Environmental Monitoring Instruments
Filter
Showing 4621–4650 of 9112 results
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Temperature Range (Air) | −20.0 to +70.0 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Air Volume Calculation | Yes (rectangular & circular ducts, 0.1–255.0 cm dimensions) |
| Response Time (Velocity) | ~1 s (90%, at 1 m/s) |
| Response Time (Temperature) | ~30 s (90%, at 1 m/s) |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Data Hold Function | Yes |
| Statistical Functions | Min / Avg / Max |
| Auto Power-Off | 3 / 5 / 10 min selectable |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | Approx. 15 h (1 m/s, 20 °C) |
| Operating Environment (Body) | 5–40 °C |
| (Probe) | −20–70 °C |
| Storage Temperature | −20–60 °C |
| Weight | ~220 g (body only, no batteries) |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & flexible) |
| Cable Length | 2000 mm |
| Housing Material | Impact-resistant ABS |
| Compliance | CE-marked |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20 to 70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at wind speed > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Air Volume Calculation | Yes (1 m³/h minimum resolution) |
| Data Hold Function | Yes |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Statistical Functions | Min / Avg / Max |
| Auto Power-Off | 3 / 5 / 10 min selectable |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | Approx. 15 h (1 m/s, 20 °C, alkaline) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle), 294–1060 mm extendable & bendable |
| Cable Length | 2000 mm |
| Body Operating Temp. | 5–40 °C |
| Probe Operating Temp. | −20–70 °C |
| Storage Temp. | −20–60 °C |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Main unit, hot-wire probe, carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Resolution | 0.01 m/s |
| Velocity Accuracy | ±(3% of reading + 0.03 m/s) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Velocity) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Air Flow Calculation | Enabled for rectangular & circular ducts (cross-sectional dimensions input required) |
| Power | 4 × AA alkaline batteries (~15 h operation at 1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor tip) / Ø14 mm (handle), 294–1060 mm extendable & bendable |
| Cable Length | 2000 mm |
| Operating Environment (Body) | 5–40 °C |
| Storage Temperature | −20 to +60 °C |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Main unit, telescoping/bendable probe, protective carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20 to 70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Air Volume Resolution | 1 m³/h |
| Response Time (Velocity) | ~1 s (90%, at 1 m/s) |
| Response Time (Temperature) | ~30 s (90%, at 1 m/s) |
| Probe Dimensions | Ø6 mm (sensor), Ø14 mm × 294–1060 mm (telescoping handle) |
| Body Dimensions | 200 × 85 × 40 mm |
| Weight | ~220 g (without batteries) |
| Power | 4 × AA alkaline batteries |
| Battery Life | ~15 h (at 1 m/s, 20 °C) |
| Auto-Off Options | 3/5/10 min |
| Time Constant Settings | 1/5/10/20 s |
| Statistical Functions | Min/Avg/Max |
| Pipe Shape Support | Rectangular & Circular |
| Pipe Size Input Range | 0.1–255.0 cm |
| Display | 3-level backlight LCD |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20–70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Power | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Diameter | Φ6 mm (sensor), Φ14 mm (handle) |
| Probe Length | 294–1060 mm (telescoping & flexible) |
| Cable Length | 2000 mm |
| Weight | ~220 g (without batteries) |
| Included Accessories | Main unit, telescoping probe, protective carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20–70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90%, at 1 m/s) |
| Response Time (Temperature) | ~30 s (90%, at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Air Flow Display | Up to 1 m³/h |
| Data Hold Function | Yes |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Statistical Functions | Min / Avg / Max |
| Auto Power-Off | 3 / 5 / 10 min |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & flexible) |
| Cable Length | 2000 mm |
| Body Operating Temp. | 5–40 °C |
