| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IQ-1000 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IQ-350 |
| Pricing | Available Upon Request |
| Power Supply | 4×C alkaline batteries, optional NiCd rechargeable battery or AC adapter/charger |
| Battery Life | 20 hrs (alkaline), 12 hrs (NiCd) |
| Sensor Options | Solid-state, electrochemical, IR, PID |
| Gas Selection | User-configurable from >150 toxic, combustible, or volatile organic compounds |
| Resolution | 0.01 ppm (0–10 ppm), 0.1 ppm (10–100 ppm), 1 ppm (100–1000 ppm) |
| Accuracy | ±5% of reading |
| Sampling Method | Integrated diaphragm pump with 1.2 m sampling tube |
| Display | 3-digit LED |
| Alarm | Dual adjustable threshold (low/high), visual & audible |
| Operating Temperature | –20 °C to +50 °C |
| Storage Temperature | –20 °C to +60 °C |
| Humidity Range | 0–99% RH (non-condensing) |
| Enclosure | Anodized aluminum housing |
| Dimensions | 181.1 × 85.9 × 101.6 mm |
| Weight | 1.14 kg (incl. batteries) |
| Standard Accessories | Host unit, sampling probe, alkaline batteries, 110 VAC adapter/charger, operator manual, calibration certificate, washable carry case |
| Optional Accessories | NiCd rechargeable battery pack, 110/220 VAC universal converter |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | IR 400-KA |
| Pricing | Available Upon Request |
| Brand | Iris |
|---|---|
| Origin | Beijing, China |
| Model | IRIS Airborne Integrated LiDAR-Hyperspectral Imaging System |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2.7 nm |
| Sampling Interval | 2.1 nm |
| Spectral Bands | 561 (binned: 281) |
| Spatial Pixels per Line | 1364 |
| Max Frame Rate | 249 fps |
| LiDAR Scan Rate | 320,000 pts/sec |
| Max Range | 150 m |
| Horizontal Accuracy | ±2 cm (1σ) |
| Vertical Accuracy | ±1 cm (1σ) |
| IMU Attitude RMS (Pitch/Roll) | 0.04° (PPK-enabled) |
| GNSS Compatibility | BeiDou, GPS, GLONASS + RTK |
| System Weight | 2.4 kg |
| Brand | ISAP |
|---|---|
| Origin | Germany |
| Model | 4000e |
| Max. Flow Rate | 1000 m³/h (configurable: 200 / 500 / 700 / 1000 m³/h) |
| Operating Temperature Range | −30 °C to +40 °C (optional up to +50 °C) |
| Compliance | EU Directive 2008/50/EC, German 39th BImSchV, ISO 7708, ISO 8756, EN 481, TA Luft |
| Cut-Point Options | TSP, PM₁₀, PM₂.₅, UHVCI (Ultra-High-Volume Cascade Impactor) |
| Filter Compatibility | Glass microfiber, Quartz microfiber, Polyimide (Kapton®), Polycarbonate (PC), Polyester, Polypropylene (PP), PTFE (Teflon®), Polyurethane foam (PU), Polyvinyl fluoride (PVF/Tedlar®) |
| Optional Meteorological Sensors | Wind direction & speed, Relative humidity, Ambient temperature, Precipitation, Solar radiation, UV index, Total radiation, Acoustic noise, Vibration |
| Brand | ISAP |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISAP Arctic-Grade Aerosol Sampler |
| Pricing | Available Upon Request |
| Brand | ISAP |
|---|---|
| Origin | Germany |
| Model | ISAP LCPI |
| Flow Accuracy | ±2% |
| Sampling Flow Rate | 5–60 LPM |
| Temperature Range | −50 to +310 °C |
| Cut-Point Range | 20.0 µm to 1 nm |
| Stages | Up to 11 stages (13 size fractions) or 6 stages (8 size fractions) |
| Impactor Type | PILAT/BERNER design |
| Material | Acid-resistant alloys |
| Sampling Mode | Isokinetic or constant-flow |
| Backup Filter Stage | Optional 0.001 µm (1 nm) stage |
| Collison Disk Diameter | 70 mm OD / 30 mm ID |
| Brand | ISAP |
|---|---|
| Origin | Germany |
| Model | ISAP LPCI |
| Sampling Flow Rates | 5 L/min or 27 L/min |
| Aerodynamic Diameter Cut-Points | 20.0 µm to 1 nm |
| Temperature Range | −50 °C to +310 °C |
| Nozzle Plate Outer Diameter | 60 mm |
| Impaction Plate Inner Diameter | 20 mm |
| Calibration | Traceable, per-stage NIST-traceable impactor calibration |
| Materials | Acid-resistant stainless steel and inert alloys |
| Compliance | Designed for ISO 29463, ISO 14644, ASTM D1738, EPA Method IO-3.3, and EU Directive 2008/50/EC ambient PM monitoring frameworks |
