Lake Shore
Filter
Showing 1–30 of 72 results
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | DryMag |
| Temperature Range | 1.5 K to 300 K (420 K optional) |
| Magnetic Field | Up to 12 T vertical, up to 7 T horizontal |
| Cooling Method | Closed-cycle cryocooler with static helium exchange gas |
| Sample Environment | Top-loading, gas-cooled sample space |
| Optical Access | Optional bottom or horizontal viewport |
| Rotation Options | Single-axis (vertical) or dual-axis (vertical + horizontal) sample rotation |
| Base Temperature | ≤1.5 K |
| Initial Cool-down Time | ~24 h |
| Temperature Stability | ±50 mK |
| Sample Exchange Time | 90 min |
| Cryocooler Maintenance Interval | 10,000 h (Gifford-McMahon) or 20,000 h (pulse tube) |
| Optional Add-ons | He-3 insert (300 mK), electrical feedthroughs, M81-SSM source-measure unit, M91 FastHall controller, MeasureLINK software suite |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 240 |
| Channel Options | 2-channel (240-2P) or 8-channel (240-8P) |
| Temperature Range | 1 K to 800 K |
| Sensor Compatibility | Cernox®, Platinum RTDs, DT-670/DT-470 Diodes, Germanium, Carbon-Glass, RhFe, Rox™, GaAlAs |
| Excitation | 4-wire differential, constant current (10 µA) with polarity reversal |
| Isolation | Opto-isolated sensor inputs (channel-to-ground), non-isolated channel-to-channel |
| Communication | PROFIBUS-DP v1, USB 2.0 |
| Display | 128×32-pixel OLED, dual-parameter real-time readout (K/°C/°F/V/Ω), update rate: 2 Hz |
| Calibration | User-loadable 200-point curves per channel |
| Mounting | DIN-rail compatible, rear busbar for shared power & fieldbus |
| Compliance | CE, RoHS, PROFIBUS Nutzerorganisation (PNO) certified |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 372 |
| Type | Cryogenic AC Resistance Bridge & Dual-Channel Temperature Controller |
| Application | Sub-100 mK Dilution Refrigerator Thermometry and Sample/Heater Control |
| Compliance | Designed for GLP/GMP-aligned low-temperature physics labs |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 425 |
| Price | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 475 |
| Full-Scale Range | 35 mG to 350 kG |
| DC Resolution | 0.02 mG |
| Basic DC Accuracy | ±0.05% of reading ± 0.005% of range |
| Data Buffer | 1024 readings at up to 1000 samples/s |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 8400 Series |
| Magnetic Field Range | Up to 2.23 T (DC), 1.44 T (AC, 50 mm gap) |
| Temperature Range | 10 K–1273 K (with optional cryostats/furnaces) |
| Mobility Range | 1×10⁻³ to 1×10⁶ cm²/V·s (AC/DC) |
| Resistivity Range | 1×10⁻⁵ to 1×10⁵ Ω·cm |
| Standard Resistance Range | 0.5 mΩ–10 MΩ |
| High-Resistance Option | up to 200 GΩ |
| Low-Resistance Option | down to ~0.5 µΩ |
| AC Frequencies | 0.05 Hz and 0.1 Hz |
| Sample Geometry Support | Van der Pauw, Hall bar, 4-point probe |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 8600 |
| Magnet Type | Electromagnetic |
| Measurement Principle | Vibrating Sample Magnetometry (VSM) |
| Temperature Range | 10 K – 1273 K |
| Magnetic Field Range | Up to 3.62 T |
| Magnetic Moment Sensitivity | 5 × 10⁻⁸ emu |
| Field Sweep Rate | 10,000 Oe/s |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-100 |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum |
| Typical Cool-Down Time | 1–2 h |
| Vibration Level | Not Specified |
| Optical Window | Yes |
| Window Diameter | 83–85 mm |
| Cold Head Mounting | Flexible (User-Defined Orientation) |
| Recommended Compressor Maintenance Interval | 13,000 h |
| Approximate Height | 56–84 cm |
