| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | DR Series |
| Digestion Positions | 15 / 24 / 40 / 54 / 77 |
| Temperature Range | Ambient to 260 °C |
| Temperature Control Accuracy | ±1.0 °C |
| Heating Principle | Infrared Radiant Heating |
| Heating Block Material | High-Purity Graphite with PTFE Coating |
| Control System | PID Digital Controller (30-Step Programmable Ramp/Soak) |
| Max Power | 1200 W (DR-15/DR-24), 3000 W (DR-54) |
| Sample Vessel Compatibility | Standard digestion tubes (e.g., 50 mL or 100 mL borosilicate or quartz) |
| Compliance | Designed for GLP-compliant sample preparation workflows |
| Brand | MICHEM |
|---|---|
| Model | DR-15 / DR-24 / DR-54 |
| Heating Material | PTFE-Coated Graphite |
| Max Temperature | 240 °C |
| Temperature Accuracy | ±1.0 °C |
| Heating Uniformity | ±2.0 °C across block |
| Control System | 30-Step PID Digital Programmable Controller |
| Sample Capacity | 15 × 100 mL (DR-15) |
| Power Rating | 1200 W (DR-15/DR-24) / 3000 W (DR-54) |
| Input Voltage | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 470×350×270 mm (DR-15/DR-24) / 670×460×270 mm (DR-54) |
| Compliance | Designed for ISO/IEC 17025-compliant sample preparation workflows |
| Application Scope | Acid digestion, post-microwave acid removal (acid evaporation), and controlled thermal pretreatment prior to AAS, AFSS, ICP-OES, and ICP-MS analysis |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DR Series High-Pressure Graphite Digestion System |
| Price Range | USD 1,400 – 7,200 |
| Instrument Type | Graphite Block Digester |
| Automation Level | Semi-Automatic |
| Digestion Positions | 6 or 8 (customizable) |
| Max Heating Temperature | 260 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Heating Principle | Infrared-Enhanced Graphite Block Heating |
| Heating Block Material | High-Purity Graphite with PTFE Coating |
| Pressure Rating | 10 MPa (dual-layer sealed digestion vessels) |
| Temperature Program Steps | Up to 30 segments |
| Max Power Consumption | 1.2 kW (DR-6G) / 3.0 kW (DR-8G) |
| Input Voltage | AC 220 V, 50 Hz, 10 A (DR-6G) / 16 A (DR-8G) |
| Dimensions (W×D×H) | 470×350×270 mm (DR-6G) |
| Sample Vessel Capacity | 100 mL × 6 or × 8 |
| Brand | MICHEM |
|---|---|
| Model | DR-15 |
| Heating Material | PTFE-coated graphite block |
| Max. Power | 1200 W |
| Control System | 30-step PID digital temperature controller |
| Max. Temperature | 240 °C |
| Temp. Accuracy | ±1.0 °C |
| Sample Capacity | 15 × 100 mL vessels |
| Well Dimensions | Φ42 × 40 mm (diameter × depth) |
| Temp. Uniformity | ±2.0 °C across wells |
| Power Supply | AC 220 V / 50 Hz / 10 A |
| Device Dimensions | 470 × 350 × 270 mm |
| Compliance | Designed for EPA, ASTM, and ISO-compliant sample preparation workflows |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | DR-15N |
| Digestion Capacity | 15 × 100 mL |
| Block Material | High-Purity Graphite with 6-Layer PTFE Coating |
| Heating Principle | Infrared Radiant Heating |
| Temperature Range | Ambient to 260 °C |
| Temperature Control | PID Digital Controller |
| Temperature Uniformity | ≤1 °C at 150 °C (inter-hole) |
| Temperature Accuracy | ±1.0 °C |
| Programmable Steps | Single-step or Optional 30-Step Ramp/Soak Profile |
| Max Power Consumption | 1200 W |
| Dimensions (W×D×H) | 650 × 430 × 220 mm |
| Electrical Supply | AC 220 V / 50 Hz / 10 A |
| Digestion Well Dimensions | Φ42 × 50 mm (customizable) |
| Compliance | EPA Method 3050B, 3051A, 3052 |
| Brand | MICHEM |
|---|---|
| Model | DR-35 |
| Sample Capacity | 35 positions |
| Digestion Well Dimensions | Ø31 × 50 mm |
| Heating Method | Infrared-heated graphite block |
| Heating Material | High-purity graphite with PTFE coating |
