| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Range | 1 ppm – 100% (10 µg – 100 mg H₂O) |
| Accuracy | ≤0.3% RSD (n=10, ≥1 mg H₂O) |
| Minimum Dispensing Volume | 1/2000 of Titrator Volume |
| Electrolysis Current | 430 mA |
| Average Titration Speed | 2.2 mg H₂O/min |
| Display | 5.7-inch Color LCD |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Dimensions (Analyzer) | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~5 kg |
| VA-210 Vaporizer Temp. Range | 70–199 °C |
| Carrier Gas | N₂, 0.1–0.5 L/min |
| Power | AC 100 V, 160 VA |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 10 µg – 100 mg H₂O |
| Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Electrolysis Current | 430 mA |
| Precision | CV ≤ 0.3% for samples ≥ 1 mg H₂O (n = 10) |
| Display | 5.7-inch color LCD |
| Sample Capacity | Up to 33 samples with optional auto-sampler |
| Data Storage | 20 user-defined methods, each supporting 50 sub-files |
| Interface | RS-232C (optional), USB port for data export, balance input, internal/external communication ports |
| Power Supply | AC 100–120 V or 230–240 V, 50/60 Hz |
| Power Consumption | 80 VA (100–120 V), 310 VA (230–240 V) |
| Dimensions (Analyzer) | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~5 kg |
| Stirrer Dimensions | 120 × 180 × 148 mm |
| Weight | ~1 kg |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Method Type | Single-Channel |
| Measurement Range | 10 µg – 100 mg H₂O |
| Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Electrolysis Current | 430 mA |
| Precision | CV ≤ 0.3% for samples ≥ 1 mg H₂O (n = 10) |
| Data Storage | 20 individual files + 50 composite files |
| Display | 5.7-inch color LCD |
| Interfaces | RS-232C (optional), USB host (2 ports), internal balance input (auto-weighing), dedicated USB storage port |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Power Consumption | 80 VA (100–120 V), 310 VA (230–240 V) |
| Dimensions (Main Unit) | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~5 kg |
| Stirrer Dimensions | 120 × 180 × 148 mm |
| Weight | ~1 kg |
| Compliance | GLP/GMP-supporting architecture, audit-ready data handling |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Detection Range | 10 µg – 100 mg H₂O |
| Accuracy | CV ≤ 0.3% for samples ≥ 1 mg H₂O (n = 10) |
| Electrolysis Current | 430 mA |
| Average Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Display | 5.7-inch color LCD |
| Data Storage | 20 user-defined methods × 50 sub-files each |
| Interface | RS-232C (optional), USB storage port, analytical balance input |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Host Dimensions & Weight | 220 × 350 × 360 mm, ~5 kg |
| Stirrer Dimensions & Weight | 120 × 180 × 148 mm, ~1 kg |
| VA-200 Sample Heater | Temp. Range 70–300 °C, N₂ carrier gas flow 0.1–0.5 L/min, max. sample mass 10 g, weight ~5.5 kg |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Range | 10 µg – 100 mg H₂O |
| Accuracy | ≤0.3% RSD (≥1 mg H₂O, n=10) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Electrolysis Current | 430 mA |
| Average Titration Speed | 2.2 mg H₂O/min |
| Display | 5.7-inch color LCD |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Dimensions (Analyzer) | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~5 kg |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CA-31 |
| Titration Method | Fully Automatic Coulometric Titration |
| Measurement Principle | Karl Fischer Coulometric (Electrolytic) Method |
| Water Content Range | 10 µg to 999.9999 mg H₂O |
| Resolution | ±0.1 µA |
| Accuracy | ≤ ±0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Control Precision | 0.1 µL |
| Display | 5.7-inch Color TFT Touchscreen |
| Interface | USB (for balance, PC, and storage device) |
| Power Supply | AC 100/120/220/240 V, 50/60 Hz, 600 VA |
| Dimensions (main unit, excl. cell & battery) | Approx. 220 × 350 × 360 mm (W×D×H) |
| Weight (main unit) | ~3.8 kg |
