h 59 min 59 s |
| Overall Dimensions | 900 mm (L) × 315 mm (W) × 544 mm (H) |
| Net Weight | 25 kg |
| Compliance Standards | GB/T 4851–2014, ASTM D3654, JIS Z0237 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | CZY-8SB |
| Price Range | USD 1,400 – 7,000 |
| Instrument Category | Holding Power Tester |
| Model | CZY-8SB |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CZY-8SB |
| Instrument Category | Holding Power Tester |
| Voltage | 220VAC±10% 50Hz / 120VAC±10% 60Hz |
| Dimensions | 900 mm (L) × 315 mm (W) × 544 mm (H) |
| Net Weight | 25 kg |
| Test Stations | 8 |
| Standard Roller | 2000 g ± 50 g |
| Test Weight | 1000 g ± 10 g (including loading plate) |
| Test Plate C | 125 mm × 125 mm × 1.7 mm (16 pcs) |
| Timing Range | 0–9999 h 59 min 59 s |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | CZY-8SB Pharmacopoeia Tack Hold Tester |
| Price Range | USD 1,400 – 7,000 |
| Instrument Category | Tack Hold Tester |
| Test Principle | Vertical static load adhesion retention measurement per pharmacopoeial method |
| Standards Compliance | Chinese Pharmacopoeia (2015 Edition), USP <1207>, ISO 29862:2017, ASTM D3654/D3654M |
| Temperature Control Option | Optional precision thermal chamber (23 °C ± 0.5 °C or 38 °C ± 0.5 °C) with Labthink’s proprietary active cooling technology |
| Test Stations | 8 independent vertical test positions |
| Load Application | 1000 g ± 10 g (including loading plate) |
| Standard Roller | 2000 g ± 50 g |
| Test Plate C Dimensions | 125 mm × 125 mm × 1.7 mm (16 pcs supplied) |
| Timing Range | 0–9999 h 59 min 59 s |
| Environmental Monitoring | Integrated temperature/humidity sensor with real-time curve logging |
| Data Storage Capacity | 1200 test records (onboard non-volatile memory) |
| Power Supply | 220 VAC ±10% / 50 Hz or 120 VAC ±10% / 60 Hz |
| Net Weight | 25 kg |
| Dimensions (L×W×H) | 900 × 315 × 544 mm |
| Interface Options | USB 2.0, optional thermal printer, optional DataShield™ data management system |
| Software Compliance | Audit trail, electronic signature, user role-based access control (21 CFR Part 11 ready with optional GMP-compliant software package) |
| Brand | Labthink |
|---|---|
| Model | CZY-G |
| Testing Principle | Inclined Plane Ball Rolling Method |
| Adjustable Incline Angle | 0–60° |
| Test Surface Width | 80 mm |
| Platform Width | 120 mm |
| Standard Steel Balls | 1/32″ to 1″ (0.794 mm to 25.4 mm) |
| Dimensions (L×W×H) | 320 × 140 × 180 mm |
| Net Weight | 6 kg |
| Compliance | GB/T 4852, JIS Z0237 |
| Brand | Labthink |
|---|---|
| Model | CZY-G |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Initial Adhesion Tester |
| Adjustable Inclination Angle | 0–60° |
| Test Surface Width | 120 mm |
| Effective Test Zone Width | 80 mm |
| Standard Steel Balls | 1/32″ to 1″ (0.794 mm to 25.4 mm) |
| Dimensions (L×W×H) | 320 × 140 × 180 mm |
| Net Weight | 6 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | CZY-G |
| Adjustable Inclination Angle | 0–60° |
| Table Width | 120 mm |
| Test Zone Width | 80 mm |
| Standard Steel Balls | 1/32″ to 1″ (0.794 mm to 25.4 mm) |
| Dimensions (L×W×H) | 320 × 140 × 180 mm |
| Net Weight | 6 kg |
| Compliance Standards | GB/T 4852, JIS Z 0237 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Instrument Manufacturer |
| Country of Origin | China |
| Model | CZY-GY |
| Pricing | Available Upon Request |
| Test Principle | Rolling Ball Method (Inclined Plane) |
