| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KA36 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.1 m/s (0.01 m/s in 0.00–9.99 m/s range) |
| Measurement Range | 0.00–50.0 m/s (air velocity), −20.0–100.0 °C (temperature), −5.00–+5.00 kPa (differential pressure) |
| Accuracy | ±3% of reading or ±0.015 m/s (whichever is greater) for air velocity |
| ±0.3 °C (−20.0–0.00 °C and 60.0–100.0 °C | ±0.5 °C) for temperature |
| Operating Temperature | −30–60 °C (storage) |
| Response Time | ~1 s (velocity & pressure), ~30 s (temperature) |
| Data Storage | 5,000 records |
| Battery Life | ~10 hours (at 5 m/s, 20 °C) |
| Weight | ~600 g |
| Dimensions (main unit) | 160 × 80 × 32 mm |
| Communication | Bluetooth 5.0, USB-C |
| Display | 3.5-inch resistive touchscreen |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KAN-1000 |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA Duct Construction Standards, GB 50243–2002 |
| Pressure Range | ±5000 Pa (adjustable) |
| Flow Measurement Range | 0.1–3000 m³/h (dependent on duct size and test configuration) |
| Data Storage | 1000 test records |
| Display | 4.7-inch capacitive touchscreen LCD |
| Environmental Operating Range | 0–40 °C, 10–90 % RH (non-condensing) |
| Interface | USB port for data export |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Certifications | CE, RoHS, ISO 9001-manufactured design |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KAN-7000 |
| Airflow Range | 100–500 m³/hr |
| Max. Cabin Static Pressure | ±2500 Pa (adjustable) |
| Standard Nozzle Diameters | Φ41 mm and Φ39 mm |
| Compliance | JIS D 1622, JIS B 8330 |
| Pressure Measurement Port | Integrated static pressure tap on flange-mounted flexible duct |
| Control Method | Inverter-driven variable-speed blower with real-time feedback loop for pressure or leakage rate setpoint control |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Measurement Principle | Piezoelectric Microbalance (QCM) |
| Particle Size Range | 0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5) |
| Concentration Range | 0.01–10.00 mg/m³ |
| Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Sampling Duration | Fixed modes (24 s, 120 s) or user-defined (10–3600 s) |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery / AC adapter (100–240 V AC) |
| Battery Life | ~4.5 h continuous operation |
| Charging Time | 5–8 h |
| Dimensions (W×L×H) | 65 × 182 × 150 mm |
| Weight | ~1.75 kg |
| Auto-Cleaning Alert | Yes (triggered upon crystal mass loading threshold exceedance) |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KD11 |
| Instrument Type | Thermal Anemometer (Integrated with Piezoelectric Dust Monitoring) |
| Resolution | 0.01 m/s (air velocity) |
| Measurement Range | Air velocity: configurable per probe (standard range 0.01–30.00 m/s) |
| Dust mass concentration | 0.01–10.00 mg/m³ |
| Accuracy | ±3% of reading (velocity) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0–100 % RH (non-condensing) |
| Particle Size Detection | 0.1–10 µm (PM₁₀ mode) |
| Sampling Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Communication Interface | RS-232C (with dedicated PC software for data download, reporting, and printout) |
| Sampling Duration Options | Fixed modes (24 s, 120 s) |
| Cleaning Alert | Automatic crystal contamination warning when deposited mass exceeds calibration threshold |
| Power Supply | Rechargeable Ni-MH battery pack |
| Battery Life | ~4.5 h continuous operation |
| Charging Time | 5–8 h |
| Dimensions | 65 × 182 × 150 mm (W × L × H) |
| Weight | ~1.75 kg |
| Brand | KANOMAX |
|---|---|
| Model | KD11+ |
| Measurement Principle | Piezoelectric Microbalance (Quartz Crystal Microbalance, QCM) |
| Particle Size Range | 0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5) |
| Concentration Range | 0.01–10.00 mg/m³ |
| Sampling Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery / AC adapter (100–240 V AC) |
| Battery Life | ~4.5 h continuous operation |
| Charging Time | 5–8 h |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0–100 % RH |
| Dimensions (W×L×H) | 65 × 182 × 150 mm |
| Weight | ~1.75 kg |
| Resolution | 0.01 m/s (for integrated anemometric function) |
| Velocity Range | Variable per probe (thermal anemometry) |
| Accuracy | ±3 % of reading |
| Sampling Duration | Programmable from 10 to 3600 s (default modes: 24 s and 120 s) |
| Auto-Cleaning Alert | Yes (triggered upon quartz crystal mass loading threshold exceedance) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Operating Principle | Tapered Element Oscillating Microbalance (TEOM™-style piezoelectric resonant frequency shift) |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤±2% |
