| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HYG-16YB |
| Price | USD 16,500 (approx.) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Animal Tissues, Blood, Oral Fluids, Swabs, and Processed Food Matrices (e.g., Dumpling Fillings) |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤60 min (including nucleic acid extraction and amplification) |
| Repeatability | CV ≤0.2% |
| Detection Channels | 16 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | JCX-04D |
| Function Type | Multi-analyte (28 target parameters) |
| Sample Compatibility | Solid & liquid food matrices (meat, dairy, grains, oils, condiments, aquatic products, spices) |
| Optical Range | 400–680 nm |
| Assay Time | <2 minutes per test |
| Repeatability | CV <5% |
| Detection Channels | Single-channel (sequential analysis) |
| Kit Contents | 28 pre-formulated rapid test reagents, calibrated portable instruments (pH meter, moisture analyzer, conductivity meter), supporting labware (aluminum case, digital balance, homogenizer, pipettes, timers, glassware) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JCX-105 |
| Price | USD 630 (FOB) |
| Function Type | Multi-analyte Screening Platform |
| Sample Compatibility | Universal for Liquid & Semi-solid Food Matrices |
| Optical Range | 400–680 nm |
| Assay Time per Test | <2 minutes |
| Coefficient of Variation (CV) | <5% |
| Detection Channels | 10 simultaneous visual/semi-quantitative assays |
| Kit Capacity | 14 validated food safety parameters with defined reagent yields |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JCX-3SL |
| Price | USD 495 (FOB Shanghai) |
| Function Type | Multi-analyte (Clenbuterol, Ractopamine, Salbutamol) |
| Sample Compatibility | Urine, animal tissue, feed |
| Wavelength Range | 400–680 nm |
| Detection Time per Test | <2 min (instrument-assisted readout) |
| Coefficient of Variation (CV) | <5% |
| Detection Channels | 3 |
| Sensitivity | Clenbuterol — urine (3 ppb), tissue (5 ppb), feed (10 ppb) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JCX-JC10 |
| Price | USD 495 (FOB Shanghai) |
| Function Type | Multi-analyte Screening System |
| Sample Compatibility | Liquid Alcoholic Beverages, Distillates, Blended Spirits, Fermented Liquors |
| Wavelength Range | 400–680 nm |
| Detection Time | <120 seconds per sample |
| Coefficient of Variation (CV) | <5% |
| Optical Channels | Single-beam photometric detection |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JCX-STWS10 |
| Price | USD 285 (FOB Shanghai) |
| Detection Capabilities | ATP bioluminescence (surface hygiene), anionic synthetic detergent residue (MBAS assay), food core temperature (–50 to 200 °C), storage/refrigeration temperature (–32 to 400 °C), free chlorine concentration (50–2000 mg/L as Cl₂) |
| Net Weight | 3.0 kg |
| Carry Case | Aluminum alloy portable case (350 × 270 × 110 mm) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-102B |
| Price Range | USD 1,400–2,800 |
| Function Type | Multi-analyte Quantitative Immunoassay Reader |
| Sample Format | Single-strip Lateral Flow Assay (LFA) Cartridge |
| Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time | ≤ 180 s per strip |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-102Cd |
| Price Range | USD 1,400 – 2,800 |
| Function Type | Multi-analyte (Cadmium-focused with expandable panel) |
| Sample Applicability | Generic for cereal grains and milled rice matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per test |
| Repeatability (CV) | ≤0.3% |
| Detection Channels | 6 independent lateral-flow strip readers |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-102DY |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Format | Single-strip, Lateral Flow Assay (LFA) Cartridge |
| Optical Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time | ≤ 180 s per test |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Measurement Speed | < 0.5 s per image capture |
| Quantitative Precision | CV < 1% (using certified reference lateral flow strips) |
| Sensitivity Threshold | ≤ 0.001 OD unit (optical density) |
| Output Modes | Colorimetric analysis, C/T ratio calculation, Test line (T) and Control line (C) intensity quantification |
| Data Storage | 32 GB internal flash memory (≥100,000 assay records with full-image archiving) |
