Ruixin
Filter
Showing 61–90 of 144 results
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NCD-100A |
| Price | USD 10,800 (FOB Shanghai) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Broad-spectrum food & agricultural matrices |
| Wavelength Range | 410–630 nm (with fixed filters at 410, 450, 540, 630 nm |
| Assay Time | ≤180 seconds per 96-well plate |
| Photometric Repeatability | ±1.0% CV or ±0.007 Abs |
| Detection Channels | 96 / 48 / 24-well configurable microplate format |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | NCD-96DY |
| Detection Principle | Enzyme-Linked Immunosorbent Assay (ELISA) |
| Wavelength Range | 400–1100 nm |
| Optical Channels | 96-well microplate format |
| Photometric Accuracy | ±0.005A (repeatability, 0–2A) |
| Measurement Range | 0.000–4.000 Abs |
| Resolution | 0.001 Abs |
| Wavelength Accuracy | ±2.0 nm |
| Bandwidth | 8 ±1.0 nm |
| Inter-channel Variation | ≤0.02A |
| Stability | ≤0.005A/hour |
| Stray Light | ≥2.0A at 510 nm (50.0 g/L NaNO₂) |
| Read Time | ≤5 s per plate |
| Data Storage | ≥100,000 test records |
| Calibration Curves | Up to 126 stored protocols |
| Analysis Modes | Qualitative (positive/negative), quantitative (concentration, P/CO, cutoff), semi-quantitative |
| Curve Fitting Algorithms | 9 methods including linear, logit-log, 4PL, quadratic, exponential regression |
| Interface | RS-232, USB |
| Software Compliance | Supports FDA 21 CFR Part 11 audit trail (via PC-hosted Ruixin ELISA Manager v3.x), GLP/GMP data integrity features |
| Regulatory Alignment | Compatible with ISO 15197, CLSI EP12-A2, and veterinary diagnostic validation frameworks per OIE Terrestrial Manual |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | NCD-96S |
| Function Type | Multi-analyte Quantitative & Qualitative Detection |
| Sample Compatibility | Universal for Animal-Derived Food Matrices |
| Wavelength Range | 400–1100 nm |
| Detection Time | ≤3 min per 96-well plate |
| Photometric Repeatability | ±0.005 A (0–2 A) |
| Detection Channels | 96-well microplate format |
| Optical System | Auto-calibrating 8-channel photometric system with standard filters at 405/450/492/630 nm (expandable to 10 filters) |
| Light Source | Quartz halogen lamp with auto-dimming idle mode |
| Absorbance Range | 0.000–4.000 A |
| Resolution | 0.001 A |
| Accuracy | ±1% (0–2 A) |
| Linearity Error | ±0.1% (0–2 A) |
| Inter-channel Variation | ≤0.02 A |
| Stability | ≤0.005 A/h |
| Stray Light | ≥2.0 A at 510 nm using 50.0 g/L sodium nitrite solution |
| Plate Read Time | 5 s |
| Data Storage | ≥100,000 test records |
| Analysis Methods | 9 algorithmic models including linear regression, semi-log, log-log, ratio-based, exponential, and quadratic curve fitting |
| Compliance Support | Configurable audit trail, user access levels, and data export compliant with GLP documentation workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RFE-3 |
| Price Range | USD 4,200 – 7,000 |
| Detection Range | 0–9999 RLU |
| LOD | 1×10⁻¹⁶ mol ATP |
| Detection Time | 10 s |
| Repeatability | CV ≤ 8% |
| Detection Channels | 1 |
| Display | LCD |
| Detection Principle | Bioluminescent reaction between ATP and luciferin-luciferase complex |
| Communication Interface | RS232 (Wi-Fi optional per firmware upgrade) |
| Power Supply | Rechargeable Li-ion battery |
| Form Factor | Handheld |
| Net Weight | 400 g |
| Light Source | LED |
| Sample Volume | 1 mL per swab |
| Swab Tube Dimensions | Ø12 × 155 mm |
| Data Storage | 2000 records |
| Limit Sets | 100 user-defined thresholds |
| Operating Temperature | 0–60 °C |
| Relative Humidity | 15–95% RH |
| Battery Life | ≥200 h (AA alkaline, 2 pcs) or equivalent Li-ion cycle |
| Output Units | RLU and configurable CFU (via user-defined conversion factor) |
| Compliance | ISO 15161:2001 (Food & Beverage sector application of ISO 9001), aligned with ISO 22000 hygiene validation requirements |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | RSY-1 |
| Price Range | USD 1,400–2,800 |
| Function Type | Single-parameter Detection |
| Sample Type | Single-species Dedicated |
| Detection Time | ≤3 min per sample |
