Environmental Monitoring Instruments
Filter
Showing 3931–3960 of 9112 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICD-1 |
| Price Range | USD 7,000 – 14,000 |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Variant-1 |
| Pricing | Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Variant-1 |
| Pricing | Upon Request |
| Brand | ICI / Infrared Cameras Inc |
|---|---|
| Origin | USA |
| Model | Mirage HC |
| Detector Type | Cooled InSb FPA (640 × 512) |
| Spectral Band | 3.2–4.2 µm (MWIR) |
| Effective Detection Range | Up to 1000 m (under optimal atmospheric conditions) |
| Compatible Platform | DJI Matrice 600 Pro with OGI Inspector (Plus) payload integration |
| Software | IR Flash Pro v5.2 (video-based spectral contrast enhancement, multi-angle analysis, audit-ready export) |
| Compliance | ASTM D7520-22 (Standard Practice for Optical Gas Imaging), ISO 17776:2016 (Offshore safety – Risk assessment), supports GLP/GMP-aligned metadata logging |
| Brand | ICT International |
|---|---|
| Model | AIM |
| Origin | Australia |
| Data Acquisition Channels | 5 differential or 10 single-ended analog inputs |
| Resolution | 24-bit (0.00001 V) |
| Accuracy | ±0.001 V |
| Minimum Sampling Interval | 1 s |
| Maximum Sampling Rate | 10 Hz |
| Data Storage | 4 GB internal + microSD card (FAT32, up to 64 GB) |
| Communication | USB 2.0 & 2.4 GHz wireless |
| Power Supply | 12 V DC non-polarized (24 V charger compatible) |
| Battery | Rechargeable polymer Li-ion with auto-variable charging (50–200 mA) |
| Operating Temperature | −40 °C to +80 °C |
| Humidity Range | 0–100% RH |
| Enclosure Rating | IP65 (sensor interface rated IP68) |
| Software Platform | Windows XP/Vista/7 |
| Data Format | CSV |
| Sensor Compatibility | Up to 5 ICT GT3-1 tensiometric infiltration sensors (±7 kPa, ±1% FS, 0.01 kPa resolution) |
| Brand | IDES |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1013 |
| Pricing | Upon Request |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IDS-20 |
| Pricing | Upon Request |
| Ice Thickness Range | 0.01–80 mm |
| Operating Temperature | −40 °C to +60 °C |
| IP Rating | IP66 |
| Power Supply | 10–28 VDC (sensor), 24 VAC/DC (heating) |
| Output Interfaces | SDI-12, RS-485 (Modbus), 3 relay outputs (rain / ice / failure) |
| Meteorological Parameters Measured | Air temperature (−40 to +60 °C), Relative humidity (0–100% RH), Dew point (−20 to +20 °C), Frost point (−20 to +20 °C) |
| Sensor Types | Cube Sensor (5 mm & 1 mm variants), Rod Sensor (80 mm range) |
| Weight | 0.7–3.6 kg (system-dependent) |
| Enclosure Dimensions | Up to 318 × 208 × 132 mm (controller) |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDH-01 |
| Pricing | Available Upon Request |
| Standard Compliance | IEC 62493:2015+A1:2021 |
| Frequency Range | 20 kHz – 10 MHz |
| Output Impedance | 50 Ω |
| Interface | BNC |
| Sensor Diameter | 210 mm |
| Cable Length | 300 mm |
| Weight | 1.7 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | IFC-2 |
| Price | USD 690 (FOB Beijing) |
| Flow Rate Range | 5–25 L/min (continuously adjustable) |
| Timer Range | 0–99 minutes |
| Power Supply | AC 220 V / DC rechargeable battery (≥3 h continuous operation) |
| Dimensions | 210 × 130 × 90 mm |
| Explosion Protection | Intrinsic Safety “ib I” per GB 3836.4–2021 / IEC 60079-11 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | IFC-2 |
| Pricing | Upon Request |
| Brand | IMI Medcom |
|---|---|
| Origin | USA |
| Model | Inspector |
| Detection Principle | Geiger-Müller (GM) Tube with Mica End-Window |
| Radiation Types | Alpha (α), Beta (β), Gamma (γ), and X-ray |
| Display | Digital LCD |
| Detector | Internal GM tube (45 mm effective mica window diameter) |
| Power Supply | One 9V alkaline battery (typical life: 200 hours) |
| Timer | Adjustable built-in timer |
| Calibration | External calibration port |
