| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Verios XHR |
| Instrument Type | Floor-standing / Conventional High-Performance SEM |
| Electron Source | Cold Field Emission Gun (CFEG) |
| Accelerating Voltage Range | 1–30 kV |
| Secondary Electron Resolution | <0.7 nm at 1 kV, <0.4 nm at 30 kV (as specified in Thermo Fisher technical documentation) |
| Backscattered Electron Resolution | <1.5 nm at 30 kV |
| Sample Chamber Dimensions | Ø340 mm × H280 mm |
| Maximum Sample Size | 200 mm wafer or 100 mm × 100 mm × 50 mm bulk specimen |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Veriti 96-Well Thermal Cycler |
| Instrument Type | Gradient PCR System |
| Sample Throughput | 96-well aluminum block (0.2 mL format) |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Block Uniformity | ±0.5 °C (measured at 95 °C, 20 s after ramp completion) |
| Gradient Range | 35–99.9 °C |
| Maximum Ramp Rate | 3.9 °C/s |
| Display | 11.65 cm (4.6 in) VGA color touchscreen |
| Dimensions (W × D × H) | 24.5 × 48.5 × 23.7 cm |
| Weight | 11.4 kg |
| Onboard Memory | 800 protocols |
| Warranty | 2 years |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | VFC-PM10 |
| Typical Configuration | PM₁₀ Inhalable Particulate Sampler |
| Flow Rate | 40 ACFM (1.13 m³/min) |
| Flow Accuracy | < ±1% deviation over 24 h |
| Motor | 1.0 HP, 7 A, 840 W |
| Power Supply | 110 V AC, single-phase, 60 Hz (optional configurations available) |
| Weight | 62 kg (total system) |
| Dimensions | Cabinet: 129 cm H × 56 cm W × 56 cm D (22 kg) |
| PM₁₀ Cyclone | 81 cm H × 81 cm W × 63.5 cm D (25 kg) |
| VFC Fan & Filter Holder Assembly | 71 cm H × 53 cm W × 48 cm D (12 kg) |
| Flow Control Principle | Critical-flow Venturi with aerodynamic energy recovery |
| Compliance | U.S. EPA Reference Method RFPS-1287-063 for PM₁₀ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ViiA™ 7 Real-Time PCR System |
| Instrument Type | Real-Time Quantitative PCR (qPCR) System |
| Throughput | 384-well format (with TaqMan® Array microfluidic cards) |
| Thermal Ramp Rate | Up to 5.5 °C/sec (typical, per manufacturer specifications) |
| Temperature Uniformity | ±0.25 °C across block (per ISO/IEC 17025-validated performance data) |
| Temperature Accuracy | ±0.25 °C at 95 °C (traceable to NIST standards) |
| Optical Channels | 6 independently configurable excitation/emission filter sets |
| Detection Sensitivity | Reliable detection of ≤1.5-fold copy number differences in single-plex assays |
| Software Compliance | Optional 21 CFR Part 11-compliant SAE module available |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | VT550 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 2 – 10⁷ mPa·s |
| Speed Range | 0.5 – 800 rpm |
| Torque Range | 0.1 – 50 mN·m (up to 400 rpm), 0.1 – 20 mN·m (up to 800 rpm) |
| Temperature Range | −40 °C to +350 °C (dependent on optional temperature control unit) |
| Compliance Standards | ISO 2555, ISO 3219, DIN 53018, DIN 53019 |
| Control Mode | Preset Programs (10 built-in), Controlled Deformation (CD) mode for yield stress determination |
| Software Integration | RheoWin (HAAKE proprietary software) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | XSeries II ICP-MS (Refurbished) |
| Mass Range | 2–260 amu |
| Sensitivity (Li-7) | 50 Mcps/ppm |
| Sensitivity (Y-89) | 60 Mcps/ppm (XSeries II standard configuration) |
| Sensitivity (Tl-205) | 80 Mcps/ppm |
| Detection Limit (Be-9) | 0.5 ppt |
| Detection Limit (In-115, Bi-209) | 0.1 ppt |
| Oxide Ratio (CeO+/Ce+) | ≤1.5% |
| Doubly Charged Ion Ratio (Ce2+/Ce+) | ≤3.0% |
| Isotopic Ratio Precision (107Ag/109Ag) | RSD ≤0.1% |
| Abundance Sensitivity (low-mass) | 5 × 10⁻⁷ |
| Abundance Sensitivity (high-mass) | 1 × 10⁻⁷ |
