TSE Systems
Filter
Showing 1–30 of 53 results
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | ActiMot2 – Light-Beam Frames |
| Application | Automated 3D locomotor and fine-motor activity monitoring in home-cage environments |
| Compatibility | Standard mouse/rat housing cages, CaloCage (indirect calorimetry), PhenoCage (metabolic phenotyping), PhenoMaster笼 systems |
| Calibration | Factory-calibrated |
| Detection Principle | Dual-mode infrared beam interruption (coarse locomotion + fine-motion discrimination) with configurable dead time and spatial zoning |
| Spatial Resolution | Adjustable frame geometry supporting multiple cage footprints (e.g., 20 × 20 cm to 40 × 40 cm) |
| Temporal Resolution | ≥100 Hz beam-sampling rate per channel |
| Sensor Architecture | Non-contact, solid-state IR emitter/detector pairs arranged orthogonally along X, Y, and Z axes |
| Environmental Robustness | EMI-shielded, ambient-light-immune optics |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | ActiMot2 System |
| Application | Automated In-Cage Spontaneous Locomotor Activity Monitoring for Rodents |
| Measurement Principle | Dual-Modality Infrared Beam Break + Optional InfraMot Thermal Motion Sensing |
| Cage Compatibility | Standard Home Cages, CaloCage (Indirect Calorimetry), PhenoCage (Metabolic Phenotyping) |
| Spatial Resolution | Configurable XYZ Beam Grid (X/Y: ≤10 mm spacing |
| Z | 3-layer vertical stratification) |
| Temporal Resolution | 10 ms Beam State Sampling |
| Region Definition | User-Defined Center/Periphery Zones (Open-Field Analog) |
| Motion Classification | Ambulation (Beam Crossings ≥2 Consecutive Beams) vs. Fine Motor Activity (Single-Beam Interruptions with Configurable Refractory Period ≥50 ms) |
| Calibration-Free Operation | Self-Validating Beam Array with Dynamic Baseline Adjustment |
| Obstruction Handling | Persistent Beam Block (e.g., bedding accumulation) Automatically Excluded from Activity Counting |
| Environmental Integration | Compatible with Temperature/Humidity-Controlled Vivaria and ISO 17025-Accredited Behavioral Testing Suites |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | AudioBox by NewBehavior |
| Application | Automated Auditory Operant Conditioning in Group-Housed Mice/Rats |
| Integration | Compatible with IntelliCage platform |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Cell Culture Units |
| Application | In Vitro Air-Liquid Interface (ALI) Inhalation Toxicity Testing |
| Construction | Stainless Steel Exposure Chambers, Borosilicate Glass Mixing/Dilution Modules |
| Aerosol Compatibility | Liquid aerosols, dry powder aerosols, vapors, cigarette smoke |
| Flow Control | Mass flow controllers (MFCs) with real-time monitoring |
| Software | DACO Inhalation Control Software (customized version) |
| Capacity | Up to 48 Transwell® inserts per exposure unit |
| Temperature Control | Integrated heating system for long-term ALI culture maintenance |
| Aerosol Delivery | Dual independent exposure chambers with shared or separate aerosol generation |
| Uniformity | Internal flow distribution plate ensures homogeneous aerosol deposition across insert membranes |
| Compliance | Designed for GLP-compliant in vitro inhalation studies |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Head Nose Only Units |
| Construction | Modular stainless steel or aluminum frame |
| Animal Compatibility | Mice to guinea pigs (customizable for other species) |
| Exposure Configuration | Head-only restraint with nasal inhalation pathway |
| Aerosol Delivery | Integrated aerosol inlet ports with optional conditioning unit |
| Environmental Monitoring | Sensor ports for real-time temperature, humidity, and aerosol concentration monitoring |
| Mobility Option | Castor-mounted mobile base with locking brakes |
| Compliance | Designed per OECD TG 412, ASTM E1709, and ISO 10993-12 guidelines |
| Regulatory Support | Compatible with GLP-compliant data acquisition and audit-trail-enabled software integration |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | InfraMot – Activity System |
| Detection Principle | Passive Infrared (PIR) Thermal Imaging |
| Measurement Type | Total Locomotor and Postural Activity |
| Cage Compatibility | Universal (all standard rodent housing sizes) |
| Installation | Top-mounted or flexible spatial positioning |
| Light Condition Independence | Full spectrum — operates in total darkness |
| Temporal Resolution | Millisecond-level motion event detection |
| Calibration | Zero-calibration required |
| Integration | Modular component of PhenoMaster® and LabMaster® platforms |
| Cleaning | Removable sensor unit for routine decontamination |
