| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Inlab-2000 |
| Price Range | USD 1,400–7,200 (FOB) |
| Instrument Type | Laboratory-Scale BOD Analyzer |
| Measurement Principle | Microbial Electrode Method |
| Measurement Range | 2–4000 mg/L |
| Detection Limit | 2 mg/L |
| Accuracy | ±5% of reading |
| Single-Sample Analysis Time | ≤8 min |
| Repeatability (RSD) | ≤8% |
| Sensor Configuration | Integrated Triple-Electrode Sensor with Reference Electrode |
| Microbial Membrane | BOD₅-specific immobilized bacterial strain (no pre-cultivation required) |
| Membrane Shelf Life | >12 months (dry, ambient storage) |
| Temperature Control | Proportional PID heating |
| Data Storage | 140 measurement records with timestamp |
| Sample Volume Requirement | ≥30 mL |
| Operating Ambient | 5–40 °C |
| Dimensions (W×D×H) | 530 × 360 × 200 mm |
| Weight | 18.5 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | InLab-2016 |
| Instrument Type | Benchtop Laboratory Water Quality Analyzer |
| Measured Parameters | COD (High/Low Range), Ammonia-N, Total Phosphorus, Total Nitrogen, Nitrate-N, Nitrite-N, Free/Total Chlorine, Chlorine Dioxide, Hexavalent Chromium, Color, Turbidity, Suspended Solids, Sulfate, Sulfide, Fluoride, Aniline, Phosphate, Barium, Total Chromium, Iron, Ferrous Iron, Copper, Nickel, Zinc, Manganese, Dissolved Oxygen, pH, Temperature, Conductivity, ORP, Salinity, TDS, Cobalt, Ozone, Cyanide |
| Detection Method | Spectrophotometric (including DPD, Nessler, Molybdate, Cerium(IV)–Catalyzed Oxidation, etc.), Electrochemical (pH, DO, Conductivity, ORP, Salinity, TDS), and Gravimetric/Turbidimetric (SS, Sulfate) |
| Display | 7-inch TFT color capacitive touchscreen with Chinese UI |
| Data Storage | 10,000 measurement records with power-loss protection |
| Calibration | 1–7 point calibration with auto-curve adjustment |
| Connectivity | RS232 + USB |
| Dimensions | 300 × 220 × 120 mm |
| Weight | 2.8 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 5–40 °C, RH <85% (non-condensing) |
| Compliance Standards | HJ/T 399–2007, HJ 535–2009, GB 11893–89, GB 11892–89, EPA-approved methods, ISO 7027, ISO 5667, ASTM D1253, ASTM D3370 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | InLab-2022 |
| Pricing | Upon Request |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | InLab-2022 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Digestion Spectrophotometry |
| Wavelength Range | 590–610 nm |
| COD Range | 5–15,000 mg/L (high-range), 5–150 mg/L (low-range), 0–50 mg/L (permanganate method) |
| Repeatability | ≤ ±5% |
| Measurement Time | 20 min (typical COD cycle) |
| Batch Capacity | 15 samples |
| Temperature Control Range | 45–200 °C |
| Temperature Uniformity | ≤ 1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 370 × 250 × 140 mm |
| Weight | Approx. 4.2 kg |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | InLab-2100 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Spectrophotometry (C–H Bond Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹) |
| Measurement Range | 0.00–100 mg/L (water sample, 4 cm cell, direct analysis) |
| Detection Limit | <0.12 mg/L (water sample) |
| Accuracy | ±0.5 mg/L (for C < 10 mg/L) |
| Resolution | 0.1 ppm (0.001 mg/L) |
| Measurement Frequency | 10 samples per minute |
| Wavenumber Range | 3400–2400 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Absorbance Range | 0.0000–2.000 AU |
| Baseline Drift | <0.001 AU/60 min |
| Cell Compatibility | 0.5–5 cm pathlength cuvettes (standard: 4 cm) |
