| Brand | Raykol |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XT-9910 |
| Sample Capacity | 6 or 8 Vessels |
| Microwave Source | 2450 MHz Variable-Frequency Magnetron |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±1 °C |
| Temp Uniformity | ±1 °C |
| Max Pressure | 6 MPa |
| Brand | Raykol |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | XT-9930 |
| Sample Capacity | 42 positions per batch |
| Brand | Raykol |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | XT-iMD |
| Price Range | USD 28,000 – 112,000 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 42 positions per batch |
| Microwave Source | 2450 MHz variable-frequency magnetron with high-energy microwave field generation |
| Max Temperature | 300 °C |
| Temperature Measurement Accuracy | ±0.1 °C |
| Temperature Control Stability | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Max Pressure | 6 MPa |
| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | DNP-3000 |
| Instrument Type | Quartz Glass Kjeldahl Distillation Apparatus |
| Nitrogen Measurement Range | 0.1–200 mg |
| Recovery Rate | 99.5% |
| Repeatability | ±1% |
| Distillation Time (100 mL) | 4 min |
| Cooling Water Consumption | 70 L/h |
| Power Rating | 2000 W |
| Programmable Parameters | Dilution Water (0–200 mL), NaOH Volume (0–200 mL), H₃BO₃ Volume (0–200 mL), Reaction Time (0–30 min), Digestion Time (0–30 min), Steam Intensity (30–100%) |
| Titration Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Temperature Compensation | CAT Pt100 probe |
| Predefined Programs | 3 fixed + 20 user-definable |
| Safety Features | Open-tube detection, digestion tube presence sensor, overtemperature cut-off thermostat |
| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | FLOC-4P |
| Speed Range | 20–200 rpm |
| Timer Range | 0–60 min |
| Positions | 4 |
| Power Supply | 12 V DC (cigarette lighter socket) |
| Stirrer Height Adjustment | Yes |
| Noise Level | Low |
| Application | Bench-scale coagulation/flocculation jar testing for water and wastewater analysis |
| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | SOXTEST |
| Extraction Chamber Volume | 50 mL |
| Receiver Flask Volume | 6 mL |
| Temperature Range | RT + 5 °C to 250 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Number of Channels | 6 |
| Solvent Recovery Rate | 60–70% |
| Sample Capacity | up to 25 mL |
| Reproducibility | ±1% |
| Extraction Thimble Dimensions | Ø26 × 60 mm |
| Boiling Extraction Time | 0–500 h |
| Rinsing Extraction Time | 0–99 h |
| Compatible Solvents & Max Recommended Extraction Temperatures | Diethyl Ether (100 °C), Petroleum Ether (100 °C), Hexane (140 °C), Chloroform (150 °C), Vinyl Chloride (190 °C), Methanol (200 °C), Ethanol (200 °C), Toluene (200 °C) |
| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | UCI-75 |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 300 W |
| Power Adjustment | Fixed (300 W) |
| Temperature Range | Ambient to 80 °C |
| Timer Range | 0–15 min |
| Tank Material | AISI 304 stainless steel (18/10 grade) |
| External Housing | AISI 304 stainless steel |
| Lid Type | Hinged sound-dampening cover |
| Drain Valve | Manual |
| Dimensions (L×W×H) | 320 × 265 × 165 mm (external) / 110 × 230 × 135 mm (internal) |
| Weight | 6 kg |
| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | VACUTERM |
| Instrument Type | Vacuum Oven |
| Temperature Range | 35–200 °C |
| Temperature Uniformity | ±4 °C |