| Operating System | Windows 10 IoT Enterprise |
| Processor | Intel quad-core, 14 nm architecture |
| Display | 8.3-inch capacitive touchscreen (1280 × 800) |
| Connectivity | USB 2.0, Wi-Fi 802.11ac, Bluetooth 5.0, optional 4G LTE module |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Internal Battery | Rechargeable Li-ion, ≥24 h standby |
| Power Consumption | <10 W (operational) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-102JD |
| Function Type | Single-Analyte Rapid Immunoassay Platform |
| Sample Type | Egg and Duck Egg Matrix Only |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 180 s per test |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Measurement Speed | < 0.5 s per image capture |
| Optical Precision | CV < 1% (certified control strips), Inter-batch Variation < 3% |
| Sensitivity Threshold | < 0.001 ng/mL (matrix-dependent, per validated analyte) |
| Data Storage | 16 GB internal (expandable to 32 GB), ≥ 100,000 test records with full-image archiving |
| Power Supply | AC 220 V / 5 V DC / Internal Li-ion battery (≥24 h standby) |
| Power Consumption | < 10 W |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, Optional 3G/4G module |
| Output Formats | C/T line intensity ratio, colorimetric quantification, CT value, digital chromatographic profile export (CSV, PDF, XML) |
| Regulatory Alignment | Designed for compliance with GB/T 22286–2008, NY/T 761–2008, and supports audit-trail-ready data handling per GLP principles |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-102M |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Reader |
| Sample Format | Single-strip lateral flow assay (LFA) |
| Optical Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time per Test | ≤ 180 s |
| Photometric Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-103JS |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte (Cd, Pb, and expandable panel) |
| Sample Compatibility | Cereals, rice, flour, feed, edible oils, and processed food matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤180 seconds per sample |
| Repeatability (RSD) | ≤0.3% |
| Detection Channels | 3 independent optical lanes |
| Detection Limits | Cd ≤0.2 ppm, Pb ≤0.1 ppm |
| Measurement Speed | <1 second per test strip image capture |
| Output Metrics | Colorimetric intensity, C/T ratio, T-line intensity, C-line intensity, qualitative/quantitative classification |
| Interface | USB 2.0 |
| Connectivity | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 4G LTE module |
| Operating System | Android 7.0 |
| Hardware | Quad-core ARM processor, 2 GB RAM, 16 GB internal storage + microSD expansion |
| Display | 10.1-inch capacitive touchscreen |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Built-in Thermal Printer | Yes |
| Cloud Integration | HTTPS-based secure API for Ruixin Cloud Platform (ISO/IEC 27001-compliant infrastructure) |
| Data Compliance | Supports audit trail, user login authentication, and GLP-aligned electronic record retention |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JT-103M |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Versatility | Grain, Feed, Herbal Medicines, Edible Oils, Condiments, Milk & Dairy Products |
| Wavelength Range | 380–680 nm |
| Detection Time per Test | ≤ 180 s |
| Optical Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 3 independent optical lanes |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-103SY |
| Price | USD 5,300 (approx.) |
| Function Type | Multi-analyte Detection Platform |
| Sample Applicability | Universal for Animal-Derived Foods |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 3 minutes per test |
| Repeatability | ≤ 0.3% CV |
| Detection Channels | 3 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-108B |
| Price | USD 5,300 (approx.) |
| Functionality | Multiplex Rapid Screening Platform |
| Sample Versatility | Universal for Solid & Liquid Food Matrices |
| Optical Detection Range | 380–680 nm |
| Assay Time per Test | ≤ 180 s |
| Photometric Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 10 parallel optical lanes |
| Image Acquisition | High-Resolution CCD Sensor |
| Data Output | C/T Ratio, Colorimetric Intensity, Control Line (C), Test Line (T), Qualitative/Quantitative Interpretation |
| Connectivity | Wi-Fi 802.11 b/g/n, RJ45 Ethernet, USB 2.0, Optional 4G LTE Module |
