Labthink
Filter
Showing 181–210 of 497 results
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | C660M |
| Price Range | USD 4,200 – 7,000 (FOB Qingdao) |
| Test Range | 0–600 kPa (standard) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Nozzle Diameter | Φ10 mm (standard) |
| Airflow Control Range | 0.01–10 L/min |
| Hold Time | 0.1 s – 999,999.9 s |
| Air Supply Requirement | 0.6–0.7 MPa (clean, oil-free, dry air) |
| Interface | Φ8 mm polyurethane tubing |
| Dimensions (H×W×D) | 200 × 334 × 230 mm (main unit) |
| Power | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz (user-selectable) |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Compliance | ISO 11607-1/-2, ASTM F1140, ASTM F2054, GB/T 10440, GB 18454, GB 19741, GB 17447, YBB 00252005, YBB 00162002, BB/T 0025, QB/T 1871 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | C660M |
| Price Range | USD 1,400 – 4,200 |
| Test Principle | Positive Pressure Method |
| Standard Compliance | GB/T 10440–2008 |
| Test Range | 0–600 kPa (standard), up to 1.6 MPa (customizable) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Nozzle Diameter | Φ10 mm (standard), optional Φ4 mm / Φ1.6 mm |
| Airflow Control Range | 0.01–10 L/min |
| Hold Time | 0.1 s – 999999.9 s |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Dimensions (H/W/D) | 200 × 230 × 334 mm (main unit) |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Data Storage Capacity | 1200 test records |
| Interface | USB, optional thermal printer |
| Software Features | Multi-mode testing (burst, creep, creep-to-burst, pressure hold), real-time flow monitoring, touch-based OS with bilingual UI, audit-trail-ready data management (optional DataShield™), GLP/GMP-compliant data traceability (optional) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C660M |
| Test Range | 0–600 kPa (std), up to 1.6 MPa (optional) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Flow Rate | 0.01–10 L/min |
| Hold Time | 0.1 s – 999999.9 s |
| Standard Inflation Nozzle | Φ10 mm |
| Optional Nozzles | Φ4 mm, Φ1.6 mm |
| Air Supply Requirement | 0.6–0.7 MPa via Φ8 mm polyurethane tubing |
| Dimensions (H×W×D) | 200 × 334 × 230 mm (main unit) |
| Power | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Compliance | ISO 11607-1/2, ASTM F1140/F2054, GB/T 10440, GB 18454, YBB 00252005, etc. |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Labthink C660M Positive-Pressure Seal Integrity Tester |
| Price Range | USD 4,200 – 7,000 (FOB Qingdao) |
| Test Range | 0–600 kPa (standard) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Nozzle Diameter | Φ10 mm (standard) |
| Airflow Control | 0.01–10 L/min |
| Hold Time Range | 0.1 s – 999,999.9 s |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz (user-selectable) |
| Dimensions (H×W×D) | 200 × 334 × 230 mm (main unit) |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Compliance | ISO 11607-1, ISO 11607-2, ASTM F1140, ASTM F2054, GB/T 10440, GB 18454, GB 19741, YBB 00252005, YBB 00162002 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C660M |
| Test Range | 0–600 kPa (standard), up to 1.6 MPa (customizable) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Nozzle Diameter | Φ10 mm (standard), optional Φ4 mm / Φ1.6 mm |
| Airflow Control Range | 0.01–10 L/min |
| Hold Time | 0.1 s – 999999.9 s |
| Power Supply | 220 VAC ±10% 50 Hz or 120 VAC ±10% 60 Hz |
| Dimensions (H×W×D) | 334 × 230 × 200 mm (main unit) |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Compliance | ISO 11607-1, ISO 11607-2, ASTM F1140, ASTM F2054, GB/T 10440, GB 18454, YBB 00252005, YBB 00162002 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | C660M Positive-Pressure |
