| Brand | 合肥科晶 |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Manufactured |
| Model | MgAl2O4 |
| Pricing | Upon Request |
| Crystal Structure | Cubic, Lattice Constant a = 8.085 Å |
| Growth Method | Czochralski (CZ) |
| Melting Point | 2130 °C |
| Density | 3.64 g/cm³ |
| Mohs Hardness | 8 |
| Thermal Expansion Coefficient | 7.45 × 10⁻⁶ /°C |
| Acoustic Velocity | 6500 m/s |
| [100] Shear Wave Propagation Loss (9 GHz) | 6.5 dB/µs |
| Color & Appearance | White, Transparent |
| Standard Orientations | <100>, <110>, <111> |
| Orientation Tolerance | ±0.5° |
| Standard Dimensions | 2" dia × 0.5 mm, 10 × 10 × 0.5 mm, 10 × 5 × 0.5 mm |
| Polishing | Single-side or double-side polished |
| Surface Roughness (Ra) | <5 Å |
| Packaging | Class 1000 cleanroom environment |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | MgO Crystal Substrate |
| Price | Upon Request |
| Crystal Structure | Cubic |
| Lattice Constant | a = 4.216 Å |
| Growth Method | Arc Melting |
| Melting Point | 2850 °C |
| Density | 3.58 g/cm³ |
| Mohs Hardness | 5.5 |
| Thermal Expansion Coefficient | 12.8 × 10⁻⁶ /°C |
| Dielectric Constant | 9.8 |
| Optical Transmittance | >90% @ 200–400 nm, >98% @ 500–1000 nm |
| Cleavage Plane | <100> |
| Orientations Available | <100>, <110>, <111> |
| Orientation Tolerance | ±0.5° |
| Standard Dimensions | Ø2" × 0.5 mm, 10 × 10 × 0.5 mm, 10 × 5 × 0.5 mm |
| Surface Finish | Single- or Double-Polished |
| Surface Roughness | Ra <15 Å for <111>, Ra <5 Å for <100> and <110> |
| Packaging | Class 1000 Cleanroom, Class 100 Clean Bag or Individual Wafer Cassette |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MH-5000 |
| Pricing | Available Upon Request |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MHW-3 |
| Drive Mechanism | Water-Hydraulic |
| Motion Resolution (Fine) | 0.2 µm (min. scale) |
| Coarse Travel Range (X/Y/Z) | 30 mm each |
| Fine Travel per Full Knob Rotation | 50 µm |
| Coarse Travel per Full Knob Rotation | ~4 mm |
| Control Unit Dimensions | 115 × 115 × 132 mm, 1.6 kg |
| Drive Unit Dimensions | 155 × 155 × 100 mm, 900 g |
| Hydraulic Tubing Length | 900 mm |
| Joint Type | Spherical Ball Joint (B-9 Standard) |
| Electrode Holder | H-12 Type |
| Included Accessories | Hex Key Wrench, Dual Adapter, Isolation Mounting Platform |
| Origin | Germany |
|---|---|
| Type | Portable Mercury Analyzer |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Gold Amalgamation Preconcentration |
| Detection Limit | ≤0.1 ng/m³ (or 0.5 pg Hg absolute) |
| Repeatability | ≤1.0% RSD |
| Linearity Error | ±1% |
| Sample Volume Range | 0.1–100 L |
| Sampling Cycle | 10 s–15 min |
| Measurement Cycle | 10 s–16 min |
| Measurement Range (10 L sample) | 0.1–2000 ng/m³ |
| Measurement Range (1 L sample) | 1–10,000 ng/m³ |
| Flow Control | Electronic mass flow meter |
| Pump Type | Diaphragm pump with Viton membranes |
| Filter | Disposable 0.45 µm PTFE membrane |
| Light Source | Electrodeless low-pressure mercury lamp (253.7 nm) |
| Data Storage | 10,000 records (~100 days) |
| Interface | USB & RS232 |
| Power Supply | 110/230 V, 50/60 Hz, max. 125 W |
| Dimensions (W×H×D) | 45 × 15 × 35 cm |
| Weight | ~9 kg |
| Operating Temperature | 5–35 °C |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MIBIscope |
| Price Range | USD 1.4M – 2.8M |
| Instrument Type | Time-of-Flight (TOF) |
| Primary Ion Beam Energy | 30 kV |
| Mass Range | >12,000 u |
| Mass Resolution | 11,000–16,000 (at m/z 150–200) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MIBIscope |
| Price Range | USD $720,000 – $1,200,000 |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Application Scope | General-Purpose Biomolecular Imaging |
| Spatial Resolution | 350 nm – 1 µm |
| Sensitivity Ratio | >10:1 |
| Stability | Excellent |
| Data Acquisition Rate | 50 Gbit/s |
| Mass Accuracy | <80 ppm |
| Acquisition Time (Low Res, 1 µm) | 9–35 min |
| Acquisition Time (High Res, 500 nm) | 17–68 min |
| Acquisition Time (Ultra-High Res, 350 nm) | 35–139 min |
| Multiplex Channel Capacity | ≥40 Protein Markers |
| ROI Size | 400 × 400 – 800 × 800 µm² |