| Weight (with battery pack) | ~6.6 kg |
| Compliance | FDA 21 CFR Part 11–ready software support (via optional data collection software), GLP/GMP traceability enabled |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CA-310 |
| Electrolysis Current | 400 mA |
| Titration Speed | 2.1 mg H₂O/min |
| Measurement Range | 10 µg – 100 mg H₂O |
| Detection Limit | 0.1 µg H₂O |
| Accuracy | ±3 µg (for 10 µg – 1 mg H₂O) |
| Precision | RSD ≤ 0.3% (for ≥1 mg H₂O) |
| Printer | 21-character dot-matrix thermal printer (58 mm paper width) |
| Channel Configuration | Single or dual-channel (Coulometric/Coulometric, Coulometric/Volumetric single-cell, Coulometric/Volumetric dual-cell) |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CA-310 (Coulometric & Volumetric Modes) |
| Display | 8.4-inch color touchscreen (Chinese UI) |
| Electrode Options | Membrane-free or membrane-type generator electrode |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CA200C |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Measurement Range | 10 µg – 100 mg H₂O |
| Accuracy | ≤ 0.3% RSD (for samples ≥ 1 mg H₂O) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Electrolysis Current | 430 mA |
| Precision | CV ≤ 0.3% (n = 10, ≥1 mg H₂O) |
| Display | 5.7-inch color LCD |
| Data Storage | 20 single files + 50 composite files |
| Interfaces | Dual USB ports, RS-232C (optional), balance auto-input support |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Power Consumption | 80 VA (100–120 V), 310 VA (230–240 V) |
| Dimensions (main unit) | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~5 kg |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CVS-121 |
| Titration Method | Fully Automated Coulometric Karl Fischer Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Current Resolution | ±0.1 µA |
| Water Content Range | 0.5 µg to 999.9999 mg |
| Measurement Accuracy | <0.3% RSD |
| Minimum Dispense Volume | 0 µL |
| Titration Control Precision | N/A |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CVS-122 |
| Titration Method | Fully Automatic Coulometric Karl Fischer Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | ±0.1 μA |
| Water Content Range | 0.5 μg to 999.9999 mg |
| Accuracy | <0.3% RSD |
| Minimum Dispense Volume | 0 μL |
| Titration Control Precision | 0 (coulometric, current-controlled, no burette dispensing) |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CVS-210 |
| Titration Method | Fully Automated Coulometric Karl Fischer Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | ±0.1 μA |
| Water Content Range | 0.5 μg to 999.9999 mg |
| Accuracy | <0.3% RSD |
| Minimum Dispensing Volume | 0 μL |
| Titration Control Precision | 0 (coulometric, current-controlled, no reagent dispensing) |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CVS-230 |
| Titration Method | Fully Automated Coulometric Karl Fischer Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | ±0.1 μA |
| Water Content Range | 0.5 μg to 999.9999 mg |
| Accuracy | <0.3% RSD |
| Minimum Dispensing Volume | 0 μL |
| Titration Control Precision | 0 (coulometric, current-controlled, no reagent dispensing) |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automatic |
| Measurement Resolution | ±0.1 µA |
| Water Content Range | 0.5 µg to 999.9999 mg |
| Accuracy | <0.3% RSD |
| Minimum Dispensing Volume | 0 µL |
| Titration Control Precision | 0 (coulometric, reagent-free generation) |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CVS-300 |
| Titration Method | Fully Automated Coulometric Karl Fischer Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Current Resolution | ±0.1 µA |
| Water Content Range | 5 µg to 999.9999 mg |
| Measurement Accuracy | <0.3% RSD |
| Minimum Dispense Volume | 0 µL |
| Titration Control Precision | N/A |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | GT-200 |
| Measurement Range | 0–14 pH, −2000 to +2000 mV, 0–20 µA |
