Ruixin
Filter
Showing 91–120 of 144 results
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-GY2 |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Type | Edible Oil Samples Only |
| Wavelength | 540 nm |
| Assay Time | ≤ 3 min per sample |
| Photometric Repeatability | ≤ 0.5% |
| Absorbance Range | 0–2.500 A |
| Detection Limit | 0.3 mmol/kg |
| Measurement Range | 0–11 mmol/kg |
| Photocurrent Drift | ≤ 0.002 A (within 3 min) |
| Data Interface | RS-232 |
| Power Supply | 9 V DC battery / 9 V DC adapter / 220 V AC input |
| Dimensions | 175 × 100 × 85 mm |
| Net Weight | < 0.8 kg |
| Detection Channel | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SPb-HF2 |
| Price | ¥7,800 |
| Functionality | Single-Analyte Detection |
| Sample Format | Single-Sample Dedicated |
| Wavelength | 540 nm |
| Assay Time | ≤3 min |
| Repeatability | ≤0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-I2 |
| Function Type | Single-Parameter Detection System |
| Sample Type | Dedicated to Edible Salt Samples |
| Wavelength Range | 400–680 nm |
| Detection Time | <2 min per sample |
| Repeatability (RSD) | <5% |
| Detection Channels | 1 |
| Absorbance Display Range | 0.000–4.000 |
| Transmittance Display Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Baseline Stability (3 min) | ≤0.3% |
| Limit of Detection (LOD) | 0.1 mg/kg |
| Quantification Range | 0–10 mg/kg |
| Communication Interfaces | RS232, USB |
| Power Options | Integrated Li-ion battery, AC 220 V, DC 5 V |
| Built-in Thermal Printer | Yes |
| Touchscreen | 4.3-inch HD color LCD with Chinese UI |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SPb-JAS2 |
| Price Range | USD 2,800 – 4,200 |
| Function Type | Single-Analyte Detection System |
| Sample Format | Single-Sample Dedicated Platform |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 minutes |
| Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JC2 |
| Price | USD 790 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Format | Single-Sample Dedicated |
| Wavelength | 540 nm |
| Assay Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-JCd2 |
| Price Range | USD 4,200 – 7,000 |
| Functionality | Single-Analyte Detection (Cadmium Only) |
| Sample Format | Single-Sample Dedicated System |
| Optical Wavelength | 540 nm |
| Detection Time | ≤ 3 min |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JHg2 |
| Price Range | USD 4,200 – 7,000 |
| Functionality | Single-Analyte Detection (Mercury Only) |
| Sample Format | Single-Sample Dedicated Use |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 min |
| Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JPb2 |
| Functionality | Single-Analyte Detection (Lead Only) |
| Sample Format | Single-Sample Dedicated Use |
| Wavelength | 540 nm |
| Detection Time | ≤3 min |
| Repeatability | ≤0.2% |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Stability (3 min) | ≤0.3% |
| LOD for Pb | 0.5 mg/kg |
| Quantification Range for Pb | 0–15 mg/kg |
| Communication Interfaces | RS-232, USB |
| Power Supply | Integrated Li-ion Battery, AC 220 V, DC 5 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JQ2 |
| Price | USD 1,380 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Single-Sample Dedicated System |
| Optical Wavelength | 410 nm |
| Detection Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JS2 |
| Function Type | Single-Analyte Dedicated Analyzer |
| Sample Type | Rapeseed Only |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min |
| Repeatability | ≤0.2% |
| Optical Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Stability (3 min) | ≤0.3% |
| Limit of Detection (Erucic Acid) | 0.5% (w/w) |
| Interface | USB |
| Power Supply | AC 220 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-LG2 |
| Function Type | Single-Analyte Dedicated Analyzer |
| Sample Type | Rapeseed Only |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per sample |
| Repeatability (RSD) | ≤0.2% |
| Optical Channels | 1 |
| Absorbance Display Range | 0.000–4.000 |
| Transmittance Display Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Baseline Stability (3 min) | ≤0.3% |
| Limit of Detection (LOD) | 10 µmol/g |
| Interface | USB |
| Power Supply | 220 V AC |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-LL2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Dedicated Single-Sample Cartridge/Well |
| Optical Wavelength | 630 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% CV |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-LS2 |
| Price | USD 920 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Format | Dedicated Single-Sample Cartridge |
| Wavelength | 630 nm |
| Assay Time | ≤ 180 s |
| Optical Repeatability (Transmittance) | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-PS2 |
| Price Range | USD 2,800 – 4,200 (FOB Shanghai) |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Type | Single-Sample Format |
| Optical Wavelength | 540 nm |
| Detection Time | ≤ 3 minutes |
| Photometric Repeatability | ≤ 0.2% (Transmittance) |
| Measurement Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-SL2 |
| Price | USD 780 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated Analyzer |
| Sample Format | Single-sample discrete mode |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% (at 540 nm) |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-SY2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Type | Dedicated Single-Sample Format |
| Wavelength | 410 nm |
| Detection Time | ≤ 180 seconds |
| Repeatability | ≤ 0.2% (RSD) |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-TJ2 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Functionality | Single-Analyte Detection System |
| Sample Format | Dedicated Single-Sample Cartridge |
| Optical Wavelength | 630 nm |
| Assay Time | ≤ 180 seconds per sample |
| Photometric Repeatability | ≤ 0.2% RSD |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-TM2 |
| Price | USD 780 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated System |
| Sample Format | Single-Sample Cartridge-Based |
| Wavelength | 410 nm |
| Assay Time | ≤ 3 min |