| Temperature Stability | ±1 °C |
| Temperature Display Accuracy | ±2 °C |
| Maximum Vacuum Level | 0.01 mbar |
| Chamber Dimensions (W×D×H) | 34 × 32 × 32 cm |
| External Dimensions (W×D×H) | 62 × 53 × 49 cm |
| Chamber Material | AISI 304 Stainless Steel |
| Door & Interior Trim | AISI 304 Stainless Steel |
| Shelving | 2 Perforated Aluminum Shelves (Epoxy-Coated) |
| Heating Method | Forced-Air Circulation |
| Safety Compliance | EN 61010-1, EN 61010-2-010 |
| Temperature Sensor | PT100 Platinum Resistance Thermometer |
| Controller | Digital Microprocessor-Based Time-Temperature Controller |
| Safety Features | Dual-Level Independent Temperature Limiter, Tempered Double-Glazed Safety Glass Door, Silicone Sealing Gasket |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | No. 3 to No. 75 |
| Pricing | Available Upon Request |
| Diameter | 3/8″ (9.6 mm) |
| Overall Length | 16″ (406 mm) |
| Coated Length | 12″ (305 mm) |
| Handle Dimensions | 2″ × 2″ (51 mm × 51 mm) |
| Coating Thickness Range | 7.0–171.0 µm (corresponding to rod numbers 3–75) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Model | RE-3000A |
|---|---|
| Rotational Speed | 20–200 rpm (digital display) |
| Bath Temperature Range | Ambient to 90 °C (PID-controlled, digital readout) |
| Heating Bath | PTFE-coated stainless steel, fully enclosed heater, 1.4 kW |
| Condenser | Vertical dual-flow all-glass reflux condenser with standard taper joints (29/32 or 24/29) |
| Lift Range | 0–150 mm (motorized, automatic) |
| Total Power Consumption | 1.5 kW |
| Input Voltage | 220 V AC, 50 Hz |
| Sealing | Fluoroelastomer (FKM) vacuum gaskets |
| Feed System | Valve-type addition tube with PTFE tubing and splash guard ring |
| Vacuum Compatibility | ≤ 10 mbar typical operating range) |
| Origin | Germany |
|---|---|
| Type | Imported Laboratory Metal Bath |
| Model | RE-300B |
| Temperature Range | Ambient to 95 °C |
| Capacity | 3.5 L |
| Heating Power | 1300 W |
| Input Voltage/Frequency | 220–240 V / 50 Hz |
| Dimensions (W×D×H) | 260 × 280 × 200 mm |
| Chamber Material | Electropolished 316 Stainless Steel |
| Safety Features | Dry-run protection, Low-surface-temperature housing |
| Compliance | CE-marked, IEC 61010-1 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Rotational Speed Range | 20–190 rpm |
| Vacuum Tolerance | <1 mmHg |
| Vertical Travel Distance | 150 mm |
| Dimensions (W×D×H, excl. glassware) | 385 × 335 × 470–610 mm |
| Power Supply | 220 V, 50/60 Hz, 50 W |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | RE5000 |
| Rotational Speed Range | 0–110 rpm |
| Heating Temperature Range (Water Bath) | Ambient to 98 °C |
| Condenser Type | Vertical dual-coil high-density serpentine condenser with large-diameter tubing |
| Evaporation Flask Capacity | 5 L |
| Collection Flask Capacity (Standard Ground Joint) | 3 L |
| Total Power Consumption | 2120 W |
| Dimensions (W×D×H) | 600 × 400 × 850 mm |
| Lifting Mechanism | Motorized tilt-type lift with tactile paddle switch |
| Speed Display | Digital LED readout |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | RE5220 |
| Price | USD 4,700 (FOB Shanghai) |
| Rotation Speed Range | 20–110 rpm (digital display, frequency-controlled) |
| Heating Bath Temperature Range (water) | RT to 98 °C |
| Condenser Type | Vertical large-bore dual-coil serpentine condenser |
| Rotating Flask Capacity | 20 L |
| Collection Flask Capacity (standard ground-glass joint) | 10 L |