| Brand | ISAP |
|---|---|
| Origin | Germany |
| Model | ISAP Marine Aerosol Sampler |
| Sampling Flow Rate | 500 L/min (adjustable) |
| Particle Size Cutpoints | TSP, PM10, PM2.5 |
| Environmental Sensors | Ultrasonic Anemometer (wind speed/direction), Temperature, Relative Humidity, Rain Gauge, Solar Radiation, UV Index, Ambient Noise, Vibration Sensor |
| Corrosion Protection | Marine-grade stainless steel & conformal-coated electronics |
| Compliance | Designed for EU FerryBox Project (2002–2005) deployment standards |
| Data Logging | Time-synchronized, auto-accumulated sampling duration |
| Flow Control | Closed-loop mass flow controller with pressure/temperature compensation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iSCAN |
| Price Range | USD 14,000 – 28,000 |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISCO 2150 |
| Pricing | Upon Request |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Model | 3700 Series |
| Enclosure Rating | NEMA 4X/6 (IP67) |
| Sampling Modes | Time-Proportional, Flow-Proportional, Event-Triggered (e.g., Storm Surge) |
| Sample Volume Accuracy | ±2% of set volume |
| Liquid Detection | Non-contact LD-90 Sensor (U.S. Patent No. 5,125,801) |
| Insulation | R-11 Foam (3700 Portable), Dual-Wall Construction |
| Bottle Capacity | Up to 24 × 1-L bottles (3700 Full-Size), 12 × 1-L bottles (3700C Compact) |
| Operating Temperature Range | –20 °C to +50 °C |
| Pump Type | Precision Peristaltic |
| Controller | Sealed, Corrosion-Resistant Housing |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Model | ISCO 4700 |
| Enclosure Material | Rotomolded Linear Low-Density Polyethylene (LLDPE) |
| Operating Temperature Range | –29 °C to +49 °C |
| Refrigeration System | High-Efficiency Compressor with Thermal-Insulated Cabinet |
| Pump Type | Heavy-Duty Peristaltic Pump |
| Maximum Lift Height | 7.6 m |
| Minimum Flow Velocity | 0.6 m/s (per US EPA requirements) |
| Sampling Modes | Time-Proportional, Flow-Proportional (Volume- or Time-Triggered), Composite or Discrete Bottle Sampling |
| Alarm Outputs | 4 Digital Relay Outputs |
| Input Compatibility | 4–20 mA and Pulse Flow Signals |
| Data Logging | Internal 24-hour Temperature & Event Log |
| Software Interface | RS-232 Serial Communication (HyperTerminal-Compatible) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Regional Origin | Domestic (China) |
| Model | ISCO 4700 |
| Pricing | Upon Request |
| Instrument Type | Portable Water Sampler |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISCO 6712 |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | ISCO 6712 |
| Quotation | Upon Request |
| Instrument Type | Portable Water Sampler |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Isco 5800 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ISI921VF |
| Pricing | Available Upon Request |
| Instrument Type | Spectroradiometer |
| Spectral Channels | 512 / 256 / 128 |
| Spectral Range | 380–1050 nm |
| Spectral Resolution | 2 nm / 4 nm / 8 nm @ 700 nm |
| Wavelength Accuracy | ±0.7 nm / ±1.4 nm / ±2.8 nm |
| Measurement Dynamic Range | >1000:1 (60 dB) |
| Standard Configuration | Host Unit ×1, Optical Head ×1, Smart Battery Charger ×1, Rugged Carry Case ×1, USB Communication Cable ×1, Software CD ×1, 2-m Extendable Handheld Mast ×1 |
| Optional Accessories | Calibrated Reflectance Panels (various sizes & reflectance levels), GPS Module, Synchronized Imaging Module, Extended Mast (~10 m), Indoor Calibration Light Source, Fixed-Position Mounting Frame, BRDF Measurement Rig |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iTrans |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | iTrans iTrans |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iTX |
| Pricing | Available Upon Request |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A |
| Detection Principle | Dual Flame Ionization Detection (FID) |
