Thermo Fisher Scientific
Filter
Showing 271–300 of 409 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Resistant Shaker |
| Instrument Type | Air-Jacketed Constant-Temperature Orbital Shaker |
| Timer Range | 0–99 h 59 min or Continuous Operation |
| Oscillation Speed | 30–300 rpm |
| Orbit Diameter | 19 mm |
| Temperature Range | 4–60 °C |
| Number of Platforms | 1 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | E1-ClipTip Electronic Single-Channel Pipette |
| Volume Range | 0.5–1250 µL |
| Tip Ejection | Motorized ClipTip ejection |
| Operation | Thumb-free finger-actuated pipetting |
| Tip Compatibility | Thermo Scientific ClipTip tips (including E1-ClipTip 12.5 and 384-well formats) |
| Calibration | Liquid-specific calibration supported |
| Memory | 20 programmable protocols |
| Power | Rechargeable Li-ion battery |
| Warranty | 2 years |
| Compliance | Designed for GLP/GMP environments with audit-ready calibration tracking |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Expert CTS |
| Measurement Parameters | Single-parameter (Conductivity, TDS, Salinity, Temperature) |
| Form Factor | Pen-style portable meter |
| Conductivity Range | 0.00 – 20.00 mS/cm |
| TDS Range | 0.00 – 20.00 ppt |
| Resistivity Range | 0 – 50 MΩ·cm |
| Salinity Range | 0.0 – 10.0 ppt |
| Temperature Range | 0.0 – 50.0 °C |
| Accuracy | ±2% full scale ±1 LSD |
| Resolution | 10 µS/cm below 2.00 mS/cm |
| Auto-Calibration Points | 84 µS/cm, 1413 µS/cm, 12.88 mS/cm |
| TDS Conversion Factor | Adjustable (0.40–1.00) |
| Temp Compensation | Automatic (ATC), 0–50.0 °C |
| Display | Dual-line 4-digit LCD with status icons |
| Power | 4 × A76 (LR44) batteries |
| Auto-Off | 8.5 min inactivity |
| IP Rating | IP67 |
| Dimensions | 170 × 45 × 30 mm (L×W×H) |
| Operating Temperature | 5–45 °C |
| Battery Life Indicator | Yes |
| Calibration Status Indicator | Yes |
| Stand & Sample Cup | Integrated protective cap |
| Lanyard | Included |
| Floatation | Buoyant design |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Pen-Style pH Meter |
| Model | EXPERTPH |
| Measurement Parameters | pH and Temperature (°C/°F) |
| pH Range | 0.0–14.0 |
| pH Resolution | 0.1 pH |
| pH Accuracy | ±0.1 pH |
| Temperature Range | 0.0–50.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C ±1 LSD |
| Calibration Points | 1–3 point auto-buffer recognition |
| ATC | Yes |
| Auto-Off | 8.5 min inactivity |
| Power Supply | 4 × A76/LR44 batteries |
| Operating Temperature | 5–45 °C |
| IP Rating | IP67 |
| Dimensions | 170 × 45 × 30 mm (L×W×H) |
| Calibration Standard | NIST-traceable buffers |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Finnpipette Digital Single-Channel Pipette |
| Sterilization | Fully autoclavable (121°C, 20 min) |
| Volume Range | 0.2–1000 µL (standard) |
| Weight | Lightest in class (≤95 g for 100–1000 µL models) |
| Ergonomics | Curved handle, finger rest, low plunger activation force (<1.2 N), large backlit LCD display |
| Compliance | ISO 8655 compliant, CE marked, RoHS compliant |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | Finnpipette F2 |
| Type | Adjustable-Volume Air-Displacement Pipette |
| Sterilization | Fully autoclavable (121 °C, 20 min) and UV-compatible |
| Compliance | ISO 8655-2:2022, ISO 9001:2000, ISO 13485:2003, CE Marked |
| Ergonomics | Low-force plunger activation (<1.5 N for 100–1000 µL), hook-shaped finger rest, integrated volume display with vernier scale |
| Calibration | In-lab calibration supported via included tools and Thermo Fisher’s Pipette Calibration Software (web-based, audit-trail enabled) |
| Volume Range Options | 0.1–10 µL, 0.5–10 µL, 2–20 µL, 10–100 µL, 20–200 µL, 100–1000 µL, 0.5–5 mL, 1–10 mL |
| Display | High-contrast white background with black oversized numerals and integrated vernier scale for ±0.1 % volume setting resolution |
| Tip Compatibility | Universal fit for standard conical polypropylene tips (ISO 8655-3 compliant) |
| Maintenance | Field-serviceable with no special tools |