| Compliance | Designed for GLP-compliant longitudinal phenotyping studies |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | InfraMot |
| Detection Principle | Passive Infrared (PIR) Thermal Imaging |
| Spatial Resolution | Cage-wide volumetric activity mapping |
| Temporal Resolution | Millisecond-level motion event detection |
| Installation | Top-mounted modular sensor unit compatible with PhenoMaster/LabMaster caging systems |
| Calibration | Factory-calibrated, zero user calibration required |
| Environmental Operation | Full light-independence (operational in total darkness or standard lighting) |
| Cage Compatibility | Universal fit for standard and custom rodent housing dimensions |
| Hygiene Design | Tool-free removable sensor head for autoclave-compatible cleaning |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | IntelliCage Add-On AnimalGate |
| Type | Modular RFID-Based Animal Access Gate for Automated Behavioral Phenotyping |
| Compliance | CE-marked, compatible with GLP-compliant data workflows |
| Software Integration | Fully controlled via IntelliCage Plus v5.0+ (FDA 21 CFR Part 11–ready audit trail, electronic signature support) |
| Optional Hardware | Integrated high-precision load cell (±0.1 g resolution, 500 g max capacity) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | IntelliCage Add-On SocialBox |
| Type | RFID-Based Automated Social Behavior Monitoring Module for Mouse Ethology |
| Compatibility | Designed exclusively for IntelliCage Plus and IntelliCage Pro systems |
| Max Expansion | Up to 4 SocialBoxes per IntelliCage unit (5 total zones) |
| System Scalability | Up to 8 IntelliCage units or 32 SocialBoxes (128 mice) |
| Software Control | IntelliCage Plus v5.0+ with audit-trail-enabled experimental protocol scheduling |
| Regulatory Alignment | Compliant with GLP-compliant data integrity requirements |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Light-Dark Test |
| Configuration Options | Two- or Three-Compartment Chamber (Single- or Dual-Animal Setup) |
| Integration | Compatible with TSE PhenoMaster®, VideoMot2® video tracking, ActiMot2® infrared beam frame, TSE Conditioning Systems & Multi-Conditioning Systems |
| Species | Mice and Rats |
| Regulatory Context | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Motor Function & Performance |
| Type | Integrated Behavioral Phenotyping Platform for Rodent Motor Assessment |
| Application Domain | Preclinical Neuroscience, Neurodegeneration Research, Neuromuscular Pharmacology, Toxicology Screening |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VisioTracker by NewBehavior |
| Pricing | Available Upon Request |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster / LabMaster |
| Cage Type | Modular Indirect Calorimetry & Behavioral Phenotyping System for Small Laboratory Animals |
| Regulatory Compliance | Designed for GLP-compliant metabolic phenotyping studies |
| Software Platform | PhenoMaster/LabMaster v6.x (Windows-based, FDA 21 CFR Part 11–ready audit trail optional) |
| Cage Scalability | Up to 128 cages per controller unit (expandable via networked controllers) |
| Data Export Formats | CSV, HDF5, MATLAB (.mat), SQL-compatible schema |
| Sensor Resolution | Food intake ±0.01 g |
| Urine/Feces Separation | Gravity-based dual-channel collection with load-cell weighing (±0.001 g resolution) |
| RER Calculation | Real-time stoichiometric derivation from VO₂ and VCO₂ (ISO 8573-1 compliant gas analysis calibration protocol supported) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | RotaRod Advanced |
| Animal Capacity | Up to 5 mice or 4 rats (configurable) |
| Speed Range | 1–60 rpm (constant, accelerating, or decelerating) |
| Control | Independent optical beam detection per lane |
| Motor Control | Electronically regulated DC motor |
| Software | Windows-based protocol editor with up to 100-step programmable speed profiles |
| Data Export | CSV/Excel-compatible output |
| Optional Modules | Foot shock unit, elevated drum configuration |
| Reversibility | Programmable bidirectional rotation |
| Compliance | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Snout-Only Units |
| Construction | Stainless Steel with Chemically Resistant Seals |
| Animal Compatibility | Dogs and Larger Non-Rodent Species |
| Exposure Configuration | Ten Parallel Exposure Ports |
| Airflow Architecture | Segregated Inspiratory/Expiratory Pathways |
| Aerosol Delivery | Compatible with Liquid Aerosols, Dry Powder Aerosols, and Vapor Generators |
| Humidification & Mixing | Integrated Aerosol Humidification and Homogenization Unit |
| Port Accessibility | Dual Sampling/Sensor Ports (Top and Bottom) |
| Modular Design | Removable Upper Chamber for Cleaning and Transport |
