SMACH
Filter
Showing all 29 results
| Brand | SMACH |
|---|---|
| Model | ERM202 |
| Instrument Type | In-line Gamma Spectrometric Monitor for Aqueous Effluents |
| Detector Type | NaI(Tl) Scintillation Detector (φ30 × 25 mm) |
| Measurement Range | 0.5–100,000 Bq/L (for artificial radionuclides) |
| Sensitivity | < 5 Bq/m³ (referenced to ¹³⁷Cs) |
| Energy Range | 48 keV – 3 MeV |
| Energy Resolution | ≤ 8% FWHM at 662 keV |
| Multichannel Analyzer | 2048 channels |
| Accuracy | ±10% (relative activity measurement) |
| Automatic Spectrum Stabilization | ⁴⁰K-based |
| Shielding | 50 mm lead layer within 304 stainless steel flow cell |
| Communication | RS485, Modbus RTU protocol |
| Power Supply | 220 VAC / 50 Hz |
| Data Storage | 200,000 gamma spectra |
| Reporting Interval | Configurable from 1–150 min (default: 10 min) |
| Temperature Compensation | Real-time automatic correction |
| Alarm Modes | Radionuclide-specific activity threshold alarm & dose rate exceedance alarm |
| Brand | SMACH |
|---|---|
| Model | LX100D |
| Type | Portable Dose Rate Meter |
| Detector | Plastic Scintillator |
| Measured Radiation | X-ray and γ-ray |
| Dose Rate Range | 100 nSv/h to 10 Sv/h |
| Sensitivity | 100 cps/μSv/h |
| Energy Response | 25 keV – 7.0 MeV |
| Intrinsic Relative Error | ≤10% |
| Operating Temperature | −40 °C to +55 °C |
| IP Rating | IP65 |
| Battery Life | 12 h continuous operation |
| Communication Interfaces | RS232, RS485, Bluetooth, LoRa, ZigBee, Cellular, Wi-Fi |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NCR2 |
| Instrument Category | Radiation Dose Rate Meter / Activity Monitor |
| Instrument Type | Online, Standalone In Vivo Monitoring System |
| Detection Medium | Human Body (Post-Therapeutic/Diagnostic Patients) |
| Detector Type | Scintillation Detector (NaI(Tl) or LaBr3-based) |
| Measurement Capability | Multi-nuclide Quantification (I-131, Tc-99m, F-18, etc.) |
| Activity Range | 0.1–500 mCi (3.7 MBq–18.5 GBq) |
| Sensitivity | High-Sensitivity Scintillation Detection Unit |
| Measurement Time | ~30 s per subject |
| Output Units | Bq, MBq, Ci, CPS |
| Compliance | Designed in accordance with GBZ 120–2020, IAEA Safety Standards Series No. GSR Part 3, ICRP Publication 103, and US NRC Regulatory Guide 8.39 |
| Brand | SMACH |
|---|---|
| Model | R-EGD |
| Type | Portable Dose Rate & Integrated Dose Meter |
| Detector | Geiger-Müller (G-M) Tube |
| Measured Radiation | X-rays and Gamma (γ) Rays |
| Dose Rate Range | 0.01 µSv/h – 15 mSv/h |
| Integrated Dose Range | 0.00 µSv – 9.99 Sv |
| Sensitivity | 80 CPM per µSv/h (typical, referenced to ¹³⁷Cs) |
| Energy Response | ±30% from 48 keV to 3.0 MeV (¹³⁷Cs calibrated) |
| Angular Dependence | ≤25% deviation at 0°–90° relative to calibration axis |
| Accuracy | ±5% in dose rate range 0.01–1000 µSv/h (¹³⁷Cs) |
| Display Units | µSv/h (dose rate), µSv (integrated dose) |
| Power | Rechargeable 3.7 V Li-ion battery |
| Weight | 700 g (with battery) |
| Dimensions | 200 × 100 × 35 mm |
| Audible Alarm | >80 dB at 50 cm |
| Operating Temperature | −10 °C to +50 °C |