| Probe Operating Temp. | −20–70 °C |
| Storage Temp. | −20–60 °C |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Instrument body, telescoping/flexible probe, protective carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Resolution | 0.01 m/s |
| Velocity Accuracy | ±(3% of reading + 0.03 m/s) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Velocity) | ~1 s (90%, at 1 m/s) |
| Response Time (Temperature) | ~30 s (90%, at 1 m/s) |
| Air Volume Range | ≥1 m³/h |
| Pipe Shape Compatibility | Rectangular & Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Data Hold Function | Yes |
| Auto Power-Off Options | 3/5/10 min |
| Time Constant Settings | 1/5/10/20 s |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & bendable) |
| Cable Length | 2000 mm |
| Operating Environment (Body) | 5–40 °C |
| Storage Temperature | −20 to +60 °C |
| Weight | ~220 g (without batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20 to 70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Pipe Dimension Input Range | 0.1–255.0 cm |
| Air Volume Calculation | Yes (m³/h) |
| Data Hold Function | Yes |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Statistical Functions | Min / Avg / Max |
| Auto Power-Off | 3 / 5 / 10 min selectable |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & bendable) |
| Cable Length | 2000 mm |
| Body Operating Temp. | 5–40 °C |
| Probe Operating Temp. | −20–70 °C |
| Storage Temp. | −20–60 °C |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Main unit, telescoping probe, protective carrying case, quick-start guide, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Resolution | 0.01 m/s |
| Velocity Accuracy | ±(3% of reading + 0.03 m/s) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Velocity) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Air Volume Calculation | Yes (rectangular & circular ducts, 0.1–255.0 cm dimensions) |
| Data Hold, Min/Max/Avg Statistics, Adjustable Time Constant (1/5/10/20 s), Auto Power-Off (3/5/10 min), Backlit LCD (3-level), Battery Life | ~15 h (4 × AA alkaline), Weight: ~220 g (body only), Dimensions (body): 200 × 85 × 40 mm, Probe: Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & flexible), Cable Length: 2000 mm, Operating Environment (body): 5–40 °C, Storage Temp: −20–60 °C |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Resolution | 0.01 m/s |
| Temperature Range | −20 to 70 °C (probe), 5 to 40 °C (body) |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (90%) | ~1 s (velocity), ~30 s (temperature) |
| Air Volume Calculation | Yes (rectangular & circular ducts, 0.1–255.0 cm dimensions) |
| Data Logging Functions | Min/Max/Avg, Hold, Auto Power-Off (3/5/10 min), Adjustable Time Constant (1/5/10/20 s) |
| Display | 3-level backlight LCD |
| Power | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Dimensions (Body) | 200 × 85 × 40 mm |
| Probe | Ø6 mm (sensor) / Ø14 mm (handle), 294–1060 mm telescopic & bendable |
| Cable Length | 2000 mm |
| Weight | ~220 g (without batteries) |
| Compliance | Designed for ISO 14644-3, ISO 14644-4, EU GMP Annex 1, and USP <1116> environmental monitoring workflows |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Air Volume Calculation | Supported (rectangular & circular ducts, cross-section input 0.1–255.0 cm) |
| Display | 3-level backlight LCD |
| Power | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & flexible) |
| Cable Length | 2000 mm |
| Operating Environment (Body) | 5–40 °C |
| Storage Temperature | −20 to +60 °C |
| Weight | ~220 g (without batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20 to 70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Air Volume Calculation | Yes (rectangular & circular ducts, dimensions input required) |
| Data Hold, Min/Max/Avg Statistics, Adjustable Time Constant (1/5/10/20 s), Auto Power-Off (3/5/10 min), Backlit LCD (3-level), Battery Life | ~15 h (alkaline AA ×4), Weight: ~220 g (body only), Probe Dimensions: Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & bendable), Cable Length: 2000 mm |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20–70 °C |
| Operating Humidity | 2–98% RH |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Wind Speed) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Air Volume Range | 1 m³/h (calculated) |