| Interface | RS-232 or USB |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz, 40 VA |
| Dimensions | 550 × 380 × 160 mm |
| Weight | ~14 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | InLab-2100 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at ~2960 cm⁻¹, ~2930 cm⁻¹, ~2850 cm⁻¹) |
| Measurement Range | 0.15 mg/L to 100 mg/L (using 5 cm quartz cuvette) |
| Detection Limit | <0.12 mg/L (CCl₄ extract, direct measurement with 5 cm quartz cuvette) |
| <0.001 mg/L (water sample, 100 | 1 extraction ratio, 5 cm quartz cuvette) |
| Accuracy | ±0.5 mg/L (C < 10 mg/L) |
| Resolution | 0.1 ppm |
| Measurement Frequency | 10 measurements/min |
| Wavenumber Range | 3400 cm⁻¹ – 2400 cm⁻¹ |
| Absorbance Range | 0.0000 – 3.000 AU |
| Baseline Drift | <0.001 AU/60 min |
| Repeatability | ≤1% (for 20 mg/L oil standard) |
| Linearity (R²) | >0.999 |
| Dimensions | 550 mm × 380 mm × 150 mm |
| Weight | 15 kg |
| Power Supply | 220 V ± 22 V AC, 50 Hz ± 1 Hz, 35 VA |
| Operating Environment | 5 °C – 35 °C, 20% – 80% RH |
| Interface | USB or RS-232 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | InLab-2200N |
| Principle | Infrared Spectrophotometry |
| Measurement Range | 0–800 mg/L (extract) / 0.0012–64,000 mg/L (water sample, 100:1 extraction ratio) |
| Detection Limit | <0.05 mg/L (water sample, typical) |
| Accuracy | ±0.4 mg/L (C < 10 mg/L), ±3% (10 ≤ C ≤ 80 mg/L) |
| Resolution | 0.001 mg/L |
| Wavenumber Range | 4000–2400 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Absorbance Range | 0.0000–3.000 AU |
| Baseline Drift | <0.001 AU/60 min |
| Measurement Frequency | 10 samples/min (discrete mode) |
| Cell Pathlength Compatibility | 0.5–5 cm |
| Interface | RS-232 or USB |
| Dimensions | 550 × 380 × 150 mm |
| Weight | ~14 kg |
| Power | 220 ± 22 V, 50 ± 1 Hz, 40 VA |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | InLab-2300 |
| Price Range | USD 1,400 – 7,200 |
| Instrument Type | Portable |
| Measurement Principle | Infrared Spectrophotometry (Dual-Wavelength & Full-Spectrum Scanning) |
| Measurement Range | 0.00–800 mg/L (in extract, using 0.5–4 cm pathlength cells) |
| Detection Limit | <0.4 mg/L (in CCl₄ extract) |
| <0.004 mg/L (in water sample, 40 | 1 extraction ratio, 4 cm quartz cell) |
| Accuracy | ±0.8 mg/L (C < 10 mg/L), ±4% (10 ≤ C ≤ 80 mg/L) |
| Repeatability | ≤3% (for 20 & 40 mg/L oil standards) |
| Resolution | 0.1 mg/L (in tetrachloroethylene) |
| Wavenumber Range | 3400–2400 cm⁻¹ (±1 cm⁻¹ repeatability) |
| Absorbance Range | 0.0000–2.000 AU |
| Baseline Drift | <0.001 AU/60 min |
| Sampling Frequency | 7 measurements/min |
| Power Supply | 220 V ±10%, 50 Hz, 40 VA |
| Dimensions & Weight | 470 × 380 × 210 mm, ~13 kg |
| Operating Environment | 5–35 °C, 20–90% RH |
| Battery Life | ~6 h (integrated Li-ion) |
| Interface | RS-232 or USB (configurable) |
| Compliance | HJ 637–2018 (China), ISO 9377-1:2000 (Petroleum Hydrocarbons), ASTM D7066–22 (Oil in Water by IR) |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | InLab-2400 |
| Price Range | USD 4,200 – 7,000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Target Analyte | Petroleum Hydrocarbons (Oil Content) |
| Compliance | HJ 970–2018 |
| Wavelength Range | 190–400 nm |
| Primary Measurement Wavelength | 225 nm |
| Absorbance Stability | ±0.005 Abs / 10 min |
| Absorbance Range | 0.000–2.000 Abs |
| Detection Limit | 0.001 mg/L |
| Repeatability | RSD ≤ 1% (for 2–20 mg/L oil standards, n=11) |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Correlation Coefficient | R > 0.9995 (calibration range: 0–20 mg/L) |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | InLab-2500 |