| Compliance | Meets IEC 60846-1:2014 requirements for portable radiation protection instruments |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RC Series |
| Instrument Type | Gamma Spectrometer |
| Detector Material | Imported Plastic Scintillator |
| Energy Range | 20 keV – 3 MeV |
| Detection Sensitivity | Up to 4 × 60,000 cps/µSv/h (at background 0.2 µSv/h, Δ0.1 µSv/h in 1 s) |
| Detection Probability | ≥99.99% |
| False Alarm Rate | ≤0.01% |
| Standard Vehicle Speed | 8 km/h |
| Max Vehicle Speed | 20 km/h |
| Monitoring Height Range | 0.1–4.5 m (RC4025), 0.1–3.5 m (RC2025), 0.1–1.0 m (RC2010) |
| Width Coverage | 6 m (dual-side), 1 m (pedestrian) |
| Operating Temperature | −30 °C to +60 °C |
| IP Rating | IP65 |
| Power Supply | 220 V AC / 50 Hz |
| Data Storage | 1 TB HDD (≥400,000 records, ≥10 years retention) |
| Communication Interfaces | RS232 / RS485 / Ethernet / TCP/IP / GPRS (optional) |
| Compliance | GB/T 24246–2009, IAEA Nuclear Security Series No. 1 |
| Brand | SMACH |
|---|---|
| Model | RC1010 |
| Instrument Type | Radiation Dose Rate Meter |
| Gamma Detector | Plastic Scintillator (10 L volume) |
| Energy Response Range | 25 keV – 3 MeV |
| Gamma Sensitivity | >24,000 cps/µSv/h per detector |
| Neutron Detection Option | Ø25 mm × 600 mm He-3 tube (3,000 n/s detectable) |
| Dynamic Detection Capability | ≥5 × 10⁵ Bq ¹³⁷Cs |
| False Alarm Rate | ≤0.1% |
| Height Coverage | 0.1–2 m |
| Width Coverage | 1.5 m |
| Non-Detection Side Shielding | 5 mm lead equivalent |
| Artificial vs. Natural Radionuclide Discrimination | Yes |
| Compliance | Designed for IAEA RS-G-1.9, ANSI N42.34, and EU Council Directive 2013/59/Euratom requirements |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | RC2010 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Category | Radiation Dose Rate Meter |
| Instrument Type | Online Continuous Monitoring System |
| Measured Radiation | X-ray and Gamma (γ) Radiation |
| Detector Type | Plastic Scintillator (BC-408 or EJ-200 equivalent) |
| Detection Aperture | Height 0.1–2.0 m |
| Sensitivity | >24,000 cps per µSv/h (per detector unit) |
| Energy Response Range | 25 keV – 3 MeV |
| False Alarm Rate | ≤0.1% |
| Neutron Detection Option | Optional ³He tube (Φ25 mm × 600 mm), sensitivity ≥3,000 n/s |
| Dynamic Detection Threshold | ≥5×10⁵ Bq ¹³⁷Cs at walking speed (1.2 m/s) |
| Shielding on Non-Detection Faces | 5 mm lead equivalent |
| Artificial vs. Natural Radionuclide Discrimination | Enabled via spectral analysis and adaptive threshold algorithm |
| Compliance | Designed to meet IEC 62401:2010 (Radiation Protection Instruments – Portal Monitors for Radioactive Material), ANSI N42.35-2022 (Performance Criteria for Hand-Held Instruments and Portal Monitors for Detection of Radioactive Material), and supports GLP/GMP-aligned audit trail logging in optional software configuration |
| Brand | SMACH |
|---|---|
| Model | RC2025 |
| Origin | Fujian, China |
| Detector Type | Plastic Scintillator |
| Radiation Type | Gamma (γ) |
| Energy Response Range | 50 keV – 3 MeV |
| Gamma Sensitivity | >60,000 cps/μSv/h per detector unit |
| Dynamic Detection Capability | ≥5×10⁶ Bq ¹³⁷Cs |