| Price Range | USD 4,200 – 7,000 |
| Test Range | 0–600 kPa (standard), up to 1.6 MPa (custom) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Nozzle Diameter | Φ10 mm (standard) |
| Airflow Control Range | 0.01–10 L/min |
| Hold Time | 0.1 s – 999999.9 s |
| Air Supply Requirement | 0.6–0.7 MPa (87–101 psi), Φ8 mm polyurethane tubing |
| Dimensions (H×W×D) | 200 × 334 × 230 mm (main unit) |
| Power | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Compliance | ISO 11607-1/-2, ASTM F1140/F2054, GB/T 10440, GB 17447, YBB 00252005, BB/T 0025, QB/T 1871 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C670M |
| Price | Upon Request |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | C670M |
| Type | Electromagnetic Release Dart Impact Testing System |
| Standards Compliance | ISO 7765-1:1988, ASTM D1709, GB/T 9639.1–2008, JIS K7124-1 |
| Test Methods | Method A (50–2000 g), Method B (300–2000 g) |
| Mass Resolution | ±0.5% |
| Specimen Clamp | Pneumatic (0.6 MPa required, Φ8 mm polyurethane tubing interface) |
| Specimen Size | ≥150 mm × 150 mm |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 70 kg |
| Dimensions (A-method) | 500 × 450 × 1320 mm (L×W×H) |
| Dimensions (B-method) | 500 × 450 × 2160 mm (L×W×H) |
| Interface | RS232 serial port, built-in thermal printer |
| Brand | Labthink |
|---|---|
| Model | C670M |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Test Methods | ASTM D1709 (Method A & B), ISO 7765-1:1988, GB/T 9639.1–2008, JIS K7124-1 |
| Measurement Range | Method A: 50–2000 g |
| Method B | 300–2000 g |
| Mass Resolution | ±0.5% |
| Sample Clamping | Pneumatic (0.6 MPa required, Φ8 mm polyurethane tubing interface) |
| Sample Size | >150 mm × 150 mm |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 70 kg |
| Dimensions (A Method) | 500 × 450 × 1320 mm (L×W×H) |
| (B Method) | 500 × 450 × 2160 mm (L×W×H) |
| Standard Configuration | Method A setup, 7″ color touchscreen HMI, built-in thermal printer |
| Optional Accessories | Method B conversion kit, Labthink SmartTest™ software suite, RS232 communication cable |
| Brand | Labthink |
|---|---|
| Model | C670M Dart |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Instrument Type | Dart Impact Tester |
| Testing Methods | ASTM D1709 (Method A & B), ISO 7765-1, GB/T 9639.1-2008, JIS K7124-1 |
| Measurement Range | Method A: 50–2000 g |
| Method B | 300–2000 g |
| Mass Accuracy | ±0.5% |
| Sample Clamping | Pneumatic (0.6 MPa required, Φ8 mm polyurethane tubing interface) |
| Sample Size | >150 mm × 150 mm |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 70 kg |
| Dimensions (A Method) | 500 × 450 × 1320 mm (L×W×H) |
| Dimensions (B Method) | 500 × 450 × 2160 mm (L×W×H) |
| Standard Configuration | Method A setup, 7-inch color touch screen, built-in thermal microprinter |
| Optional Accessories | Method B upgrade kit, Labthink IMPACTSuite™ software, RS232 communication cable |
| Brand | Labthink |
|---|---|
| Model | C670M |
| Application | ASTM D1709 / ISO 7765-1 / GB/T 9639.1 / JIS K7124-1 |
| Test Methods | Method A (50–2000 g), Method B (300–2000 g) |
| Mass Resolution | ±0.5% |
| Sample Clamping | Pneumatic (0.6 MPa required, Φ8 mm polyurethane tubing) |
| Sample Size | >150 mm × 150 mm |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 70 kg |
| Dimensions (Method A) | 500 × 450 × 1320 mm (L×W×H) |
| Dimensions (Method B) | 500 × 450 × 2160 mm (L×W×H) |
| Interface | RS232 serial port |