| Collision Cell | ORS3™ (He-only mode) |
| High Matrix Tolerance | Up to 3% total dissolved solids (TDS) via HMI technology |
| Software Platform | MassHunter Workstation (QA/QC, audit trail, automated method execution) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported (Netherlands/USA manufacturing site) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Talos F200C TEM |
| Accelerating Voltage Range | 20–200 kV |
| Detector | Integrated 1600 × 1600 CMOS Direct Detection Camera |
| Lens Configuration | Constant-Power C-Twin Objective Lens |
| Optional Stage | Piezo-Driven High-Stability Specimen Stage |
| Compliance | Designed for GLP/GMP-compliant labs |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 1029 |
| Internal Volume | 77 L |
| Operating Temperature Range | Ambient +4°C to 70°C (fixed at 35°C option available) |
| Temperature Uniformity at 37°C | ±0.4°C |
| Temperature Accuracy | ±0.3°C |
| Anaerobic Gas Requirement | High-purity N₂/H₂/CO₂ (e.g., 85/10/5 or 90/5–7/5 vol%) |
| O₂ Residual Level | <10 ppm |
| Catalyst System | Palladium-based with activated carbon H₂S scavenger |
| Gas Consumption Reduction | ~50% vs. conventional systems |
| Work Area Dimensions (W×H×D) | 445×559×305 mm |
| External Dimensions (W×H×D) | 1539×762×787 mm |
| Glove Port | Elliptical, full-access design |
| Viewing Panel | Flexible anti-fog acrylic (optional rigid polycarbonate) |
| Shelf Configuration | Two adjustable stainless-steel shelves in work area |
| Power Input | 230 V / 50 Hz |
| Compatible Vacuum Pump | Recommended model 901025 |
| Optional Enclosure | Thermo Scientific 1016 Outer Cabinet (1092×762×787 mm) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Certification | NSF/ANSI 49, UL Listed, EN 1822 H14 HEPA |
| Model | MSC-1356 / MSC-1358 |
| Airflow | 530 m³/h (330 CFM) / 840 m³/h (490 CFM) |
| Work Area Surface | 0.56 m² / 0.84 m² |
| Front Window Opening | 250 mm (max 535 mm) |
| Internal Dimensions (W×H×D) | 780×1200×495 mm / 780×1800×495 mm |
| External Dimensions (W×H×D) | 1520×1300×795 mm / 1520×1900×795 mm |
| Weight (net) | ~530 kg / ~750 kg |
| Filtration Efficiency | ≥99.999% at 0.3 µm |
| Noise Level | 63 dB(A) / 65 dB(A) |
| Illumination | >65 fc |
| Power Input | 230 V, 50/60 Hz |
| Protection Class | IP20 |
| Electrical Rating | 0.2 kW / 0.4 kW |
| UV Lamp Timer | 1–24 h programmable |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA (assembled in China under strict quality control) |
| Cabinet Class | Class II, Type A2 |
| Compliance | YY 0569-2005 (China NMPA-regulated Class III medical device), NSF/ANSI 49-2022 compliant |
| Airflow System | Dual independent DC motor-driven blowers with SmartFlow™ real-time air velocity balancing |
| Inflow Velocity | ≥0.5 m/s (adjustable and auto-compensated) |
| Downflow Velocity | ≥0.25 m/s (HEPA-filtered) |
| Filtration | Dual HEPA filters (≥99.99% @ 0.3 µm) — supply and exhaust |
| Noise Level | ≤65 dB(A) |
| Power Requirement | 230 V AC, 50/60 Hz |
| Energy Mode | Night-Save mode reduces power consumption by >75% while maintaining ISO Class 5 (Class 100) work area integrity |
| UV Lamp Option | Timer-controlled (30 min – 24 h), germicidal UVC (254 nm) |
| Construction | Monolithic 304 stainless steel interior or modular anti-glare coated interior |
| Sash Opening Options | 3", 4", 5", or 6" vertical sash height |
| Certification | NMPA registered as Class III medical device |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2111AO |
| Instrument Category | Sodium Ion Analyzer |
| Installation Type | Online |
| Measurement Range | 1.0 ppb – 200 ppm Na⁺ |
| Response Time | ≤2 min to 95% of final value |
| Accuracy | ±5% of reading or ±2 ppb (whichever is greater) |