| Neutron Sensitivity | Detectable ≥20,000 n/s neutron source |
| False Alarm Rate | ≤0.1% |
| Non-Detection Side Shielding | 5 mm lead-equivalent |
| Height Coverage | 0.1–3 m |
| Width Coverage | 5 m |
| Nuclear Isotope Discrimination | Artificial vs. Natural Radionuclides |
| System Architecture | Modular, Online, Real-Time |
| Compliance | Designed for IAEA RS-G-1.9, ANSI N42.34, and ISO 28000-aligned operational environments |
| Brand | SMACH |
|---|---|
| Model | RD200 |
| Type | Portable Dose Rate & Integrated Dose Meter |
| Detector | Energy-Compensated Geiger-Müller Tube |
| Radiation Type | X-ray and Gamma (γ) |
| Dose Rate Range | 0.01 µSv/h to 15 mSv/h (optional up to 150 mSv/h) |
| Sensitivity | 5 CPS per µSv/h (optional 1200 CPS/µSv/h) |
| Energy Range | 48 keV – 3.0 MeV |
| Energy Response | ≤ ±30% |
| Accuracy | ≤ ±8% |
| Display Units | µSv/h, mSv/h, Sv/h, Gy/h, CPS, µSv, mSv, Sv, Gy |
| Operating Temperature | −10 °C to +50 °C |
| Weight | 280 g (incl. battery) |
| Dimensions | 165 × 72 × 38 mm |
| Power | Rechargeable Li-ion battery |
| Power Consumption | ≤120 mW (excl. backlight) |
| Compliance | Designed for IEC 60846-1:2014 (Radiation protection instrumentation — Dose rate meters and ambient and/or directional dose equivalent rate meters for beta, X and gamma radiation) |
| Brand | SMACH |
|---|---|
| Model | RD300 |
| Type | Portable Dose Rate Meter |
| Detector | Ø30×25 mm NaI(Tl) Scintillation Crystal |
| Radiation Types | X-ray & Gamma-ray |
| Dose Rate Range | 0.01–600.00 µSv/h |
| Accumulated Dose Range | 0.00 µSv–999.9 Sv |
| Sensitivity | ≥350 cps per µSv/h |
| Energy Response | 48 keV–3 MeV |
| Accuracy | ≤±5% at 200.00 µSv/h |
| Measurement Time | 5–120 s (user-configurable) |
| Display | Backlit Color LCD with Adjustable Brightness |
| Units | µSv/h, µGy/h, µSv, CPS |
| Operating Temperature | −10°C to +50°C |
| Power | Rechargeable Li-ion battery + 2×D-cell backup |
| Weight | 1.55 kg (with battery) |
| Dimensions | 420 × 180 × 88 mm |
| Housing | Anodized Aluminum Alloy |
| Compliance | Meets IEC 60846-1:2014 and GB/T 10257–2022 requirements for portable radiation survey instruments |
| Brand | SMACH |
|---|---|
| Model | RD500 |
| Detector Type | NaI(Tl) Scintillation + Energy-Compensated GM Tube |
| Measurement Range | 1 nSv/h – 100 µSv/h (NaI mode) |
| Sensitivity | ≥1200 cps/µSv/h (for ¹³⁷Cs, NaI) |
| Energy Response | 48 keV – 3 MeV (±20% relative to ¹³⁷Cs) |
| Display Units | µGy/h, µSv/h, cps |
| Operating Temperature | −20 °C to +50 °C |
| Weight | 2.65 kg |
| Power | Rechargeable Li-ion Battery (72 h continuous operation) |
| Connectivity | Wired (Micro-USB) and Wireless (2.4 GHz RF), Ethernet port, USB data export |
| Compliance | Designed for environmental radiation monitoring per IEC 60846-1:2014, ISO 4037-3, and national standards for environmental dose rate instrumentation |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Model | RD700 |
| Instrument Type | Online Dosimeter |
| Measurement Range | 0.01 µGy/h – 100 mGy/h |
| Detector Type | Dual Scintillation Detector |
| Radiation Types | X-ray and γ-ray |
| Sensitivity | 30 cps |