| Photometric Repeatability | ≤ 0.2% (at 410 nm) |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-XC2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Dedicated Single-Sample Cartridge/Tube |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (CV) |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 AU |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 AU |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Baseline Drift (3 min) | ≤0.3% |
| Amaranth LOD | 5.0 mg/kg |
| Amaranth Linear Range | 0–200 mg/kg |
| Communication Interfaces | RS-232, USB 2.0 |
| Power Options | Integrated Li-ion Battery (≥6 h operation), AC 220 V ±10%, DC 5 V input |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-XH2 |
| Price | USD 1,380 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Format | Dedicated Single-Sample Cartridge |
| Wavelength | 540 nm |
| Assay Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% RSD |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-XS2 Nitrate |
| Function Type | Single-Analyte Detection System |
| Sample Format | Single-Sample Dedicated Platform |
| Optical Wavelength | 410 nm |
| Assay Time | ≤ 3 min |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 AU |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 AU |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Baseline Stability (3 min) | ≤ 0.3% |
| Nitrate LOD | 100.0 mg/kg |
| Nitrate Measurement Range | 0–3000 mg/kg |
| Communication Interfaces | RS-232, USB |
| Power Supply Options | Integrated Li-ion Battery, AC 220 V, DC 5 V |
| Display | 4.3-inch High-Resolution Color TFT Touchscreen with Full Chinese UI |
| Onboard Thermal Printer | Embedded Micro-Thermal Printer for Channel-Specific Reports |
| Data Management | Auto-Save, Local Query, Real-Time Upload via Serial/USB |
| Calibration | Automated Optical Path Self-Alignment at Startup |
| Dual-Mode Output | Simultaneous Absorbance & Transmittance Readouts |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-XS2 |
| Price | USD 920 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Format | Single-Sample Dedicated Use |
| Optical Wavelength | 630 nm |
| Assay Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SPb-YS2 |
| Price | USD 1,380 (FOB Shanghai) |
| Function Type | Single-Analyte Detection |
| Sample Type | Single-Sample Dedicated |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 min |
| Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Stability (3-min drift) | ≤0.3% |
| LOD (Nitrite) | 2.0 mg/kg |
| Measurement Range (Nitrite) | 0–200 mg/kg |
| Communication Interfaces | RS232, USB |
| Power Supply | Integrated Li-ion Battery, AC 220 V, DC 5 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-YZ2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Detection System |
| Sample Format | Dedicated Single-Sample Cartridge |
| Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds per test |
| Photometric Repeatability | ≤ 0.2% RSD |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-ZA2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Dedicated Single-Sample Cuvette-Based Assay |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% CV |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 AU |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 AU |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Baseline Stability (3 min) | ≤0.3% |
| Histamine LOD | 1.0 mg/100 g |
| Histamine Linear Range | 0–100 mg/100 g |
| Communication Interfaces | RS-232, USB 2.0 |
| Power Supply | Internal Rechargeable Li-ion Battery (7.4 V, 4400 mAh), AC 220 V ±10%, DC 5 V Input |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SPb-ZT2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Format | Dedicated Single-Sample Cuvette Format |
| Optical Wavelength | 410 nm |
| Assay Time | ≤ 180 s per sample |
| Photometric Repeatability | ≤ 0.2% RSD |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SZ-2 |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Single-parameter Analyzer |
| Sample Type | Single-sample dedicated platform |
| Detection Time | ≤3 minutes |
| Repeatability | ≤0.2% |
| Detection Channels | 1 |
| Display | 4.5-inch high-resolution color LCD touchscreen (Chinese UI) |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy | ±2.0% (transmittance) |
| Stability | ≤0.3% (over 3 min) |
| Communication Interfaces | RS232, USB |
| Power Supply | AC 220 V / DC 5 V / Rechargeable Li-ion battery |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SZ-8D |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Parameters | Ammonia-N, Total Phosphorus, Total Nitrogen, COD (Cr), Residual Chlorine, Total Chlorine, Dissolved Oxygen, Volatile Phenols, Chlorine Dioxide |
| Display | 4.3-inch Color TFT Touchscreen |
| Absorbance Range | 0.000–4.000 AU |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 AU |
| Photometric Accuracy | ±2.0% T |
| Photometric Repeatability | ≤0.2% T |
| Baseline Stability | ≤0.3% (3 min) |
| Communication Interface | USB |
| Power Supply | AC 220 V / DC 5 V / Rechargeable Lithium Battery |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SZ-AD2 |
| Price | USD 780 (FOB Shanghai) |
| Function Type | Single-Analyte Dedicated Analyzer |
| Sample Format | Single-Sample Mode |
| Wavelength Range | 380–630 nm |
| Analysis Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (at 540 nm, using standard ammonia-nitrogen reference solution) |
| Optical Channels | 1 |
| Brand | RuiXin |
|---|---|
| Origin | Shanghai, China |
| Model | SZ-CL |
| Instrument Type | Portable |
| Measurement Parameter | Residual Chlorine |
| Detection Range | 0.05–10.00 mg/L |
| Accuracy | ≤5% |
| Repeatability | ≤2% |
| Resolution | 0.01 mg/L |
| Limit of Detection (LOD) | 0.02 mg/L |
| Display | 4.3-inch color TFT touchscreen |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy | ±2.0% (transmittance) |
| Photometric Repeatability | ≤0.2% |
| Baseline Stability | ≤0.3% (over 3 min) |
| Communication Interface | USB |
| Power Supply | AC 220 V / DC 5 V / Rechargeable Li-ion battery |
| Integrated Thermal Printer | Yes |
| Data Storage & Recall | Yes |
| Data Export Capability | Yes |