| service intervals recommended per ISO 8655-5 | 2022 guidelines |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Finnpipette F2 Multichannel Pipette |
| Channel Options | 8, 12, and 16 channels |
| Sterilization | Fully autoclavable (121 °C, 20 min) |
| Display | Ergovisio high-contrast LCD (black background, white digits) |
| Volume Adjustment | Independent dual-control volume selector with rotary cap lock |
| Blow-out Function | Enhanced piston-driven blow-out for volumes ≤50 µL |
| Ergonomics | Wide finger rest, low-force pipetting action, optimized weight distribution |
| Compliance | ISO 8655 compliant |
| Calibration | Factory-calibrated per ISO 8655-2 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F3-10 (1–10 µL) |
| Pipette Type | Manual Single-Channel Adjustable-Volume Pipette |
| Volume Range | 1–10 µL |
| Maximum Capacity | 10 µL |
| Accuracy | ±3.5% at 1 µL, ±1.0% at 10 µL |
| Precision (CV) | ≤1.5% at 10 µL |
| Tip Compatibility | Universal Finntip and ISO-standard conical tips |
| Ergonomic Features | Dual-control plunger, color-coded volume display, wide thumb rest, soft-grip polymer housing |
| Blow-out Function | Enhanced positive displacement blow-out for volumes ≤50 µL |
| Compliance | ISO 8655-2:2022, EN ISO 13485 certified manufacturing |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Finnpipette F3 Single-Channel Variable-Volume Pipette |
| Volume Range | Adjustable (model-specific |
| Ergonomic Design | Dual-control volume adjustment, isolated liquid-volume coupling mechanism, integrated Ergovisio display |
| Compliance | Designed for ISO 8655 compliance verification |
| Material | Chemically resistant, autoclavable upper housing and tip ejector |
| Calibration | User-calibratable per ISO 8655-6 |
| Blow-out Function | Enhanced positive displacement blow-out for ≤50 µL ranges |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory ULT Freezer |
| Model | Forma 700 |
| Effective Capacity | 490 L |
| Internal Dimensions (H×W×D) | 1308 × 584 × 643 mm |
| External Dimensions (H×W×D) | 1976 × 846 × 940 mm |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 3300 W |
| Temperature Range | −50 °C to −86 °C |
| Refrigeration System | Dual-stage PEAK II with R404A (primary) and R290/R508 (secondary) |
| Insulation | 127 mm in-situ foamed polyurethane (CFC-free) |
| Door Thickness | 114 mm |
| Compressors | Two hermetic 1 HP Copeland units |
| Certifications | UL 471, UL 3101-1, CE (LVD & EMC) |
| Weight | 274 kg |
| Energy Consumption | 16 kWh/24h (at −80 °C, ambient 23 °C, 50% load) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Forma 88000 |
| Effective Capacity | 421 L |
| Interior Dimensions (H×W×D) | 1981 × 686 × 955 mm |
| Exterior Dimensions (H×W×D) | 1301.1 × 451.6 × 718.6 mm |
| Power Supply | 230 V / 50 Hz |
| Rated Power Consumption | 3300 W |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 902 |
| Configuration | Upright |
| Net Capacity | 368 L |
| Interior Dimensions (W×H×D) | 584 × 1308 × 490 mm |
| Exterior Dimensions (W×H×D) | 846 × 1976 × 787 mm |
| Power Supply | 220–240 V AC, 50/60 Hz |
| Rated Power Consumption | 16 kW·h/24h |
| Compressor | Dual 1.25 HP hermetic industrial-grade compressors |
| Insulation | 127 mm in-situ foamed polyurethane (CFC-/HCFC-free) |
| Door Seal | Triple-point magnetic gasket |
| Temperature Range | –50 °C to –86 °C |
| Certifications | UL 471 & UL 3101-1, CE (LVD & EMC), FDA CFG, SFDA (now NMPA) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Models | 7401, 7403, 7405, 7407 |
| Quotation | Upon Request |
| Capacity (L) | 90 / 200 / 340 / 552 |
| Static Evaporation Rate (L/day) | 3 / 5 / 8 / 10 |
| 2 mL Vial Capacity | 6,318 / 13,000 / 24,000 / 38,500 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestically Produced |
| Model | Forma Steri-Cycle CO₂ Incubator (China-Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Forma Steri-Cycle Series CO₂ Incubator |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported (Manufactured Outside China) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | 1–5 ppb |