| Communication | 4G LTE (GPRS-based), Optional Emergency Radio Mode |
| Positioning | Dual-mode GNSS (GPS + BeiDou) |
| Environmental Rating | IP67 |
| Operating Temperature | −30 °C to +50 °C |
| Battery Life | Up to 20 days (480 h) on rechargeable battery |
| Data Upload Interval | Configurable from 30 s to 24 h |
| Compliance | Designed for IEC 60846-1:2014 (Radiation protection instrumentation — Dose rate meters and alarm dose rate meters for beta, X and gamma radiation) |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Model | RD800 |
| Instrument Type | Portable Dose Rate Meter |
| Detection Principle | Scintillation + Geiger-Müller (GM) Dual-Detector Architecture |
| Measured Radiation | X-rays and γ-rays |
| Dose Rate Range | 0.01 μSv/h to 15 mSv/h (GM mode) |
| Sensitivity | 100 cps per μSv/h (¹³⁷Cs reference) for scintillator |
| Energy Response | 48 keV – 3 MeV (scintillator) |
| Detector Dimensions | Φ35 × 32 mm (active), Φ50 × 70 mm (housing) |
| IP Rating | IP68 |
| Operating Temperature | −25 °C to +50 °C |
| Positioning | Dual-band GNSS (GPS + BeiDou) |
| Data Storage | ~2000 records with timestamp, dose rate, accumulated dose, geotag, alarm status |
| Connectivity | 4G LTE full-network support |
| Power | Rechargeable Li-ion battery with extended field endurance |
| Telescopic Probe Rod | Adjustable length 1.0–4.5 m (standard) |
| Compliance | Designed to meet IEC 60846-1:2014 (radiation protection instrumentation — ambient and/or directional dose equivalent [rate] meters and/or monitors for beta, X and gamma radiation) |
| Software Compatibility | PC-based data export in .xlsx format with audit-ready metadata (time, location, detector ID, measurement mode) |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Model | RE3000 |
| Instrument Type | Portable Dose Rate Meter |
| Detector | Ø30×25 mm NaI(Tl) Scintillation Crystal |
| Measurement Range | Dose Rate: 0.01–200.00 µSv/h |
| Cumulative Dose | 0.00 µSv–9.99 Sv |
| Sensitivity | ≥350 CPS/µSv/h |
| Energy Range | 38 keV–3 MeV |
| Relative Error | ≤±8% (at 200.00 µSv/h) |
| Measurement Time | Adjustable from 1–60 s |
| Alarm Thresholds | User-Configurable for Dose Rate & Cumulative Dose |
| Power | Rechargeable Li-ion Battery |
| Weight | 1.85 kg (total system) |
| Dimensions (Host) | 420×180×88 mm |
| Maximum Telescopic Rod Length | 3.5 m |
| Bluetooth Communication Range | Up to 15 m |
| IP Rating | IP68 |
| Data Storage | Local 4 GB + microSD card expansion |
| Display | Capacitive Touchscreen with Dual-Language (EN/CN) UI |
| Brand | SMACH |
|---|---|
| Model | RG1000 |
| Instrument Type | Portable Dosimeter/Alarm |
| Detector Type | Energy-Compensated GM Tube |
| Measured Radiation | X and γ Rays |
| Dose Equivalent Rate Range | 0.00 µSv/h – 10 mSv/h |
| Cumulative Dose Equivalent Range | 0.00 µSv – 10 Sv |
| Sensitivity | ≥1.5 CPS/µSv/h (relative to ¹³⁷Cs) |
| Energy Response | 48 keV – 3.0 MeV |
| Relative Error | <10% at 1 mSv/h |
| Operating Temperature | −10 °C to +50 °C |
| Humidity Range | 0–95% RH (at +35 °C) |
| Dimensions | 100 × 60 × 26 mm |
| Power Supply | Two AAA batteries |
| Brand | SMACH |
|---|---|