| Pipe Types Supported | Rectangular and Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Data Hold, Min/Avg/Max Statistics, User-Adjustable Time Constant (1/5/10/20 s), Auto Power-Off (3/5/10 min), Backlit LCD (3-level), Battery Life | ~15 h (alkaline AA ×4) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & bendable) |
| Cable Length | 2000 mm |
| Weight | ~220 g (body only, no batteries) |
| Storage Temperature | −20–60 °C |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Resolution | ±(3% of reading + 0.03 m/s) |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature (Probe) | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Air Velocity Response Time | ~1 s (90% response at 1 m/s) |
| Temperature Response Time | ~30 s (90% response at 1 m/s) |
| Pipe Types Supported | Rectangular and Circular |
| Dimension Input Range | 0.1–255.0 cm |
| Air Volume Resolution | 1 m³/h |
| Data Hold Function | Yes |
| Time Constant Options | 1 s / 5 s / 10 s / 20 s |
| Display | Triple-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | Approx. 15 hours (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Φ6 mm (sensor) / Φ14 mm (handle) × 294–1060 mm (telescoping & bendable) |
| Cable Length | 2000 mm |
| Operating Environment (Body) | 5–40 °C |
| Storage Temperature | −20 to +60 °C |
| Weight | ~220 g (without batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Accuracy | ±(3% of reading + 0.03 m/s) |
| Velocity Resolution | 0.01 m/s |
| Temperature Range | −20–70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Airflow Calculation | Up to 1 m³/h (based on user-input duct dimensions) |
| Response Time (90%) | ~1 s (velocity, at 1 m/s), ~30 s (temperature, at 1 m/s) |
| Duct Types Supported | Rectangular and circular |
| Duct Dimension Input Range | 0.1–255.0 cm |
| Data Hold Function | Yes |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Display | 3-level backlight LCD |
| Power | 4 × AA alkaline batteries |
| Battery Life | Approx. 15 hours (1 m/s, 20 °C) |
| Operating Temp (Body) | 5–40 °C |
| Operating Temp (Probe) | −20–70 °C |
| Storage Temp | −20–60 °C |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & flexible) |
| Cable Length | 2000 mm |
| Weight | ~220 g (body only, no batteries) |
| Standard Accessories | Main unit, telescoping/flexible probe, carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Resolution | ±(3% of reading + 0.03 m/s) |
| Measurement Range | 0.01–20.0 m/s |
| Accuracy | ±(3% of reading + 0.03 m/s) |
| Operating Temperature | −20–70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Velocity Response Time | ~1 s (90% response at 1 m/s) |
| Temperature Response Time | ~30 s (90% response at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Pipe Dimension Input Range | 0.1–255.0 cm |
| Air Volume Range | ≥1 m³/h |
| Data Hold Function | Yes |
| Time Constant Options | 1 s / 5 s / 10 s / 20 s |
| Display | 3-level backlight LCD |
| Power | 4 × AA alkaline batteries |
| Battery Life | ~15 h (1 m/s, 20 °C) |
| Body Dimensions | 200 × 85 × 40 mm |
| Probe Dimensions | Ø6 mm (sensor) / Ø14 mm (handle) × 294–1060 mm (telescoping & bendable) |
| Cable Length | 2000 mm |
| Body Operating Temp | 5–40 °C |
| Storage Temp | −20–60 °C |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Instrument body, telescoping/bendable probe, protective carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s (air velocity), 0.1 °C (temperature) |
| Measurement Range | 0.01–20.0 m/s (air velocity), −20.0–70.0 °C (temperature) |
| Accuracy | ±(3% of reading + 0.03 m/s) for air velocity |
| Operating Environment | −20–70 °C (probe), 5–40 °C (main unit) |
| Response Time | ~1 s (90% for velocity at 1 m/s), ~30 s (90% for temperature at 1 m/s) |
| Pipe Compatibility | Rectangular and circular ducts |
| Duct Dimension Input Range | 0.1–255.0 cm |
| Air Flow Calculation | Direct m³/h output based on user-entered cross-sectional area |
| Data Logging Features | Min/Max/Avg statistics, data hold, programmable time constant (1/5/10/20 s), auto power-off (3/5/10 min) |
| Display | 3-level backlight LCD |
| Power | 4 × AA alkaline batteries (~15 h operation at 1 m/s, 20 °C) |