| Output | Built-in thermal printer, optional PC software with real-time graphing, multi-unit reporting, and audit-trail-capable data export |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C670M |
| Measurement Methods | A-Method (50–2000 g), B-Method (300–2000 g) |
| Mass Accuracy | ±0.5% |
| Specimen Size | >150 mm × 150 mm |
| Pneumatic Clamping Pressure | 0.6 MPa |
| Air Interface | Φ8 mm Polyurethane Tubing |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 70 kg |
| Dimensions (A-Method) | 500 × 450 × 1320 mm (L×W×H) |
| Dimensions (B-Method) | 500 × 450 × 2160 mm (L×W×H) |
| Standard Configuration | A-Method Assembly, 7″ Color Touchscreen, Integrated Thermal Printer |
| Optional Accessories | B-Method Kit, Labthink Professional Software, RS232 Communication Cable |
| Brand | Labthink |
|---|---|
| Model | C680M |
| Measurement Principle | Elmendorf tear method (pendulum-type energy absorption) |
| Test Range | 200–6400 gf (selectable pendulum capacities) |
| Pendulum Capacities | 200 gf, 400 gf, 800 gf, 1600 gf, 3200 gf, 6400 gf |
| Air Supply Requirement | 0.6 MPa (user-provided compressed air) |
| Air Inlet | Φ4 mm polyurethane tubing |
| Dimensions (L×W×H) | 480 × 380 × 560 mm |
| Weight | 23.5 kg (with 200 gf base pendulum) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 serial port |
| Compliance Standards | ISO 6383-1:1983, ISO 6383-2:1983, ISO 1974, GB/T 16578.2–2009, GB/T 455, ASTM D1922, ASTM D1424, ASTM D689, TAPPI T414 |
| Brand | Labthink |
|---|---|
| Model | C680M |
| Measurement Principle | Elmendorf Method (Pendulum-type Tear Resistance) |
| Compliance Standards | ISO 6383-1:1983, ISO 6383-2:1983, ISO 1974, GB/T 455, GB/T 16578.2–2009, ASTM D1922, ASTM D1424, ASTM D689, TAPPI T414 |
| Pendulum Capacities | 200 gf, 400 gf, 800 gf, 1600 gf, 3200 gf, 6400 gf |
| Air Supply Requirement | 0.6 MPa (user-provided), Φ4 mm polyurethane tubing interface |
| Dimensions (L×W×H) | 480 × 380 × 560 mm |
| Weight | 23.5 kg (with 200 gf base pendulum) |
| Power Input | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 serial port |
| Brand | Labthink |
|---|---|
| Model | C680M |
| Measurement Principle | Elmendorf Method |
| Standards Compliance | ISO 6383-1:1983, ISO 6383-2:1983, ISO 1974, GB/T 16578.2–2009, GB/T 455, ASTM D1922, ASTM D1424, ASTM D689, TAPPI T414 |
| Pendulum Capacities | 200 gf, 400 gf, 800 gf, 1600 gf, 3200 gf, 6400 gf |
| Pneumatic Clamping Pressure | 0.6 MPa |
| Air Interface | Φ4 mm polyurethane tubing |
| Dimensions (L×W×H) | 480 × 380 × 560 mm |
| Weight | 23.5 kg (with 200 gf base pendulum) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | C681M Flex Durability Tester |
| Quotation | Upon Request |
| Tumbling Frequency | 45 cycles/min |
| Test Modes | Mode A (2700 cycles), Mode B (900 cycles), Mode C (270 cycles), Mode D (20 cycles), Mode E (20 cycles, short stroke), Mode F (0–20,000 cycles, user-defined) |
| Applied Load | 300 N |
| Rotational Torque | 2 N·m |
| Max Sample Thickness | ≤2.5 mm (custom fixtures available) |
| Tumbling Angle | 440° or 400° |
| Horizontal Stroke | 155 mm or 80 mm |
| Stations | 4 |
| Sample Capacity | 1–4 specimens per run |
| Sample Size | 280 mm × 200 mm |
| Dimensions (L×W×H) | 760 mm × 410 mm × 650 mm |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz (dual-voltage configurable) |
| Net Weight | 85 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C681M |
| Frequency | 45 cycles/min |
| Test Modes | Mode A (2700 cycles), Mode B (900 cycles), Mode C (270 cycles), Mode D (20 cycles), Mode E (20 cycles, short stroke), Mode F (0–20,000 cycles, user-defined) |
| Applied Force | 300 N |
| Rotational Torque | 2 N·m |