| Model | RG1100 |
| Type | Portable Dose Rate and Accumulated Dose Monitor |
| Detector | Energy-Compensated GM Tube |
| Radiation Type | X-ray and Gamma (γ) Radiation |
| Dose Equivalent Rate Range | 0.01 µSv/h – 1 mSv/h |
| Accumulated Dose Equivalent Range | 0.00 µSv – 999.9 Sv |
| Sensitivity | >1.5 CPS/µSv/h (relative to ¹³⁷Cs) |
| Energy Response | 48 keV – 3.0 MeV |
| Relative Error | <5% at 1 mSv/h |
| Operating Temperature | −10 °C to +50 °C (±10% drift) |
| Humidity Range | 0–95% RH at +35 °C (±10% drift) |
| Dimensions | 70 × 40 × 95 mm (L×W×H) |
| Weight | 100 g (including batteries) |
| Power Supply | Two AA alkaline cells |
| Display | OLED with bilingual (English/Chinese) UI |
| Alarm Modes | Audible, visual (LED flash), and vibration |
| Data Logging | Automatic alarm event storage |
| Optional Feature | Wireless mesh networking for centralized dose management |
| Brand | SMACH |
|---|---|
| Model | RG1300 |
| Type | Portable Radiation Dosimeter & Dose Rate Meter |
| Detector | Energy-Compensated GM Tube |
| Radiation Types | X-ray and Gamma (γ) |
| Dose Rate Range | 0.01 µSv/h to 10 Sv/h |
| Dose Accumulation Range | 0.01 µSv to 9.99 Sv |
| Energy Response | 48 keV – 3 MeV |
| Accuracy | ≤ ±15% at 1 mSv/h |
| Display | 1.54" OLED |
| Operating Temperature | −10 °C to +50 °C |
| Humidity Range | 0–95% RH (at 35 °C) |
| Dimensions | 92 × 59 × 13 mm |
| Weight | ~93 g (incl. belt clip) |
| Power | Rechargeable Li-ion battery with continuous charge-level monitoring |
| Alarm Modes | Audible, visual (LED flash), and vibrotactile |
| Data Retention | Non-volatile memory preserves accumulated dose, dose rate threshold, and dose alarm threshold after power loss |
| User Interface | Dual-language (English/Chinese) menu system |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Model | RG391 |
| Instrument Type | Portable Alpha/Beta Radiation Contamination Monitor |
| Detector Type | Silicon Semiconductor |
| Measurement Range | 1–99,999 counts per second (cps) |
| Detection Efficiency | α ≥ 35%, β ≥ 40% |
| Alpha Energy Range | 2–6 MeV |
| Background | α < 1 cpm, β < 60 cpm (at 0.25 µSv/h ambient dose rate) |
| Adjustable Alpha Alarm Threshold | 1–200 cpm |
| Dose Rate Range (Host) | 0.01 µSv/h – 10 mSv/h |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | ≤95% RH at 35 °C |
| Active Detection Area | 3.14 cm² |
| Power Supply | Rechargeable Lithium-ion Battery |
| IP Rating | IP67 (Waterproof & Dustproof Enclosure) |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Model | RL5000 |
| Instrument Type | Online Dose Rate Meter |
| Detector Type | Compensated GM Tube |
| Measured Radiation | X- and γ-rays |
| Measurement Range | 0.01 µSv/h to 15 mSv/h (optional: up to 1 Sv/h) |
| Sensitivity | ≥1.5 CPS/µSv/h |
| Energy Response | 38 keV – 3.0 MeV |
| Response Time | ≤1 s |
| Display | 5.7″ LCD (160×160 dot matrix) |
| Operating Temperature | −10 °C to +45 °C |
| Relative Humidity | ≤98% at 40 °C |
| IP Rating | IP65 (optional IP68) |
| Communication | RS485 (Modbus RTU), up to 800 m |
| Max. Connected Probes | 30 |
| Alarm Modes | Upper limit / Lower limit / Dual-limit |