| Dimensions | Main unit 200 × 85 × 40 mm |
| Cable | 2000 mm |
| Weight | ~220 g (without batteries) |
| Compliance | Designed for industrial HVAC, cleanroom, and laboratory airflow verification per ISO 14644-3, ASHRAE 110, and JIS B 8402 standards |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KA25 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Accuracy | ±(3% of reading + 0.03 m/s) |
| Velocity Resolution | 0.01 m/s |
| Temperature Range | −20–70 °C |
| Temperature Accuracy | ±0.5 °C (at v > 0.5 m/s) |
| Temperature Resolution | 0.1 °C |
| Response Time (Velocity) | ~1 s (90% response at 1 m/s) |
| Response Time (Temperature) | ~30 s (90% response at 1 m/s) |
| Pipe Shape Compatibility | Rectangular & Circular |
| Pipe Dimension Input Range | 0.1–255.0 cm |
| Air Volume Calculation | Yes (1 m³/h minimum resolution) |
| Data Hold Function | Yes |
| Time Constant Settings | 1 s / 5 s / 10 s / 20 s |
| Display | 3-level backlight LCD |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | Approx. 15 h (1 m/s, 20 °C) |
| Operating Temp (Body) | 5–40 °C |
| Operating Temp (Probe) | −20–70 °C |
| Storage Temp | −20–60 °C |
| Dimensions (Body) | 200 × 85 × 40 mm |
| Probe Diameter | Φ6 mm (sensor) / Φ14 mm (handle) |
| Probe Length | 294–1060 mm (telescopic & bendable) |
| Cable Length | 2000 mm |
| Weight | ~220 g (without batteries) |
| Standard Accessories | Main unit, telescopic probe, carrying case, quick-start manual, batteries |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA26 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.00–50.0 m/s |
| Velocity Resolution | 0.1 m/s (0.01 m/s in 0.00–9.99 m/s range) |
| Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Temperature Range | −20.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C (−20.0–0.00 °C and 60.0–100.0 °C: ±0.5 °C) |
| Pressure Range | 0.00 to ±5.00 kPa |
| Pressure Resolution | 0.01 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Response Time (Velocity) | ~1 s |
| Response Time (Temperature) | ~30 s |
| Response Time (Pressure) | ~1 s |
| Display | 3.5-inch resistive touchscreen |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Battery Life | Approx. 10 h (at 5 m/s, 20 °C) |
| Operating Environment (Unit) | 5–40 °C |
| Operating Environment (Probe) | −20–100 °C |
| Storage Temperature | −30–60 °C |
| Dimensions (Unit) | 160 × 80 × 32 mm |
| Probe Dimensions | Φ10 mm sensor |
| handle | 40 × 27 × 125 mm |
| extendable length | 260–330 mm |
| Weight | ~600 g |
| Probe Extension Capability | Up to 1240 mm with included extension rod |
| Compliance | Designed for industrial hygiene, HVAC commissioning, and cleanroom monitoring per ISO 14644-3, ASHRAE 110, and ANSI/ASHRAE Standard 111 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KA26 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.1 m/s (0.01 m/s in 0.00–9.99 m/s range) |
| Measurement Range | 0.00–50.0 m/s (air velocity), −20.0–100.0 °C (temperature), −5.00 to +5.00 kPa (differential pressure) |
| Accuracy | ±3% of reading or ±0.015 m/s (whichever is greater) for velocity |
| ±0.3 °C (−20.0–0.00 °C and 60.0–100.0 °C | ±0.5 °C) for temperature |
| Operating Temperature (Body) | 5–40 °C |
| Storage Temperature | −30–60 °C |
| Response Time | ~1 s (velocity & pressure), ~30 s (temperature) |
| Display | 3.5-inch resistive touchscreen |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Power | Rechargeable Li-ion battery (≈10 h operation at 5 m/s, 20 °C), AC adapter included |
| Weight | ≈600 g |
| Dimensions (Body) | 160 × 80 × 32 mm |
| Probe | Ø10 mm sensor tip, 40 × 27 × 125 mm (handle), extendable up to 1240 mm with optional extension rod |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA26 / KA36 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.00–50.0 m/s |
| Velocity Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Temperature Range | −20.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Pressure Range | −5.00 to +5.00 kPa |
| Pressure Resolution | 0.01 kPa |
| Velocity Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Temperature Accuracy | ±0.3 °C (−20.0–0.0 °C and 60.0–100.0 °C: ±0.5 °C) |
| Pressure Accuracy | ±0.1 kPa |
| Response Time (Velocity) | ~1 s |