| Particle Size Range | 0.1–10 µm (PM₁₀ mode) |
| Sample Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery or AC adapter (100–240 V AC) |
| Battery Life | ~4.5 hours continuous operation |
| Charging Time | 5–8 hours |
| Dimensions | 65 × 182 × 150 mm (W × L × H) |
| Weight | ~1.75 kg |
| Safety Classification | Non-explosion-proof |
| Compliance | Designed for occupational hygiene and environmental monitoring per ISO 7708, ISO/IEC 17025-aligned operational practices, and compatible with OSHA/NIOSH PM sampling protocols |
| Brand | Kanomax |
|---|---|
| Model | KD11 |
| Measurement Principle | Piezoelectric Microbalance (Quartz Crystal Microbalance, QCM) |
| Particle Size Range | 0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5) |
| Concentration Range | 0.01–10.00 mg/m³ |
| Sampling Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery or AC adapter (100–240 V AC) |
| Battery Life | ~4.5 hours continuous operation |
| Charging Time | 5–8 hours |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0–100 % RH |
| Dimensions (W×L×H) | 65 × 182 × 150 mm |
| Weight | ~1.75 kg |
| Sampling Duration Options | Fixed modes (24 s, 120 s) or user-defined interval (10–3600 s) |
| Auto-Cleaning Alert | Activated when crystal mass loading exceeds preset threshold |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Measurement Principle | Piezoelectric Microbalance (PMB) |
| Particle Size Range | 0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5) |
| Measurement Range | 0.01–10.00 mg/m³ |
| Sampling Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery / AC adapter (100–240 V AC) |
| Operating Time | ~4.5 h (fully charged) |
| Charging Time | 5–8 h |
| Dimensions | 65 × 182 × 150 mm (W × L × H) |
| Weight | ~1.75 kg |
| Safety Classification | Non-explosion-proof |
| Compliance | Designed for indoor/outdoor ambient air monitoring per ISO 7708, EN 481, and JIS Z 8901 dust classification frameworks |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™-style piezoelectric resonant frequency shift) |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±2% |
| Data Storage Capacity | 500 records |
| Communication Interface | RS-232C |
| Configurable Sampling Interval | 10–3600 seconds (preset options: 24 s, 120 s) |
| Cleaning Alert | Auto-notification upon crystal mass loading threshold exceedance |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | KD11 |
| Operating Principle | Tapered Element Oscillating Microbalance (TEOM™-style microgravimetric method) |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±2% |
| Data Storage Capacity | 500 records |
| Communication Interface | RS-232C |
| Sampling Duration Options | Fixed modes (24 s, 120 s) or user-defined (10–3600 s) |
| Maintenance Alert | Automatic crystal contamination warning |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6715+ |
| Resolution | 1 m³/h |
| Measurement Range | 40–4300 m³/h |
| Accuracy | ±3% of reading ±10 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Display | 3.5-inch color LCD (rotatable ±30°) |
| Data Storage Capacity | 8,000 sets |
| Power Supply | 4 × AA batteries (up to 9 h) or DC 5 V adapter |
| Weight | 3.6 kg |
| Standard Hood Size | 610 × 610 mm |
| Optional Hood Sizes | 305×1220 mm, 500×500 mm, 610×1220 mm, 800×800 mm, 800×1100 mm, 915×610 mm, 915×915 mm, 1220×1220 mm, 1400×800 mm |
| Connectivity | Bluetooth, USB, RS-232 |
| Compliance Features | Backpressure compensation, real-time clock, battery level indicator, audit-ready data logging |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Probe Model (e.g., 0.05–30 m/s for standard hot-wire probe) |
| Accuracy | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Interface | Interchangeable 8-probe modular system |
| Built-in Functions | Real-time hold, statistical calculation (mean, max, min), cross-sectional area input for volumetric flow derivation |
| Accessories | 2 m probe cable ×1, carrying case ×1, operation manual ×1 |
| Brand | Kanomax |
|---|---|
| Model | MODEL 1580-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Velocity Range | 0.01–50.0 m/s (dependent on probe) |
| Accuracy | ±2% or ±0.02 m/s (whichever is greater), ±3% for select probes |
| Operating Temperature | −10 to +60 °C |
| Operating Humidity | 0–100 %RH (non-condensing) |
| Channels | 12 simultaneous inputs |
| Communication | USB Micro-B (host PC), RS-485 serial (probe & module interconnect) |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (main unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |
| Compliance | CE, RoHS, IEC 61000-6-3/-4 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | MODEL 1580-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Channels | 12 |
| Communication | USB Micro-B / Serial |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (H×W×D) | 40 × 220 × 130 mm |
| Weight | 0.6 kg |
| Compliance | CE, RoHS |
| Brand | Kanomax |
|---|---|
| Model | 1580-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Channels | 12 simultaneous |
| Probe Compatibility | 15 interchangeable probe types |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (Unit) | 220 × 130 × 40 mm |
| Weight (Unit) | 0.6 kg |
| Communication | USB Micro-B, RS-485 serial |
| Software | Windows 10-compatible, multilingual (EN/JP/CN), real-time 144-channel data logging capability |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Channels | 12-channel simultaneous acquisition |
| Probe Compatibility | 15 interchangeable probe models |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Dimensions (Main Unit) | 220 × 130 × 40 mm |
| Weight (Main Unit) | 0.6 kg |
| Communication | USB Micro-B, RS-485 serial interface |
| Software | Windows 10-compatible, tri-lingual (English/Chinese/Japanese), real-time data logging and visualization |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 2212 |
| CO Range | 0–500 ppm, Accuracy: ±3% of reading or ±3 ppm (whichever is greater) |
| CO₂ Range | 0–5000 ppm, Accuracy: ±3% of reading |
| Temperature Range | −20 to +60 °C, Accuracy: ±0.5 °C |
| Relative Humidity Range | 2–98% RH, Accuracy: ±2% RH (2–80% RH), ±3% RH (80–98% RH) |
| Data Storage | 1500 sets with min/max/avg statistics |
| Interface | USB |
| Output | 0–1 V analog (optional) |
| Power | 6 × AA batteries or optional AC adapter |
| Weight | 400 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | 2212 |
| Price | ¥25,000 CNY |
| CO Range | 0–500 ppm |
| CO Accuracy | ±3% of reading or ±3 ppm (whichever is greater) |
| CO₂ Range | 0–5000 ppm |
| CO₂ Accuracy | ±3% of reading |
| Temperature Range | −20 to +60 °C (−4 to +140 °F) |
| Temp Accuracy | ±0.5 °C (±1 °F) |
| Humidity Range | 2–98 %RH |
| RH Accuracy | ±2 %RH (2–80 %RH), ±3 %RH (80–98 %RH) |
| Data Storage | 1500 sets |
| Communication Interface | USB |
| Analog Output | 0–1 V (optional) |
| Power Supply | 6 × AA batteries or AC adapter (optional) |
| Weight | 400 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 2212 |
| CO Range | 0–500 ppm |
| CO₂ Range | 0–5000 ppm |
| Temperature Range | −20 to +60 °C |
| Relative Humidity Range | 2–98 %RH |
| CO Accuracy | ±3% of reading or ±3 ppm (whichever is greater) |
| CO₂ Accuracy | ±3% of reading |
| Temp Accuracy | ±0.5 °C |
| RH Accuracy | ±2 %RH (2–80 %RH), ±3 %RH (80–98 %RH) |
| Data Storage | 1500 records |
| Interface | USB |
| Output | 0–1 V analog (optional) |
| Power | 6 × AA batteries or AC adapter (optional) |
| Weight | 400 g |
| Brand | KANOMAX |
|---|---|
| Origin | China (Liaoning) |
| Model | 3000-0C+ |
| Instrument Type | Online Fit Testing System |
| Flow Rate | Sampling Flow 100 cm³/min |
| Particle Size Range | 0.02–1.0 µm |
| Concentration Range | 0–100,000 particles/cm³ |
| Fit Factor Calculation Method | Direct Cout/Cin Ratio |
| Test Agent | Isopropanol or Ethanol (≥99.5% purity) |
| Display | 7-inch TFT color touchscreen |
| Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Data Interface | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Report Format | Microsoft Excel (.xlsx) |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −20–50 °C, 0–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm (W×H×D) |
| Weight | 2.3 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Instrument Type | Aerosol-Based Quantitative Fit Tester |
| Particle Detection Method | Condensation Particle Counter (CPC) |
| Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Concentration Range | 0–100,000 particles/cm³ |
| Fit Factor Calculation | Direct Cout/Cin Ratio |
| Challenge Agent | ≥99.5% purity isopropanol or ethanol |
| Display | 7-inch full-color touchscreen |
| Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.1, HSE INDG479, GB 2626–2019, GB 19083–2010, GB/T 32610–2016 |
| Data Interface | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Report Output | Microsoft Excel format |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −20–50 °C, 0–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm (W×H×D) |
| Weight | 2.3 kg |
| Accessories Included | Isopropanol reagent kit, sealing cap, reagent rod, zero-count filter, mesh filter, sampling tube, user manual, AC adapter, stylus, USB cable, Ethernet cable, software DVD, USB flash drive |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Volume Range | 20–6000 L |