| Default Threshold | 2.5 µSv/h (user-adjustable) |
| Power Supply | 220 VAC to 5 VDC adapter |
| Enclosure Dimensions | 280 × 350 × 100 mm (excl. mounting base) |
| MTBF (Probe) | ≥8,000 h |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RL5100 |
| Price Range | USD 700–1,400 (FOB) |
| Instrument Category | Radiation Dose Rate Meter |
| Instrument Type | Fixed Online Monitor |
| Measured Radiation | X-ray and Gamma (γ) Radiation |
| Detector Type | Compensated GM Tube |
| Measurement Range | 0.01 µSv/h to 15 mSv/h (optional extended range: 0.01 µSv/h to 1 Sv/h) |
| Sensitivity | ≥1.5 CPS per µSv/h |
| Energy Response | 38 keV – 3.0 MeV |
| Response Time | ≤1 s (alarm), ≤3 s (full stabilization) |
| Display | 160×160 dot-matrix LCD with Chinese UI (configurable for English firmware on request) |
| Communication | RS485 (Modbus RTU), up to 800 m |
| Power Supply | AC 220 V ±10%, 50 Hz (standard) |
| Operating Temperature | −10 °C to +45 °C |
| Relative Humidity | ≤98% at 40 °C |
| Enclosure Rating (probe) | IP65 (IP68 optional) |
| MTBF (probe) | ≥8,000 h |
| Compliance | Designed in accordance with IEC 60846-1:2014 (Radiation protection instrumentation — Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation), GB/T 10257–2022 (Chinese national standard for radiation monitoring instruments), and compatible with GLP/GMP-aligned data integrity workflows |
| Brand | SMACH |
|---|---|
| Model | RM200 |
| Instrument Type | Online Radiation Dose Rate Meter |
| Detector Type | Energy-Compensated Geiger-Müller (GM) Tube |
| Measured Radiation | X-ray and Gamma (γ) Radiation |
| Dose Rate Range | 0.01 µGy/h to 10 mGy/h |
| Sensitivity | 5 CPS per µGy/h (relative to ¹³⁷Cs) |
| Energy Response Range | 48 keV – 1.3 MeV |
| Measurement Accuracy | ≤ ±10% at 1 mGy/h |
| Response Time | ≤ 2 s (from background to 5 µGy/h step change) |
| Display | High-Resolution LCD |
| Alarm Modes | Visual (LED), Audible (Buzzer), On-Screen Alert |
| Communication Interfaces | Ethernet (RJ45), Wi-Fi (IEEE 802.11 b/g/n) |
| Power Supply | DC 5 V (AC 220 V / 50 Hz adapter included) |
| Dimensions | Ø120 mm × 41 mm |
| Operating Temperature | −10 °C to +50 °C |
| Compliance | Meets IEC 60846-1:2014 (Radiation Protection Instruments – Dose Rate Meters) for environmental monitoring applications |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RN200 |
| Instrument Class | Neutron Dose Rate Meter |
| Form Factor | Portable |
| Radiation Type | Neutrons (n) |
| Detector Type | Pressurized He-3 Proportional Counter with Spherical Polyethylene Moderator |
| Measurement Range | 0.01 µSv/h – 99.99 mSv/h |
| Sensitivity | 2.83 cps/(nSv/h) referenced to ²⁵²Cf neutron source |
| Energy Response | 0.025 eV – 15 MeV |
| Angular Response Deviation | < ±10% over 4π geometry |
| Accuracy | ±10% (relative error) |
| IP Rating | IP65 |
| Operating Temperature | −15 °C to +50 °C |
| Battery Life | >30 h continuous operation |
| Communication Interface | USB |
| Alarm | Adjustable threshold with audible, visual, and vibration alerts |
| Cumulative Dose Range | 0.01 µSv – 9999 mSv |
| Moderator Dimensions | Ø210 mm × 320 mm, mass 5.5 kg |