| Operating System | Android 9.0 (Custom Embedded UI) |
| Display | 10.1-inch Capacitive Touchscreen |
| Onboard Storage | Internal eMMC + SD Card Slot (Supports ≥128 GB, >1,000,000 records) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Compliance | Designed to support ISO/IEC 17025-aligned laboratory workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JT-108Cd |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Versatility | Grain, Flour, Paddy, Polished Rice, and Processed Cereal Matrices |
| Optical Detection Range | 380–680 nm |
| Assay Time per Batch | ≤3 min (including image capture & AI quantification) |
| Photometric Repeatability (CV) | ≤0.3% |
| Detection Channels | 6 independent optical lanes |
| LOD for Cd in Rice | 0.1 ppm (mg/kg) |
| Imaging Speed | <1 s per test strip |
| Quantitative Accuracy | CV <1% (intra-assay, certified control strips), Inter-batch Variation <3% |
| Output Modes | Colorimetric Intensity, C/T Ratio, T-line Absorbance, C-line Normalization |
| Interface | USB 2.0, Wi-Fi 802.11 b/g/n, RJ45 Ethernet |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JT-108JS |
| Price Range | USD 2,800 – 4,300 (FOB Shanghai) |
| Function Type | Multi-analyte (Pb, Cd) |
| Sample Compatibility | Solid & semi-solid food matrices (grains, vegetables, herbs) |
| Wavelength Range | 380–680 nm |
| Detection Time per Sample | ≤15 min (full assay cycle) |
| Repeatability (CV) | ≤0.3% |
| Detection Channels | 10 independent optical channels |
| LOD for Cd | 0.2 ppm |
| LOD for Pb | 0.1 ppm |
| Imaging Speed | <1 s per strip |
| Quantification Accuracy | CV <1% (within-run, certified control strips) |
| Output Modes | Colorimetric intensity, C/T ratio, T-line presence/absence, C-line validation |
| Interface | USB 2.0 |
| Connectivity | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 4G LTE module |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JT-108JY |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Versatility | Grain, Legume, Leaf, and Processed Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time per Test | ≤ 180 s |
| Optical Reproducibility (CV) | ≤ 0.3% |
| Detection Channels | 10 parallel lateral-flow immunoassay (LFIA) readers |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | JT-108M |
| Detection Principle | Immunochromatographic Colloidal Gold Assay |
| Optical Detection Range | 380–680 nm |
| Detection Time | ≤ 3 min per sample |
| Measurement Speed | < 1 s per test strip |
| Detection Channels | 10 parallel |
| Repeatability (CV) | ≤ 0.3% |
| Precision | CV < 1% (standard test strips), inter-batch variation < 3% |
| Sensitivity | LOD down to 0.5 ppb (aflatoxin B₁ and M₁) |
| Quantitative Output | C/T ratio, colorimetric intensity, control line (C) & test line (T) signal analysis |
| Data Storage | Internal SD card support, ≥ 1 million records |
| Connectivity | Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module, GPS/AGPS |
| Display | 10.1-inch capacitive touchscreen, Android OS |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | Designed for ISO/IEC 17025-aligned workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JT-108NY |
| Detection Method | Colloidal Gold Immunochromatography with Spectrophotometric Quantification |
| Measurement Range | 0–100% relative signal intensity |
| Number of Channels | 10 |
| Measurement Error | <10% CV (at mid-range concentration) |
| Limit of Detection (LOD) | 0.2 ppm (matrix-dependent, typical for organophosphates and carbamates) |
| Measurement Speed | <1 s per test strip |
| Precision | Intra-assay CV <1% (standard reference strips), Inter-assay CV <3% |
| Output Parameters | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) signal |
| Power Supply | AC 220 V ±10%, 50 Hz (optional integrated Li-ion battery) |
| Connectivity | Wi-Fi (IEEE 802.11 b/g/n), RJ45 Ethernet, USB 2.0, optional 4G/LTE module |
| Display | 10.1-inch capacitive touchscreen, Android OS |
| Data Storage | Internal eMMC + microSD slot (up to 512 GB), >1 million records |
| Compliance | Designed to support traceability requirements aligned with China’s *Pilot Program for Edible Agricultural Product Qualification Certificate* (2020), QR code generation compliant with GB/T 38137–2019 (Traceability Code for Agricultural Products) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | JT-108SC |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Compatibility | Universal for Aquatic Products (e.g., shrimp, fish, crab, mollusks) |