| Operating Temperature | 5–45 °C |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 2117HL |
| Measurement Range | 75–1000 ppm Cl⁻ |
| Principle | Potentiometric measurement using solid-state chloride-selective electrode |
| Reagent-Free Operation | Yes |
| Display | Backlit LCD with graphical interface |
| Calibration Method | DKA (Dual-Point Known Addition) |
| Response Time (t₉₀) | < 2 minutes |
| Maintenance Requirements | No pumps, no reagents, no moving parts |
| Compliance | Designed for continuous industrial process monitoring in accordance with ASTM D4192, ISO 9297, and EPA Method 325B (adapted for on-line chloride detection) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 2117LL |
| Detection Limit | 1.5 ppb Cl⁻ |
| Measurement Principle | Potentiometric Chloride-Selective Electrode (CSE) |
| Calibration | Dynamic 1–3-point calibration with integrated pH adjustment |
| Compliance | Designed for continuous online monitoring in high-purity water systems |
| Application Environment | Semiconductor-grade UPW, boiler feedwater, RO permeate, condensate, seawater-cooled condenser leak detection |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2120XP |
| Detection Limit | 25 ppb Ca²⁺ |
| Measurement Principle | Calcium-Selective Electrode (CSE) with pH-Buffered Sample Conditioning |
| Display | Backlit LCD |
| Calibration Method | Dual-Standard Known Addition (DKA) |
| Optional Channels | pH or Conductivity (second channel) |
| Communication | Digital I/O and Modbus RTU/ASCII support |
| Maintenance Design | No moving parts, no reagent pumps, no consumable dosing systems |
| Compliance | Designed for continuous operation in industrial water treatment environments per ASTM D1066 and ISO 5667-3 guidelines |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 2120XP |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 3131 |
| Pricing | Available Upon Request |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0–20 / 0–100 / 0–200 mg/L KMnO₄ (customizable extended ranges available) |
| Repeatability | ≤ ±3% RSD |
| Accuracy | ±3% of reading |
| Limit of Detection (LOD) | ≤ 0.2 mg/L |
| Resolution | 0.001 mg/L |
| Analysis Time per Sample | < 60 minutes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Thermo Scientific 5900 VOCs |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Continuous Analyzer |
| Detection Range | NMHC 0–5 ppm |
| Accuracy | ≤ ±10% |
| Response Time | ≤ 15 min |
| Compliance | Designed for EN 13526, EPA Method 25A, ISO 11890-2, and US EPA Compendium Method TO-17 (with preconcentration) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 6800 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 6800 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Canada |
| Model | Accela |
| Pressure Rating | Up to 15,000 psi |
| Pump Delay Volume | 65 µL |
| Detector | Accela PDA Detector (LightPipe™ technology) |
| Column Compatibility | Sub-2 µm particles |
| System Age | 2–3 years |
| Warranty | 6 months |
| Compliance | Designed for ASTM D4790, USP <621>, ISO 17025-aligned operation |
| Software Platform | Thermo Scientific Chromeleon CDS v7.x |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AerosolSense & Renvo |
| Instrument Type | Aerosol Pathogen Monitoring System |
| Detection Target | Influenza A/B, SARS-CoV-2, RSV-B |
| Sample Processing Time (Renvo) | ≤30 min |
| Amplification Technology | Oscillating Amplification Reaction (Oscar™) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Thermo Scientific AM16 |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AquaPro Five-Parameter System |
| Instrument Type | Online Monitor |
| Temperature Range | –5 to 95 °C |
| pH Range | 0.00–14.00 pH |
