Electrochemical Instruments
Filter
Showing 721–750 of 1690 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LAQUAtwin pH B-711 (single-point calibration) / B-712 (dual-point calibration) |
| Instrument Type | Pen-type pH meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Resolution & Accuracy | ±0.1 pH |
| Minimum Sample Volume | 0.05 mL (with sampling film) or ≥0.1 mL |
| Calibration Solutions | pH 4.01, 7.00, and 9.18 standard buffers |
| Temperature Compensation | Automatic (ATC), 5–40 °C operating range |
| Ingress Protection | IP67 (submersible to 1 m for 30 min) |
| Power | Two CR2032 lithium coin cells |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, batteries excluded) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-711 / B-712 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Accuracy | ±0.1 pH |
| Resolution | 0.1 pH |
| Calibration Solutions | pH 4.01, 7.00, and 9.18 standard buffers |
| Calibration Modes | B-711 — single-point |
| Temperature Compensation | Automatic (ATC) |
| IP Rating | IP67 (dust-tight |
| Sample Volume | ≥0.05 mL (with optional sampling film) |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Power | Two CR2032 lithium batteries |
| Dimensions (L×W×H) | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, excl. batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-711 / B-712 |
| Instrument Type | Pocket pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Resolution & Accuracy | ±0.1 pH |
| Calibration | B-711 — One-Point (pH7) |
| Minimum Sample Volume | 0.05 mL (with optional sampling film) |
| Temperature Compensation | Automatic (5–40 °C) |
| IP Rating | IP67 (dust-tight |
| Power | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | pH-33 |
| Instrument Type | Pen-style |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| IP Rating | IP67 |
| Electrode Type | Integrated flat-surface pH electrode |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3552-10D |
| Cell Constant | 100 m⁻¹ (1 cm⁻¹) |
| Conductivity Range | 0.1 mS/cm to 10 S/cm (1 μS/cm to 100 mS/cm) |
| Minimum Sample Volume | 15 mL |
| Temperature Range | 0–100 °C |
| Part Number | 3014081545 (9096000900) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3553-10D |
| Cell Constant | 1000 m⁻¹ (10 cm⁻¹) |
| Conductivity Range | 1 mS/cm to 100 S/cm (10 μS/cm to 1 S/cm) |
| Minimum Sample Volume | 50 mL |
| Operating Temperature Range | 0–60 °C |
| Part Number | 3014081714 (9056001000) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 4163-10T |
| Temperature Range | 0–100 °C |
| Application | Integrated temperature sensing for automatic compensation in pH and ORP measurements |
| Part Number | 3014080375 (9003013000) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | OCMA-310 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S-316 |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OM-71 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (Dissolved Oxygen) |
| Measurement Range | 0.00–19.99 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.01 mg/L |
| Measurement Principle | Membrane-based Galvanic Cell |
| Temperature Compensation | 0–40 °C |
| Salinity Compensation | 0–40 ppt |
| Atmospheric Pressure Compensation | Yes |
| Saturation DO Range | 0.0–200.0 % |
| Oxygen Concentration Range | 0.0–50.0 % |
| Display | Backlit Monochrome LCD |
| Data Storage | 1000 records with timestamp, ID, and temperature |
| Environmental Rating | IP67 |
| Operating Temperature | 0–45 °C |
| Power | 2× AAA alkaline or Ni-MH batteries (≈500 h battery life) |
| Dimensions | 67 × 28 × 170 mm (max thickness 80 mm) |
| Weight | 270 g (body only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH-11 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Integrated flat-surface pH sensor |