| Titrant Dispensing Accuracy | ±0.01 mL (20 mL burette) |
| Resolution | 0.002 mL |
| Titration Resolution | 1/10000 |
| Display | 5.7″ color LCD |
| Operating Temperature | 5–40 °C |
| Humidity | ≤85% RH (non-condensing) |
| Power Supply | 100–240 V AC, 100 VA |
| Dimensions (main unit) | 175 × 408 × 176 mm (W×D×H) |
| Weight | 4 kg |
| GLP Compliance | Full audit trail for calibration, electrode validation, titrant standardization, and user access logs |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | GT-310 |
| Display | 8.4-inch color touchscreen |
| Channels | up to 4 simultaneous potentiometric and/or Karl Fischer titration channels |
| Modularity | supports solvent dispensers, autosamplers, analytical balances, and printers |
| Compliance | Designed for GLP/GMP environments |
| Pricing | Available upon request |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | GT-310 |
| Instrument Type | General-purpose Potentiometric Titrator |
| pH Range | 0–14 |
| mV Range | –2000 to +2000 mV |
| Meter Accuracy | ±0.2% of full scale |
| pH Resolution | 0.001 pH unit |
| Titration Endpoint Precision | ±0.3 mV |
| Maximum Simultaneous Modules | 4 titration units (potentiometric and/or Karl Fischer) |
| Endpoint Detection Modes | First Derivative (Inflection Point), Fixed Potential, Pre-/Post-Intersection, V-Crosspoint, and Second Derivative |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | KF-200 |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Water Content Range | 0.1 mg – 999 mg H₂O |
| Titration Accuracy | ±0.02 mL (with 10 mL syringe) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Display | 5.7-inch color LCD |
| Burette Capacity | 10 mL (optional 25 mL) |
| Dispensing Speed | 1 mL / 1.5 sec |
| Data Storage | 20 single files + 50 composite files |
| Interface | RS-232C (optional), USB host (2 ports), balance auto-input, internal/external I/O |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Dimensions (main unit) | 330 × 320 × 148 mm |
| Weight (main unit) | ~5 kg |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KF-31 |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µA |
| Water Content Range | 0.01 mg – 999.999 mg H₂O (equivalent to ~10 µg – 999.999 mg absolute water) |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Volume | 1/2000 of burette capacity |
| Titration Control Precision | 0.1 µL |
| Burette Capacity | 5 mL |
| Electrode Detection | Continuous Current Polarization (Dual-Platinum Electrode System) |
| Display | 5.7-inch Full-Color LCD Touchscreen |
| Data Storage | Internal memory for ≥1 titration factor calibration, ≥3 user-defined methods |
| Connectivity | USB × 2 (PC, keyboard, USB flash drive, auto fluid handling), RS-232C × 2 (printer, analytical balance, vaporizer units) |
| Compatible Vaporizers | VA-200, VA-300, VA-230, VG-200 (all with stepwise temperature control) |
| Operating Environment | 15–40 °C, ≤85% RH (non-condensing) |
| Power Supply | AC 100/120/220/240 V, 50/60 Hz, 60 VA |
| Dimensions | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~3.8 kg (excluding titration cell and power adapter) |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | MCP-HT800 |
| Portability | Portable |
| Impedance Measurement Range | 10⁴ Ω to 10²⁰ Ω |
| Accuracy | ±2% (10⁴–10⁹ Ω), ±3% (up to 10²⁰ Ω) |
| Test Voltage Range | 1 V to 10 V (programmable, DC or low-frequency AC) |
| Compliance | CE, JIS C 1302, IEC 60068-2 (environmental robustness for lab/field use) |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | MCP-T370 |
| Portability | Portable |
| Measurement Principle | Four-terminal (Kelvin) DC resistance / low-impedance ohmic measurement |
| Probe Interface | 4-pin coaxial connector |
| Data Output | RS-232C |
| Dimensions | 100 mm (W) × 230 mm (D) × 45 mm (H) |
| Weight | 500 g |
| Power Supply | DC 6.5 V, 350 mA |
| Display | LCD |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VA-121 |