| Approximate Weight | 16–29 kg |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-300S |
| Cooling Type | Closed-cycle cryocooler |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cool-down Time | 1.5–2.5 h |
| Vibration Level | <40 nm (RMS) |
| Optical Window | Yes |
| Window Diameter | 38 mm to 85 mm |
| Cold Head Mounting | Flexible (user-configurable orientation) |
| Recommended Cryocooler Maintenance Interval | 13,000 hours |
| Approximate Height | 71–99 cm |
| Approximate Weight | 17–30 kg |
| Compliance | Designed for integration into ISO/IEC 17025-compliant labs and GLP/GMP-adjacent research environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-300ST |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cooling Time | 1.5–2.5 h |
| Design | Compact, Magnet-Compatible |
| Optical Window | None |
| Cold Head Mounting | Flexible (Arbitrary Orientation) |
| Approximate Weight | 17–30 kg |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-400 |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 500 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cool-down Time | 1.5–3 h |
| Optical Window | Yes (83–85 mm diameter) |
| Vibration Level | <40 nm (RMS) |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Dimensions (H) | 61–89 cm |
| Weight | 16–30 kg |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-400H |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | 5 K to 800 K |
| Sample Environment | High-Vacuum Chamber |
| Typical Temperature Stability | ±50 mK |
| Cooling Time (to base temperature) | 2–2.5 h |
| Optical Window Diameter | 83–85 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Vibration Level | <40 nm (RMS, at sample stage) |
| Cold Head Mounting | Flexible (top-mount configuration standard) |
| Weight | 16–30 kg |
| Height | 66–94 cm |
| Compliance | Designed for ASTM E220, ISO/IEC 17025-compliant lab environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-800 |
| Price | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4.5 K to 300 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange Gas (He) |
| Optical Window | Optional |
| Sample Loading | Top-Access |
| Sample Chamber Inner Diameter | 38 mm |
| Rotatable Sample Stage | Yes |
| Cool-Down Time | 2–2.5 h |
| Cryocooler Mounting | Bottom-Mounted |
| Vibration-Induced Linewidth Broadening | ≤0.01 mm/s (Δv/v) |
| Approximate Height | 142–168 cm |
| Weight | 27.2 kg (cryostat only) |
| Window Block Outer Diameter | 57.2 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Sample Exchange Time | ~5 min |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-900 |
| Quotation | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 800 K (2 K optional) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange Gas |
| Sample Types | Solid, Liquid, Powder |
| Sample Exchange Time | <10 min |
| Rotatable Sample Stage | Yes |
| Cool-down Time | 3–4 h |
| Cold Head Position | Top-Mounted |
| Optical Window | Standard (CCS-900), Optional (CCS-900-T) |
| Approximate Height | 114 cm (CCS-900), 114–168 cm (CCS-900-T) |
| Approximate Weight | 48 kg (CCS-900), 45–50 kg (CCS-900-T) |
| Sample Chamber Diameter | 38.1 mm |
| Customizable Chamber Dimensions | 28.6 mm, 38.1 mm, 60.3 mm |
| Window Block Diameter | 95.3 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-TRAP / CCS-TRAP-H |
| Pricing | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <8 K to 325 K / <9 K to 500 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum |
| Cool-down Time | 1–1.5 h |
| Cold Head Position | Bottom-Mounted |
| Approx. Height | 91.4 cm / 96.5 cm |
| Approx. Weight | 19.1 kg |