| Wavelength Range | 380–680 nm |
| Detection Time per Test | ≤ 180 s |
| Repeatability (CV) | ≤ 0.3% |
| Number of Detection Channels | 6 |
| Measurement Speed per Strip | < 1 s |
| Precision | CV < 1% (certified control strips), Inter-batch Variability < 3% |
| Sensitivity | LOD ≤ 0.001 µg/kg (matrix-dependent, per analyte-specific validation) |
| Output Modes | Colorimetric Intensity, C/T Ratio, Test Line (T), Control Line (C) Quantification |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, Optional 4G LTE Module |
| Power Supply | AC 220 V ±10%, 50 Hz (with optional Li-ion battery pack for field use) |
| Compliance | Designed to support ISO/IEC 17025-aligned laboratory workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | JT-108SR |
| Price | USD 5,300 (approx.) |
| Function Type | Multi-analyte Screening Platform |
| Sample Compatibility | Universal for Porcine, Bovine & Ovine Tissues |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤180 s per assay |
| Repeatability (CV) | ≤0.3% |
| Detection Channels | 8 parallel optical readout units |
| Measurement Speed | <1 s per test strip |
| Precision | CV <1% (intra-assay, certified control strips) |
| Sensitivity | LODs ranging from 0.5 ppb (clenbuterol, salbutamol, ractopamine) to 100 ppb (ribavirin) |
| Output Modes | Chromaticity analysis, C/T ratio quantification, T-line intensity, C-line validation |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 4G LTE module |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating System | Android-based embedded UI |
| Display | 10.1-inch capacitive touchscreen |
| Data Storage | Internal eMMC + microSD expansion (≥1 million records) |
| Connectivity | Cloud API support, QR-code–enabled traceability, GPS/AGPS geotagging |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JT-108SY |
| Price | USD 3,950 (approx.) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Applicability | Universal for Animal-Derived Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 180 s per assay |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 6 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | JT-108SY |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Versatility | Universal for Animal-Derived Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 180 s per test strip |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 8 independent optical lanes |
| Measurement Speed | < 1 s per lane |
| Precision | CV < 1% (certified control strips), Inter-batch Variation < 3% |
| Sensitivity | LOD < 0.001 ng/mL (matrix-dependent, per analyte) |
| Output Modes | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) validation |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, Optional 4G LTE module |
| Power Supply | AC 220 V ±10%, 50 Hz (with optional Li-ion battery pack) |
| Operating System | Android 9.0 |
| Display | 10.1-inch capacitive touchscreen |
| Data Storage | Internal eMMC + microSD slot (up to 512 GB), ≥ 1,000,000 records |
| Connectivity Protocols | HTTP/HTTPS, MQTT, TLS 1.2 |
| Cloud Integration | RESTful API compliant with ISO/IEC 17025 traceability framework |
| Compliance | Designed in alignment with GB/T 27404–2008 (CNAS GLP guidelines), supports audit-ready data logs per FDA 21 CFR Part 11 requirements (electronic signatures, time-stamped audit trails, role-based access) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-108SYFM |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Format | Single-format Strip-Based Assay |
| Wavelength Range | 380–680 nm |
| Detection Time per Sample | ≤ 180 s |
| Photometric Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 8 parallel optical paths |
| Measurement Speed per Channel | < 1 s |
| Inter-batch CV | < 3% |
| Sensitivity Limit | ≤ 0.001 ng/mL (typical for chloramphenicol in honey matrix) |
| Output Metrics | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) signal |
| Power Supply | AC 220 V ±10%, 50 Hz (optional Li-ion battery pack available) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, RJ45 Ethernet, optional 4G LTE module |
| Data Storage | Internal eMMC + microSD slot (up to 128 GB), ≥ 1,000,000 test records |