| Compliance | Designed for field-deployable radiation safety surveys per ANSI N42.33, IEC 60846, and ISO 4037-3 guidelines |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | 2800P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% FS |
| Response Time | <90 s |
| Drift Stability | <5% over 1 h |
| Measured Parameters | O₂, NO, NO₂, CO, SO₂, HC/CH₄, Flue Gas Temperature (TG), Ambient Temperature (TA) |
| Sensor Technology | Electrochemical (O₂, NO, NO₂, CO, SO₂, HC/CH₄) |
| Operating Temperature Range (Probe) | Up to 1200 °C (1600 °C optional) |
| Battery Life | 6 h (rechargeable Li-ion) |
| Compliance | Certified for official emission monitoring per German TA Luft and EU Directive 2010/75/EU (IED), supports ASTM D6522, EN 15267-3, and VDI 3862 |
| Data Output | RS232, USB |
| Display | Backlit LCD showing up to 8 parameters simultaneously |
| Built-in Printer | Yes (programmable, on-site thermal printout) |
| Fuel Database | 23 preloaded fuel types + 4 user-definable |
| Calculated Parameters | λ (excess air ratio), qA (dry flue gas loss), CO₂ (by ASME PTC 4.1 equation), NOₓ (as NO₂-equivalent) |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMR1400C |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | <2% FS |
| Repeatability | <2% FS |
| Response Time | 1 s |
| Stability | <2% FS over 8 h |
| Measurable Gases | O₂, NO, NO₂, CO, SO₂, HC/CH₄ |
| Optional Sensors | HCl, N₂O, Cl₂, H₂, NH₃, H₂S, CO₂ (IR) |
| Operating Temperature Range | –20 °C to +1200 °C (flue gas), –20 °C to +120 °C (ambient) |
| Dimensions | 305 × 228.6 × 117 mm |
| Weight | 2.9 kg |
| Battery Life | Up to 6 h (rechargeable Li-ion) |
| Communication Interfaces | RS232, USB |
| Compliance | Certified for official emissions monitoring per German TA-Luft and EU EN 15267-3 |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMR5000 |
| Instrument Type | Flue Gas CEMS |
| Measurement Accuracy | <2% FS |
| Repeatability | <2% FS |
| Stability | <2% FS |
| Response Time | Real-time |
| Measured Parameters | O₂, NO, NO₂, CO, SO₂, HC, CH₄, H₂S, HCl, NH₃, N₂O, O₃, PM |
| Sensor Technologies | Electrochemical (O₂, NO, NO₂, CO, SO₂, H₂S, NH₃, HCl, N₂O, O₃), NDIR (CH₄, CO₂*), Catalytic Bead (HC), Optional Paramagnetic (O₂), Thermal Conductivity (H₂), Optical Scattering (PM) |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMREX660 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | <2% FS |
| Repeatability | <2% FS |
| Response Time (T90) | <30 s |
| Stability | <2% FS over 8 h |
| Operating Temperature | –20°C to +50°C (toxic gases) |
| Operating Humidity | <95% RH, non-condensing |
| Weight | 500 g |
| Dimensions | 168 × 91 × 45 mm |
| Data Storage Capacity | 100,000 records |
| Battery Life | Up to 30 h (rechargeable Li-ion) |
| Detection Methods | Electrochemical, Catalytic Bead, NDIR, PID, and Semiconductor Sensors |
| Gas Channels | Up to 6 simultaneous sensor modules (7 gas parameters concurrently) |
| Alarm Modes | Dual-stage audible (buzzer), visual (LED flash), and tactile (vibration) |
| Compliance | Certified per German TA-Luft emission guidelines |
| Origin | Canada |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 3001 |
| Pricing | Available Upon Request |
| Water Level Sensor | Piezoresistive Silicon Sensor in 316L Stainless Steel Housing |
| Water Level Accuracy | ±0.05% FS |
| Water Level Resolution | 0.0006–0.028% FS |
| Temperature Sensor | Pt100 Platinum Resistance Thermometer |
| Temperature Accuracy | ±0.05°C |
| Temperature Resolution | 0.003°C |
| Conductivity Range | 0–8000 mS/cm |
| Conductivity Accuracy | ±1% of reading or ±15 mS/cm (whichever is greater) |
| Conductivity Resolution | 1 µS/cm |
| Sampling Interval | Programmable from 0.5 s to 99 h |
| Pressure Compensation | Integrated Barologger Atmospheric Pressure Sensor |
| Housing Materials | 316L Stainless Steel, Ceramic, Akulon®, Viton® |
| Operating Temperature | −20°C to +80°C |
| Data Storage | Internal High-Capacity Non-Volatile Memory |
| Battery Life | 5–10 years (typical deployment) |