| Recommended Refrigerator Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-XG |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Vibration Level | <40 nm (RMS) |
| Typical Temperature Stability | ±50 mK |
| Cool-Down Time | 2–3 h |
| Optical Window Diameter | 83–85 mm |
| Approximate Height | 66–94 cm |
| Approximate Weight | 17–30 kg |
| Recommended Cold Head Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-XG-UHV |
| Price | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Ultra-High Vacuum (UHV) |
| Bake-Out Temperature (Cold Head Removed) | 200 °C |
| Cool-Down Time | 2–3 h |
| Vibration Level | <40 nm (RMS) |
| Cold Head Position | Top-Mounted |
| Optical Window | Not Standard |
| Approximate Height | 559–660 mm |
| Weight | Configuration-Dependent |
| Recommended Cold Head Maintenance Interval | 10,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | Cernox® |
| Temperature Range | 0.1 K to 420 K |
| Magnetic Field Error | Negligible above 30 K |
| Radiation Hardness | High |
| Thermal Response Time | As low as 1.5 ms @ 4.2 K (BC/BR/BG) |
| Encapsulation Options | SD (hermetic, sapphire-based), AA, BC, BG, BR, CD, ET, LR, MT, CO, CU, HT variants |
| Excitation Recommendation | 20 µV (0.1–0.5 K), 63 µV (0.5–1 K), ≤10 mV above 1.2 K |
| Power Dissipation | ~10⁻⁵ W @ 300 K, ~10⁻⁷ W @ 4.2 K, ~10⁻¹³ W @ 0.3 K |
| Long-Term Stability | ±3 mK @ 4.2 K |
| Compliance | Suitable for UHV, GLP/GMP-adjacent cryogenic metrology, ASTM E220, ISO/IEC 17025 traceable calibration workflows |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | CPX |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CPX-VF |
| Temperature Range | 1.9 K to 400 K |
| Magnetic Field | ±2.5 T (vertical, superconducting solenoid) |
| Sample Diameter | Up to 51 mm (2") |
| Vacuum Base Pressure | <5×10⁻⁷ Torr (with PS-HV-CPX) |
| Probe Capacity | Up to 6 arms |
| Microwave Frequency Range | DC–67 GHz |
| Positional Stability | <30 nm (with PS-PVIS option) |
| Hall Effect Measurement Capability | Yes |
| UHV & Transfer-Compatible Vacuum Chamber Options | Available |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CRX-4K |
| Temperature Range | 4.5 K to 350 K (optional up to 675 K) |
| Base Temperature | 4.5 K (2-probe configuration) |
| Vacuum Base Pressure | <1×10⁻⁵ Torr |
| Pumping System | TPS-FRG turbomolecular pump set |
| Sample Diameter | Standard 51 mm (2"), optional 102 mm (4") |
| Max Probe Count | 6 |
| DC/RF Probe Insulation | >100 GΩ |
| Microwave Frequency Range | DC to 67 GHz |
| Fiber-Optic Integration | Supported |
| Vibration Level | <1 µm |
| Landing Area | 25.4 mm diameter circle |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CRX-6.5K |
| Cooling Method | Two-Stage Closed-Cycle Refrigerator |
| Base Temperature | 8 K (2-probe configuration) to 10 K (6-probe configuration) |
| Temperature Control Range | 8.5–350 K (standard), extendable to 20–675 K with PS-HTSTAGE option |
| Vacuum Level | <5×10⁻⁴ Torr at room temperature, <1×10⁻⁵ Torr at base temperature, <5×10⁻⁵ Torr at max temperature |
| Sample Diameter Capacity | Up to 51 mm (2 in) |
| Probe Arm Capacity | Up to 6 arms |
| DC/RF Probe Insulation Resistance | >100 GΩ |
| Microwave Probe Frequency Range | DC to 67 GHz |
| Optical Fiber Probe Compatibility | Yes (for electro-optic measurements) |
| Landing Area | 25.4 mm diameter circle |
| Vibration Level | <2 µm RMS |
| Thermal Stability | ±25 mK (<10 K), ±10 mK (11–350 K), ±50 mK (351–675 K) |
| Total Cool-down Time | 6.25 h (including 0.5 h pump-down, 3.5 h cooling, 2.25 h warm-up) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CRX-EM-HF |
