Lake Shore
Filter
Showing 31–60 of 72 results
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | F71 (3-axis), F41 (1-axis) |
| Measurement Range | 35 mT to 35 T |
| DC Accuracy | ±0.15% of reading (standard probe, 350 mT–3.5 T range) |
| AC Bandwidth | 550 Hz (–3 dB), HF Mode: 20 Hz–7 kHz (–0.2%) |
| Resolution | < 0.1 µT |
| Probe Compatibility | FP-Series Hall Probes only |
| Compliance | Designed for GLP/GMP environments with audit-ready data logging capability |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | FastHall Station |
| Pricing | Upon Request |
| Magnetic Field | 1 T (RT), 0.75 T (77 K) |
| Temperature Options | Room Temperature & Optional Liquid Nitrogen Cooling (77 K) |
| Resistance Range | 10 mΩ to 1 GΩ |
| Mobility Range | 0.01–10⁶ cm²/V·s |
| Resistivity Range | 1×10⁻⁵ to 10⁵ Ω·cm (typ.) |
| Carrier Concentration | 8×10² to 8×10²³ cm⁻³ (typ.) |
| Measurement Speed | <10 s per sample (typ.) |
| Sample Formats | Solder card (10×10×3 mm), Pin card (10×10×2 mm) |
| Hall Method | FastHall™ (field-reversal-free) and Van der Pauw / Hall bar configurations |
| Key | Brand: Lake Shore |
|---|---|
| Origin | USA |
| Model | FP Series Hall Probe |
| Field Range | Earth’s magnetic field to 35 T |
| Sensor Active Area | 0.1 mm² |
| Frequency Response | DC to 50 kHz |
| Output Type | Analog voltage (ratiometric or compensated) |
| Compensation | Built-in temperature and magnetic linearity compensation |
| Probe Form Factor | Handheld and mountable configurations |
| Axis Sensitivity | Axial, transverse, and triaxial options available |
| Calibration | NIST-traceable, factory-calibrated |
| Compliance | Designed for ASTM E1447, ISO/IEC 17025-compliant labs, compatible with Lake Shore F71/F41 Teslameters and 475/455/425 Gaussmeters |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | FWPX |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | GR-50-AA / GR-300-AA / GR-1400-AA |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported |
| Model | Hall Effect Sensor |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HR Series |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Infinite Helium |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | M81-SSM |
| Channel Configuration | 1–3 Source + 1–3 Measurement Channels |
| Frequency Range | DC to 100 kHz |
| Sampling Rate | 375 kSa/s |
| Dynamic Reserve | >120 dB |
| Phase Noise | <0.0001° RMS (internal ref, 10 kHz, 100 ms TC, 12 dB/oct) |
| THD | <0.1% (DC–100 kHz, typical) |
| Source Resolution | 6-digit frequency display, resolution >100 µHz |
| Measurement Modes | DC, AC RMS/peak, lock-in (X/Y, R/Θ), harmonic detection (up to 9th order) |
| Compliance Voltage/Current | ±10 V / ±100 mA (BCS-10, VS-10) |
| Input Bias Voltage | Near-zero (CM-10) |
| Voltage Sensitivity | Down to nV (VM-10) |
| Current Sensitivity | Down to fA (CM-10) |
| Interface | USB, Ethernet, GPIB |
| Display | 5″ capacitive touchscreen (800×480 WVGA) |
| Warm-up Time | 60 min to full specification |
| Isolation | Measurement common isolated from chassis ground |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | M91 |
| Measurement Principle | FastHall™ (patented single-direction magnetic field Hall effect analysis) |
| Compliance | ASTM F76, ISO/IEC 17025-compatible operation |
| Software Interface | LakeSHORE HallScan™ v3.2 with 21 CFR Part 11 audit trail support |
| Standard Resistance Range | 10 mΩ to 10 MΩ |
| Extended Range (with M9-ADD-HR option) | 10 mΩ to 200 GΩ |
| Carrier Mobility Range | 0.001–1×10⁶ cm²/(V·s) |
| Sample Configurations | Van der Pauw, Hall bar, cloverleaf |
| Magnetic Field Compatibility | DC fields up to ±16 T (superconducting magnet-ready) |
| Thermal Drift Mitigation | Sub-50 ms measurement window, active thermal compensation algorithm |
| Data Output Format | CSV, HDF5, XML |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MCS |
| Instrument Type | Variable-Temperature Hall Effect Tester |
| Constant Current Source Range | 1–20 mA |