| Repeatability | ≤0.3% (70–80% w/w moisture range) |
| Measurement Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RXHGZ-V1.0 |
| Detection Method | Rapid Colorimetric Assay |
| Measurement Range | 0–100% (Relative Inhibition) |
| Number of Channels | Multi-channel |
| Measurement Error | ±10% |
| Limit of Detection (LOD) | 0.05 ppm |
| Printing Medium | Thermal Adhesive Label Paper |
| Connectivity | Bluetooth 4.2 |
| Paper Width | 25–80 mm |
| Printable Width | 72 mm |
| Max Roll Diameter | 50 mm |
| Print Speed | 70 mm/s (Receipt), 40 mm/s (Label) |
| Power Supply | Rechargeable Built-in Lithium-ion Battery |
| Brand | RuiXin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SJ-LH221 |
| Price | USD 37 (excl. tax & shipping) |
| Detection Range | 1–50 ppm |
| Limit of Detection (LOD) | 1 ppm |
| Assay Format | Colorimetric Lateral Flow Immunoassay |
| Test Capacity | 50 tests per kit |
| Intended Use | Qualitative/semi-quantitative detection of residual oxalic acid in rinse water or surface swabs from Chinese mitten crab (*Eriocheir sinensis*) processed with oxalic acid–containing washing powder |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-1001AC |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Function Type | Multi-analyte Quantitative Detection System |
| Sample Compatibility | Solid and Liquid Extracts from Tea, Leafy Produce, and Herbal Matrices |
| Wavelength Range | 410–630 nm |
| Detection Time per Sample | ≤ 180 s |
| Photometric Repeatability | ≤ 1.0% (Transmittance) |
| Optical Channels | 8 independent photometric channels |
| Absorbance Accuracy | ±2.0% T |
| Dark Current Drift | ≤0.5% over 3 min |
| Detection Limits | 5.0 mg/kg for all listed analytes |
| Linear Dynamic Range | 0–200 mg/kg (pyrethroids, organophosphates) |
| Brand | Ruixin |
|---|---|
| Model | SP-1001T |
| Origin | Shanghai, China |
| Wavelength Range | 400–680 nm |
| Detection Time | <2 min |
| Repeatability | <5% |
| Detection Channels | 8 |
| Photometric Accuracy | ±2.0% T |
| Photometric Repeatability | 1.0% T |
| Dark Current Drift | 0.5% (3 min) |
| Dimensions | 470 × 280 × 150 mm |
| Function Type | Single-analyte Quantitative Detection |
| Sample Compatibility | Multi-sample Universal Format |
| Interface | USB |
| Data Output | Built-in Thermal Printer + PC Software Integration |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-1218D |
| Function Type | Multi-parameter rapid detection (spectrophotometric + dry immunochromatographic gold nanoparticle assay) |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per sample |
| Repeatability | ≤0.3% (photometric), CV <1% (colloidal gold) |
| Detection Channels | 12 independent optical channels |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±0.5% T |
| Photocurrent Drift | ≤0.2% (3 min) |
| Overall Measurement Accuracy | ±5% (vs. reference standards) |
| Colloidal Gold Module | 3 dedicated readers with CT-ratio, colorimetric, and T/C line quantification |
| Connectivity | USB ×3, Wi-Fi, Bluetooth 4.2, 4G LTE |
| Power Supply | AC 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-2418D |
| Function Type | Multi-parameter rapid detection (expandable to 100+ assays) |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per assay |
| Photometric Repeatability | ≤0.2% T |
| Optical Channels | 24 independent photometric channels |
| Colloidal Gold Reader Modules | 3 standard (expandable to 10) |
| Display | 10.1″ capacitive touchscreen (Android OS) |
| Data Connectivity | RJ45 Ethernet, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, 4G LTE Cat.4 |
| Power Supply | AC 220 V ±10% |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±2.0% T |
| Photocurrent Drift | ≤0.2% (3 min) |
| Overall Measurement Accuracy | ±5% (relative to reference methods) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP-801B |
| Function Type | Multi-parameter (60+ configurable assays) |
| Sample Compatibility | Universal for liquid, extract, and homogenized food matrices |
| Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time per Channel | ≤ 180 s |
| Photometric Repeatability (Transmittance) | ≤ 0.2% |
| Absorbance Resolution | 0.001 AU |
| Transmittance Resolution | 0.01% |