| Microbial Count | < 1 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| RNase | ≤ 0.003 ng/mL |
| DNase | ≤ 0.4 pg/µL |
| UV Wavelengths | 185 nm & 254 nm |
| Flow Rate | ≤ 2 L/min (up to 1.2 L/min at point-of-use arm) |
| Dimensions (W×D×H) | 372 × 330 × 615 mm (main unit) |
| Desktop xCAD arm | 260 × 530 × 725 mm |
| Wall-mounted xCAD arm | 260 × 530 × 655 mm |
| Power Consumption | 0.1 kW |
| Inlet Requirements | RO/DI/distilled water, conductivity < 2 µS/cm (xCAD-specific), TOC ≤ 50 ppb, pressure 0.1–6 bar, temp. 2–35 °C |
| Compliance | ASTM D1193, ISO 3696, CLSI CLRW, USP <645>, GLP/GMP-ready with audit trail and password protection |
| Interface | RS-232 with configurable logging interval |
| Data Storage | Error log history for up to 4 weeks |
| Certifications | IQ/OQ documentation available (E5013318 for xCAD series) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | Helios 5 Laser PFIB |
| Integrated Beams | SEM + Plasma FIB (Xe⁺) + Femtosecond Laser (1030 nm / 515 nm) |
| Laser Pulse Width | <280 fs (1ω), <300 fs (2ω) |
| Laser Repetition Rate | 1 kHz – 1 MHz |
| Laser Spot Size | 15 µm |
| Maximum 3D Volume | 2000 × 2000 × 1000 µm³ |
| Plasma FIB Beam Current | ~1 mA (equivalent), Cutting Current: 74 µA |
| Beam Co-location Accuracy | <250 nm at WD = 4 mm |
| Laser Safety Class | Class 1 Enclosed System |
| Software | Integrated Laser Control, Automated 3D Serial Sectioning Workflow, EBSD-Coupled 3D Reconstruction Module, Scriptable Laser Programming Interface |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | HERAcell 150i |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Control | >99.5% RH (non-condensing) |
| Chamber Capacity | 150 L |
| Sterilization Method | ContraCon 90 °C moist-heat |
| CO₂ Sensing Options | Thermal Conductivity (TC) or Dual-Beam Infrared (IR) |
| Optional O₂ Control Range | 1–21% or 5–90% |
| Interior Material | Electropolished stainless steel (optional 100% pure copper) |
| Door Configuration | Triple-pane tempered glass inner doors (3-door configuration for 150 L) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Models | HERAcell 150i, HERAcell 240i |
| Chamber Material Options | Stainless Steel or 100% Pure Copper |
| ContraCon Sterilization | 90°C moist-heat, 25-hour cycle (validated at 90°C/9 K·h⁻¹) |
| Temperature Range | Ambient +3°C to 55°C |
| Temp Uniformity | ±0.5 K spatially, ±0.1 K over time |
| CO₂ Control Options | Thermal Conductivity (TC) or Dual-Beam Infrared (IR) sensor |
| Optional O₂ Control Ranges | 1–21% or 5–90% |
| Humidity System | Water-free, heated base with angled reservoir (5× faster recovery vs. conventional water pan) |
| Internal Door Configuration | 3-panel (150i) or 6-panel tempered glass |
| Shelving | Full-width (423×465 mm / 560×500 mm), max 10/12 shelves |
| Load Capacity | 10 kg/shelf (full), 5 kg/shelf (half) |
| Sterilization Efficacy | Validated against bacteria, fungi, USP <23> spores, and mycoplasma |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Heracell VIOS 160i / Steri-cycle i160 |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.2 °C |
| Humidity Range & Accuracy | 20–95 % RH |
| Chamber Capacity | 165 L |
| Sterilization Method | 180 °C Dry-Heat |
| Air Filtration | ISO Class 5 HEPA |
| CO₂ Control | IR-based, with iCAN intelligent logging system |
| Cell Compartmentalization | Cell Locker™ modular chamber system |
| Airflow Technology | THRIVE™ rapid-recovery laminar airflow |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Models | 50145502 / 51030287 / 51030478 / 50145515 |
| Price Range | USD $13,500 – $67,500 (based on configuration and regional pricing) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HERAcell VIOS 160i |
| Capacity | 165 L |
| Temperature Range & Accuracy | +3 °C above ambient to 55 °C |
| Temperature Uniformity | < ±0.3 °C |
| Humidity Control | >93% RH at 37 °C |
| CO₂ Sensing | MEMS-based IR180Si infrared sensor or TC180 thermal conductivity sensor |
| O₂ Control Range (optional) | 1–21% (hypoxic) or 5–90% (hyperoxic) |