| Moderator Material | Low-density polyethylene (ρ = 0.95 g/cm³) |
| Brand | SMACH |
|---|---|
| Model | RP-6000 |
| Detector Type | NaI(Tl) Scintillation Crystal (Φ30×25 mm) |
| Measurement Types | X-ray & Gamma-ray |
| Dose Rate Range | 0.01–200.00 µSv/h |
| Accumulated Dose Range | 0.00 µSv–9.99 Sv |
| Sensitivity | ≥350 CPS per µSv/h |
| Energy Response Range | 38 keV–3 MeV |
| Relative Error | ≤±8% at 200.00 µSv/h |
| Measurement Time | Adjustable from 5 to 120 seconds |
| Display | Color LCD with adjustable backlight |
| Alarm Functions | Configurable dose rate & accumulated dose thresholds, overload, low-battery, and detector fault alerts |
| Power Supply | Two D-cell batteries |
| Weight | 1.30 kg (including batteries) |
| Dimensions | 420 × 180 × 88 mm |
| Compliance | Designed for field-deployable radiation safety monitoring in accordance with IEC 60846-1:2014 and ISO 4037-3 standards |
| Brand | SMACH |
|---|---|
| Model | RP6000 |
| Detector | Ø30×25 mm NaI(Tl) Scintillation Crystal |
| Dose Rate Range | 0.01–200.00 µSv/h |
| Cumulative Dose Range | 0.00 µSv–9.99 Sv |
| Sensitivity | ≥350 cps per µSv/h |
| Energy Response | 15 keV–3 MeV |
| Relative Error | ≤±8% at 200.00 µSv/h |
| Measurement Time | 5–120 s (adjustable) |
| Display | Color LCD with adjustable backlight |
| Alarm Functions | Configurable dose rate & cumulative dose thresholds, overload, low-battery, and detector fault alerts |
| Data Logging | Timed measurement storage & alarm event recall |
| Power | Two standard No. 1 batteries (≤200 mW system power, excluding backlight) |
| Weight | 1.30 kg (with batteries) |
| Dimensions | 420 × 180 × 88 mm |
| Housing | Anodized aluminum alloy |
| Compliance | Designed for IEC 60846-1:2014 (Radiation protection instrumentation — Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation) |
| Optional Features | Door interlock interface, wireless mesh networking capability, USB/Bluetooth data export |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | RP6100 |
| Instrument Type | Radiation Dose Rate Meter |
| Detector Configuration | Dual Detector (NaI(Tl) Scintillator + GM Tube) |
| Dose Rate Range | 0.01–200.00 µSv/h (optional extended range: 0.01 µSv/h–10 mSv/h) |
| Accumulated Dose Range | 0.00 µSv–999.99 Sv |
| Sensitivity | ≥500 cps per µSv/h (relative to ¹³⁷Cs) |
| Energy Response | 15 keV–3 MeV |
| Relative Measurement Uncertainty | ≤±8% at 200.00 µSv/h |
| Measurement Interval | 5–120 s (user-configurable) |
| Display | Color LCD with adjustable backlight |
| Alarm Functions | Programmable dose rate & accumulated dose thresholds, overload, low-battery, and detector fault alerts |
| Data Logging | Time-stamped measurement records with query capability |
| Power Supply | Two standard No. 1 (D-cell) batteries |
| Power Consumption | ≤200 mW (excluding backlight) |
| Weight | 1.35 kg (including batteries) |
| Dimensions | 420 × 180 × 88 mm |
| Housing | Anodized aluminum alloy |
| Optional Features | Door interlock interface, wireless mesh networking module, USB/RS232 data export |
| Brand | SMACH |
|---|---|
| Model | RS1050 |
| Type | Portable Dose Rate Meter |