| Effective Heating Area | 470 × 314 mm |
| Temperature Range | RT to 260 °C |
| Temperature Uniformity | ≤1.0 °C between wells at 150 °C |
| Control System | 30-step PID programmable controller |
| Temperature Accuracy | ±0.1 °C |
| Max Power | 2500 W |
| Input Power | AC 220 V / 50 Hz / 10 A |
| Dimensions (W×D×H) | 770 × 520 × 200 mm |
| Weight | Approx. 48 kg |
| Optional Accessories | Borosilicate glass digestion tubes with reflux condensers (35 pcs), PTFE digestion cups (35 pcs), graphite sample racks, custom digestion vessel kits (glass/PTFE/PFA) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | DR-6G |
| Digestion Type | Graphite-block Electric Heating |
| Automation Level | Semi-Automatic |
| Digestion Positions | 6 or 8 |
| Max Temperature | 260 °C |
| Temperature Accuracy | ±1.0 °C |
| Heating Mechanism | Electric heating plate + graphite thermal conduction block + infrared auxiliary heating |
| Surface Coating | PTFE (Teflon®)-coated graphite |
| Rated Power | 1200 W (DR-6G) |
| Input Voltage | AC 220 V, 16 A |
| Dimensions (L×W×H) | 470×350×270 mm (DR-6G) |
| Sample Vessel Capacity | 100 mL × 6 or × 8 |
| Pressure Vessel Compatibility | Dual-layer sealed reaction vessels rated to 10 MPa |
| Compliance | Meets GB/T 150 (China National Standard for Pressure Vessels) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | DR-8H |
| Instrument Type | Crucible Furnace |
| Max Temperature | 260 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Max Power | 3000 W |
| Heating Rate | 260 °C (to max temp) |
| Heating Method | Electrical Resistance Heating |
| Internal Chamber Dimensions | 670 × 460 × 270 mm |
| Heating Block Material | High-Purity Graphite with PTFE Coating |
| Pressure Rating of Compatible Vessels | 10 MPa |
| Programmable Steps | 30-segment PID Profile |
| Sample Capacity | 8 × 100 mL High-Pressure Reactor Vessels |
| Power Supply | AC 220 V / 50 Hz, 16 A |
| Brand | MICHEM |
|---|---|
| Model | DR-15 / DR-24 / DR-54 |
| Heating Material | PTFE-Coated Graphite |
| Max Power | 1200 W (DR-15, DR-24) / 3000 W (DR-54) |
| Control | 30-Step PID Digital Temperature Controller |
| Max Temp | 240 °C |
| Temp Accuracy | ±1.0 °C |
| Sample Capacity | 15×100 mL (DR-15) / 24×50 mL (DR-24) / 54×50 mL (DR-54) |
| Well Dimensions | Φ42×40 mm (DR-15) / Φ26×40 mm (DR-24) / Φ23×40 mm (DR-54) |
| Power Supply | AC 220 V, 50 Hz, 10 A (DR-15/DR-24) / 16 A (DR-54) |
| Dimensions (W×D×H) | 470×350×270 mm (DR-15/DR-24) / 670×460×270 mm (DR-54) |
| Brand | MICHEM |
|---|---|
| Model | FS Series |
| Type | Graphite Block Digestion Instrument |
| Heating Block Material | High-Purity Graphite with PTFE Coating |
| Max. Temperature | 260 °C |
| Temp. Accuracy | ±0.2 °C |
| Heating Power | 1200 W (FS-I) / 3000 W (FS-II) |
| Programmable Steps | 30 |
| Sample Capacity | 6 × 100 mL (FS-I) / 8 × 100 mL (FS-II) |
| Pressure Rating of Digestion Vessels | 10 MPa |
| Compliance | Meets National Pressure Vessel Standards (China GB/T 150) |
| Power Supply | AC 220 V, 50 Hz, 10 A (FS-I) / 16 A (FS-II) |
| Dimensions (W×D×H) | 470×350×270 mm (FS-I) / 670×460×270 mm (FS-II) |
| Brand | MICHEM |
|---|---|
| Model | FS-II |
| Type | Infrared Heating Digestion System |
| Heating Block | PTFE-Coated High-Purity Graphite |
| Max Power | 3000 W |
| Control System | PID Digital Temperature Controller |
| Temperature Range | Up to 260 °C |
| Temp. Accuracy | ±0.2 °C |
| Programmable Steps | 30 |
| Sample Capacity | 8 × 100 mL Vessels |
| Pressure Rating (Digestion Vessels) | 10 MPa |
| Dimensions (W×D×H) | 670 × 460 × 270 mm |
| Input Voltage | AC 220 V / 50 Hz, 16 A |