| Sterilization | Automated 180 °C dry-heat Steri-Run™ cycle |
| Interior Material | 100% electrolytic copper or stainless steel |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Control Range & Accuracy | 1–20% (±0.1% typical deviation) |
| Capacity | 255 L (9.0 cu ft) |
| Chamber Material | Electropolished Stainless Steel or Copper-coated Stainless Steel |
| Humidity Control | Direct-heated, covered integrated water reservoir with rH compensation |
| Sterilization | Validated 180°C dry-heat cycle (12-log microbial reduction) |
| Air Filtration | ISO 5-class HEPA filter, full-chamber air exchange every 60 seconds |
| Recovery Time | All parameters restored within ≤10 min after door opening |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Heraeus BK6160 Low-Temperature |
| Internal Volume | 166 L |
| Temperature Range | 0–50 °C |
| Temperature Uniformity | ±0.8 °C |
| Temperature Stability | ±0.1 °C |
| Air Circulation Rate (with optional fan) | 150 L/h |
| Relative Humidity | >75% at 5 °C, >90% at 37 °C |
| Shelving | 2 standard / up to 7 |
| External Dimensions (W×D×H) | 744 × 920 × 725 mm |
| Internal Dimensions (W×D×H) | 607 × 470 × 585 mm |
| Refrigerant | R134a, 220 g |
| Illumination | 4000 lux (4 lamps, 70 W total) |
| Power Supply | 230 V, 50/60 Hz |
| Weight (with lighting / without) | 120 kg / 100 kg |
| Controller Options | Kelvitron K / KP / KL microprocessor-based units |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Heraeus BK800 Low-Temperature |
| Internal Volume | 220 L |
| Temperature Range | 3–40 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Deviation | ±1 °C |
| Standard/Maximum Shelves | 3 / 14 |
| External Dimensions (W×H×D) | 560 × 1480 × 570 mm |
| Internal Dimensions (W×H×D) | 467 × 1260 × 435 mm |
| Refrigerant | R600a, 20 g |
| Cooling Time (25 °C → 5 °C) | 56 min |
| Timer Range | 1–9999 min |
| Power Supply | 230 V, 50 Hz |
| Net Weight | 52 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Heraeus Pico 17/21 / Fresco 17/21 |
| Centrifuge Type | Benchtop Microcentrifuge |
| Max Speed | 30,000 rpm |
| Max RCF | 21,000 × g |
| Max Capacity | 24 × 2 mL |
| Acceleration/Deceleration Time | 12 s / 12 s |
| Dimensions (W×D×H) | 310 × 436 × 568 mm |
| Rotor Compatibility | Fixed-angle rotors for 0.2–2.0 mL tubes, including PCR strips, hematocrit capillaries, and filter-based spin columns |
| Safety Certification | CAMR-validated ClickSeal™ biocontainment rotors |
| Cooling Type | Refrigerated (Fresco) and Ventilated (Pico) variants |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Heraguard ECO |
| Type | Vertical Laminar Flow Clean Bench |
| Certification | CE (2006/95/EC, 2004/108/EC, 2011/65/EC, 2006/121/EC) |
| Safety Standard | EN 61010-1:2011, EN 61326:2006 |
| Pre-filter | EN779 Class G3 |
| Air Velocity | 0.15–0.25 m/s (Stage 1), 0.32–0.45 m/s (Stage 2) |
| Illumination | >1000 lx |
| Noise Level | <55 dB(A) (Stage 1), <60 dB(A) (Stage 2) |
| Power Consumption | 270 W (ECO 0.9–1.5), 550 W (ECO 1.8 & ECO 1.8/95) |
| Work Surface Load Capacity | 30 kg |
| Net Weight | 90–220 kg |
| External Dimensions (W×H×D, mm) | 1000×1170×810 to 1900×1475×1010 |
| Work Area Dimensions (W×H×D, mm) | 920×645×585 to 1820×950×785 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Heratherm Advanced |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Equipment |
| Model | Heratherm Advanced Series |
| Convection Types | Natural Convection (OGH) / Forced Convection (OMH) |
| Temperature Range | +50 °C to 330 °C |
| Temperature Uniformity (at 150 °C) | ±1.3 °C to ±2.5 °C |
| Temperature Stability (at 150 °C) | ±0.2 °C to ±0.3 °C |
| Chamber Volume | 61–170 L |
| Power Consumption (150 °C, natural convection, 60 L) | 170 W/h |
| Power Consumption (150 °C, forced convection, 60 L) | 259 W/h |
| Programmable Controller | Up to 10 programs × 10 steps |
| Fan Speed Control | Electronically adjustable |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Heratherm Advanced Safety |
| Pricing | Available Upon Request |