| Species-Specific Restrainers | Available for Canine and Other Large Animal Models |
| Regulatory Alignment | Designed to Support OECD 412, OECD 413, ASTM E1936, and ISO 10993-12 Test Protocols |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Tail Suspension Monitor |
| Configuration | Computerized, up to 16-channel |
| Regulatory Compliance | Designed for GLP-compliant behavioral phenotyping in preclinical neuroscience research |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Metabolic PhenoCages |
| Application | Automated Metabolic Phenotyping in Mice and Rats |
| Urine/Feces Separation | Dual-compartment funnel with cryo-compatible collection vessels |
| Quantification Method | High-precision load cells (±0.01 g resolution) under chilled collection containers |
| Integration | Fully compatible with PhenoMaster® and LabMaster® modular monitoring platforms |
| Optional Modules | CaloCage™ for indirect calorimetry, food/water intake sensors, XYZ photobeam activity frame |
| Cage Design | Modular, autoclavable components with rapid disassembly for decontamination |
| Sample Preservation | On-board cryogenic separation — urine and feces collected into individually chilled, sealed compartments |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | TSE MotoRater System |
| Application Scope | Quantitative kinematic gait analysis, locomotor behavior phenotyping, neuromuscular function assessment in rats and mice |
| Imaging Configuration | Multi-angle synchronized high-speed video capture (ventral + bilateral views) |
| Tracking Method | Color-based markerless or marker-assisted anatomical point tracking |
| Output Metrics | Joint angle kinetics, stride parameters, inter-limb coordination, trunk/tail kinematics, swim stroke dynamics |
| Compliance | Designed to support GLP-compliant preclinical studies |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster |
| Application | Modular, automated, long-term metabolic and behavioral phenotyping of rodents (mice and rats) |
| Cage Capacity | Up to 64 animals |
| Measurement Principle | Indirect calorimetry (O₂ consumption, CO₂ production, RER, energy expenditure) integrated with multi-sensor behavioral monitoring |
| Compliance | Designed for GLP-compliant studies |
| Software Platform | PhenoMaster Suite (v5.x or later), including experimental protocol scheduling, real-time visualization, raw data export (CSV, HDF5, MATLAB-compatible), and metadata-enriched database archiving |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster_H |
| Configuration | Modular, Multi-Channel (up to 256 channels) |
| Gas Sensing | Zirconia O₂ sensor & NDIR CO₂ sensor |
| Flow Control | Independent high-flow controller per cage |
| Measurement Modes | Standard sequential mode & Real-time continuous mode (1 Hz per cage) |
| Data Output | Binary raw data with user-defined sampling frequency |
| Cage Airflow | Configurable PULL/PUSH mode with laminar wall-guided circulation |
| Activity Monitoring | XYZ optical 3D frame |
| Urine/Feces Collection | TSE-engineered hydrophobic umbrella-shaped internal lining |
| Compliance | Designed for GLP-compliant phenotyping studies |
| Software | PhenoMaster Control & Analysis Suite (FDA 21 CFR Part 11–ready audit trail, experimental protocol scheduling, time-synchronized multi-parameter export) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster_M |
| Application | Long-term, non-invasive metabolic phenotyping of small rodents (mice and rats) |
| Measurement Principle | Indirect calorimetry (O₂ consumption & CO₂ production via zirconia O₂ sensor and NDIR CO₂ sensor) combined with integrated behavioral and physiological monitoring |
| Channel Capacity | Up to 256 independently configurable cages |
| Gas Flow Control | Individual high-flow mass flow controllers per cage (PULL/PUSH selectable) |
| Data Acquisition | Raw binary time-series data (user-configurable sampling interval), full audit trail support |
| Compliance | Designed for GLP-compliant studies |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster-R/M |
| Cage Capacity | Up to 64 rodents (rats or mice) |
| Measurement Principle | Indirect Calorimetry + Behavioral Sensor Fusion |
| Compliance | Designed for GLP-compliant metabolic phenotyping studies |
| Software Platform | PhenoMaster/LabMaster v5.x (FDA 21 CFR Part 11–ready audit trail, role-based access control, raw data export in CSV, HDF5, and MATLAB-compatible formats) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | 5-Hole-Box System |
| Application | Operant Behavioral Testing in Mice and Rats |
| Stimulus Modality | Visual (LED), Auditory (White Noise, Sine Tones) |