| Compliance | Meets GB/T 150 (China National Standard for Pressure Vessels) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | Graphite Digestion Assistant |
| Instrument Type | Graphite Digestion Accessory |
| Sample Vessel Compatibility | Universal (Customizable for Domestic & Imported Graphite Block Digesters) |
| Material | High-Purity Isostatically Pressed Fine-Grain Graphite with DuPont™ Teflon® Coating |
| Surface Treatment | High-Pressure Air Atomization Spray Process |
| Thermal Stability | Up to 330 °C |
| Corrosion Resistance | Certified for prolonged exposure to concentrated HNO₃, HCl, HF, H₂SO₄, and aqua regia |
| Included Accessories | Portable Carrying Case with Phenolic Foam Liner, Non-Contact Infrared Thermometer (–50 °C to 330 °C), Telescopic Acid-Resistant Inspection Mirror (16–52 cm extension, 360° axial/radial rotation), Stainless Steel Non-Magnetic Sample Handling Tools |
| Standard Configuration | 15 Custom-Fit Conversion Components per Set |
| Customization | Available for non-standard vessel geometries and OEM integration |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HW Series |
| Instrument Type | Graphite-Based Infrared Digestion System |
| Heating Material | High-Temperature PTFE-Coated Graphite |
| Max Power | 2500 W (HW-15), 3500 W (HW-24/HW-40/HW-54) |
| Control Method | PID Digital Display |
| Temperature Program Steps | 30 |
| Max Operating Temperature | 460 °C |
| Temperature Accuracy | ±1.0 °C |
| Sample Capacity | HW-15: 15 × 100 mL |
| HW-24 | 24 × 50 mL |
| HW-40 | 40 × 100 mL |
| HW-54 | 54 × 50 mL |
| Digestion Well Dimensions | HW-15: Φ42 × 40 mm |
| HW-24 | Φ26 × 40 mm |
| HW-40 | Φ42 × 40 mm |
| HW-54 | Φ23 × 50 mm |
| Power Supply | AC 220 V / 50 Hz, 16 A |
| Unit Dimensions (W×D×H) | HW-15: 470 × 350 × 270 mm |
| HW-24/HW-40/HW-54 | 670 × 460 × 270 mm |
| Compatible Vessels | Standard borosilicate glass digestion tubes (custom diameters supported) |
| Brand | MICHEM |
|---|---|
| Model | HW-15 / HW-24 / HW-40 / HW-54 |
| Type | Infrared-Heated Graphite Block Digestion System |
| Maximum Temperature | 460 °C |
| Temperature Control Accuracy | ±1.0 °C |
| Heating Principle | Far-Infrared Radiant Heating |
| Heating Material | High-Temperature PTFE-Coated Graphite Block |
| Power Rating | 2500 W (HW-15/HW-40) / 3500 W (HW-24/HW-54) |
| Control System | PID Digital Controller with 30-Step Programmable Ramp-Soak Profile |
| Sample Capacity | 15 × 100 mL |
| Digestion Well Dimensions | Φ42 mm × 40 mm (HW-15/HW-40), Φ26 mm × 40 mm (HW-24), Φ23 mm × 50 mm (HW-54) |
| Power Supply | AC 220 V, 50 Hz, 16 A |
| Dimensions (W×D×H) | 470×350×270 mm (HW-15), 670×460×270 mm (HW-24/HW-54) |
| Customization Available | Well diameter/depth, batch size, nominal operating temperature, and power rating per unit |
| Brand | MICHEM |
|---|---|
| Model | HW-Touch |
| Heating Method | Infrared |
| Heating Material | High-Purity Graphite with PTFE Coating |
| Effective Heating Area | 470 × 314 mm |
| Temperature Range | RT–460 °C |
| Temperature Control Accuracy | ±0.1 °C |
| PID Programmable Control | 30-Step Ramp/Soak |
| Max Power | 3500 W |
| Overheat Protection | Yes |
| Dimensions (W×D×H) | 770 × 520 × 200 mm |
| Power Supply | AC 220 V / 50 Hz / 10 A |
| Standard Accessories | 30 sets high-borosilicate glass digestion vessels (with reflux condensers), 1 digestion rack, 30 sets PTFE digestion cups |
| Brand | MICHEM |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hyscan II |
| Pricing | Upon Request |
| Dimensions (W×D×H) | 600 × 600 × 1000 mm |
| Weight | 120 kg |
| Power Supply | 220 V / 50 Hz, 5 m armored cable |
| Sample Mass | 100 g |
| Measurement Time | < 5 min |
| Measurement Range | 0.01–1.99 cm³/100 g |
| Sensitivity | 0.01 cm³/100 g |