| Detection Method | UV Spectrophotometry (225 nm) |
| Extraction Solvent | n-Hexane |
| Compliance | HJ 970–2018 |
| Detection Limits | Petroleum Hydrocarbons ≤ 0.01 mg/L, Animal & Vegetable Oils ≤ 0.5 mg/L |
| Measurement Range | 0.01–100 mg/L |
| Repeatability | ≤1% (at 20 mg/L petroleum standard) |
| Linearity | R > 0.999 |
| Sample Throughput | Multi-sample capable (manual or optional auto-extraction) |
| Cell Type | 20 mm quartz cuvette |
| Data Storage | 10,000 records with power-loss protection |
| Interface | RS232 & USB |
| Operating Temp | 5–40 °C |
| Power | AC 220 V ±15%, 50 Hz, 28 W |
| Dimensions | 395 × 298 × 120 mm |
| Weight | 4.5 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | InLab-ET1020A |
| Price Range | USD 1,400 – 7,200 |
| Instrument Type | Benchtop Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (680 °C w/ catalyst or 900 °C non-catalytic) |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±3% of reading |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.05 ppm C |
| Repeatability | ≤3% RSD |
| Sample Loop Volumes | 25–400 µL (user-selectable) |
| Analysis Time | 4–8 min per TC/TIC/TOC cycle |
| Compliance | ASTM D5907, EPA Method 415.3, ISO 8245, EN 1484, DIN 38409-H32, USP <643>, Chinese National Standard GB 13193–1991 & WS/T 138–1999 |
| Brand | INNOTEG |
|---|---|
| Origin | Germany |
| Model | SAMPLING CASE |
| Instrument Type | Portable Automated Gas Sampler |
| Sampling Volume Range | 10–10,000 mL |
| Flow Control | Electronic Mass Flow Controller (MFC) |
| Adjustable Flow Rate Options | 1–50 mL/min or 5–250 mL/min (model-dependent) |
| Sampling Modes | Direct Ambient Air Sampling (XS, S, B), Overpressure Sampling (S, L, XL), Headspace Sampling (L, XL), Assisted Gas Dynamic Headspace Sampling (XL), Clinical Breath Sampling (B) |
| Power Supply | Rechargeable Li-ion Battery (24 V, 10 Ah) |
| Charging Input | 110–230 V AC, 50/60 Hz, 2 A |
| Display | Backlit LCD |
| Dimensions (W×D×H mm) | 340×295×150 (XS/S/B) |
| Weight | ~4 kg (uESK), ~5 kg (Strrer), ~6 kg (XS/S), ~10 kg (X), ~11 kg (XLB) |
| Compliance | Designed for field-deployable VOC sampling in accordance with ISO 16000-6, ASTM D6196, and EPA TO-17 workflows |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Dimensions | 15.5 × 10.5 × 5.5 cm |
| Material | Solid Pine Wood Body + Acrylic Lid |
| Base Liner | Foam-Mounted Optical White Board |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DIgialert-100 |
| Pricing | Upon Request |
| Display | LCD digital display with red LED alarm indicator |
| Operating Temperature Range | –10 °C to +50 °C |
| Detector Type | M-type GM tube with integrated beryllium-window (ICA) for alpha/beta/gamma detection |
| Sensitivity | 1000 CPM per mR/hr (calibrated with Cs-137) |
| Accuracy | ±10% typical |
| Dose Rate Range | 0.001–50 mR/hr |
| Count Rate Range | 0–50,000 CPM |
| Accumulated Count Range | 0–9,999,000 counts |
| Radiation Types Detected | Alpha (α), Beta (β), Gamma (γ), and X-rays |
| Audio Output | Audible alarm via 3.5 mm headphone jack |
| Power Supply | One 9 V alkaline battery (IEC 6LR61) |
| Battery Life | Up to 2000 hours (typical continuous operation) |
| Weight | 0.5 kg |
| Probe Integration | Integrated collimated GM detector assembly |
| Key | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Inspector USB |
| Instrument Type | Dose Rate / Contamination Meter |