| Response Time (Temperature) | ~30 s |
| Response Time (Pressure) | ~1 s |
| Display | 3.5-inch resistive touchscreen |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Battery Life | ~10 hours (at 5 m/s, 20 °C) |
| Operating Temperature (Body) | 5–40 °C |
| Operating Temperature (Probe) | −20–100 °C |
| Storage Temperature | −30–60 °C |
| Dimensions (Body) | 160 × 80 × 32 mm |
| Probe Dimensions | Ø10 mm sensor |
| handle | 40 × 27 × 125 mm |
| extendable length | 260–330 mm |
| Weight | ~600 g |
| Accessories | Probe extension rod (up to 1240 mm), pressure tubing (1.5 m), AC adapter (USB-C), carrying case, manual |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KA26 / KA36 |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.00–50.0 m/s |
| Velocity Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Temperature Range | −20.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Pressure Range | −5.00 to +5.00 kPa |
| Pressure Resolution | 0.01 kPa |
| Velocity Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Temperature Accuracy | ±0.3 °C (0.0–60.0 °C), ±0.5 °C (−20.0–0.0 °C and 60.0–100.0 °C) |
| Pressure Accuracy | ±0.1 kPa |
| Response Time (Velocity) | ~1 s |
| Response Time (Temperature) | ~30 s |
| Response Time (Pressure) | ~1 s |
| Display | 3.5-inch resistive touch LCD |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Power | Rechargeable Li-ion battery (≈10 h @ 5 m/s, 20 °C), AC adapter (USB-C) |
| Operating Environment (Body) | 5–40 °C |
| Operating Environment (Probe) | −20–100 °C |
| Storage Temperature | −30–60 °C |
| Dimensions (Body) | 160 × 80 × 32 mm |
| Probe Dimensions | Φ10 mm sensor tip |
| handle | 40 × 27 × 125 mm |
| extendable length | 260–330 mm (up to 1240 mm with extension rod) |
| Weight | ≈600 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.00–50.0 m/s (wind speed), −20.0–100.0 °C (temperature), −5.00–+5.00 kPa (differential pressure) |
| Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s), 0.1 °C, 0.01 kPa |
| Accuracy | ±max(3% of reading, 0.015 m/s) for wind speed |
| ±0.3 °C (−20.0–0.0 °C and 60.0–100.0 °C | ±0.5 °C) |
| Response Time | ~1 s (wind speed & pressure), ~30 s (temperature) |
| Display | 3.5-inch resistive touchscreen |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Battery Life | ~10 hours (typical cleanroom operating conditions) |
| Operating Temperature (Body) | 5–40 °C |
| (Probe) | −20–100 °C |
| Storage | −30–60 °C |
| Weight | ~600 g (body only) |
| Probe Reach | Adjustable up to 1240 mm with extension rod |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.00–50.0 m/s |
| Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Temperature Range | −20.0–100.0 °C (0.1 °C resolution) |
| Pressure Range | −5.00–+5.00 kPa (0.01 kPa resolution) |
| Operating Environment | Body: 5–40 °C |
| Probe | −20–100 °C |
| Storage | −30–60 °C |
| Response Time | Wind Speed ≈1 s, Temperature ≈30 s, Pressure ≈1 s |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Battery Life | ~10 hours (at 5 m/s, 20 °C) |
| Weight | ~600 g |
| Dimensions (Body) | 160 × 80 × 32 mm |
| Probe Reach | Adjustable up to 1240 mm with extension rod |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.00–50.0 m/s |
| Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Temperature Range | −20.0–100.0 °C |
| Temperature Accuracy | ±0.3 °C (0.0–60.0 °C), ±0.5 °C (−20.0–0.0 °C and 60.0–100.0 °C) |
| Pressure Range | −5.00 to +5.00 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Response Time | ~1 s (air velocity & pressure), ~30 s (temperature) |
| Display | 3.5-inch resistive touchscreen |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Battery Life | ~10 hours (typical operation at 5 m/s, 20 °C) |
| Operating Environment (Body) | 5–40 °C |
| (Probe) | −20–100 °C |
| Storage Temperature | −30–60 °C |
| Weight | ~600 g |
| Dimensions (Body) | 160 × 80 × 32 mm |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Model | KA26 / KA36 |
| Velocity Range | 0.00–50.0 m/s |
| Velocity Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Temperature Range | −20.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Pressure Range | −5.00 to +5.00 kPa |
| Pressure Resolution | 0.01 kPa |