| Dissolved Oxygen Range | 0.00–20.00 ppm (0–50 °C) |
| Conductivity Range | 0–2000 µS/cm |
| Turbidity Range | 0–4000 NTU (–5 to 50 °C) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Models | CY50910, CY50905, CY50915, CY50920 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ChemComb 3500 |
| Configuration | Integrated Multi-Phase Sampling Cartridge |
| Flow Rate | 10 L/min (PM₂.₅/PM₁₀ mode) |
| Diffusion Tube Material | Borosilicate Glass |
| Diffusion Tube Dimensions | Ø47 mm × 38 mm, ~212 hexagonal channels per unit, channel side length ≈ 2 mm, internal surface area ≈ 775 cm² |
| Filter Format | Four-stage 47 mm filter holder (PTFE construction) |
| Inlet Options | Anodized Aluminum or PTFE-coated PM₂.₅ (10 & 16.7 L/min) and PM₁₀ (10 L/min) cyclones |
| Organic Sorbent Stages | Optional PUF and/or XAD-2 resin beds downstream of filters |
| External Diameter (excl. clamps) | 7.49 cm |
| External Diameter (incl. clamps) | 9.68 cm |
| Length (inlet to 1/4″ quick-connect outlet) | 28.27 cm |
| Weight (empty) | 1.23 kg |
| Weight (with two diffusion tubes) | 1.45 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Biosystem (Single-Position, Controller Not Included) / Biosystem 4-Position (Controller Not Included) |
| Stirring Capacity | 20 L (single position) / 5 L per position (4-position) |
| Speed Range | 5–120 rpm |
| Temperature Operating Range | –10 °C to +56 °C (at 100% relative humidity) |
| Controller Requirement | External Biomodul 40B controller (one unit supports up to two Biosystem units) |
| Construction | Seamless stainless-steel housing, CO₂ incubator-compatible design |
| Power Regulation | Independent power adjustment per stir position |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Magnetic Stirrer |
| Model | Cimarec i Micro w/Telemodul |
| Maximum Stirring Volume | 1 L |
| Speed Range | 130–1400 rpm |
| Temperature Control Range | −10 to 120 °C |
| Construction | Seamless Stainless Steel Housing |
| Environmental Operating Range | −10 to 120 °C, up to 95% RH |
| Optional Multi-Unit Control | Up to 8 units via Telemodul interface |
| Temperature Uniformity | High spatial and temporal homogeneity across plate surface |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | Cimarec i Telesystems |
| Stirrer Type | Magnetic Stirrer |
| Max. Stirring Volume | 20 L (total, across all positions) |
| Speed Range | 100–2000 rpm |
| Temperature Control Range | −10 °C to +56 °C |
| Enclosure Rating | IP68 |
| Material | Corrosion-Resistant Stainless Steel |
| Controller Options | Telemodul 20 C (basic) or Telemodul 40 C (with RS232 interface for PC connectivity and data logging) |
| Operating Humidity | Up to 100% RH |
| Individual Position Capacity | Up to 2 L per stir point |
| Configurations Available | 6-, 15-, and 60-point platforms |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Equipment |
| Model | Cimarec Series |
| Price | Upon Request |
| Heating Plate Material | Ceramic or Aluminum (model-dependent) |
| Stirring Speed Range | 60–1200 rpm |
| Temperature Range | 5°C to 540°C (10" models: up to 400°C) |
| Max. Vessel Capacity | 1 L, 4 L, or 6 L (depending on platform size) |
| Max. Load Weight | 6.8 kg, 11.3 kg, or 15.9 kg |
| Power Supply | 220–240 V, 50/60 Hz |
| Panel Dimensions | 10.8 × 10.8 cm, 18.4 × 18.4 cm, or 26.0 × 26.0 cm |
| Overall Dimensions (W × D × H) | 12.7 × 25.4 × 9.1 cm, 20.8 × 33.0 × 9.7 cm, or 28.7 × 41.1 × 10.2 cm |
| Net Weight | 3.2 kg, 5.0 kg, or 6.2 kg |
| Safety Features | HOT TOP surface temperature warning (>50°C), immediate stir bar stop function, StirTrac™ magnetic coupling control |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | CleanMill Broad Ion Beam Milling System |
| Pricing | Request Quote |