| Detector | Halogen-quenched Geiger-Müller tube, 1.77" (45 mm) active diameter, mica window density 1.4–2.0 mg/cm² |
| Sensitivity | 3340 CPM per mR/hr (Cs-137 reference) |
| Energy Response | α ≥ 2.0 MeV, β ≥ 40 keV, γ/X ≥ 10 keV |
| Dose Rate Range | 0.001–100.0 mR/hr (0.001–1000 µSv/hr) |
| Count Rate Range | 0–350,000 CPM |
| Total Count Capacity | 1–9,999,999 counts |
| Display | 4-digit LCD with mode indicators |
| Update Interval | 3 s (adaptive averaging over prior 30 s at low levels) |
| Accuracy | ±10% to ±15% (traceable to NIST standards) |
| Alarm Thresholds | Adjustable 0.001–50 mR/hr or 1–160,000 CPM |
| Audio Alert | 70 dB @ 1 m (user-disableable) |
| Data Interface | USB 2.0 compliant port + CMOS audio output |
| Power | 9 V alkaline battery (typical life: 2160 h background, ~600 h at 1 mR/hr) |
| Operating Temperature | –10 °C to +50 °C |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 275 g (battery excluded) |
| Compliance | CE marked |
| certified per ISO 6980-1 | 2020 (reference radiation fields), calibrated and verified per ANSI N42.33-2021 for portable radiation detection instruments |
| Brand | Instantel |
|---|---|
| Origin | Canada |
| Model | Minimate Pro4 |
| Instrument Type | Portable |
| Memory Capacity | 64 MB non-volatile storage |
| Channel Count | 4 independent analog input channels |
| Sampling Rate | 512–65,536 S/s per channel (user-selectable, channel-independent) |
| Sensor Compatibility | ISEE/DIN triaxial velocity sensors, hydrophones, accelerometers, linear microphones, optional integrated sound level meter (IEC 61672-compliant) |
| Environmental Rating | IP65-rated metal enclosure with sealed connectors |
| Calibration Data Handling | Automatic sensor ID, calibration date, and sampling rate logging per channel |
| Event Storage | >8,000 events (including full-waveform records up to 2+ hours total) |
| Remote Data Transfer | Auto Call Home™ via GSM/CDMA/LTE modems or InstaLink™ cloud platform (TLS 1.2 encrypted, password-protected web portal) |
| Software Integration | Compatible with Instantel Blastware™ (VDV calculation, zero-crossing frequency analysis, histogram + waveform dual-mode recording, event report generation per ISEE/AGI/USACE standards) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | AirAware |
| Enclosure Rating | NEMA 4 |
| Power Supply | 12–24 VDC (optional 110/120 VAC adapter with North American plug) |
| Operating Temperature | −20 °C to 50 °C (−4 °F to 122 °F) |
| Humidity Range | 0–99% RH (non-condensing |
| Dimensions | 18.29 cm × 14.22 cm × 4.06 cm (7.2″ × 5.6″ × 1.6″) |
| Weight | 454 g (16 oz) |
| Sensor Technology | Electrochemical |
| Gas Detection Capabilities | CO (0–999 ppm, 1 ppm res), H₂S (0–999 ppm, 1 ppm res), NO (0–999 ppm, 1 ppm res), NH₃ (0–200 ppm, 1 ppm res), O₂ (0–30% vol, 0.1% res), SO₂ (0.2–99.9 ppm, 0.1 ppm res), NO₂ (0.2–99.9 ppm, 0.1 ppm res), Cl₂ (0.2–50 ppm, 0.1 ppm res), ClO₂ (0–1 ppm, 0.01 ppm res), HCN (0.2–30 ppm, 0.1 ppm res), HCl (0.2–30 ppm, 0.1 ppm res), PH₃ (0–1 ppm, 0.01 ppm res) |
| Output Options | 4–20 mA analog output, Modbus RTU (RS-485), configurable relay outputs (SPDT), local audible alarm (user-enabled/disabled), dual-intensity visual alarm LEDs |
| Calibration | Non-intrusive, tool-free span calibration using certified gas standards |
| Housing | Epoxy-coated aluminum with RF interference shielding |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-500E |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 10–650 mL/min |
| Flow Stability | ±2% |