| Sampling Duration | Up to 7 h (battery operation) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Principle | Andersen Impaction (6-stage cascade impactor) |
| Impact Velocity | <20 m/s |
| Exhaust Filtration | ISO Class 3 certified filter |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| User Management | 64 configurable users with multi-level permissions and audit trail |
| Remote Control | IR remote (supports up to 5 units simultaneously) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Volume Range | 20–6000 L |
| Sampling Time Range | Up to 7 h (battery operation) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Principle | Andersen Impaction (6-stage cascade impactor) |
| Impact Velocity | <20 m/s |
| Exhaust Filtration | ISO Class 3 HEPA filter integrated |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV format) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Sample Support | 90–100 mm or 55–84 mm Petri dishes |
| User Management | 64 configurable users with multi-level permission control and audit trail |
| Remote Control | Infrared remote (supports up to 5 units simultaneously) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Sampling Principle | Andersen Impaction |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Battery Runtime | 7 h |
| Sampling Volume Range | 20–6000 L |
| Sampling Interval | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Cycle Count | 2–300 cycles or continuous |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Display | 4.3-inch color touchscreen |
| Communication | USB, RS-485 (Modbus RTU) |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Alarm | Visual & audible flow deviation alert |
| Exhaust Filtration | Integrated ISO Class 3 filter |
| Sampling Head Material | 316 stainless steel |
| Compatible Petri Dishes | 90–100 mm or 55–84 mm |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Sampling Principle | Andersen Impaction |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Volume Range | 20–6000 L |
| Sampling Duration | Up to 7 h on battery |
| Display | 4.3-inch color touchscreen |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| Impactor Stages | 6-stage Andersen design |
| Impact Velocity | <20 m/s |
| Exhaust Filtration | ISO Class 3 HEPA filter |
| Culture Dish Compatibility | 90–100 mm and 55–84 mm Petri dishes |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| User Management | 64 editable users with multi-level permissions and audit trail |
| Remote Control | IR remote (supports up to 5 units simultaneously) |
| Language Support | English, Japanese, Chinese |
| Alarm System | Visual & audible alerts for flow deviation, low battery, door open, filter saturation |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Battery Runtime | 7 h |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS485 (Modbus RTU) |
| Sample Volume Range | 20–6000 L |
| Sampling Interval | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Sampling Cycles | 2–300 or continuous |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| Exhaust Filter Class | ISO Class 3 |
| Power Supply | Li-ion rechargeable battery + AC adapter (100–240 V) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Battery Runtime | 7 h |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Sample Volume Range | 20–6000 L |
| Sampling Interval | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Sampling Cycles | 2–300 or continuous |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| Exhaust Filter Class | ISO Class 3 |
| Power Supply | Li-ion rechargeable battery + AC 100–240 V adapter |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Duration | Up to 7 h (battery) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Volume Range | 20–6000 L |
| Time Interval Setting | 10 s–1 h |
| Delay Start | 0 s–23 h 59 min 59 s |
| Cycle Count | 2–300 cycles or continuous mode |
| Culture Dish Compatibility | 90–100 mm and 55–84 mm Petri dishes |
| Exhaust Filtration | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Time Range | 10 s to 1 h |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Principle | Andersen Impaction |
| Impactor Stages | 6-stage |
| Impact Velocity | <20 m/s |
| Sample Volume Range | 20–6000 L |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery (7 h runtime) + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Alarm | Visual & audible flow anomaly alert |
| Exhaust Filtration | Integrated ISO Class 3 filter |
| Sampling Head Material | 316 stainless steel |
| Language Support | English, Japanese, Chinese |
| Optional Accessories | Tripod, high-pressure gas sampling kit, thermal printer |