| Brand | In-situ Marine |
|---|---|
| Origin | Australia |
| Model | CTD-Optics Series |
| Measurement Principle | High-stability quartz crystal conductivity cell, PT1000 RTD temperature sensor, piezoresistive pressure transducer |
| Data Logging | 16 GB microSD (timestamped binary + ASCII log files) |
| Power Management | Integrated 11.1 V / 7.8 Ah Li-ion battery with programmable sleep mode (65 µA) |
| Communication | Triple RS-232 channels (configurable baud rate 9600–115200 bps), optional Wi-Fi download & 4G telemetry via C-TEL interface |
| Compliance | IP68 rated housing |
| Environmental Rating | Long-term submersible deployment up to 100 m depth |
| Operating Temperature | 0–40 °C (ambient) |
| sensor range | −55 to +125 °C (temperature), 0–100 m (depth), 0–100,000 µS/cm (conductivity) |
| Brand | In-situ Marine |
|---|---|
| Origin | Australia |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DALEC |
| Pricing | Upon Request |
| Brand | In-situ Marine |
|---|---|
| Origin | Australia |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MS9-LPT |
| Pricing | Upon Request |
| Detector | 9 silicon photodiodes |
| Wavelengths | 410, 440, 490, 510, 550, 610, 660, 685, 710 nm (factory-customizable) |
| Spectral Bandwidth (FWHM) | 10 nm |
| Cosine Response Error | < 3% (0–60° incidence) |
| Radiance Field of View | 5° (in air) |
| Calibration | NIST-traceable radiometric calibration |
| Measurement Range | 0–400 μW·cm⁻²·nm⁻¹ (factory-customizable) |
| Noise-Equivalent Irradiance (NEI) | 2.5×10⁻³ μW·cm⁻²·nm⁻¹ |
| ADC Resolution | 24-bit per channel (9 independent channels) |
| Max Sampling Rate | 5 Hz (user-configurable) |
| Interface | RS-232 (baud rate configurable) |
| Data Transfer | Wi-Fi download support |
| Operating Voltage | 7–24 VDC |
| Current Draw | 40 mA (sampling), 250 mA (cleaning), 60 μA (sleep mode) |
| Connector | Micro WET-CON MCBH6M |
| Internal Battery | Rechargeable 11.1 V, 5.2 Ah Li-ion |
| Dimensions | 285 mm length (including 36 mm connector), 67 mm diameter |
| Mass | 1.4 kg (air), 0.3 kg (buoyant in seawater) |
| Housing Material | Acetal body, PTFE or quartz diffuser, copper cleaning panel/brush |
| Operating Temperature | 0–40 °C |
| Maximum Deployment Depth | 300 m |
| Brand | In-situ Marine |
|---|---|
| Origin | Australia |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | PAR |
| Pricing | Upon Request |
| Brand | In-situ Marine |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | pHiDO |
| Pricing | Upon Request |
| Brand | In-situ Marine |
|---|---|
| Origin | Australia |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | SC3/SC6 |
| Price | Upon Request |
| Scattering Angle | 120° |
| Ambient Light Rejection | Yes |
| Interference Suppression | Modulated Frequency per Channel |
| Reference Photodiode | Per LED Channel |
| Bb(λ) Range (Standard) | 0–1 m⁻¹ (Factory-Configurable) |
| Resolution | 5.0 × 10⁻⁴ m⁻¹ (Typ.) |
| Chlorophyll-a Range | 0–100 µg/L (Factory-Configurable) |
| Sensitivity | 0.01 µg/L |
| ADC Resolution | 16-bit |
| Sampling Frequency | 7 Hz (Configurable) |
| Communication Protocol | RS-232 @ 19200 bps |
| Input Voltage | 7–24 VDC |
| Power Consumption (Sampling) | 150 mA @ 12 VDC |
| Connector | MCBH6M |
| Length | 100 mm (including connector + 36 mm protrusion) |
| Diameter | 80 mm (SC3) or 125 mm (SC6) |
| Weight (Air) | 700 g |
| Housing Material | Acetal, Quartz, Copper Faceplate |
| Depth Rating | 300 m |
| Operating Temperature | −10 to +40 °C |
| Brand | In-situ Marine |
|---|---|
| Origin | Australia |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | SC6-LPT |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M40 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | M40 |
| Pricing | Upon Request |
| Enclosure Rating | IP65 |
| Dimensions | 109 × 62 × 35 mm |
| Weight | 244 g (326 g with SP40 pump) |
| Sensor Technology | Catalytic Bead (LEL), Electrochemical (O₂, CO, H₂S) |