| Titration Method | Fully Automatic Coulometric Karl Fischer Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | ±0.1 µA |
| Water Content Range | 0.5 µg to 999.9999 mg |
| Accuracy | <0.3% RSD |
| Minimum Dispense Volume | 0 µL |
| Titration Control Precision | N/A |
| Heating Temperature Range | 250–1000 °C |
| Heating Module | Fe-Cr-Al Resistance Wire Electronic Furnace (800 W) |
| Max Sample Mass | ≤10 g |
| Detection Limit | ≥5 ppm (as H₂O) |
| Carrier Gas | Nitrogen, Flow Rate: 0.1–0.5 L/min |
| Power Supply | AC 100–120 V / 220–240 V, 50/60 Hz, 1100 VA |
| Dimensions (W×D×H) | ~420 × 260 × 420 mm |
| Weight | ~15.5 kg |
| System Configuration | VA-121 coupled with CA-310 Coulometric Titrator |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | VA-122 |
| Heating Zones | Low-Temp Furnace (70–300 °C) & High-Temp Furnace (250–1000 °C) |
| Heating Element | Fe-Cr-Al resistance wire, 1000 W |
| Sample Capacity | ≤10 g |
| Detection Limit | ≥10 ppm (as H₂O) |
| Carrier Gas | N₂, flow rate 0.1–0.5 L/min |
| Power Supply | AC 100–120 V or 220–240 V, 50/60 Hz, 1900 VA |
| Dimensions | 690 × 290 × 410 mm (W×D×H) |
| Weight | ~20 kg |
| Compatible Analyzer | CA-310 Coulometric Karl Fischer Titrator |
| Measurement Principle | Thermal liberation of surface-bound and adsorbed water prior to coulometric KF titration |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VA-210 |
| Titration Method | Fully Automated Coulometric Karl Fischer Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | ±0.1 μA |
| Water Content Range | 0.5 μg to 999.9999 mg |
| Measurement Accuracy | <0.3% RSD |
| Minimum Dispensing Volume | 0 μL |
| Titration Control Precision | N/A |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VA-230 |
| Titration Method | Fully Automatic Coulometric Karl Fischer Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | ±0.1 µA |
| Water Content Range | 0.5 µg to 999.9999 mg |
| Accuracy | <0.3% RSD |
| Minimum Dispense Volume | 0 µL |
| Titration Control Precision | 0 (coulometric, current-controlled) |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VA-236S |
| Titration Method | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | ±0.1 µA |
| Water Content Range | 0.5 µg to 999.9999 mg |
| Accuracy | <0.3% RSD |
| Minimum Dispensing Volume | 0 µL |
| Titration Control Precision | N/A (Coulometric mode, current-controlled electrolysis) |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer Accessory |
| Sample Introduction Method | Boat-type automated vaporization unit |
| Compatible Titrator | CA-310 |
| Moisture Measurement Range | 0.5 µg to 999.9999 mg |
| Measurement Resolution | ±0.1 µA |
| Accuracy | <0.3% RSD |
| Minimum Dispensing Volume | 0 µL |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VG-200 |
| Titration Method | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | ±0.1 μA |
| Water Content Range | 0.5 μg to 999.9999 mg |
| Accuracy | <0.3% RSD |
| Minimum Dispense Volume | 0 μL (mass/volume-controlled injection) |
| Titration Control Precision | High-stability current regulation with real-time coulometric feedback |
| Brand | MKS |
|---|---|
| Origin | USA |
| Model | MG6030 |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 10 ppb to 100% (gas-phase concentration) |
| Spectral Resolution | 0.5–128 cm⁻¹ |
| Scan Speed | 5 scans/sec at 0.5 cm⁻¹ |
| Detector | Liquid-nitrogen-cooled or thermoelectrically cooled MCT (HgCdTe) |
| Optical Path Length | 5.11 m |
| Purge Gas | Dry N₂ or CO₂-free air (dew point < −70 °C), flow rate 0.2 L/min |
| Pressure Sensor | MKS Baratron® capacitance manometer |
| Sample Temperature Range | Ambient to 200 °C |
| Sample Flow Rate | 0.2–10 L/min |
| Sample Pressure Range | 0.01–4 atm |
| Enclosure Material | Nickel-plated aluminum or 316 stainless steel |
| Weight | 50 kg |
| Dimensions | 445 mm (W) × 318 mm (H) × 648 mm (D) |
| Power | 110/220 VAC, 50/60 Hz, 3 A |