| Adjustable Incline Angle | 0–45° |
| Tabletop Width | 120 mm |
| Test Zone Width | 80 mm |
| Standard Steel Balls | 1/32″ to 2″ (46 grades) |
| Dimensions (L×W×H) | 580 × 150 × 180 mm |
| Net Weight | 6 kg |
| Brand | Labthink |
|---|---|
| Model | CZY-GY |
| Measurement Principle | Rolling Ball Incline Method |
| Test Angle Range | 0–45° |
| Table Width | 120 mm |
| Test Zone Width | 80 mm |
| Standard Steel Balls | 1/32″ to 2″ (46 grades) |
| Dimensions (L×W×H) | 580 × 150 × 180 mm |
| Net Weight | 6 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | DV-Series (Modular Platform) |
| Price Range | USD 14,000 – 70,000 |
| Brand | Labthink |
|---|---|
| Model | EO Residual Detection System |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose EO residue quantification in sterilized medical devices |
| Oven Temperature Range | Ambient +3 °C to 399 °C |
| Oven Ramp Rate | 1–30 °C/min |
| Oven Cool-down Rate | ≤4 °C/min |
| Carrier Gas Flow Control Range | 0.1–5.0 mL/min (N₂ or He) |
| Carrier Gas Pressure Control Range | 0–200 psi |
| Injector Maximum Operating Temperature | 350 °C |
| Injector Pressure Setting Range | 0–200 psi |
| Injector Total Flow Setting Range | 1–50 mL/min |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ERT-01 |
| Pricing | Available Upon Request |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | ERT-01 |
| Pricing | Available Upon Request |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | FIT-01 |
| Impact Energy | 1 J, 2 J, 3 J |
| Impact Energy Resolution | 0.001 J |
| Puncture Tip Diameter | Φ25.4 mm, Φ19 mm, Φ12.7 mm (customizable) |
| Clamp Aperture | Φ89 mm, Φ60 mm |
| Specimen Size | 100 mm × 100 mm or Φ100 mm |
| Air Supply Pressure | 0.6 MPa |
| Air Interface | Φ6 mm polyurethane tubing |
| Dimensions (L×W×H) | 600 mm × 390 mm × 600 mm |
| Weight | 64 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Standard Configuration | Base pendulum (1 J), 2 J & 3 J add-on weights, Φ25.4 mm & Φ19 mm hemispherical tips, Φ89 mm & Φ60 mm clamp sets (with O-rings), micro-printer |
| Optional | Lystem™ Lab Data Management Software, RS232 communication cable, non-standard tips, replacement O-rings |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | FIT-01 |
| Instrument Category | Pendulum Impact Tester |
| Impact Energy | 1 J, 2 J, 3 J |
| Impact Velocity | Defined by pendulum geometry (Φ89 mm & Φ60 mm anvil diameters) |
| Pendulum Moment (Impact Constant) | Configurable via interchangeable pendulum arms with effective radii corresponding to Φ25.4 mm, Φ19 mm, and Φ12.7 mm hemispherical impactors |
| Force Sensor Resolution | 0.001 J |
| Maximum Lift Height | Calibrated for 1 J, 2 J, and 3 J energy levels |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | FIT-01 |
| Instrument Type | Pendulum Impact Testing Machine |
| Impact Energy | 1 J, 2 J, 3 J (standard) |
| Impact Velocity | Determined by pendulum drop height per ISO/GB standards (pneumatic release at 0.6 MPa air supply, user-provided) |
| Pendulum Moment (Impact Constant) | Configurable via interchangeable pendulum arms with nominal diameters Φ25.4 mm, Φ19 mm, Φ12.7 mm |
| Force Sensor Range | 1 J / 2 J / 3 J full-scale |
| Maximum Lift Height | Φ89 mm and Φ60 mm test clamp configurations |
| Sample Holder Diameter | Φ89 mm and Φ60 mm |
| Sample Size | 100 mm × 100 mm or Φ100 mm circular |
| Resolution | 0.001 J |