| Detector | End-Window Mica Geiger-Müller Tube |
| Detection Radiation | Alpha, Beta, Gamma, and X-rays |
| Dose Rate Range | 0.01 µSv/h – 1 mSv/h (extendable to 150 mSv/h) |
| Dose Accumulation Range | 0.001 µSv – 999 Sv |
| Sensitivity | 5800 cpm/mR/h (for ⁶⁰Co) |
| Detector Active Area | 33 cm² (65 mm effective diameter) |
| Accuracy | ±15% (relative to ¹³⁷Cs) |
| Operating Temperature | −40 °C to +75 °C |
| Power | Two C-size alkaline batteries |
| Data Storage | 2000 manual/automatic entries + SD card logging |
| Display | Backlit color LCD with bar graph and simultaneous multi-parameter readout |
| Alarm Types | Dose rate threshold, accumulated dose threshold, pulse rate threshold, detector fault, low battery, over-range |
| Compliance | Designed for field use in accordance with IEC 60846-1:2014 (Radiation protection instrumentation — Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation) |
| Brand | SMACH |
|---|---|
| Origin | Fujian, China |
| Model | RS2100 |
| Instrument Type | Portable |
| Detector Type | Plastic Scintillator + ZnS(Ag) |
| Radiation Types | Alpha and Beta |
| Count Rate Range | 0–1×10⁵ cps |
| Sensitivity | 233 cps/(Bq·cm⁻²) (for ²⁴¹Am) |
| Detection Efficiency | ≥52% (²⁴¹Am), ≥17% (¹⁴C), ≥48% (²⁰⁴Tl), ≥50% (⁹⁰Sr/⁹⁰Y), ≥45% (¹³⁷Cs) |
| Effective Detection Area | 100 cm² (10×10 cm) |
| Window Material | Aluminized Polyester Foil |
| Beta Energy Range | 150 keV – 2.5 MeV |
| Display | 128×64 Dot-Matrix LCD |
| Power Supply | Standard C-Cell Alkaline or Rechargeable Batteries |
| Battery Life | ~150 h (backlight off) |
| Weight | ~1.0 kg |
| Units | cps, cps/cm², Bq, Bq/cm² |
| Alarm | Dual Adjustable Thresholds |
| Interface | USB Serial Communication |
| Housing | Impact-Resistant Enclosure |
| Detector Assembly | Vacuum-Sealed with Quick-Replace Aluminum Foil Window |
| Brand | SMACH |
|---|---|
| Model | RZ500 |
| Instrument Type | Benchtop Alpha/Beta Scintillation Counter for Nasal Swab Assays |
| Detection Principle | ZnS(Ag)/Plastic Scintillation |
| Measurement Range | 0–10,000 cps |
| Sensitivity | ≥0.1 Bq/m³ for ²³⁹Pu α-activity (air-equivalent) |
| Detector Window Diameter | 30 mm |
| Detection Efficiency | ²³⁹Pu ≥28%, ⁹⁰Sr–⁹⁰Y ≥50%, ³⁶Cl ≥42%, ⁶⁰Co ≥10%, ²⁴¹Am ≥40% |
| Background Count Rate | α ≤0.005 cm⁻²·min⁻¹ |
| Intrinsic Error | ±10% (max) |
| Display | 7-inch capacitive touchscreen |
| Power | AC adapter + rechargeable Li-ion battery (≥30 h runtime) |
| Operating Temperature | −10 °C to +50 °C |
| Weight | ~13 kg |
| Compliance | Designed per IEC 61000-4 EMC standards |
| Brand | SMACH |
|---|---|
| Model | ZY330 |
| Detection Principle | Beta-ray attenuation (¹⁴C source) |
| Effective Window Diameter | 25 mm |
| Supply Voltage | ±11.5–±12.5 V DC |
| Current Consumption | ≤50 mA (+12 V), ≤10 mA (−12 V) |
| Output Signal | Positive TTL |
| Pulse Width | 500 ± 100 ns |
| Pulse Amplitude | 5.0 ± 0.2 V |
| Background Count Rate | ≤3 cps |
| Measurable Count Rate Range | 315–385 kcps |
| 1-Hour Stability | ≤0.3% |
| Operating Temperature | 0–40 °C (≤90% RH, non-condensing) |
| Storage Temperature/Humidity | −20–+50 °C (≤93% RH) |