| Optical Accuracy (Transmittance) | ±2.0% |
| Baseline Stability (3 min) | ≤0.2% |
| Detection Channels | 24 simultaneous cuvette-based optical paths |
| Display | 7.0-inch capacitive touch TFT-LCD (800×480) with full Chinese UI |
| Data Output | Embedded thermal printer, RS232, USB 2.0 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-801D |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per assay |
| Photometric Repeatability | ≤0.3% (T) |
| Optical Channels | 8 independent photometric channels + 1 integrated colloidal gold lateral flow reader |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Absorbance Resolution | 0.001 A |
| Transmittance Resolution | 0.01% T |
| Photometric Accuracy | ±2.0% (T) |
| Dark Current Drift | ≤0.3% over 3 min |
| Measurement Accuracy | ±5% (relative to reference standards) |
| Operating System | Android 9.0 or Windows 10 IoT Enterprise (pre-installed) |
| Storage | 32 GB eMMC (expandable to 64 GB) |
| RAM | 2 GB DDR4 |
| Connectivity | Dual-band Wi-Fi (802.11 a/b/g/n/ac), Bluetooth 5.0, optional 3G/4G LTE module |
| Power Supply | AC 220 V ±10% / Internal rechargeable Li-ion battery (5 h continuous operation) |
| Display | 10.6-inch capacitive multi-touch LCD (1920×1080) |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SP-801SC |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-analyte Rapid Detection System |
| Sample Format | Single-sample per test cycle |
| Wavelengths | 410 nm, 510 nm, 630 nm |
| Assay Time | ≤ 180 s per sample |
| Photometric Repeatability | ≤ 0.2% (Transmittance), ≤ 0.3% (Absorbance) |
| Detection Channels | 8 parallel optical paths |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-B |
| Price | USD 1,800 (approx.) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Fresh and Processed Meat Samples |
| Wavelength Range | 410–630 nm |
| Assay Time | ≤ 3 min per sample |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 8 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-CHN |
| Price | USD 780 (approx.) |
| Functionality | Single-analyte, dedicated assay |
| Sample Format | Homogenized tissue extract (liquid phase) |
| Wavelength Range | 400–680 nm |
| Assay Time | <120 s per sample |
| Coefficient of Variation (CV) | <5% |
| Detection Channels | 1 |
| Detection Limit | 10 mg/100 g in fish and aquatic animal tissues |
| Linear Range | 10–200 mg/100 g (typical for enzymatic/colorimetric histamine assays) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-FM2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-analyte Quantitative Detection |
| Sample Type | Dedicated to Honey Matrix Only |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds per sample |
| Photometric Repeatability | ≤ 0.2% CV |
| Detection Channels | 1 |
| Display | 4.3-inch Color TFT Touchscreen |
| Absorbance Range | 0.000–4.000 (Resolution: 0.001) |
| Transmittance Range | 0.00–100.00% (Resolution: 0.01%) |
| Photometric Accuracy | ±2.0% T |
| Photometric Stability | ≤0.3% drift over 3 min |
| Detection Limits & Ranges | Fructose + Glucose — LOD 12.0%, Range 0–95.0% w/w |
| Interface | RS-232, USB 2.0 |
| Power Options | Internal Rechargeable Li-ion Battery, DC 5 V Input, AC 220 V ±10% 50/60 Hz |
| Dimensions & Weight | 220 × 160 × 85 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-GYS2 |
| Wavelength Range | 400–680 nm |
| Detection Time | <2 min |
| Repeatability | <5% |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Stability (3 min) | ≤0.3% |
| Peroxide Value Detection Limit | 0.05 g/100g |
| Peroxide Value Range | 0.05–5.00 g/100g |
| Acid Value Detection Limit | 0.1 mg KOH/g |
| Acid Value Range | 0.0–30.0 mg KOH/g |
| Interface | RS232, USB |
| Power Supply | AC 220 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-NH2 |
| Price | USD 780 (FOB Shanghai) |
| Functionality | Single-Analyte Detection System |
| Sample Format | Single-sample cuvette-based assay |
| Wavelength Range | 400–680 nm |
| Analysis Time | <120 s per sample |
| Relative Standard Deviation (RSD) | <5% |
| Detection Channels | 1 |
| Detection Limit | 200.0 mg/kg |
| Quantification Range | 0–15,000 mg/kg |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability | ≤1.0% |
