Ocean Optics
Filter
Showing 1–30 of 129 results
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HRS-5A |
| Pricing | Available Upon Request |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ISS-2 |
| Light Source Type | Tungsten-Halogen Lamp |
| Illumination Geometry | Internal (In-Cuvette) |
| Optical Path Length | 1 cm |
| Collimating Lens | 5 mm Ø, f/2, BK7 glass, f = 10 mm, SMA 905 connector |
| Filter Holder | Accepts filters up to 6.35 mm (1/4") thick |
| Base Material | Aluminum |
| Spectral Range | 360 nm – 2000 nm |
| Dimensions (L×W×H) | 155.0 × 50.0 × 53.3 mm |
| Input Power | 12 VDC / 800 mA (operating range: 7–20 VDC / 0.5–2 A) |
| Lamp Power | 5 V / 1.3 A |
| Output Power | 6.5 W |
| Lamp Lifetime | 900 h |
| Warm-up Time to Stability | ~30 min |
| Voltage Regulation Accuracy | ±0.2% |
| Cooling | Integrated axial fan beneath lamp assembly |
| Positioning Mechanism | Spring-loaded spherical screw for precise 1 cm cuvette alignment |
| Brand | Ocean Optics |
|---|---|
| Model | FD-LTMS |
| Wavelength Range | 400–700 nm |
| Detector | 1024-element linear array |
| Optical Design | Asymmetric crossed Czerny-Turner spectrometer |
| Spectral Sampling Interval | 10 nm |
| FWHM | 6 nm |
| Light Source | Pulsed LED (>250 million measurements lifetime) |
| Sample Holders | 10 mm pathlength cuvette & flow-cell interface |
| Connectivity | USB 2.0 |
| OS Compatibility | Windows 7+, 64-bit |
| Enclosure Rating | IP67 |
| Origin | Shanghai, China |
| Manufacturer | Ocean Optics (Shanghai) |
| Brand | Ocean Optics |
|---|---|
| Model | newopto |
| Material | Fused Silica (Dynasil) / BK7 / BaF10+FD10 |
| Spectral Range | 200–2000 nm |
| Beam Divergence | ≤2° |
| Focal Length Options | 10 mm, 30 mm, 100 mm |
| Diameter Options | 5 mm, 25.4 mm, 30 mm |
| f-number | f/2 |
| Operating Temperature | Up to 200°C |
| Connector | SMA905 with 6.35 mm ferrule and 3/8-24 external thread (variant-specific) |
| Compliance | RoHS-compliant optical assembly |
| Mounting Interface | Standardized 3/8-24 or 1/4-36 external/internal threads |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | 74-Series |
| Component Type | Fiber Collimator |
| Lens Materials | Fused Silica (74-UV, 74-DA), BK-7 Glass (74-VIS), BaF10/FD10 Achromatic Doublet (74-ACR) |
| Wavelength Ranges | 200–2000 nm (74-UV, 74-DA), 350–2000 nm (74-VIS, 74-ACR) |
| Diameter | 5 mm |
| Focal Length | 10 mm (f/2) |
| Operating Temperature | Up to 150 °C |
| Connector | SMA 905 with 6.35-mm ferrule and 3/8-24 external thread (74-UV/VIS/ACR) |
| Beam Divergence | ≤2° (74-UV) |
| Housing | Black-oxidized stainless steel |
| Focus Adjustment | Manual, continuous from convergent to divergent (~45° total field-of-view range) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCULIBS 2500 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Wavelength | 1064 nm |
| Translation Stage Range | 50 × 50 × 20 mm |
| Positioning Accuracy | ≥1 μm |
| Wavelength Coverage | 180–1037 nm (configurable) |
| Optical Resolution | 0.1 nm (FWHM) |
| Minimum Integration Time | 1 ms |
| Trigger Jitter | ±10 ns |
| Trigger Delay Range | ±450 μs |
| Spectral Channels | 1–8 |
| Gas Control | Solenoid-Valve Actuated Enclosure |
| Imaging | Optional 2× or 5× magnification, fixed-focus optical path |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable options) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window selection) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Optical NA | 0.22 |
| Working Distance | 7.5 mm |
| Display | 4.5″ capacitive multi-touch LCD (720p) |
| Data Interfaces | USB 2.0, Wi-Fi |
| Data Formats | .pdf, .csv, .txt, .jdx, .rdb |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (main unit) |
| Operating Temperature | 0–45 °C |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Numerical Aperture | 0.22 |
| Working Distance | 7.5 mm |
| Display | 4.5″ LCD, 720p capacitive multi-touch |
| Data Interfaces | USB 2.0, Wi-Fi |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (unit) |
| Operating Temperature | 0–45 °C |
| Data Formats | .pdf, .csv, .txt, .jdx, .rdb |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 170–3900 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Detector | Deep-Cooled Back-Illuminated CCD |
| Excitation Wavelength | 785 nm (standard), optional 532 nm or 1064 nm configurations |
| Laser Stability | <±0.02 nm over 8 hours |
| Spectral Reproducibility | <±0.5 cm⁻¹ (RMS, 24 h) |
| Data Interface | USB 3.0 and Wi-Fi 5 (802.11ac) |
| Operating Temperature | 10–40 °C |
| Weight | 1.4 kg (with battery) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Display | 4.5″ 720p capacitive multi-touch LCD |