| Mobility Range | 0.01–10⁶ cm²/V·s |
| Resistivity Range | 1×10⁻⁵ – 1×10⁵ Ω·cm |
| Carrier Concentration Range | 8×10² – 8×10²³ cm⁻³ |
| Typical Measurement Time | <10 s |
| Magnetic Field | 1 T (RT), 0.75 T (77 K) |
| Sample Dimensions (Max) | 10 mm × 10 mm × 3 mm (Solder Card) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Microscopy |
| Price | Upon Request |
| Magnetic Field | 0–7 T (Vertical Bore) |
| Bore Diameter | 42 mm (Room-Temperature Bore) |
| Temperature Range | 3.5 K to 325 K (420 K Optional) |
| Vacuum Environment | UHV-Compatible |
| Optical Access | Multiple Collinear & Off-Axis Ports |
| Sample Diameter Capacity | Up to 16 mm |
| Motion Control | High-Precision Motorized X-Y-Z Translation Stage |
| Compatible Cryostat | ST-500 High-Stability Microscope Cryostat |
| Primary Measurement Modalities | Micro-Raman, Photoluminescence (PL), Magneto-Optical Kerr Effect (MOKE) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 211 |
| Temperature Range | 1.4 K to 800 K |
| Input Channels | 1 |
| Sensor Types Supported | Silicon Diode, GaAlAs Diode, 100 Ω Pt, 1000 Ω Pt, Carbon-Glass, Cernox®, Rox™ |
| A/D Resolution | 24-bit |
| Measurement Update Rate | 7 Hz |
| Display Resolution | 0.001 K (0–99.999 K), 0.01 K (100–999.99 K), 0.1 K (>1000 K) |
| Display | 5-digit LED |
| Output Options | 0–10 V, 4–20 mA, Relay, RS-232/RS-485 Serial Interface |
| User Calibration Curves | 1 × 200-point non-volatile memory |
| Excitation Method | Constant-current, 4-wire differential |
| Isolation | Not chassis-ground isolated |
| Compliance | Designed for cryogenic vacuum and magnetic field environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 218 |
| Input Channels | 8 |
| Sensor Compatibility | Diode (Si, GaAlAs) and Resistance (Pt100, Pt1000, Germanium, Carbon-Glass, Cernox®, Rox™) |
| Temperature Range | 1.2 K to 375 K |
| Resolution | 0.001 K (0–99.999 K), 0.01 K (100–999.99 K), 0.1 K (>1000 K) |
| Update Rate | 16 readings/s total (2 full scans of all 8 channels per second) |
| Calibration Curves | 8 × 200-point user-definable curves |
| SoftCal™ Support | DT-470 diode (30–375 K, ±0.25 K improvement), Pt resistance (70–325 K, ±0.25 K improvement) |
| Interfaces | IEEE-488 (GPIB), RS-232C, dual analog voltage outputs, 8 relay outputs |
| Display | 4-line × 20-character backlit LCD |
| Excitation | 8 independent constant-current sources, 4-wire differential measurement |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 224 |
| Sensor Channels | 12 (2 dedicated, 10 multiplexed) |
| Operating Range | 300 mK to 375 K |
| Input Types | Cernox®, silicon diodes (e.g., DT-670), Pt RTDs (100 Ω / 1000 Ω), Rox™, germanium, carbon-glass |
| A/D Resolution | 24-bit |
| Update Rate | up to 10 readings/s (dedicated channels), 1–2 readings/s (scanned channels) |
| Isolation | optical isolation between sensor inputs and system ground |
| Calibration Storage | 39 user-defined 200-point curves |
| Display | 240 × 64 pixel LCD (8 × 40 characters), LED backlit |
| Interface | front-panel 6-pin DIN connectors |
| Compliance | designed for GLP/GMP-aligned lab environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 335 |
| Temperature Range | 0.3 K to 1505 K |
| Sensor Inputs | 2 standard (expandable to 4 with optional thermocouple card) |
| Control Outputs | 2 independent PID channels |
| Heater Power | 75 W total (configurable as 50 W + 25 W or 75 W + 1 W) |
| Interface | Ethernet, USB, IEEE-488 (GPIB) |
| Analog Output | ±10 V |
| Compliance | GLP/GMP-ready with audit-trail-capable logging via software |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 336 |
| Sensor Inputs | 4 (expandable to 8 with Scan Option) |
| Control Outputs | 4 (2 high-power, 2 low-power) |
| Max Heating Power | 150 W (100 W + 50 W) |
| Temperature Range | 0.3 K to 1505 K |
| PID Control | Digital, Auto-Tuning & Zone-Based |