| Antibody Detection Limit | 1 ion (¹¹³In) to 16 ions (¹⁶⁶Er) |
| Dynamic Range | 5 decades (10⁵) |
| Output Format | TIFF |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIBIscope |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Application Domain | Universal |
| Spatial Resolution | 350 nm – 1 µm |
| Sensitivity Ratio | >10:1 |
| Stability | Excellent |
| Data Acquisition Rate | 50 Gbit/s |
| Mass Accuracy | <80 ppm |
| Brand | Micheem / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | M4000 |
| Pricing | Upon Request |
| Brand | Michell Instruments |
|---|---|
| Origin | United Kingdom |
| Model Series | EA2, DMT143, DMT152 |
| Application | Laboratory & Process-Grade Dew Point Measurement |
| Accuracy | ±2 °Cdp |
| Certifications | ATEX, IECEx, UKCA, cQPSus |
| Sensor Technology | Ceramic Alumina (EA2), Vaisala DRYCAP® Polymer (DMT143/DMT152) |
| Output Options | 4–20 mA, 0–10 V, RS-485 Modbus RTU |
| Electrical Interface | MiniDIN 43650 (EA2), M12 (DMT143/DMT152) |
| Process Connections | 5/8″ UNF, 3/4″ UNF, G 1/2″, KF40 Flange |
| Materials | 316 Stainless Steel Wetted Parts |
| Calibration | NPL/NIST-Traceable Certificate Supplied |
| Typical Response Time | <10 s (t₉₀, DMT143/DMT152) |
| Operating Ambient | −40 to +60 °C |
| IP Rating | IP65 (EA2), IP66 (DMT143/DMT152) |
| Brand | Michell |
|---|---|
| Origin | United Kingdom |
| Model | SF52 |
| Product Type | Online Dew Point Transmitter |
| Measurement Principle | Chilled Mirror–Compensated Semiconductor Sensor |
| Operating Temperature Range | -40 to +60 °C |
| Accuracy (Dew Point) | < ±2 °C |
| Repeatability | < ±0.5 °C |
| Stability | < 1 °C/year |
| Response Time (T90) | < 10 s |
| Output Signals | 4–20 mA, 0–1 V, 0–5 V, or 0–10 V |
| Supply Voltage | 8–30 V DC (14–30 V DC required for 0–10 V output) |
| Power Consumption | 9 mA + load current |
| Supply Voltage Effect | ±0.005 %RH/V |
| Dew Point Range | -40 to +60 °C |
| Absolute Humidity Range | 0 to 200 g/m³ |
| Accuracy (Absolute Humidity) | 0.4 to 3 g/m³ (dependent on measured value) |
| Pressure Rating | Up to 20 bar (gauge) |
| Filter Type | Buffered flow-compensated sintered stainless-steel filter |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | MicOS |
| Application | Fluorescence Spectroscopy |
| Grating Configuration | Triple-grating imaging spectrometer with motorized grating turret |
| Spectral Range | 200 nm – 1600 nm |
| Imaging Capability | Integrated digital camera for real-time sample visualization |
| Microscope Orientation | Inverted or side-entry configuration (compatible with cryostats) |
| Excitation Laser Compatibility | 325 nm, 405 nm, 488 nm, 532 nm, 633 nm, 785 nm |
| Objective Options | 10×, 50×, 100× (UV-VIS-NIR optimized) |
| Spot Size | down to <10 µm (dependent on objective and wavelength) |
| Detector Options | Back-illuminated CCD (200–1050 nm), InGaAs array (800–1600 nm), UV-enhanced CCD (190–1100 nm), selectable per spectral segment |
| Software Platform | LabSpec 6 (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready) |
| Brand | Micro Emission |
|---|---|
| Origin | Japan |
| Model | MH-5000 |
| Instrument Type | Full-Spectrum Direct-Reading OES |
| Wavelength Range | 200–860 nm |
| Weight | 1.4 kg (including battery) |
| Power Supply | 6 AA batteries or AC adapter |
| Sample Volume | 40 µL |
| Element Coverage | >40 elements (including Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Cd, Ba, Pb, and rare earths) |
| Brand | Micro Emission |
|---|---|
| Origin | Japan |
| Model | MH-6000A |
| Instrument Type | Full-Spectrum Direct-Reading OES |
| Wavelength Range | 200–860 nm |
| Weight | 4.4 kg |
| Dimensions (L×W×H) | 31 × 16 × 20 cm |
| Power Consumption | 100 W |
| Gas Requirement | None |
| Cooling | Air-Cooled, No Water Circulation |
| Sample Introduction | Peristaltic Pump |
| Detector Configuration | Dual-Detector Array |
| Sample Form | Aqueous Liquids (with Optional Sapphire Flow Cell) |
| Brand | S.T. Japan |
|---|---|
| Origin | Japan |
| Model | Micro Vice |
| Type | Precision Microscopy Sample Holder & Rotational Stage Accessory |