| Price | Upon Request |
| Temperature Range | 8 K to 400 K |
| Magnetic Field | ±0.6 T (horizontal, in-plane) |
| Max Sample Diameter | 25.4 mm (1 inch) |
| Vacuum Base Pressure | <1 × 10⁻⁵ Torr (at base temperature) |
| Probe Arms | Up to 4 |
| Sample Rotation | 360° optional |
| Probe Positioning Accuracy | <5 µm over full field sweep |
| DC/RF Insulation | >100 GΩ |
| Microwave Frequency Range | DC to 67 GHz |
| Optical Access | Fiber-coupled electro-optic probing supported |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRX-VF |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | CryoComplete |
| Pricing | Upon Request |
| Temperature Range | 77 K to 500 K |
| Resistance Measurement Range | 100 µΩ to 1 GΩ (standard) |
| Cryogen | Liquid Nitrogen |
| Vacuum Environment | Yes |
| Temperature Stability | ±50 mK |
| LN₂ Capacity | 1.2 L |
| Cool-down Time to 77 K | 15 min |
| Hold Time at 77 K | 8 h |
| Optical Windows | 4 quartz windows |
| Sample Mounting | Pre-wired 8-pin board |
| Measurement Modes | DC, AC (sine/triangle/square), lock-in (3 full channels) |
| Source Current Range | 1 pA to 100 mA |
| Source Frequency Range | 100 µHz to 100 kHz (square wave <5 kHz) |
| Max Measured Voltage | 10 V |
| Input Impedance | >10 GΩ (differential) |
| Sample Leakage Current | 50 pA @ 10 V (coaxial) or 50 fA @ 10 V (guarded triaxial) |
| Voltage Noise | <5 nV/√Hz @ 83 Hz |
| 1/f Voltage Noise (sample test) | <100 nV |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | CS Series |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Custom |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model Series | DT-670, Cernox® CX-1050/CX-1070, Rox™ RX-102B-RS/RX-102A, DT-621-HR, GR-100, CT-400, TC-E/K, Pt-100/200 |
| Temperature Range | 0.005 K to 1543 K (model-dependent) |
| Calibration | NIST-traceable, standard curves per IEC 60751 (Pt), ASTM E1137 (RTD), MIL-STD-883 (radiation) |
| Vacuum Compatibility | Up to 1×10⁻¹⁰ Pa (ultra-high vacuum) |
| Magnetic Field Tolerance | < ±0.1% reading up to 20 T (Cernox®, Rox™) |
| Radiation Hardness | Qualified to 1×10⁸ rad(Si) (Cernox®, GR-100, HR series) |
| Interchangeability | DT-670, Rox™, and Pt-series sensors comply with standardized resistance-vs-temperature curves (e.g., DT-670 curve, Rox™ Curve #1, Pt-100 DIN 43760) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | DT-670 |
| Temperature Range | 1.4 K to 500 K |
| Packaging Options | SD (hermetically sealed, sapphire-mounted), bare die (DT-670E-BR), non-magnetic (DT-621-HR) |
| Calibration Options | standard curve compliance (DT-670), full-range calibrated (DT-670-SD), low-temperature calibrated down to 1.4 K |
| Tolerance Bands | A, B, C, D (for 1.4–500 K), E (30–300 K), plus B/E bare-die variants |
| Forward Bias Current | 10 µA |
| Output Signal | monotonic voltage drop (0.1–6 V) |
| Mounting Compatibility | indium solderable, UHV-compatible, thermal-cycle robust |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | EMPX-H2 |
| Temperature Range | 3.2 K to 400 K |
| Magnetic Field | ±0.6 T (horizontal, in-plane) |
| Maximum Sample Diameter | 25.4 mm (1") |
| Magnetic Uniformity | 0.6% over Ø10 mm, 2.6% over Ø25 mm |
| Probe Position Stability | <5 µm across full field sweep |
| Vacuum Base Pressure | <1 × 10⁻⁵ Torr |
| Cooling Method | Continuous-flow cryogen (liquid He or N₂) |
| Sample Rotation | Optional 360° (PS-360-EMPX) |
| Probe Arms | Up to 4 |
| Microwave Frequency Support | DC–67 GHz |
| Electrical Isolation | >100 GΩ |
| Optical Integration | Fiber-coupled electro-optic measurement capability |