| Sample Volume Requirement | As low as 100 µL |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH-22 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for GLP-compliant field and lab use |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH-22 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-surface pH sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine field and lab use in accordance with ISO 7888 and ASTM D1293 guidelines |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH-22 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Design | Flat-surface pH sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for general laboratory, field, and quality control use per ISO 3696 (Grade 3 water), ASTM D1293, and JIS K 0107 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH22 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine compliance with ISO 8655, ASTM D1293, and EPA Method 150.1 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH22 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Design | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine QC, field testing, and GLP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH22 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) with integrated temperature sensor |
| Sample Volume Requirement | As low as 100 µL |
| Electrode Design | Flat-surface pH sensing element |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine QC, field testing, and educational use in accordance with ISO 7888 and ASTM D1293 guidelines |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ToupH™ Series (e.g., 9615-10D, 9625-10D, 0040-10D) |
| Temperature Range | 0–100 °C (glass) |
| pH Range | 0–14 (standard) |
| Construction | Composite glass or ISFET sensing element with integrated temperature sensor and double-junction reference system |
| Compliance | Designed for ASTM D1293, ISO 10523, USP <791>, and GLP/GMP environments requiring traceable calibration and stable long-term drift performance |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | U-50 Portable |
| Instrument Type | Multiparameter |
| Parameter Count | 11 |
| pH Range | 0–14 |
| pH Resolution & Accuracy | 0.01 pH |
| ORP Range | −2000 to +2000 mV |
| DO Range | 0–50.0 mg/L |
| DO Resolution | 0.01 mg/L |
| Conductivity Range | 0–10 S/m |
| Turbidity Methods | LED forward scatter (U-53), tungsten lamp 90° scatter (U-53G), LED 90° scatter (U-54) |
| Turbidity Resolution | 0.01 NTU (0–10 NTU range) |
| Depth Measurement | up to 30 m (pressure-based, optional on U-52G/U-53G/U-54G) |
| Temperature Range | −10 to 55 °C |
| IP Rating | IP67 (host), IP68 (probe) |
| Battery Life | up to 70 h (alkaline AA ×4, backlight off) |
| Data Storage | 10,000 sets |
| Communication | USB |
| Calibration | 2-point pH (pH 4.01/7.00/9.18 buffers), multi-point turbidity/conductivity |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HK-307 |
| Detection Parameters | Single-parameter (Conductivity/TDS/Resistivity/Salinity/Temperature) |
| Form Factor | Benchtop |
| Conductivity Range | (0.00–20.00) µS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | (0.0–99.9) °C |
| Accuracy | ±1.5% FS |
| Minimum Resolution | 0.001 µS/cm |
| Display | 192 × 64 dot-matrix LCD (English/Chinese switchable) |
| Temperature Sensor | Pt1000 |
| Temp. Compensation | Automatic or Manual (0.1–60.0 °C, reference 25 °C, coefficient 0.00–9.99 %/°C) |
| Response Time (T90) | 30 s at 25 °C |
| Operating Ambient | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Power Consumption | 3 W |
| Dimensions | 270 × 200 × 65 mm (L×W×H) |
| Weight | 2 kg |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HK-3C |
| Instrument Type | Benchtop |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH |
| Calibration Solutions | GB/T 604–2002 compliant standard buffers (pH 4.00, 6.86, 9.18 at 25 °C) |
| Temperature Compensation | Automatic or manual (0.1–60.0 °C) |
| Input Impedance | ≥1 × 10¹² Ω |
| Response Time (T₉₀) | ≤60 s at 25 °C |
| Display | 192 × 64 dot-matrix LCD (switchable Chinese/English) |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Power Consumption | 3 W |
| Dimensions | 270 × 200 × 65 mm (L × W × H) |
| Weight | 1.5 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ElectraSyn 2.0 Package |
| Price | Upon Request |
| Input Voltage | 48 VDC |
| Max Input Current | 1500 mA |
| Output Voltage | 30 V / 10 V |
| Output Current | 100 mA |
| Motor Power | 9 W |
| Speed Range | 50–1500 rpm |
| Speed Setting Accuracy | ±10 rpm |
| Max Stirring Volume (H₂O) | 0.1 L |
| Stir Bar Length Compatibility | 8–16 mm |
| Speed Control | Rotary Knob |
| Display | TFT |
| Output Current Resolution | 0.1 mA |
| Output Voltage Resolution | 0.01 V |
| Current Measurement Resolution | 0.1 mA |
| Voltage Measurement Resolution | 0.1 V |
| Current Measurement Accuracy | ±0.1 mA |
| Voltage Measurement Accuracy | ±0.01 V |