| Reward Delivery | Pellet (14/20/45 mg) or Liquid via Solenoid-Actuated Dispensers |
| Detection Method | Infrared Beam Break |
| Programmability | Built-in Protocol Editor (Customizable Trial Logic, Stimulus Timing, Reinforcement Schedules) |
| Compliance | Designed for GLP-aligned behavioral phenotyping workflows |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Active Avoidance / Passive Avoidance |
| Application Scope | Rodent (rat/mouse) behavioral conditioning |
| Stimulus Modalities | Electrical foot shock, pneumatic air puff, auditory tones (up to 20 kHz), visual light cues |
| Detection Method | Adjustable infrared beam break array |
| Software Platform | Windows-based TSE Behavioral Suite with real-time parameter logging and GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Max Concurrent Test Chambers | 4 |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Aerosol Conditioning |
| Type | Aerosol Conditioning Unit for Inhalation Toxicology Studies |
| Construction Materials | Borosilicate Glass, Stainless Steel (316L), Chemically Resistant Polymers (e.g., PTFE, PFA) |
| Flow Rate Control | Precision Mass Flow Controllers (MFCs), Adjustable Air-to-Aerosol Ratio |
| Humidity Control | Saturated Steam or Bubble-Type Humidifier, ±2% RH accuracy |
| Temperature Control | Jacketed Glass Sections with Circulating Water Bath or Heated Stainless Steel Tubing (Range: 15–40 °C) |
| Electrostatic Neutralization | Polonium-210 or Soft X-ray Discharger (Compliant with ISO 15012-1) |
| Particle Pre-Separation | Impactor Stages & Cyclonic Separators (D50 adjustable from 0.5 µm to 10 µm) |
| Software Integration | DACO Inhalation Exposure Software (v5.2+), Supports ASTM E1777, OECD 412, and EPA OPPTS 870.3465 protocols |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | CaloSys |
| Measurement Principle | Open-circuit indirect calorimetry |
| Animal Capacity | Single- or multi-cage configurations (CaloCages) |
| Gas Sampling Interval | ~40 s per cage |
| Supported Modalities | Voluntary wheel running (sealed enclosure, programmable speed profiles) |
| Data Output | VO₂, VCO₂, RER, EE (kcal/h or kJ/h), locomotor activity |
| Software | CaloSys control and analysis suite with real-time visualization, timestamped interval-based file updates, tabular + graphical data export |
| Compliance | Designed for GLP-compliant metabolic phenotyping studies |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | CaloTreadmill Series |
| Speed Range | 0.07–2.0 m/s |
| Incline Adjustment | –10° to +25° |
| Max. Lanes | 8 independent motorized belts |
| Stimulus Output | Programmable foot shock (constant current, adjustable intensity/duration) |
| Data Export | CSV/Excel-compatible ASCII format |
| Software Platform | Windows-based TSE Treadmill Control Suite v5.x |
| Compliance | Designed for GLP-compliant rodent exercise protocols |
| Thermal Configuration | Integrated Peltier-based cooling/heating modules (CaloTreadmill variant) |
| Animal Detection | Adjustable infrared beam sensors per lane |
| Timing | Individual lane-specific start/stop timers with microsecond resolution |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | SMG Series |
| Application | Automated Cigarette Smoke Generation for Inhalation Toxicology and In Vitro Exposure Studies |
| Compliance | ISO 3308, ISO 4387, ASTM D1557, OECD TG 412 |
| Sample Capacity | Up to 250 cigarettes (bulk magazine), 10-cigarrette rotating wheel (standard) |
| Puff Profile Options | Gaussian, Ramp, Rectangular |
| Software Control | SMG Control Software with Real-Time Monitoring, Parameter Logging, and Audit-Trail-Capable Data Export |
| Chamber Integration | Compatible with TSE’s in vitro exposure chambers (e.g., 10-port cell culture exposure system), side-stream smoke collection port configurable or removable |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PermaSensor DF-BW Series |
| Sensor Capacity | Up to 6 per cage |
| Measurement Types | Liquid intake, solid food consumption, body weight |
| Sensor Flexibility | Interchangeable assignment (drink/food/weight) |
| Cage Compatibility | Standard IVC and static cages (no modification required) |
| Integration | Compatible with TSE PhenoMaster® metabolic monitoring platforms |
| Data Resolution | Sub-gram weight resolution |
| Temporal Resolution | Continuous logging at user-defined intervals (e.g., 1–60 s) |
| Environmental Robustness | Designed for long-term operation in controlled vivarium conditions |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Dust Aerosols |
| Type | Inhalation Exposure Chamber for Dry Powder Aerosol Generation |
| Application Domain | Preclinical Inhalation Toxicology, Respiratory Pharmacology, and Particle Deposition Studies |