| Supported Sensors | Diodes, RTDs (Pt100, Pt1000, Carbon-Glass, Cernox®, Rox™), Thermocouples (DT-470, DT-670, E, K, T, AuFe/Cr), Capacitance (with option card) |
| Interface | Ethernet, USB, IEEE-488 (GPIB) |
| Analog Output | ±10 V, 16-bit, 0.3 mV RMS noise |
| Display | 240 × 64 pixel graphical LCD |
| Compliance | GLP/GMP-ready architecture, supports audit trail via software logging |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 350 |
| Input Channels | 4 (expandable to 8 with Scan Option) |
| Sensor Compatibility | Cernox®, Rox™, DT-470, DT-670, PT-100/1000, carbon-glass, germanium, silicon diodes, thermocouples (with option cards), capacitive sensors |
| Measurement Range | 10 mK to 1000 K (sensor-dependent) |
| Excitation Current | As low as 10 nA for Cernox® |
| Noise Performance | Ultra-low-noise input circuitry optimized for ≤100 mK operation |
| Control Outputs | 4 independent PID-controlled outputs — Output 1: 75 W (25 Ω load), Output 2: 1 W (100 Ω load), Outputs 3 & 4: ±10 V analog (1 W max, 100 mA) |
| PID Auto-tuning | Per-loop, real-time adjustment |
| Current Reversal | Eliminates thermoelectric offset in resistive sensors |
| Compliance | CE certified |
| Interface | RS-232, USB, Ethernet (LXI-compliant) |
| Display | 240 × 64 pixel graphical LCD (8 × 40 characters), LED backlit |
| Data Logging | Local buffer + remote streaming at up to 10 Hz per active channel |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 480 |
| Interface | IEEE-488 (GPIB) & RS-232 |
| Input Channels | 1 |
| DC Resolution | 5¾ digits |
| AC Frequency Response | 2 Hz to 50 kHz |
| Max Input Voltage | 100 V (abs), 60 V (operational) |
| Input Impedance Options | 10 kΩ / 100 kΩ |
| DC Integration Capacitance | 1 µF (nominal) |
| AC Integration Capacitance | 0.1 µF (nominal) |
| DC Drift | ±1 µVs/min @ 300 mVs range (100 kΩ, constant-temp environment) |
| DC Accuracy | ±0.25% of reading + ±10 µVs offset |
| AC Accuracy | ±1% rdg ±10 µVs (10–10 kHz sine), ±5% rdg ±10 µVs (2–50 kHz sine) |
| Peak Capture Speed | Full-scale response <10 µs |
| Storage | Up to 10 coil calibration profiles |
| Display | 2-line × 20-character vacuum fluorescent display (VFD), 5 rdg/s update rate |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OptiMag |
| Pricing | Upon Request |
| Magnetic Field Range | 6–12 T (up to 16 T with optional configurations) |
| Temperature Range | 1.5–325 K |
| Sample Bore Diameter | 1.25–1.75 in |
| Helium Dewar Volume | 12 L |
| Hold Time (Static Cryogenic) | ~60 h |
| Field Homogeneity | ±0.5% to ±0.001% over 1 cm Ø sphere |
| Optical Access | Axial (bottom or top), along field direction |
| Cooling Environment | Continuous-flow cryogen or vacuum |
| Compatible Configurations | Vector magnet (2–3 independent coils), horizontal-field, Mössbauer-compatible vertical-drive with top-loaded source/absorber |
| Optional Add-ons | M81 Synchronous Source Transport Measurement System, M91 Fast Hall Probe System, He-3 Insert (<1.4 K), Lambda-point refrigerator (for 9–16 T systems) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | PS-100 |
| Temperature Range | 4.2 K to 475 K (standard), down to 3.2 K with PS-LT option |
| Sample Diameter | up to 32 mm (1.25 in) |
| Vacuum Base Pressure | <1 × 10⁻⁵ Torr |
| Vibration | <300 nm (standard), <30 nm with PS-PVIS option |
| Probe Arms | up to 4 |
| Cooling Method | Continuous-flow liquid helium or liquid nitrogen |
| Thermal Stability | ±15 mK typical at 4.4–100 K (liquid helium) |
| Electrical Isolation | >100 GΩ |
| RF/Microwave Capability | DC–67 GHz (with optional microwave probes) |
| Optical Access | Fiber-optic probe compatibility for electro-optical measurements |
| Drop-in Area | 25.4 mm diameter circular zone |
| Thermal Sinking | Probe arms actively cooled to <35 K at base temperature |
| Control System | Compatible with Lake Shore Model 336 Temperature Controller |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | PT-100 |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | RGC |
| Cooling Medium | Helium (gaseous & liquefied) |