| Specimen Thickness | ≤2.5 mm (custom fixtures available for thicker samples) |
| Oscillation Angle | 440° or 400° |
| Horizontal Stroke | 155 mm or 80 mm |
| Stations | 4 independent test stations |
| Sample Capacity | 1–4 specimens per run |
| Sample Size | 280 mm × 200 mm |
| Dimensions (L×W×H) | 760 mm × 410 mm × 650 mm |
| Power Supply | 220 VAC ±10%, 50 Hz OR 120 VAC ±10%, 60 Hz (dual-voltage configurable) |
| Net Weight | 85 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | C681M |
| Price | Upon Request |
| Rubbing Frequency | 45 cycles/min |
| Test Modes | Mode A (2700 cycles), Mode B (900 cycles), Mode C (270 cycles), Mode D (20 cycles), Mode E (20 short-stroke cycles), Mode F (0–20,000 cycles, user-defined) |
| Applied Load | 300 N |
| Rotational Torque | 2 N·m |
| Max Sample Thickness | ≤2.5 mm (custom fixtures available for thicker specimens) |
| Rubbing Angle | 440° or 400° |
| Horizontal Stroke | 155 mm or 80 mm |
| Number of Stations | 4 |
| Sample Quantity per Test | 1–4 |
| Sample Size | 280 mm × 200 mm |
| Dimensions (L×W×H) | 760 mm × 410 mm × 650 mm |
| Power Supply | 220 VAC ±10%, 50 Hz OR 120 VAC ±10%, 60 Hz |
| Net Weight | 85 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C690B |
| Pricing | Upon Request |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C690B |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay Method |
| Compliant Standards | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | −100 to 0 kPa |
| Chamber Capacity | 1 unit, max sample size Φ45 mm × 80 mm |
| Gas Supply | Compressed air (user-supplied), ≥40.6 PSI (500 kPa) |
| Interface | Φ6 mm polyurethane tubing |
| Dimensions | 250 × 330 × 440 mm |
| Power | 120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz (selectable) |
| Net Weight | 10 kg |
| Data Traceability | NIST-traceable pressure sensors |
| Software Compliance Options | 21 CFR Part 11 electronic signatures, GMP audit trail, multi-level user permissions |
| Brand | Labthink |
|---|---|
| Model | C690B |
| Principle | Vacuum Decay Method |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Test Range | 3–8 µm (USP <1207> reference orifice) |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | −100 to 0 kPa |
| Chamber Dimensions | ≤Φ45 mm × 80 mm |
| Sample Capacity | 1 unit per test |
| Air Supply | Compressed air ≥500 kPa (60 psi), Φ6 mm polyurethane tubing |
| Power | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions (W×D×H) | 250 × 330 × 440 mm |
| Weight | 10 kg |
| Interface | 12.1″ industrial touchscreen, USB port, optional thermal printer |
| Data Traceability | NIST-traceable pressure sensor, audit trail, optional 21 CFR Part 11 electronic signature and GMP-compliant software modules |
| Brand | Labthink |
|---|---|
| Model | C690H |
| Principle | Vacuum Decay Method |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Test Range | 3–8–Large Leak (Reference Orifice, USP <1207>) |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | −100 to 0 to +100 kPa |
| Sample Capacity | 20–120 units per batch |
| Max Sample Size | Ø45 mm × 80 mm |
| Gas Supply | Compressed Air (≥500 kPa / 72.5 psi) |
| Interface | Ø6 mm Polyurethane Tubing |
| Power | 120 VAC ±10% 60 Hz or 220 VAC ±10% 50 Hz |
| Dimensions | 850 × 500 × 730 mm |
| Weight | 95 kg |
| Vacuum Source | Integrated European Vacuum Pump |
| Data Traceability | NIST-Traceable Pressure & Flow Sensors |
| Software Platform | Windows-based Embedded OS with 15.6" Touchscreen |
| Optional Compliance Modules | 21 CFR Part 11 Electronic Signatures, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C690H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Principle | Vacuum Decay |