| Dark Current Drift | ≤0.5% over 3 min |
| Power Supply | AC 220 V / DC 12 V (with rechargeable 12 V Li-ion battery) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SP-Z2 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Type | Dedicated to Milk Powder & Liquid/Processed Dairy Matrices |
| Wavelength | 540 nm (Fixed-Channel Photometric Detection) |
| Assay Time | ≤180 seconds per sample |
| Photometric Repeatability | ≤0.2% CV |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SPb-201FM |
| Wavelength Range | 400–680 nm (discrete fixed wavelengths at 410 nm, 510 nm, 630 nm) |
| Detection Time | <2 min per sample |
| Repeatability | ≤5% CV |
| Optical Resolution | Absorbance 0.001 AU |
| Absorbance Range | 0.000–4.000 AU |
| Transmittance Range | 0.00–100.00% |
| Photometric Accuracy | ±2.0% T |
| Photometric Stability | ≤0.2% T (3 min) |
| Detection Channels | 1 |
| Sample Type | Liquid honey (pre-diluted or direct injection per protocol) |
| Compliance | Designed for routine QC in food processing labs compliant with GB 14963–2011 (Chinese National Standard for Honey), supports internal GLP documentation workflows |
| Connectivity | USB interface for data export |
| Power Supply | 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-AJ2 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Throughput | Single-Sample Mode |
| Optical Wavelength | 410 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (Transmittance) |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-BH2 |
| Price | USD 1,080 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Type | Dedicated Single-Sample Format |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 minutes |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-BJ2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Format | Single-Sample Mode |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (at 540 nm) |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-CX2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Dedicated Single-Sample Cartridge/Tube |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds per sample |
| Photometric Repeatability | ≤ 0.2% RSD |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | SPb-DB2 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Type | Solid/Liquid Food Matrices (Homogenized Extracts) |
| Optical Wavelength | 410 nm |
| Assay Time per Sample | ≤ 180 s |
| Photometric Repeatability (Transmittance) | ≤ 0.2% RSD |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-DL2 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Type | Single-Sample Format |
| Wavelength | 630 nm |
| Assay Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-DY2 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Functionality | Single-analyte, dedicated assay |
| Sample Type | Solid edible salt samples only |
| Wavelength | 540 nm |
| Assay Time | ≤3 min per sample |
| Photometric Repeatability | ≤0.2% (transmittance) |
| Optical Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy | ±2.0% (transmittance) |
| Baseline Stability | ≤0.3% over 3 min |
| LOD | 2.0 mg/kg |
| Quantitation Range | 0–80 mg/kg |
| Communication Interfaces | RS-232, USB |
| Power Supply | Rechargeable Li-ion battery (7.4 V, 4400 mAh), AC 220 V ±10%, DC 5 V input |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-EY2 |
| Price | USD 795 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Type | Single-Sample Dedicated Use |
| Optical Wavelength | 540 nm |
| Assay Time | ≤3 min per sample |
| Photometric Repeatability | ≤0.2% (Transmittance) |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy | ±2.0% (Transmittance) |
| Baseline Stability | ≤0.3% over 3 min |
| SO₂ LOD | 1.0 mg/kg |
| SO₂ Linear Range | 0–500 mg/kg |
| Communication Interfaces | RS-232, USB |
| Power Supply | Internal rechargeable Li-ion battery (7.4 V/2600 mAh), AC 220 V ±10%, DC 5 V input |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | SPb-GB2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Format | Single-Sample Mode |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (Transmittance) |
| Detection Channels | 1 |