| Operating Principle | Closed-loop cryogenic recirculation with pulse-tube or GM-based cold head |
| Compatible Cryostats | Lake Shore ST-100, ST-300, ST-400, ST-500, STVP series |
| Base Temperature (with ST-500) | ≤3.3 K (RGC4-20), ≤3.5 K (RGC4-15), ≤3.9 K (RGC4-12), ≤4.3 K (RGC4-10) |
| Cooling Power @ 5 K | up to 280 mW (RGC4-20) |
| Vibration Level (ST-500 + RGC) | <50 nm RMS (1–100 Hz) |
| Sample Exchange | Cold-insertion compatible (no warm-up required) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Room Temperature Bore Superconducting Magnet |
| Magnetic Field Range | 6–14 T |
| Bore Temperature | Ambient (300 K) |
| Sample Environment Options | Ambient Atmosphere, Vacuum, Ultra-High Vacuum (UHV), Cryogenic Insert Compatible (1.5 K – 800 K) |
| Optical Access | Optional Viewports |
| Bore Diameter | Customizable |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | Rox™ Series (RX-102A, RX-202A, RX-103A) |
| Temperature Range | 0.05 K to 40 K (RX-102A/RX-202A) |
| Resistance at 300 K | 1 kΩ (RX-102A), 2 kΩ (RX-202A), 10 kΩ (RX-103A) |
| Calibration Accuracy | ±16 mK @ 4.2 K (RX-102A/RX-202A) |
| Magnetic Field Tolerance | < 0.1% resistance shift in ≤ 12 T fields |
| Radiation Hardness | Qualified for neutron/gamma irradiation environments up to 1 × 10¹⁵ n/cm² (E > 1 MeV) |
| Thermal Dissipation | 7.5 × 10⁻⁸ W @ 4.2 K (RX-102A/RX-202A) |
| Time Constant | 0.5 s @ 4.2 K, 2.5 s @ 77 K |
| Repeatability | ±15 mK @ 4.2 K |
| Long-Term Stability | ±30 mK @ 4.2 K (RX-102A), ±50 mK (RX-202A), ±15 mK (RX-103A) |
| Compliance | NIST-traceable calibration, ISO/IEC 17025 accredited lab reporting, GLP-compliant documentation available |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | RX-102B-RS |
| Price | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | SHI-950 |
| Cooling Type | Closed-cycle refrigeration |
| Temperature Range | 1.5 K to 800 K (300 mK with optional He-3 insert) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange gas |
| Sample Types | Solid, liquid, powder |
| Sample Exchange Time | <10 min |
| Cool-down Time | 8–9 h |
| Sample Cooling Time | ~80 min |
| Cryocooler Mounting | Top-mounted |
| Rotation Capability | Yes |
| Optical Window | Standard (configurable) |
| Sample Chamber Diameter | 51 mm (customizable) |
| Window Block Size | 108 mm square (standard) |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Approximate Height | 142–168 cm |
| Approximate Weight | 113.4 kg |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ST Series |
| Pricing | Available Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-100 |
| Cooling Method | Liquid Helium or Liquid Nitrogen Continuous-Flow |
| Temperature Range | 2 K to 500 K (ST-100) / 2 K to 800 K (ST-100-H) |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (~10⁻⁵ Torr typical) |
| Optical Access | Yes, with standard optical windows |
| Cool-down Time | ≤15 min to 5 K |
| System Mass (excl. cryolines) | ~4.6 kg |
| Initial Cryogen Consumption (LHe, RT → base T) | 0.4 L |
| Steady-State LHe Consumption @ 5 K | 0.6 L/h |
| LN₂ Consumption @ 80 K | 0.1 L/h |
| Vacuum Requirement (initial) | ~10⁻³ Torr |
| Mounting Orientation | Omnidirectional |
| Sample Compatibility | Solid, thermally conductive specimens |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-300 |
| Temperature Range | 2 K to 500 K |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (Typical Operating Pressure: ~10⁻⁵ Torr) |
| Cooling Medium | Liquid Helium (down to 2 K) or Liquid Nitrogen (down to 77 K) |
| Cool-down Time to 5 K | ≤15 min |
| System Mass (excl. Transfer Lines) | ~4.6 kg |
| LN₂ Consumption @ 80 K | 0.1 L/h |
| LHe Consumption @ 5 K | 0.6 L/h |
| Initial LHe Fill (RT → Base Temp) | 0.4 L |
| Vacuum Requirement (Initial) | ~10⁻³ Torr |
| Optical Access | Standard Integrated Windows |
| Mounting Orientation | Omnidirectional |
| Compatibility | RGC Helium Recirculation Cryocooler (Helium-Free Operation) |