| Dimensions (W×D×H) | 130 × 150 × 250 mm |
| Weight | 3.55 kg |
| Operating Temperature | 5–50 °C |
| Relative Humidity Limit | 80 % RH |
| Ingress Protection | IP40 per DIN EN 60529 |
| USB Interface | Yes |
| Mains Input | 100–240 V AC, 50/60 Hz |
| Device Input Power | 39.84 W |
| Standby Power Consumption | 5 W |
| DC Supply | 48 V = |
| DC Current Draw | 750 mA |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ElectraSyn 2.0 Pro Package |
| Voltage Input (Nominal) | 48 VDC |
| Max Input Current | 1500 mA |
| Output Voltage | 30 V / 10 V |
| Output Current | 100 mA |
| Motor Output Power | 9 W |
| Speed Range | 50–1500 rpm |
| Speed Setting Accuracy | ±10 rpm |
| Max Stirring Volume (H₂O) | 0.1 L |
| Stir Bar Length Compatibility | 8–16 mm |
| Output Current Resolution | 0.1 mA |
| Output Voltage Resolution | 0.01 V |
| Current Measurement Resolution | 0.1 mA |
| Voltage Measurement Resolution | 0.1 V |
| Current Measurement Accuracy | ±0.1 mA |
| Voltage Measurement Accuracy | ±0.01 V |
| Dimensions (W×D×H) | 130 × 150 × 250 mm |
| Weight | 3.55 kg |
| Operating Temperature Range | 5–50 °C |
| Max Relative Humidity | 80 % |
| Ingress Protection | IP40 (DIN EN 60529) |
| USB Interface | Yes |
| AC Input | 100–240 V, 50/60 Hz |
| Total Input Power | 39.84 W |
| Standby Power Consumption | 5 W |
| DC Supply | 48 V =, Current Draw: 750 mA |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | InAs Crystal Substrate |
| Pricing | Available Upon Request |
| Crystal Structure | Cubic, Lattice Constant a = 5.4505 Å |
| Growth Method | Czochralski (CZ) |
| Conductivity Type | N-type |
| Doping | Undoped |
| Carrier Concentration | 2–5 × 10¹⁶ cm⁻³ |
| Electron Mobility | >18,500 cm²/V·s |
| Standard Orientations | <100>, <111> |
| Standard Dimensions | 10 × 10 × 0.5 mm, Ø2″ × 0.5 mm |
| Surface Finish | Single-side or double-side polished |
| Surface Roughness (Ra) | <0.15 nm |
| Cleanroom Packaging | Class 1000 cleanroom processed, sealed in Class 100 cleanroom bags |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Model | SYTP-1 |
| Operating Frequency | 10 MHz |
| Mass Sensitivity | 2.26 × 10⁸ Hz/(g/cm²) |
| Mass Detection Range | 4.42 × 10⁻⁹ g/cm² to 4.42 × 10⁻⁴ g/cm² |
| Temperature Control Range | −196 °C to +70 °C |
| Vacuum Compatibility | Down to 1 × 10⁻⁵ Pa |
| Temperature Stability | ±0.1 °C |
| Frequency Resolution | ±1 Hz |
| Power Input | 100–240 VAC, 50/60 Hz |
| Interface Options | USB 2.0, Ethernet (RJ45), USB Flash Drive Data Export |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | InP Crystal Substrate |
| Pricing | Available Upon Request |
| Crystal Structure | Single-Crystal Indium Phosphide |
| Doping | Undoped / Sn / S / Fe / Zn |
| Conductivity Type | N-type (Sn, S, Fe) / Semi-Insulating (Fe, Zn) / P-type (Zn) |
| Hardness | 3.0 Mohs |
| Density | 4.78 g/cm³ |
| Refractive Index | 3.45 (at 10.6 µm) |
| Carrier Concentration | 1–2×10¹⁶ cm⁻³ (undoped), 1–3×10¹⁸ cm⁻³ (Sn-doped), 1–4×10¹⁸ cm⁻³ (S-doped), 6–4×10¹⁸ cm⁻³ (Fe-doped) |
| Dislocation Density | <5×10⁴ cm⁻² |
| Growth Method | Liquid Encapsulated Czochralski (LEC) |
| Melting Point | 1072 °C |
| Elastic Modulus | 7.1×10¹¹ dyn·cm⁻² |
| Standard Orientations | <100> |
| Standard Dimensions | 10 mm × 10 mm × 0.5 mm |
| Surface Finish | Single-Side or Double-Side Polished |
| Surface Roughness (Ra) | <15 Å |
| Cleanroom Handling | Packaged in Class 100 cleanroom bags within Class 1000 cleanroom environment |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | InSb Crystal Substrate |
| Pricing | Upon Request |
| Doping | None / Te / Ge |
| Conductivity Type | N / N / P |
| Carrier Concentration | 1–5 × 10¹⁴ cm⁻³ / 1–2 × 10¹⁵ cm⁻³ |
| Dislocation Density | < 2 × 10² cm⁻² |
| Standard Dimensions | 2″ (50.8 mm) diameter × 0.5 mm thickness |
| Surface Roughness (Ra) | < 15 Å |
| Packaging | Class 1000 cleanroom processed |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 pA to ±10 mA (12 ranges: 1 pA, 10 pA, 100 pA, 1 nA, 10 nA, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | −10 V to +10 V |
| EIS Frequency Range | 10 µHz to 3 MHz |
| Current Resolution | down to 0.6 aA (at selected range) |
| Potential Resolution | down to 0.07 nV (at selected range) |
| Applied Signal Resolution | 0.00013% |
| Measurement Resolution (current) | 0.00006% of selected range |