| Data Interfaces | USB 2.0, Wi-Fi |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (unit) |
| Operating Temperature | 0–45 °C |
| Software Features | Fluorescence background subtraction, spectral similarity matching, quantitative modeling, PDF/CSV/TXT/JDX/RDB export |
| Compliance | ASTM E1840, ISO 8573-1 (for optical path integrity), GLP/GMP-ready audit trail in software log |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HG-2 Calibration Light Source |
| Light Source Type | Low-Pressure Mercury Vapor Lamp |
| Illumination Mode | Internal Illumination Configuration |
| Dimensions | 12.6 × 7.0 × 2.6 cm |
| Weight | 180 g |
| Power Consumption | ≤2 A at 5 VDC (external supply or embedded Li-ion battery charging mode) |
| Battery | Rechargeable, integrated lithium-ion |
| Lamp Lifetime | 3,500 hours (typical) |
| Aperture Diameter | 3 mm |
| Amplitude Stability | <±0.5% over 60 s (after thermal stabilization) |
| Fiber Connector | SMA 905 |
| Spectral Range | 170–1700 nm (HG-2 variant) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DH-2000 |
| Light Source Type | Deuterium + Tungsten-Halogen Hybrid |
| Illumination Mode | External Illumination |
| Spectral Range | 190–1700 nm (UV-enhanced option), 215–2000 nm (standard) |
| Dimensions | 150 mm × 135 mm × 319 mm |
| Weight | 3.5 kg |
| Power Consumption | 25 W (deuterium lamp), 20 W (tungsten-halogen lamp), ~78 VA total |
| Warm-up Time | 40 min (D₂), 20 min (W-Hal) |
| Lamp Lifetime | 1,000 hours |
| Operating Temperature | 5–35 °C |
| Humidity | 5–95% RH at 40 °C (non-condensing) |
| Voltage Stability | <5 × 10⁻⁶ peak-to-peak (0.1–10.0 Hz) |
| Drift | <0.01% per hour |
| Safety Certifications | CE, VDI/VDE 0160, EN 61010 |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | DH-2000 |
| Light Source Type | Deuterium + Tungsten Halogen |
| Spectral Range | 215–2500 nm (DH-2000-DUV: 190–2500 nm) |
| Output Stability | <5 × 10⁻⁶ peak-to-peak (0.1–10.0 Hz) |
| Drift | <0.01% per hour |
| Warm-up Time | 25 min |
| Lamp Life | 1000 h |
| Power Consumption | ~78 VA |
| Dimensions (W×H×L) | 15 × 13.5 × 28.5 cm |
| Weight | 5 kg |
| Compliance | CE, RoHS, WEEE |
| Operating Temperature | 5–35 °C |
| Operating Humidity | 5–95% RH (non-condensing at 40 °C) |
| Brand | Ocean Optics |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DH-2000-BAL |
| Light Source Type | Deuterium + Tungsten-Halogen Hybrid |
| Illumination Mode | External Illumination |
| Wavelength Range | 215–2000 nm |
| Deuterium Lamp Range | 215–400 nm |
| Tungsten-Halogen Lamp Range | 360–2000 nm |
| Power Consumption | 25 W (D₂), 20 W (W-Hal), Max. 190 W |
| Warm-up Time | 40 min (D₂), 20 min (W-Hal) |
| Dimensions | 150 × 135 × 319 mm |
| Weight | 3.8 kg |
| Operating Temperature | 5–35 °C |
| Humidity | 5–95% RH (non-condensing at 40 °C) |
| Stability | <0.01% per hour (intensity drift), <5 × 10⁻⁶ peak-to-peak (0.1–10 Hz) |
| Certifications | CE, VDI/VDE 0160, EN 61010 |
| Brand | Ocean Optics |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DH-2000-CAL |
| Light Source Type | Xenon-based (Deuterium + Tungsten-Halogen) |
| Illumination Mode | External Illumination |
| Calibration Wavelength Range | 220–1050 nm |
| Calibration Uncertainty | ±5% |
| Calibration Validity | 50 hours of operation |
| Power Consumption | 25 W (D₂), 20 W (W-Halogen), max. 190 W total |
| Warm-up Time | 40 min (D₂), 20 min (W-Halogen) |
| Dimensions | 150 × 135 × 319 mm |
| Weight | 6 kg |
| Input Voltage | 85–264 V AC, 50/60 Hz |
| Voltage Stability | <5 × 10⁻⁶ peak-to-peak (0.1–10.0 Hz) |
| Humidity | 5–95% RH (non-condensing at 40 °C) |
| Operating Temperature | 5–35 °C |
| Certifications | CE, VDI/VDE 0160, EN 61010 |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | DT-MINI-2 / DT-MINI-2-GS |
| Wavelength Range | 200–410 nm (deuterium), 360–2000 nm (tungsten halogen) |
| Output Aperture | 0.5 mm |
| Power Consumption | 350 mA @ 12 VDC |
| Deuterium Output | 3.8 W |
| Tungsten Halogen Output | 1.2 W |
| Intensity Stability | ±0.3% peak-to-peak after 30 min warm-up (over 4 h) |
| Warm-up Time | 10 min (deuterium), 1 min (tungsten halogen) |
| Lamp Lifetime | ~1500 h (both lamps) |
| Shutter Option | TTL- and manual-triggered mechanical shutter (DT-MINI-2-GS only) |
| Connector | SMA 905 |
| Dimensions (DT-MINI-2) | 153.4 × 104.9 × 40.9 mm |
| Dimensions (DT-MINI-2-GS) | 140 × 50 × 125 mm |
| Weight (DT-MINI-2) | 330 g |
| Weight (DT-MINI-2-GS) | 475 g |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FD-1665 |
| Effective Pixels | 1628 × 1236 |
| Pixel Size | 4.4 µm (standard CCD) |
| Spectral Range | 400–1100 nm |
| Frame Rate | up to 71 fps |
| Bit Depth | 12-bit ADC |
| Interface | Triple Gigabit Ethernet (CAT 5e/6) |
| Lens Mount | Nikon F-mount |