| Air Supply Interface | Φ6 mm polyurethane tubing (external 0.6 MPa source required) |
| Dimensions (L×W×H) | 600 mm × 390 mm × 600 mm |
| Net Weight | 64 kg |
| Compliance | GB/T 8809–1988, ASTM D3420–2008a, NF T54-116–1973 |
| Brand | Labthink |
|---|---|
| Model | FIT-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Impact Energy Range | 1 J, 2 J, 3 J (standard) |
| Resolution | 0.001 J |
| Impactor Tip Diameter | Φ25.4 mm, Φ19 mm, Φ12.7 mm (customizable) |
| Clamp Aperture | Φ89 mm, Φ60 mm |
| Specimen Size | 100 mm × 100 mm or Φ100 mm |
| Pneumatic Supply Pressure | 0.6 MPa (user-supplied) |
| Air Hose Interface | Φ6 mm polyurethane tubing |
| Dimensions (L×W×H) | 600 mm × 390 mm × 600 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 64 kg |
| Compliance | GB/T 8809–2014, ASTM D3420–2008a, NF T54-116–1973 |
| Brand | Labthink |
|---|---|
| Model | FIT-01 |
| Type | Pendulum Impact Testing Machine |
| Impact Energy | 1 J, 2 J, 3 J |
| Impact Energy Resolution | 0.001 J |
| Punch Diameter Options | Φ25.4 mm, Φ19 mm, Φ12.7 mm (customizable) |
| Clamp Aperture | Φ89 mm, Φ60 mm |
| Specimen Size | 100 mm × 100 mm or Φ100 mm |
| Air Supply Pressure | 0.6 MPa |
| Air Interface | Φ6 mm polyurethane tubing |
| Dimensions (L×W×H) | 600 mm × 390 mm × 600 mm |
| Weight | 64 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Standard Accessories | Base pendulum (1 J), 2 J & 3 J add-on weights, Φ25.4 mm & Φ19 mm punches, Φ89 mm & Φ60 mm clamp sets (with O-rings), micro-printer |
| Optional Accessories | Lystem™ Lab Data Management Software, RS232 communication cable, non-standard punches, replacement O-rings |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FIT-01 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Pendulum Impact Tester |
| Impact Energy | 1 J, 2 J, 3 J |
| Impact Velocity | Determined by pendulum arc geometry (standardized per ISO 179-1 & ASTM D3420) |
| Pendulum Moment (Impact Constant) | Configurable via interchangeable pendulum arms with effective lengths corresponding to Φ25.4 mm, Φ19 mm, and Φ12.7 mm radius-of-gyration equivalents |
| Force Sensor Range & Resolution | 0.001 J (energy resolution, derived from high-precision load cell and angular displacement integration) |
| Maximum Lift Height | Adjustable per energy level (1 J / 2 J / 3 J), calibrated to ISO-compliant pendulum geometry |
| Sample Clamp Aperture | Φ89 mm and Φ60 mm |
| Specimen Dimensions | 100 mm × 100 mm or Ø100 mm circular |
| Pneumatic Requirements | 0.6 MPa (user-supplied compressed air, Ø6 mm polyurethane tubing interface) |
| Overall Dimensions | 600 mm (L) × 390 mm (W) × 600 mm (H) |
| Compliance | GB/T 8809–2014, ASTM D3420–2008a, NF T54-116–1973, ISO 179-1 (adapted), ISO 8256 (indirect reference) |
| Brand | Labthink |
|---|---|
| Model | FIT-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Instrument Type | Pendulum Impact Tester |
| Impact Energy | 1 J, 2 J, 3 J |
| Energy Resolution | 0.001 J |
| Impactor Tip Diameter | Φ25.4 mm, Φ19 mm, Φ12.7 mm (customizable) |
| Clamp Aperture | Φ89 mm, Φ60 mm |
| Specimen Size | 100 mm × 100 mm or Φ100 mm |
| Pneumatic Pressure Requirement | 0.6 MPa (user-supplied air source) |
| Air Hose Connection | Φ6 mm polyurethane tubing |
| Dimensions (L×W×H) | 600 mm × 390 mm × 600 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 64 kg |
| Compliance Standards | GB/T 8809–1988, ASTM D3420–2013, NF T54-116 |