| Total Power Consumption | 5,180 W |
| Dimensions (W×D×H) | 1100 × 650 × 1900 mm |
| Brand | Yarong |
|---|---|
| Origin | Shanghai, China |
| Model | RE52AA |
| Capacity | 2 L |
| Ultimate Vacuum | 3 mmHg |
| Rotation Speed | 0–150 rpm |
| Temperature Control Range | 0–100 °C |
| Heating Bath Accuracy | ±1 °C (typical for digital PID-controlled stainless steel bath) |
| Condenser Surface Area | ≥0.12 m² (vertical dual-layer coil with high-efficiency coolant path) |
| Power Input | 1000 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Construction | Electropolished 304 stainless steel frame, PTFE-coated heating bath, borosilicate glassware (24/29 standard taper) |
| Brand | REACNOSTICS |
|---|---|
| Origin | Germany |
| Model | CPR |
| Reactor Type | Fixed-Bed |
| Construction Material | Borosilicate Glass |
| Operating Pressure | Up to 50 bar (High-Pressure Variant) |
| Maximum Temperature | 550 °C |
| Catalyst Bed Dimensions | 60 mm isothermal zone, 4 mm inner diameter |
| Optical Access | Integrated quartz windows for Raman, LIF, and UV-Vis spectroscopy |
| Compatibility | Coupled with MS, GC, FTIR, and operando spectroscopic systems |
| Heating Strategy | Zone-controlled external heating to prevent condensation in sampling lines |
| Automation | Fully programmable control unit with real-time data logging and remote operation capability |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | RC350G, RC400G, RC1400G, RC3000G |
| Temperature Range | −10 °C to 60 °C (RC1400G, RC3000G) or −5 °C to 60 °C (RC350G, RC400G) |
| Temperature Stability | ±0.25 °C (DIN 58966, with 10 L water at 20 °C) or ±0.5 °C (with 25 L water at 20 °C) |
| Cooling Capacity | 350–3000 W (at 20 °C ambient) |
| Heating Capacity | 0.75 kW (RC350G), 1.5 kW (RC400G), none (RC3000G) |
| Max. Flow Rate | 12–15 L/min |
| Reservoir Volume | 1.1–17.7 L |
| Pump Pressure @ 1 L/min | 0.62–1.6 bar |
| Power Supply | 230 V, 50 Hz |
| EMC Class | B (RC350G, RC400G, RC3000G), A (RC1400G) |
| Origin | Anhui, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Basic |
| Price Range | USD 0–2,800 |
| Reaction Volume | Small-scale |
| Construction Material | Stainless Steel (316L grade) |
| Operating Pressure | Low-pressure (≤0.3 MPa gauge) |
| Cooling System | Dual Peltier modules |
| Nominal Cooling Capacity | 110 W × 2 |
| Max. Power Consumption (incl. fans) | 400 W |
| No-load Minimum Temperature | 18 °C |
| Load-bearing Minimum Temperature (under full irradiation) | 28 °C |
| Temperature Control | ON/OFF hysteresis regulation |
| Temp. Stability | ±1 °C |
| Reactor Configuration | Integrated mainframe + interchangeable reaction chamber modules |
| Stirring Speed | 0–1000 rpm (magnetic coupling, single motor drive) |
| LED Power Supply | 4-channel output (24 V DC, 8 A per channel) |
| Total System Power (incl. light sources) | 600 W |
| Illumination Geometry | Tri-directional reflective illumination (front, rear, bottom) |
| Light Source Compatibility | Optimized for Kess-type high-intensity LED or halogen lamps (365 nm, 405 nm, 450 nm, white broadband) |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Genie A |
| Price Range | USD 7,000 – 14,000 (FOB Shanghai) |
| Purified Water Grade | ASTM Type I / GB/T 6682-2008 Grade I |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | < 0.01 ppb |
| Total Organic Carbon (TOC) | < 2 ppb |
| Microbial Count | < 0.001 CFU/mL |
| Endotoxin | < 0.001 EU/mL (with optional RephiBio final filter) |