| Flowmeter Accuracy | ±2.5% |
| Operating Duration at Max Flow & Backpressure | 40 h |
| Interface | USB-C (supports data export, firmware update, fast charging) |
| Connectivity | Bluetooth, Near-Field Communication (NFC), SparkLink (China’s StarFlash standard) |
| Calibration | On-device auto-calibration compatible with external flow calibrators |
| Smart Controls | Programmable Smart Key (double-click/long-press), voice activation via dedicated button |
| Power | Rechargeable Li-ion battery, full charge in ≤2 h |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 4160-2 |
| Price | USD 3,650 (FOB) |
| Principle | Electrochemical Sensor |
| Measurement Range | 0–19.99 ppm |
| Extended Low-Range Mode | 0–500 ppb |
| Resolution | 0.01 ppm |
| Accuracy | ±2% Rd ±0.01 ppm |
| Flow Rate | 1.0 L/min |
| Dimensions | 178 × 102 × 225 mm |
| Weight | 2.0 kg |
| Power | Rechargeable Li-ion battery with real-time voltage monitoring |
| Certification | China NIM Type Approval (Certificate No. 2021F012), Evaluated by Chinese Center for Disease Control and Prevention – Institute of Environmental Health and Related Product Safety |
| Brand | Interscan |
|---|---|
| Origin | USA |
| Model | 8160 |
| Detection Principle | Electrochemical Sensor |
| Measurement Range | 0–20.00 ppm (0–2000 ppb) |
| Resolution | 0.01 ppm / 1 ppb |
| Repeatability | ±0.5% of reading |
| Accuracy | ±2% Rd + 0.01 ppm |
| Response Time | <60 s |
| Linearity Error | ±1.0% (24 h) |
| Zero Drift | ±1.0% (24 h) |
| Span Drift | ≤±2.0% (24 h) |
| Sampling Method | Continuous pump-suction |
| Display | LCD with real-time graphing and data logging |
| Analog Outputs | 4–20 mA and 0–2.5 V |
| Battery Life | Up to 8 h (rechargeable Li-ion) |
| Operating Environment | 0–45 °C, 0–90% RH |
| Dimensions | 140 × 210 × 254 mm |
| Weight | 2.95 kg |
| Enclosure | Anodized aluminum housing |
| Brand | Ion Science |
|---|---|
| Origin | United Kingdom |
| Model | Tiger |
| Instrument Type | Portable VOC Detector |
| Detection Principle | Photoionization Detection (PID) |
| Detection Range | 1 ppb – 20,000 ppm |
| Resolution | 1 ppb |
| Accuracy | ±5% of reading |
| Response Time | <2 seconds |
| Sensor Technology | Patented ultra-low-power PID lamp with humidity-resistant electrode design |
| Operating Humidity Range | Up to 99% RH (non-condensing) |
| Battery Life | Up to 24 hours continuous operation |
| Data Interface | USB-C for real-time streaming and batch download |
| Compliance | CE, UKCA, ATEX II 2G Ex ia IIC T4 Ga, IECEx ia IIC T4 Ga, UL Listed Class I, Division 1, Groups A–D |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TIGER |
| Price Range | USD 1,400 – 7,000 (est.) |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Portable |
| Typical Configuration | Total VOC (TVOC) Detector |
| Measurement Range | 1 ppb – 20,000 ppm |
| Resolution | 1 ppb or 0.001 mg/m³ |
| Accuracy | ±5% of reading, ±1 digit |
| Response Time | T90 < 2 seconds |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer | IONICON Analytik GmbH |
| Model | FUSION PTR-TOF 10k |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Source VOC Monitoring System |
| Detection Range | 100 ppqv – 100 ppb |
| Mass Resolution | ≥10,000–15,000 m/Δm (FWHM) |
| Accuracy | ±0.001% of reading (mass axis calibration stability) |
| Response Time | ≤100 ms (90% signal rise time, T90) |
| Limit of Detection | <0.1 pptv (for selected VOCs, e.g., benzene, isoprene) |
| Sensitivity | up to 30,000 cps/ppbv (H₃O⁺ mode, for monoterpenes) |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | LCU |