| Mounting Compatibility | Standard Microscope Stage (e.g., Nikon, Olympus, Zeiss, Leica) |
| Angular Adjustment | 0° (horizontal), 15°, and 30° fixed-angle positions |
| Material | Stainless Steel (AISI 304) with Hard-Anodized Aluminum Base |
| Clamping Force Range | 0.2–5 N (adjustable via micrometer screw) |
| Minimum Sample Thickness | 10 µm |
| Maximum Sample Width | 25 mm |
| Repeatability | ±0.5° rotational alignment |
| Weight | 85 g |
| Brand | Microblox |
|---|---|
| Origin | France |
| Model | Microblox-OOC |
| Instrument Type | Multifunctional Microfluidic Perfusion Platform |
| Sample Compatibility | Standard 1/16" tubing, microscope-compatible chamber formats |
| Temperature Control Range | Ambient to 45 °C (±0.2 °C stability) |
| Humidity Control | Optional integrated module (20–95% RH, ±3% accuracy) |
| Gas Control | Manual air/CO₂ mixing or optional precision gas mixer (N₂/O₂/CO₂/air, ±0.5% flow accuracy) |
| Flow Rate Range | 10 nL/min – 5 mL/min (with selectable pressure or syringe pump actuation) |
| Positioning Precision | N/A (modular, non-robotic fluidic routing) |
| Cleaning Protocol | Solvent-compatible needle flush with programmable dwell time |
| Regulatory Compliance | Designed for GLP-compliant workflows |
| Brand | ESI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | microFAST Single Cell |
| Price | Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MicroHSImager |
| Pricing | Available Upon Request |
| Brand | Microlink / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Scientific-grade CMOS array (replacing legacy CCD) |
| Focal Length | 1000 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | 140 nm – 680 nm |
| Number of Simultaneous Detection Channels | 96 |
| Optical System | Dual-chamber vacuum-UV + UV-Vis configuration |
| Structural Material | Stress-relieved die-cast aluminum optical chamber (4-stage annealing) |
| Thermal Management | Active chamber temperature stabilization with laminar purge gas flow |
| Spectral Optimization | RTMC (Real-Time Multi-Channel) calibration and drift compensation algorithm |
| Compliance | Designed to support ISO/IEC 17025 workflows, ASTM E415, ASTM E1086, ASTM E3061, and GB/T 4336–2016 methodologies |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 3Flex |
| Gas Adsorption Capability | Physisorption & Chemisorption (optional) |
| Tri-Station Operation | Independent simultaneous analysis |
| Pressure Range | Down to 1×10⁻⁹ P/P₀ |
| Detection Limit | Ultra-micropore resolution (≤ 0.7 nm) |
| Vapor Compatibility | Integrated thermostatted manifold (45 °C ±0.05 °C), optional heated vapor dosing |
| Software | MicroActive™ with customizable reporting, ASTM/ISO-compliant data processing |
| Sample Preparation | In-situ tube heater for degassing under vacuum or inert gas |
| Sealing System | Metal-sealed, hard-stop valves with corrosion-resistant manifold |
| P₀ Measurement | Dedicated P₀ sensor with continuous saturation pressure monitoring |
| Fluid Library | >80 pre-loaded adsorbates (N₂, Ar, CO₂, H₂, Kr, H₂O, alcohols, hydrocarbons, etc.) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 |
| Temperature Range | –110 °C to 1100 °C |
| Detection Method | High-Stability TCD (Thermal Conductivity Detector) |
| Gas Inlets | 12 |
| Automated Valves | 4 × 6-port valves |
| Mass Flow Controllers | 4 (sample prep, dual carrier/reference, analysis) |
| Sample Tube | FlowThru™ quartz, rated to 1100 °C |
| TCD Zone Temperature | 150–250 °C |
| Optional Accessories | Online MS/FTIR/GC interface, vapor generator, cryogenic bath (–110 °C) |
| Software | Windows-based AutoChem software with GRAMS/32 peak processing module |
| Analytical Modes | TPD, TPR, TPO, TPRx, pulse chemisorption, isothermal reaction, BET surface area |
| Brand | ESL (Elemental Scientific Lasers) |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MicroMill2 |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | NIR/MIR |
| Price | Upon Request |
| Wavelength Range (NIR) | 0.6–1.7 µm, 0.9–2.1 µm |
| Wavelength Range (MIR) | 2.5–5 µm, 5–10 µm |