| Accuracy | ±5% (vs. vacuum fusion reference method) |
| Compliance | LMFA Certified |
| Brand | MICHEM |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Hyscan II |
| Price Range | USD 68,000–95,000 |
| Dimensions (W×D×H) | 600 mm × 600 mm × 1000 mm |
| Weight | 120 kg |
| Power Supply | 220 V AC, 50 Hz, armored 5-m power cable |
| Sample Mass | 100 g |
| Measurement Time | < 5 minutes |
| Detection Range | 0.01–1.99 cm³/100 g |
| Sensitivity | 0.01 cm³/100 g |
| Accuracy | ±5% (vs. vacuum fusion reference method) |
| Certification | LMFA (Light Metals Federation of America) Manufacturing License |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-10000C |
| Instrument Type | Split-System |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 10,000 W |
| Circulating Pump Pressure | 7 bar |
| Circulating Pump Flow Rate | 6 L/min |
| Reservoir Volume | 100 L |
| Operating Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-1000BP |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 1000 W |
| Circulating Pump Pressure | 7 bar |
| Flow Rate | 6 L/min |
| Reservoir Volume | 10 L |
| Operating Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-1000C |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5–35 °C |
| Cooling Capacity | 1000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 5 L/min |
| Reservoir Volume | 7 L |
| Operating Mode | Continuous |
| Compressor Type | Inverter-Driven |
| Control Algorithm | PID |
| Input Power | 500 W |
| Power Supply | 220 V, 10 A |
| Dimensions (W×D×H) | 520×420×680 mm |
| Brand | MICHEM |
|---|---|
| Model | MC-1000C |
| Type | On/Off-Controlled Recirculating Chiller |
| Cooling Capacity | 1000 W |
| Temperature Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Control Mode | PID with Auto-Tuning |
| Reservoir Volume | 7 L |
| Pump Flow Rate | 5 L/min |
| Max. Outlet Pressure | 5 bar |
| Power Input | 220 V, 10 A, 280 W |
| Dimensions (W×D×H) | 440 × 600 × 710 mm |
| Refrigeration Technology | Plate Heat Exchanger with Overcooling Protection |
| Temperature Sensor | Pt100 Platinum RTD with Line-Break & Voltage Fluctuation Compensation |
| Safety Features | Overvoltage Protection, Low-Temperature Cut-off (<3 °C), AL Alarm at <5 °C |
| Pump Type | Diaphragm Pump |
| Noise Level | Low-Noise Operation |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-1600BP |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Cooling Capacity | 1600 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 6 L/min |
| Reservoir Volume | 10 L |
| Operating Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-2500BP |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 2500 W |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 6 L/min |
| Reservoir Volume | 10 L |
| Operating Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-3500BP |
| Type | Split-System Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 3500 W |
| Circulating Pump Pressure | 7 bar |
| Flow Rate | 6 L/min |
| Reservoir Volume | 20 L |
| Operation Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-600C |
| Instrument Type | Integrated |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Cooling Capacity | 600 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 5 L/min |
| Reservoir Volume | 7 L |
| Operation Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-7000C |
| Instrument Type | Split-System Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Cooling Capacity | 7000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 6 L/min |
| Reservoir Volume | 80 L |
| Operation Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Model | MD Series |
| Origin | Beijing, China |
| Microwave Frequency | 2450 ±13 MHz |