| Configuration Options | LCU-s (Standard), LCU-a (Advanced) |
| Dilution Range | ppt to % (v/v) |
| Output Flow Rate | 0.1–50 L/min (single gas stream) |
| Accuracy | <5% (relative) |
| Response Time | <1 min (for concentration step change, including calculation latency) |
| Humidity Control Range | 10–100% RH @ 40 °C |
| Evaporation Optimization | Dynamic temperature-controlled liquid dosing with real-time vapor pressure compensation |
| Condensation-Free Operation | Integrated heated transfer lines and isothermal vapor path |
| Dimensions (W×H×D) | 35 × 35 × 15 cm |
| Weight | 10 kg |
| Optional LCU-a Enhancements | Dual liquid inlet (second for humidity reference), additional gas inlet with Sulfinet™-coated mixing manifold |
| Brand | IONICON Analytik G.m.b.H. |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 1000 |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Analyzer |
| Typical Configuration | Integrated VOC Monitoring System |
| Detection Range | 10 pptv – 1 ppmv |
| Resolution | 1 pptv |
| Accuracy | ±10 pptv |
| Response Time | ≤100 ms |
| Mass Range | 1–10,000 Th |
| Mass Resolving Power | >1500 (m/Δm) |
| Sampling Flow Rate | 50–800 sccm |
| Inlet & Reaction Chamber Heating | 40–180 °C and 40–120 °C respectively |
| Power Supply | 100–230 V AC, max. 1000 W |
| Dimensions (W×H×D) | 60 × 91 × 80 cm |
| Weight | 150 kg |
| Data Interfaces | Ethernet, RS232 |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 10K |
| Detection Principle | Proton-Transfer-Reaction (PTR) Ionization |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Gas-Stream VOC Analyzer |
| Detection Range | 1 pptv – 100 ppbv |
| Mass Resolution (m/Δm) | ≥10,000–15,000 |
| Accuracy | ±0.001% (relative mass accuracy) |
| Response Time | ≤100 ms |
| Detection Limit | <1 pptv |
| Sensitivity | >1000 cps/ppbv |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PTR-TOF 4000 |
| Pricing | Upon Request |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 6000X2 |
| Detection Limit | < 1 pptv |
| Sensitivity | > 2000 cps/ppbv |
| Mass Resolution | > 6000 (m/Δm, FWHM) |
| Ionization Modes | H₃O⁺, NO⁺, O₂⁺, NH₄⁺ |
| Response Time | < 100 ms |
| Ion Optics | ION-BOOSTER ion funnel + hexapole ION-GUIDE |
| Mass Analyzer | high-resolution iTOF (ion time-of-flight) |
| Optional Modules | SRI, Fast GC, AutoSampler (270-position), Multiplexing inlet, CHARON, LCU, BET |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | IONICON Analytik G m.b.H. |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTR-TOF QB |
| Detection Principle | Proton-Transfer-Reaction Time-of-Flight Mass Spectrometry (PTR-TOF MS) |
| Instrument Type | Portable |
| Typical Configuration | Multi-Analyte VOC Analyzer |
| Detection Range | C2–C12 Volatile Organic Compounds (VOCs), including aldehydes, ketones, aromatics, terpenes, oxygenates, and sulfur-containing compounds |
| Mass Resolution (m/Δm) | 4000 (FWHM at m/z 200) |
| Accuracy | ±5% relative to certified standard gas mixtures |
| Response Time | <100 ms (10–90% rise time for individual compounds) |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR3-TOF 10K |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with High-Resolution Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Stream Ambient Air Monitoring System |
| Detection Range | 0.1 pptv – 100 ppbv |
| Mass Resolution | Up to 15,000 m/Δm (FWHM) |
| Accuracy | ±0.001% mass accuracy (calibrated) |
| Response Time | < 100 ms (10–90% step response) |