| Operating Temperature | 0–40 °C |
| Power Consumption | 10 W |
| Sensor Configuration | Trichroic beam-splitting architecture with three parallel CCD planes |
| Output Formats | Y8, Y16, RGB, YUV411/422/444, raw 8-/16-bit Bayer |
| Shutter Modes | Auto, manual, one-shot programmable |
| GPIO | 12-pin Hirose connector |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Spectrophotometer |
| Instrument Type | In-Line |
| Optical Geometry | d/8° (Diffuse Illumination / 8° Viewing) |
| Light Source | Pulsed LED |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | 0.01 ΔE*ab |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FD-D8R |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Type | In-Line |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed LED |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | 0.01 ΔE*ab |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Ocean Optics SR2 |
| Spectral Range | 185–1100 nm (configuration-dependent) |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.56–1.71 nm |
| Signal-to-Noise Ratio (SNR) | 380:1 (single acquisition) |
| Dynamic Range | 3400:1 (single acquisition) |
| Integration Time | as low as 10 µs |
| Stray Light | Not specified |
| Slit Options | 5–200 µm |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Principle | Fiber-coupled, non-cooled InGaAs-based dispersive spectroscopy |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Scan Rate | 400 spectra/sec |
| Integration Time | 1 ms – 65 s |
| Sampling Interval | 1 ms – 65 s |
| Measurement Mode | Transmission |
| Detector | Uncooled 128-pixel InGaAs linear array (900–1700 nm response) |
| SNR | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, OceanInsight NIR Chemometrics Suite |
| Compliance | CE, RoHS, FCC Class B |
| Modularity | Interchangeable slits, fiber-optic coupling, OEM-ready architecture |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Principle | Fiber-coupled, non-cooled InGaAs detection |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Scan Rate | 400 spectra/sec |
| Integration Time | 1 ms – 65 s |
| Sampling Interval | 1 ms → 65 s |
| Measurement Mode | Transmission |
| Detector | Uncooled 128-pixel InGaAs array (900–1700 nm response) |
| SNR | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, OmniDriver, NIR chemometrics suite |
| Slit Options | User-replaceable for resolution/sensitivity tuning |
| LED Indicators | Power & acquisition status |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Integration Time | 1 ms – 65 s |
| Scan Rate | 400 spectra/s |
| Detector | Uncooled InGaAs linear array (128 pixels, 900–1700 nm response) |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, NIR Tools, and third-party chemometrics platforms (e.g., MATLAB, Python with Ocean SDK) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Portable Spectrometer |
| Principle | Grating-based Scanning Spectroscopy |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Maximum Scan Rate | ~400 Hz |
| Integration Time | 1 ms – 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Portable NIR Spectrometer |
| Principle | Grating-based Scanning Spectrometer |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Scan Rate | ~400 Hz |
| Integration Time | 1 ms to 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Origin | Shanghai, China |
| Manufacturer | Ocean Optics (Shanghai) |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Handheld NIR Spectrometer |
| Optical Principle | Grating-based Scanning |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Scan Rate | ~400 Hz |
| Integration Time | 1 ms – 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8,000:1 |
| Stray Light | <0.05% at 600 nm |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector | CCD array |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8000:1 |
| Stray Light | <0.05% at 600 nm |
| Display | Monochrome e-ink screen |
| Battery | Removable 4200 mAh Li-ion, >6 h continuous operation |
| Interface | Android-based acquisition app + Windows-compatible spectral processing software |
| Data Export Formats | .txt, .csv, .m |
| Mounting | Adjustable tripod-compatible handle (29–88 cm height range) |
| Integrated features | Motorized shutter, auto-exposure, embedded image/audio annotation |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector | CCD |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8000:1 |
| Stray Light | <0.05% at 600 nm |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8000:1 |
| Stray Light | <0.05% at 600 nm |
| Operating System Compatibility | Android & Windows |
| Display | Low-Power Monochrome E-Ink Screen |
| Power Efficiency | Optimized for extended field deployment |