| Particles (>0.1 µm) | < 1 particle/mL (with 0.2 µm final filter) |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | RG0C04000 / RG0C08000 |
| Price Range | USD 14,000 – 42,000 (est.) |
| Purified Water Grade | CLSI/ISO 15195 Clinical Laboratory Grade (Type II) |
| Resistivity | >10 MΩ·cm @ 25 °C (typical >16 MΩ·cm) |
| Total Organic Carbon (TOC) | <30 ppb |
| Particles (>0.2 � | m): Zero particles ≥0.22 μm |
| Microbial Count | <1 CFU/mL (with 0.2 μm terminal filter) |
| Feed Water Requirement | Municipal tap water, TDS <1000 ppm, temp. 5–35 °C, pressure 0.1–0.6 MPa |
| Pure Water Flow Rate | 40 L/hr or 80 L/hr (selectable model) |
| Handheld Dispenser Flow Rate | 0–2 L/min, stepless adjustment |
| UV Source | UVC LED @ 265 nm |
| Data logging | ≥2 years with USB export (immutable audit trail) |
| Compliance | Designed to support GLP/GMP workflows, 21 CFR Part 11-ready data handling |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Genie De-ion |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 1 ppt |
| Total Organic Carbon (TOC) | < 5 ppb |
| Microbial Count / Endotoxin | < 0.001 EU/mL |
| Particulates (>0.1 µm) | Zero detectable particles ≥ 0.1 µm |
| Flow Rate | 0–1.5 L/min |
| Dimensions (W×D×H) | 21 × 29 × 53 cm |
| Weight | 8 kg |
| Brand | RephiLe |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | Genie E |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Feed Water Requirement | Municipal tap water (conductivity ≤ 2000 µS/cm |
| Product Water Grade | ASTM Type II / ISO 3696 Grade 2 / GB/T 6682-2008 Grade II |
| Resistivity (25 °C) | >5 MΩ·cm (typical 10–16 MΩ·cm) |
| Heavy Metals & Soluble Silica | <0.01 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <1 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Flow Rate (EDI Product Water) | 5 / 10 / 15 L/h (selectable) |
| Dispense Flow Rate | 0–2 L/min |
| UV Wavelength | 265 nm (UVC LED, mercury-free) |
| Dimensions (H×W×D) | 54 × 32 × 44 cm (main unit) |
| Wireless Communication | Proprietary 2.4 GHz RF between main unit, touchscreen controller, and up to 10 remote dispensers |
| Integrated Sensors | Optional pH, DO, turbidity probes with real-time data overlay on HMI |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | RG0E03000 / RG0E06000 |
| Price Range | USD 14,000 – 42,000 (est.) |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | > 5 MΩ·cm (@ 25 °C, typical 10–16 MΩ·cm) |
| Total Organic Carbon (TOC) | < 30 ppb |
| Feed Water Requirement | Municipal tap water, TDS < 1000 ppm, Temp. 5–35 °C, Pressure 0.1–0.6 MPa |
| Output Flow Rate | 30 L/hr or 60 L/hr (EDI module) |
| Point-of-Use Flow Rate | 0–2 L/min |
| UV Wavelength | 265 nm (UVC LED) |
| Data Logging Duration | ≥ 2 years |
| Compliance | GLP-aligned architecture, audit-ready data export (USB), non-modifiable reports |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Genie G |
| Price Range | USD 14,000 – 42,000 (based on configuration) |
| Pure Water Grade | Type I (GB/T 6682-2008), ASTM D1193 Type II, ISO 3696 Grade 2 |
| Resistivity | > 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.01 ppb |
| Total Organic Carbon (TOC) | < 2 ppb |
| Microbial Count | < 0.001 CFU/mL (with 0.2 µm terminal filter) |
| Endotoxin | < 0.001 EU/mL (with RephiBio terminal filter) |
| Particles (>0.1 µm) | Zero particles ≥ 0.22 µm (with 0.2 µm terminal filter) |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Genie G5 |