| Operating Temperature | 190 °C (heated sample path, detector chambers, and filter) |
| Filter Material | Stainless Steel |
| Filter Pore Size | 2 µm |
| Filtration Mode | Compressed Air or Nitrogen Back-Pulse Cleaning |
| Sample Inlet Configuration | Integrated Heated Sample Line with Adjustable Backplate Condensation Prevention System |
| Compliance | EN 14181, EN ISO 14956, EN 12619, EN 13526, EPA Method 25A, US EPA Reference Method 503 |
| Application Scope | Continuous Emission Monitoring (CEM), Stack Gas Analysis, Ambient Air NMHC Quantification, High-Purity Gas Purity Verification |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Emission Monitoring (CEM) Analyzer |
| Typical Configuration | Total Volatile Organic Compounds (TVOC) Analyzer |
| Measurement Range | 0–100,000 ppm (as propane or methane equivalent) |
| Resolution | 100 ppb |
| Accuracy | ±5% of reading |
| Response Time (T90) | <1 s |
| Operating Temperature of Sample Path & Detectors | 190 °C |
| Filter Material | Stainless Steel |
| Filter Pore Size | 2 µm |
| Purge Gas | Compressed Air or Nitrogen |
| Integrated Combustion Air Supply | Yes |
| Sample Pump | Integrated |
| Zero/Calibration Gas Management | Overload Protection with Automatic Calibration Sequence |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A-OVE |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Total VOC (TVOC) Monitoring System |
| Measurement Range | 0–1000 ppm (as propane equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109L |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Total VOC / THC / NMHC / CH₄ Analyzer |
| Measurement Range | 0–1000 ppm (selectable up to 100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Heating Chamber Temperature | 190 °C |
| Detector Sensitivity | ≤1 ppm full-scale for CH₄ |
| Carrier/Air Supply | Integrated zero-air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 155-15 |
| Sample Flow Range | 10–30 mL/min |
| Operating Temperature | 180 °C (heated sample path) |
| Detector Type | Flame Ionization Detector (FID) |
| Compliance | Designed for ASTM D5114, ISO 8712, and EPA Method 25A-compliant SHED testing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure | 19″ rack-mountable (5 U) or top-mount configuration |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 155-15FID |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Detection Range | 0–10,000 ppm C₁–C₁₀ (as methane equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±0.1 ppm (at low end), ±1% FS (full scale) |
| Response Time (T₉₀) | ≤3 s at 15 mL/min sample flow |
| Sample Flow Rate | Adjustable 10–30 mL/min (600–1,800 L/h) |
| Heating Zone Temperature | 180 °C (uniform, thermostatically controlled) |
| Integrated Combustion Air Supply | Yes (built-in compressor, no external air source required) |
| Brand | CHINYEE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3-200-3 |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-200 |
| Detection Principle | Flame Ionization Detection (FID) |
| Operating Temperature | 190 °C (heated sample path & detector chamber) |
| Response Time | < 1 s |
| Fuel | Hydrogen (low-pressure metal-hydride cartridge, 40 h runtime) |
| Combustion Air | Integrated air generator (no external cylinder required) |
| Sample Filtration | 2 µm stainless steel filter (permanent or replaceable) |
| Filter Cleaning | Automated compressed air or nitrogen back-purge (measurement uninterrupted) |
| Compliance | EPA Method 25A, EN 12619, ISO 8573-1 (gas purity), GLP/GMP-ready data handling |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-200 |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 to 0–100,000 ppm (selectable full-scale ranges) |
| Sensitivity | ≤1 ppm CH₄ full-scale |
| Response Time (T₉₀) | ≤0.2 s |
| Oven Temperature | 190 °C |
| Carrier/Air Supply | Integrated zero-air generator |
| Compliance | EN 12619, EN 13526, EPA Method 25A, EPA Method 503, 2nd/13th/17th BImSchV |