| Velocity Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Temperature Accuracy | ±0.3 °C (0.0–60.0 °C), ±0.5 °C (−20.0–0.0 °C and 60.0–100.0 °C) |
| Pressure Accuracy | ±0.1 kPa |
| Response Time | ~1 s (velocity & pressure), ~30 s (temperature) |
| Display | 3.5-inch resistive touchscreen |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Battery Life | Approx. 10 hours (at 5 m/s, 20 °C) |
| Operating Environment (Body) | 5–40 °C |
| Operating Environment (Probe) | −20–100 °C |
| Storage Temperature | −30–60 °C |
| Weight | ~600 g |
| Probe Extension | Adjustable from 260 mm to 1240 mm via telescoping rod |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA26 / KA36 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.00–50.0 m/s |
| Velocity Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Temperature Range | −20.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Pressure Range | −5.00–+5.00 kPa |
| Pressure Resolution | 0.01 kPa |
| Velocity Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Temperature Accuracy | ±0.3 °C (−20.0–0.00 °C and 60.0–100.0 °C: ±0.5 °C) |
| Pressure Accuracy | ±0.1 kPa |
| Response Time | Velocity ≈1 s, Temperature ≈30 s, Pressure ≈1 s |
| Display | 3.5-inch resistive touchscreen |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Battery Life | Approx. 10 hours (at 5 m/s, 20 °C) |
| Operating Environment (Body) | 5–40 °C |
| Operating Environment (Probe) | −20–100 °C |
| Storage Temperature | −30–60 °C |
| Weight | ~600 g |
| Probe Extendable Length | Up to 1240 mm |
| Probe Diameter | Φ10 mm (sensor), Handheld section: 260–330 mm |
| Dimensions (Body) | 160 × 80 × 32 mm |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA26 / KA36 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.00–50.0 m/s |
| Velocity Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Temperature Range | −20.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Pressure Range | −5.00 to +5.00 kPa |
| Pressure Resolution | 0.01 kPa |
| Velocity Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Temperature Accuracy | ±0.3 °C (−20.0–0.00 °C and 60.0–100.0 °C: ±0.5 °C) |
| Pressure Accuracy | ±0.1 kPa |
| Response Time | ~1 s (velocity & pressure), ~30 s (temperature) |
| Display | 3.5-inch resistive touchscreen |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Battery Life | ~10 hours (typical use at 5 m/s, 20 °C) |
| Operating Environment (Body) | 5–40 °C |
| Operating Environment (Probe) | −20–100 °C |
| Storage Temperature | −30–60 °C |
| Weight | ~600 g |
| Probe Extendable Length | up to 1240 mm |
| Probe Diameter | Φ10 mm (sensor), 40×27×125 mm (handle), 260–330 mm (adjustable) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.00–50.0 m/s |
| Velocity Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Velocity Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Temperature Range | −20.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C (0–60 °C), ±0.5 °C (−20–0 °C and 60–100 °C) |
| Pressure Range | −5.00 to +5.00 kPa |
| Pressure Resolution | 0.01 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Response Time | ~1 s (velocity & pressure), ~30 s (temperature) |
| Display | 3.5-inch resistive touchscreen |
| Data Storage | 5,000 records |
| Communication | Bluetooth 5.0, USB-C |
| Battery Life | ~10 hours (typical operation at 5 m/s, 20 °C) |
| Operating Environment (main unit) | 5–40 °C |
| (probe) | −20–100 °C |
| Storage Temperature | −30–60 °C |
| Weight | ~600 g |
| Probe Extension | Up to 1240 mm with included telescoping rod |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KA33 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–50.0 m/s |
| Resolution | 0.01 m/s (0.00–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±2% FS |
| Operating Temperature | −20 to +100 °C |
| Operating Humidity | 2.0–98.0% RH |
| Display | 3.5-inch true-color LCD with dual digital/analog readout |
| Power Supply | 6 V DC (4 × AA batteries) |
| Battery Life | Extended by 25% vs. predecessor KA22/31 |
| Probe Compatibility | Interchangeable modular probes with extendable/retractable shaft |
| Data Functions | Max/Min/Avg wind speed, threshold-based pass/fail judgment mode, real-time temperature & differential pressure measurement |