| LEL Range | 0–100% LEL (1% LEL resolution) |
| CH₄ Range | 0–5% VOL (0.1% VOL resolution) |
| O₂ Range | 0–30% VOL (0.1% VOL resolution) |
| CO Range | 0–999 ppm (1 ppm resolution) |
| H₂S Range | 0–500 ppm (1 ppm resolution) |
| Battery Life | 18 h (12 h with SP40 pump) |
| Alarm | 90 dB audible, bright visual LED, vibration |
| Data Logging Capacity | 75 hours |
| Operating Temperature | −20 to +50 °C |
| Humidity Range | 15–95% RH (non-condensing) |
| Certifications | UL/CSA Class I, Groups A,B,C,D |
| Brand | Industrial Scientific |
|---|---|
| Origin | USA |
| Model | M40 |
| Instrument Type | Portable Gas Detector |
| Housing Material | High-impact, RFI/EMI-resistant composite |
| Dimensions | 10.9 cm × 6.22 cm × 3.48 cm |
| Weight | 244 g (instrument only), 326 g (with SP40 pump) |
| Gas Detection Capability | 1–4 gases simultaneously (O₂, H₂S, CO, combustible gas/LEL) |
| Sensor Types | Electrochemical (O₂, H₂S, CO), Catalytic Bead (combustibles) |
| Measurement Ranges | CO: 0–999 ppm (1 ppm resolution), H₂S: 0–500 ppm (1 ppm), O₂: 0–30% vol (0.1% vol), LEL: 0–100% LEL (1% LEL) |
| Battery | Rechargeable lithium-ion |
| Runtime | 18 h (instrument only, no alarm), 12 h (with SP40 pump, no alarm) |
| Display | Backlit LCD with amber backlight, high-contrast graphics, simultaneous 4-gas readout |
| Alarms | Visual (high-intensity LED flash), audible (90 dB), and vibratory |
| Data Logging | Up to 75 hours of time-stamped gas concentration data |
| Operating Temperature | −20 °C to +50 °C |
| Humidity Range | 15–95% RH (continuous), 0–99% RH (intermittent, non-condensing) |
| Ingress Protection | IP65 |
| Calibration | Simultaneous multi-sensor bump test and full calibration via single-gas or multi-gas standard |
| Warranty | 12 months |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MX6 |
| Pricing | Available Upon Request |
| Brand | INFICON |
|---|---|
| Origin | USA |
| Model | CMS5000 |
| Detection Principle | Purge-and-Trap GC with Micro-Ar Ionization Detector (MAID) |
| Regulatory Compliance | Designed per US EPA Method 502.2 |
| Sample Matrix | Raw water, finished drinking water, and treated water streams |
| Detection Limit | Sub-ppt (parts-per-quadrillion) for halogenated VOCs |
| Calibration Standard | Integrated long-life permeation tube (≥8 years) |
| Communication | Ethernet/Wi-Fi, FTP auto-reporting, remote method selection & data access |
| Enclosure Rating | NEMA 4X wall-mountable housing |
| Software | CMS IQ (programmable sequence control, default EPA methods, audit-trail enabled) |
| Maintenance Interval | <1 service/year (excluding purge water flush) |
| Carrier Gas | Ultra-high-purity argon (1.6 m³ cylinder lasts >12 months) |
| Brand | INFICON |
|---|---|
| Origin | Sweden |
| Model | IRwin |
| Instrument Type | Portable |
| Certification | ATEX II 1G, IECEx Ex ia IIC T3, EPL Ga, UL Listed Class I, Division 1, Groups B, C, D, T3 |
| Detection Principle | Dual-Mode Infrared (IR) + Gas Chromatography (GC) |
| Measurement Range | 1 ppm – 100 vol% CH₄ |
| Response Time (T90) | <2 s (IR mode) |
| IP Rating | IP54 |
| Operating Modes | Ground Survey, Probe Pinpointing, Universal Mode |
| GPS Integration | Yes |
| Wireless Data Transmission | Bluetooth® 5.0 + optional LTE module |
| Battery Life | 4 h runtime after 1 h fast charge |
| Compliance | DVGW G465-4, EN 60079-0/-11, ISO 8573-1 (air purity for sampling), US EPA Method 21 (leak detection), applicable OSHA & HSE guidance |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | InLab-2000 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Microbial Electrode Method |
| Measurement Range | 2–50 mg/L (extendable to 2–5000 mg/L via dilution) |
| Detection Limit | 2 mg/L |
| Accuracy | ≤1% |
| Single-Sample Analysis Time | 8 minutes |
| Repeatability | ≤5% |
| Sample Volume per Test | 50 mL |
| Buffer Consumption | 5 mL/min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 550 × 350 × 210 mm |
| Weight | 15 kg |