| Spectral Resolution | <9 nm (NIR), <12 nm (NIR), <30 nm (MIR), <50 nm (MIR) |
| Wavelength Accuracy | <0.5 nm (NIR), <2 nm (MIR) |
| SNR | >7000:1 (NIR), >1000:1 (NIR), >500:1 (MIR), >500:1 (MIR) |
| Integration Time | 4 ms |
| Dimensions (NIR) | 107 × 66 × 80 mm |
| Dimensions (MIR) | 107 × 110 × 80 mm |
| Power Supply | 9–18 V DC (NIR), 18–36 V DC (MIR) |
| Interface | USB, RS-485 |
| Detector Cooling | Optional thermoelectric (TE) cooling |
| Input Coupling | Free-space or fiber-optic |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | microPHAZIR AS |
| Price Range | USD 70,000–140,000 (FOB) |
| Principle | Portable, Non-Contact Reflectance NIR Spectroscopy |
| Measurement Time | <10 s |
| Sampling Mode | Non-Contact Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | Ruggedized Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp (Class 1 LED-equivalent Safety) |
| Data Interface | Internal Flash Memory + USB 2.0 Host Interface |
| Operating Temperature | 5–40 °C (non-condensing) |
| Power Supply | Dual Hot-Swappable Li-ion Batteries (4.5 h typical runtime) |
| Optional Accessories | AC Battery Charger, Carrying Case with Belt Clip |
| Brand | Microphotons |
|---|---|
| Origin | Imported |
| Manufacturer Type | OEM Manufacturer |
| Model | C3A-2700LAE |
| Pricing | Upon Request |
| Model | 318C+ |
|---|---|
| Price | Upon Request) |
| [Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | 318C+ |
| Wavelength Range | 350–800 nm |
| Filter Positions | 10 (standard: 405, 450, 492, 630 nm |
| Absorbance Range | 0.000–4.000 A |
| Optical Channels | 8-sample + 1 optional reference channel |
| Absorbance Stability | ≤ ±0.002 A or ≤ 0.5% T / 10 min |
| Accuracy | ≤ ±0.005 A or ±0.2% T |
| CV (Repeatability) | ≤ 0.2% |
| Sensitivity | ≥ 0.01 L/mg |
| Channel Uniformity | ≤ 0.01 A |
| Wavelength Accuracy | ±1 nm |
| Bandwidth (FWHM) | ≤ 8 nm |
| Display Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Read Time | ≤3 sec/96-well (single wavelength), ≤6 sec/96-well (dual wavelength) |
| Plate Types | Standard 96-well microplates, strips, flat/U/V-bottom wells |
| Display | 7-inch color TFT-LCD touchscreen |
| Input | Touchscreen + optional USB mouse/keyboard |
| Built-in Thermal Printer | Yes |
| Data Storage | ≥200,000 assay results, ≥500 test protocols (expandable) |
| Interfaces | USB-A, USB-B, RS-232, parallel port |
| Operating Environment | 5–40 °C, 15–80% RH |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Dimensions (L×W×H) | 475 × 350 × 210 mm |
| Weight | 11.5 kg] |
| Brand | GAOMAI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MIDAC Dynamic Calibration System |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Instrument Type | Laboratory Gas Chromatography Calibration Standard Generator |
| Application Scope | Universal Calibration for GC & FTIR |
| Gas Dilution Stages | Triple-stage |
| Mass Flow Controllers (MFCs) | Multi-channel digital MFC support |
| Corrosive Gas Compatibility | Yes (acidic, alkaline, organic) |
| Dilution Ratio Programmability | Yes, time-scheduled auto-run |
| Real-time Flow Monitoring | Yes |
| Repeatability | ≤ ±0.8% RSD (N₂ baseline, 10–1000 sccm) |
| Control Interface | PLC-based with 7″ TFT touchscreen (800×600) |
| PLC Cycle Time | Standard mode 160 µs |
| Onboard Memory | Display buffer 26 MB |
| Touchscreen Lifetime | ≥ 5 years (MTBF) |
| Brand | GAOMAI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | I-Series |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 4000–7500 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Scan Speed | 8 s per spectrum |
| Signal-to-Noise Ratio | <1% (RMS, 100 scans) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ across 4000–7500 cm⁻¹ |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | DMA-1 |
| Instrument Type | Portable |
| Measurement Principle | Catalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤0.1 ng |
| Linear Range | 0–1500 ng |
| Repeatability (RSD) | ≤1.0% |
| Linearity Error | ±10% |
| Sample Throughput | 2–5 min per analysis |
| Regulatory Compliance | EPA Method 7473, HJ 923–2017, GB 5009.17–2021 |