Environmental Monitoring Instruments
Filter
Showing 7531–7560 of 9029 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | 111 / 1160 |
| Flow Rate | 1–20 L/min |
| Output Pressure | 10–60 psi |
| Dew Point | −10 °C (membrane dryer) / −40 °C (heatless dryer) |
| Purity | SO₂ < 0.1 ppb, NO < 0.1 ppb, NO₂ < 0.1 ppb, O₃ < 0.4 ppb, H₂S < 0.1 ppb, NH₃ < 0.1 ppb, CO (optional) < 0.02 ppm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | 42i Series |
| Detection Principle | Chemiluminescence |
| Measurement Range | 0–100 ppm (NO/NO₂/NOₓ) |
| LOD | 0.40 ppb (60-s average) |
| Zero Noise | 0.20 ppb RMS |
| 24-hr Zero Drift | < 0.40 ppb |
| 24-hr Span Drift | ±1% of full scale |
| Response Time | < 5 s |
| Operating Modes | Dual-range, Auto-ranging, NO-only, NOₓ-only, or simultaneous NO/NO₂/NOₓ output |
| Calibration | Independent calibration for NO, NO₂, and NOₓ |
| Environmental Correction | Integrated temperature & pressure compensation |
| Connectivity | Ethernet interface with remote access capability |
| Display | High-resolution LCD with customizable soft keys |
| Data Storage | Flash-based memory with extended capacity |
| Compliance | Designed to meet EPA Performance Specification 1 (PS-1), EN 14211, ISO 7935, and supports GLP/GMP audit trails per FDA 21 CFR Part 11 requirements |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 43i |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 450i |
| Instrument Type | Online Gas Analyzer |
| Target Analyte | Hydrogen Sulfide (H₂S) |
| Response Time (T₉₀) | 80 s |
| Measurement Accuracy | ±1% of reading or ±1 ppb (whichever is greater) |
| Measurement Ranges | 0–0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10 ppm |
| Extended Ranges | 0–0.5, 1, 2, 5, 10, 20, 50, 100 ppm |
| Mass Concentration Ranges | 0–0.2, 0.5, 1, 2, 5, 10, 25 mg/m³ and 0–2, 5, 10, 20, 50, 100, 200, 250 mg/m³ |
| Zero Noise | 1.0 ppb RMS (60-s averaging) |
| Limit of Detection (LOD) | 2.0 ppb (60-s averaging) |
| Zero Drift (24 h) | <1 ppb |
| Span Drift (24 h) | ±1% of full scale |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 51i |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–1 to 0–10,000 ppmC |
| LOD | 0.050 ppmC (10-sec avg) |
| Zero Drift (24h) | <0.50 ppmC |
| Span Drift (24h) | <2% of full scale or 0.20 ppmC (whichever is greater) |
| Response Time (90%) | 15 sec (1-sec avg) |
| Accuracy | ±2.0% of reading or ±0.1 ppmC (whichever is greater) |
| Linearity | ±2% of span (10–150% of full scale) |
| Sample Flow Rate | 0.75–1.50 L/min |
| Combustion Air Flow | 150–300 mL/min |
| Zero Air (HC-free) Flow | 10–35 mL/min (H₂) or 50–120 mL/min (H₂/He mixture) |
| Operating Temperature | 15–35 °C |
| Power | 100/115/220–240 VAC ±10%, 50/60 Hz, 420 W |
| Dimensions (W×H×D) | 425 × 219 × 584 mm |
| Weight | 22.7 kg |
| Outputs | Isolated 0–20 mA / 4–20 mA (optional), RS232/RS485, TCP/IP Ethernet, 10 status relays, power-fail alarm |
| Inputs | 16 digital inputs (standard), 8 analog inputs (0–10 VDC, optional) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Low-Concentration CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Parameters | SO₂, NOₓ, Particulate Matter (PM), Hg, NH₃ |
| Integrated with Thermo Fisher Analyzers | 43i (SO₂), 42i (NOₓ), 48i (CO), 410i (CO₂), 17i (NH₃), PM CEMS, Mercury Freedom™ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Orion 8006cX Online COD Analyzer |
| Instrument Type | Online Analyzer |
| Measurement Range | 0–1000 mg/L and 1000–5000 mg/L |
| LOD | 10 mg/L |
| Chloride Interference Tolerance | up to 5000 mg/L |
| Compliance | HJ/T 399–2007, HJ 377–2019, HJ 35X–2019 |
| Certification | CCEP (China Environmental Protection Product Certification) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Dual-Channel Ion Concentration and pH Meter |
| Model | D10P-20 |
| Ion Measurement Range | 0–19999 (in user-selectable units: ppm, mg/L, M, %, or unitless) |
| Detection Limit | 0.1 ppm Ca²⁺ (as specified with 9720BNWP electrode) |
| Response Time | <30 s (t₉₀, typical for ISE in stirred aqueous samples) |
| Measurement Accuracy | ±0.1 mV or ±0.05% of reading (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Electrode Compatibility | Orion 9720BNWP Calcium ISE, 927007MD ATC probe |
| Compliance | GLP-compliant data logging, CE, CSA, UL, TÜV, FCC Class A, IP54 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | D10P-70 |
| Pricing | Available Upon Request |
| Electrode | 9770BNWP Free Chlorine Sensor |
| Measurement Range (Cl₂) | 0.01–20 ppm |
| Detection Limit | 3 × 10⁻⁷ M |