| Price Range | USD 14,000–42,000 (FOB) |
| Purified Water Grade | ASTM Type I (Ultra-Pure) |
| Resistivity | 18.2 MΩ·cm @ 25 °C (temperature-compensated) |
| Heavy Metals & Soluble Silica | < 0.01 ppb |
| Total Organic Carbon (TOC) | < 5 ppb (µg/L) |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | Zero particles >0.22 µm detected |
| Bacterial Count | < 0.01 CFU/mL |
| RNase | < 0.5 pg/mL |
| DNase | < 10 pg/mL |
| Flow Rate (Ultra-Pure) | 0–2 L/min (adjustable) |
| Flow Rate (Pure Water) | 5 L/hr (continuous operation) |
| UV Wavelengths | 185 nm & 254 nm dual-lamp system |
| Integrated EDI Module | Electrodeionization with auto-regenerating mixed-bed ion-exchange resin |
| Water Storage Tank | 30 L or 60 L conical-bottom tank with air filter, UV disinfection, anti-overflow safety, and ±1% level accuracy |
| TOC Monitor | On-line, ±1 ppb accuracy |
| Conductivity/Resistivity Sensors | Four independent cells (0.01 cm⁻¹ cell constant, ±0.1 °C temp. sensitivity) |
| Compliance | ISO 9001:2015 certified manufacturing |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Model | Genie PURIST TOC |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.01 ppb |
| Total Organic Carbon (TOC) | < 5 ppb (with feed water < 50 ppb) |
| Microbial Count | < 0.01 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| RNase | < 0.5 pg/mL |
| DNase | < 10 pg/mL |
| Proteases | < 0.15 µg/mL |
| Particles (>0.22 µm) | Zero detectable particles |
| Flow Rate | 0–2 L/min (adjustable) |
| UV Lamp | Dual-wavelength (185/254 nm), >8000 h lifetime |
| Conductivity Cell Constant | 0.01 cm⁻¹, Temp. Sensitivity: ±0.1 °C |
| TOC Analyzer Accuracy | ±1 ppb |
| Data Logging | ≥2 years, USB export, audit-trail compliant |
| Compliance | ISO 9001:2015 certified, supports IQ/OQ/PQ, GLP/GMP-ready |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | Genie PURIST |
| Price Range | USD 14,000 – 42,000 (FOB Shanghai) |
| Feed Water | EDI-purified, RO, or distilled water |
| Resistivity | >18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.01 ppb |
| Total Organic Carbon (TOC) | <2 ppb (typical <5 ppb under standard operation) |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL (with optional RephiBio terminal filter) |
| Particles (>0.2 µm) | Zero particles ≥0.22 µm (with 0.2 µm terminal filter) |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | RG0R04000 / RG0R08000 |
| Pure Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Conductivity | < 20 µS/cm @ 25 °C |
| Flow Rate | 40 L/hr or 80 L/hr |
| RO Dispensing Flow | 0–2 L/min |
| Feed Water Requirements | TDS < 1000 ppm, Temp. 5–35 °C, Pressure 0.1–0.6 MPa |
| Dimensions (L×D×H) | 57 × 46 × 70 cm |
| Power Consumption | < 250 W |
| Brand | RephiLe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Genie R |
| Price Range | USD 7,000 – 14,000 (FOB Shanghai) |
| Purified Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Conductivity (@25 °C) | < 20 µS/cm (typical, with feed water < 500 µS/cm) |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 30 ppb |
| Microbial Count / Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| RO Production Flow Rates | 12 / 24 / 32 L/h |
| RO Dispense Flow Rate | 0–2 L/min |
| Feed Water Requirements | Conductivity/TDS < 2000 µS/cm / < 1000 ppm |
| Temperature | 5–35 °C |
| Pressure | 0.1–0.6 MPa (1–6 bar) |
| Dimensions (H×W×D) | 54 × 32 × 44 cm (main unit) |
| UV Wavelength | 265 nm (UVC LED, mercury-free) |