| Output Power | 1200 W |
| Power Control | 0–100% PID Automatic Continuous Adjustment |
| Cavity Volume | 45 L |
| Dimensions (W×D×H) | 490 × 610 × 610 mm |
| Net Weight | 48 kg |
| Temperature Range | 0–300 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range | 0–6 MPa |
| Pressure Accuracy | ±0.05 MPa |
| Microwave Leakage | ≤0.3 mW/cm² |
| Cavity Coating | Dupont PFA |
| Outer Vessel Material | PEEK (10 MPa burst rating) |
| Inner Vessel Material | TFM (chemically resistant, up to 300 °C) |
| Cooling Airflow | 3 m³/min (cooling to safe opening temperature within 20 min) |
| Door Mechanism | Patented lateral-release safety door with dual-stage explosion protection (Patent No.: ZL 200420032536) |
| Stirring | 360° reversible turntable |
| Reaction Vessel Capacity | 10–1500 mL (standard 500 mL) |
| Control Options | A-type (laptop-based software with real-time T/P curve monitoring, unlimited method storage) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6 |
| Sample Capacity | 6–10 vessels |
| Microwave Source | Dual-Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 2200 psi |
| Cavity Lining | PFA-coated (DuPont™) |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–6 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Microwave Leakage | ≤0.3 mW/cm² |
| Output Power | 1200 W (0–100% PID-adjustable) |
| Cavity Volume | 45 L |
| Dimensions (W×D×H) | 490×610×610 mm |
| Weight | 48 kg |
| Cooling Airflow | 3 m³/min |
| Safety | Six-layer protection including dual-stage pressure relief, auto-locking blast-resistant door (Patent ZL 200420032536), rupture disc, and real-time Pt100/pressure dual-sensor feedback |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6 |
| Chamber Classification | Industrial-Grade |
| Sample Capacity | 10 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 1500 psi |
| Cavity Lining | PFA-coated (DuPont™) |
| External Cooling Airflow | 3 m³/min |
| Microwave Leakage | ≤0.3 mW/cm² |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–10 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Vessel Material | Outer — PEEK (10 MPa rating) |
| Safety Features | Dual-stage pressure relief membrane, patented lateral-sliding safety door (ZL 200420032536), real-time dual-parameter (T&P) monitoring, interlocked door sensor, Pt100 direct-contact temperature sensing, overpressure/overtemperature cut-off |
| Brand | MICHEM |
|---|---|
| Model | MD6 |
| Origin | Beijing, China |
| Microwave Frequency | 2450 ± 13 MHz |
| Output Power | 1200 W |
| Power Control | 0–100% PID automatic continuous adjustment |
| Cavity Volume | 45 L |
| Dimensions (W×D×H) | 490 × 610 × 610 mm |
| Net Weight | 48 kg |
| Temperature Range | 0–300 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range | 0–6 MPa (900 psi) |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Coating | PFA (DuPont™) |
| Microwave Leakage | ≤0.3 mW/cm² |
| Safety Features | Dual-stage explosion-proof door (Patent ZL 200420032536), rupture disk pressure relief, Pt100 direct-contact temperature sensing, real-time dual-parameter (T&P) monitoring |
| Vessel Configuration | PEEK outer vessel (10 MPa rating), TFM inner vessel (chemically inert, 300 °C stable) |
| Rotation | 360° reversible turntable with magnetic & mechanical stirring (0–5000 rpm) |
| Sample Capacity | Up to 10 vessels per run (standard: 4 or 6 vessels |
| volume range | 10–1500 mL) |
| Control Options | A-type laptop-based software interface (unlimited method storage, real-time T&P curve logging) or C-type microcontroller (15 pre-programmed methods, 8-step ramping) |
| Ventilation | 3 m³/min forced-air cooling, <20 min cooldown to safe opening temperature |