| Compliance | Designed to support ISO/IEC 17025-aligned laboratory workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | JT-108Y |
| Price | USD 9,200 (approx.) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Compatibility | Universal for Solid & Liquid Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 180 seconds per test strip |
| Repeatability | ≤ 0.3% CV |
| Detection Channels | 10 independent optical channels |
| Measurement Speed | < 1 second per channel |
| Output Metrics | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) signal |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, Optional 4G LTE module |
| Positioning | Integrated GPS/AGPS |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Data Storage | Internal eMMC + microSD slot (up to 512 GB), ≥ 1,000,000 records |
| Display | 10.1-inch capacitive touchscreen, Android OS 11 |
| Printing Options | Thermal label printer (adhesive), thermal roll paper, A4 inkjet-compatible export |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JT-DB10NY |
| Price | USD 1,050 (FOB Shanghai) |
| Measurement Range | 0–1000 ppm |
| Number of Detection Channels | 1 |
| Detection Method | Colloidal Gold Immunochromatography |
| Measurement Accuracy | ±5% |
| Limit of Detection (LOD) | 0.01 ppm |
| Detection Time | <2 s per test |
| Display | 5-inch capacitive touchscreen (Android OS) |
| Power Supply | Rechargeable Li-ion battery (operational autonomy ≥8 h) |
| Data Output | C/T line intensity ratio, chromaticity value, qualitative/quantitative result classification |
| Connectivity | Wi-Fi, Bluetooth 4.2, USB 2.0 |
| Data Management | Cloud synchronization, local storage (≥10,000 records), CSV export |
| Compliance | Aligned with MOA Notice No. 102 (2022), “Three-Year Action Plan for Illegal Drug Control and Residue Reduction in Edible Agricultural Products”, and Technical Guidance for Quality & Safety Control of Cowpea, Leek, and Celery (MOA, 2023) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-K100 |
| Detection Method | Colloidal Gold Immunochromatography |
| Measurement Range | 0.5–1000 ppb |
| Number of Test Lines | 1 |
| Quantitative Accuracy (CV) | ≤1% |
| Limit of Detection (LOD) | 0.5 ppb |
| Brand | Ruixin |
|---|---|
| Model | JT-K10SY |
| Origin | Shanghai, China |
| Type | Lateral Flow Immunoassay (LFIA) Test Strip |
| Format | Single-use, qualitative/semi-quantitative rapid detection card |
| Pack Size | 20 tests per box |
| Detection Principle | Colloidal gold-labeled antibody-based competitive or sandwich immunoassay |
| Target Analytes | Chloramphenicol (0.1 ppb), Malachite Green (0.5 ppb), Diazepam (0.5 ppb), Fluoroquinolones (3 ppb), Olaquindox metabolite (2 ppb), Furazolidone metabolite (0.5 ppb), Furaltadone metabolite (0.5 ppb), Nitrofurantoin metabolite (0.5 ppb), Nifursol metabolite (0.5 ppb), Sulfonamides (5 ppb), Tetracyclines (10 ppb), Penicillins (20 ppb), Diethylstilbestrol (10 ppb), Enrofloxacin (10 ppb), Ofloxacin (1 ppb), Ciprofloxacin (10 ppb), Sarafloxacin (40 ppb), Danofloxacin (50 ppb), Amantadine (2 ppb), Dexamethasone (1 ppb), Chlorpromazine (10 ppb), Florfenicol (0.2 ppb), Metronidazole (3 ppb), Tilmicosin (10 ppb), Clopidol (200 ppb), Streptomycin (20 ppb), Gentamicin (10 ppb), Erythromycin (20 ppb), Oxytetracycline (20 ppb), Chlortetracycline (100 ppb), Sulfadimidine (25 ppb), Ceftiofur (100 ppb), Cefotaxime (200 ppb), Ceftriaxone (50 ppb), Ampicillin (50 ppb), Amoxicillin (20 ppb), Sodium Pentachlorophenate (1 ppb), Avermectins (20 ppb), Thiamphenicol (50 ppb), Apramycin (100 ppb), Methyltestosterone (100 ppb), Nicarbazin (20 ppb), Hydrocortisone (1 ppb), Albendazole (10 ppb), Tylosin (100 ppb), Microcystin-LR (1 ppb), Rosiglitazone (50 ppb), Trimethoprim (50 ppb) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | NC-32ZD |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 32 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm (for methamidophos) |
| Wavelength Options | 340, 410, 450, 510, 546, 630 nm |
| Reaction Temperature | 37 ± 1 °C (software-adjustable) |
| Transmittance Accuracy | ±1.5% |
| Transmittance Repeatability | ≤0.5% |
| Absorbance Drift | ≤0.005 Abs/3 min |
| Inhibition Rate Repeatability | ≤5% |
| Power Supply | AC 100–240 V, 50/60 Hz, 102 W |
| Dimensions | 468 × 270 × 290 mm |
| Weight | ~13 kg |