| Test Method | ASTM F2338–22, YY/T 0681.18–2022, USP <1207> |
| Sample Capacity | 20–120 units per batch |
| Test Chamber | Dual independent chambers (A & B) |
| Sample Size Limit | ≤ Φ45 mm × 80 mm |
| Pressure Range | –100 to +100 kPa |
| Detection Limit | ≤ 3 µm (equivalent reference orifice per USP <1207>) |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Gas Supply | Compressed air (user-supplied, ≥500 kPa / 72.5 psi) |
| Interface | Φ6 mm polyurethane tubing |
| Power Supply | 120 VAC ±10% 60 Hz OR 220 VAC ±10% 50 Hz (configurable) |
| Dimensions | 850 × 500 × 730 mm (W×D×H) |
| Net Weight | 95 kg |
| Compliance Options | Optional 21 CFR Part 11 electronic signature & audit trail module |
| Brand | Labthink |
|---|---|
| Model | C690H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Principle | Vacuum Decay Method (ASTM F2338–21 compliant) |
| Test Range | 3–8–Large Leak (USP <1207> Reference Orifice Equivalent) |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | –100 to 0 to +100 kPa |
| Sample Capacity | 20–120 units per batch |
| Max Sample Dimensions | Ø45 mm × 80 mm |
| Interface | Ø6 mm Polyurethane Tubing |
| Dimensions | 850 × 500 × 730 mm |
| Weight | 95 kg |
| Power | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (user-selectable) |
| Operating System | Embedded Windows on 15.6" Touchscreen |
| Data Compliance | 21 CFR Part 11–ready Electronic Signatures, Audit Trail, Role-Based User Access Control |
| Software Features | Real-time Pressure Curve Visualization, Automatic Pass/Fail Classification, Leakage Rate & Equivalent Orifice Diameter Calculation, Auto-Capture & Sorting of Non-Conforming Units, USB & Ethernet Connectivity, Remote Firmware Updates |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Labthink C690H |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay Method |
| Standards Compliant | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Range | 3–8–Large Leak (USP <1207> Reference Orifice) |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | −100 to 0 to +100 kPa |
| Sample Capacity | 20–120 units per run |
| Max Sample Dimensions | Ø45 mm × 80 mm |
| Brand | Labthink |
|---|---|
| Model | C690M |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay & Positive Pressure Decay |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Range | 2–8 µm (USP <1207> reference orifice scale) |
| Detection Limit | ≤2 µm |
| Resolution | 0.1 mPa·s (pressure-based equivalent) |
| Repeatability | ±1 µm (equivalent orifice size) |
| Pressure Range | −100 to +100 kPa |
| Test Chamber | 1 unit, swing-arm auto-sealing design |
| Max Sample Dimensions | Ø45 mm × 80 mm |
| Gas Supply | Compressed air (user-provided), ≥500 kPa (72.5 PSI) |
| Air Inlet | Ø6 mm polyurethane tubing |
| Dimensions (W×D×H) | 300 × 560 × 370 mm |
| Weight | 26 kg |
| Power | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (configurable) |
| Control System | 12.1″ embedded Windows touch panel PC |
| Data Traceability | NIST-traceable pressure sensors |
| Software Compliance | 21 CFR Part 11–ready audit trail, electronic signature, role-based user permissions |
| Optional | Integrated oil-free European vacuum pump, custom test fixtures, certified leak standards (positive/negative controls), GMP-compliant computer system validation package |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | C690M |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay & Pressure Decay |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Range | 2–8 µm (USP <1207> reference orifice scale) |
| Detection Limit | ≤2 µm |
| Resolution | 0.1 mPa·s (pressure-based equivalent) |
| Repeatability | ±1 µm (equivalent leak size) |
| Pressure Range | −100 to +100 kPa |
| Chamber | Single transparent swing-arm sealed chamber |
| Max Sample Size | Ø45 mm × 80 mm |
| Gas Supply | Compressed air (user-supplied, ≥500 kPa / 72.5 psi) |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions (W×D×H) | 300 × 560 × 370 mm |
| Weight | 26 kg |
| Power | 120 VAC ±10% 60 Hz OR 220 VAC ±10% 50 Hz (configurable) |
| Control System | 12.1" embedded Windows touch panel |
| Data Traceability | NIST-traceable pressure sensors |
| Software Features | Real-time pressure curve, auto-leak quantification, statistical reporting, USB/Ethernet connectivity, remote firmware update |
| Regulatory Support | 21 CFR Part 11 compliant electronic signatures, multi-level user permissions, audit trail, GMP-compliant validation documentation |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C690M |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay Method (ASTM F2338 compliant) |
| Dual-Mode Operation | Vacuum & Positive Pressure |
| Test Chamber | Swing-arm Auto-Clamping with Rapid Interchange |
| Target Vacuum Level | User-Configurable |
| Viewing Window | Transparent Acrylic Test Chamber |
| Vacuum Source | Optional Oil-Free European Vacuum Pump (NIST-Traceable Calibration Supported) |
| Pressure Sensor Technology | High-Stability Digital Transducer |
| Microflow Control | Automated Precision Flow Regulation |
| Data Traceability | Full Audit Trail, NIST-Referenced Calibration |
| Compliance | 21 CFR Part 11 Electronic Signatures, GMP Data Integrity Requirements, USP <1207>, YY/T 0681.18 |
| Operating System | Embedded Windows on 12.1" Touchscreen |
| Test Resolution | 0.1 mPa·s equivalent (leak rate), ±1 µm equivalent leak size repeatability |
| Test Range | Equivalent to 2–8 µm laser-drilled reference leaks (per USP <1207> guidance) |
| Max Sample Dimensions | Ø45 mm × 80 mm |
| Pressure Range | –100 to +100 kPa |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (configurable) |
| Net Weight | 26 kg |
| Footprint | 300 mm × 560 mm × 370 mm |
| Air Supply Requirement | Compressed air ≥500 kPa (72.5 PSI), Ø6 mm polyurethane tubing |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | C690M |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay & Pressure Decay |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Range | 2–8 µm (USP <1207> reference orifice scale) |
| Detection Limit | ≤2 µm |
| Resolution | 0.1 mPa·s (pressure-based equivalent) |
| Repeatability | ±1 µm (equivalent leakage orifice) |
| Pressure Range | −100 to +100 kPa |
| Test Chamber | 1 unit, swing-arm auto-sealing |
| Max Sample Size | Ø45 mm × 80 mm |
| Gas Supply | Compressed air (user-provided), ≥500 kPa (72.5 PSI) |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions (W×D×H) | 300 × 560 × 370 mm |
| Weight | 26 kg |
| Power | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (configurable) |
| Control System | 12.1" embedded Windows touch panel |
| Data Traceability | NIST-traceable pressure sensors, audit trail, electronic signature per 21 CFR Part 11 |
| Software Features | Real-time pressure curve display, automatic leak rate calculation, statistical reporting, USB/Ethernet connectivity, remote firmware update |
| Optional | GMP-compliant computer system validation package, integrated oil-free European vacuum pump, custom test fixtures, certified negative/positive reference standards |
| Brand | Labthink |
|---|---|
| Model | C840H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Pricing | Upon Request |