| pH Range | 0–14 |
| Temperature Range (Continuous) | 0–50 °C |
| Temperature Range (Intermittent) | 50–100 °C |
| Repeatability | ±2% |
| Electrode Slope | 28 ± 2 mV/decade |
| Electrode Dimensions | 110 mm length, 12 mm body diameter, 16 mm cap diameter |
| Cable Length | 1 m |
| Dual Channel Capability | pH + ISE (e.g., Cl₂, NH₄⁺, F⁻, Na⁺, K⁺, Br⁻, NO₃⁻) |
| Ion Concentration Range | 0–19999 (units: ppm, mg/L, M, %, or unitless) |
| Resolution | 1–3 significant digits |
| Accuracy (Ion) | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105 °C |
| Temp Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Interfaces | Dual BNC, Dual Reference, Dual MiniDIN (for ATC probes) |
| Methods Stored | 20 |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes (audit trail, user password, method-level security) |
| Connectivity | RS232 (bidirectional), optional USB cable |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 × 17.0 × 22.4 cm (H × W × L) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Dual Star |
| Instrument Type | Multi-Ion Analyzer |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–6 |
| Auto-Buffer Recognition | US, NIST, DIN, and User-Defined |
| Ion Concentration Range | 0–19999 |
| Ion Resolution | 1–3 Significant Digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Units | ppm, mg/L, M, %, or unitless |
| Measurement Modes | Single or Dual Standard Addition/Standard Subtraction |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Temp Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Input Interfaces | Two BNC, Two Reference Electrode, Two MiniDIN (for temperature probes) |
| Method Storage | 20 methods |
| Password Protection | Yes |
| Data Storage | 1000 readings |
| GLP Compliance | Yes |
| Data Interface | Bidirectional RS232, optional USB cable |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| Power Supply | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 420D-01A |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence-based (RDO) and Polarographic DO |
| pH Range | −2.000–20.000 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration Points | Up to 5 |
| mV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| DO Concentration (RDO) | 0–50 mg/L |
| DO Accuracy (RDO) | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% of reading (20–50 mg/L) |
| DO Saturation | 0–500% |
| Saturation Accuracy | ±2% |
| Temperature Range | −5 to 105 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.1 °C |
| Data Storage | 5000 GLP-compliant entries |
| Protection Rating | IP67 (portable unit) |
| Interface | USB, RS232 |
| Power | 4×AA batteries or AC adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | Star A211 |
| Price | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | A213 (Benchtop), A223 (Portable) |
| Measurement Principle | Electrochemical (Galvanic Cell) and Optical (RDO Fluorescence) |
| DO Range | 0–90 mg/L (Galvanic), 0–50 mg/L (RDO) |
| Accuracy | ±0.2 mg/L (Galvanic) |
| Saturation Range | 0–600% (Galvanic), 0–500% (RDO) |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Temperature Range | 0–50 °C |
| Resolution | 0.01/0.1 mg/L |
| Data Storage | 2000 entries (A213), 1000 entries (A223), GLP-compliant |
| Interface | RS232, USB |
| Power | AC adapter (100–240 V AC) or 4 × AA batteries |
| IP Rating | IP54 (A213), IP67 (A223) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | A214, A324 |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Modules | pH/Temp, pH/ISE/Temp, pH/LogR/Temp, Conductivity/Temp, DO/Temp |
| Data Storage | 2000–5000 entries (GLP-compliant) |
| Display | Full-color LCD with multi-parameter overlay |
| Connectivity | Dual USB + RS232 |
| Protection Rating | IP54 (benchtop), IP67 (portable A329) |
| Power Options | AC adapter (90–260 V AC) or 4×AA batteries |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Category | Imported Instrument |
| Model | Star A215 |
| Price | Upon Request |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration | 1–5 points, NIST/US, DIN, and user-defined buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| DO Range | 0.00–90.0 mg/L (0.0–600% saturation) |
| DO Resolution | 0.01 mg/L / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| DO Calibration | Air-saturated water, water-saturated air, Winkler titration, zero-point |
| Sensor Type | Polarographic membrane electrode |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Connectivity | Dual-mode RS232, optional USB cable |
| Input Interfaces | pH (BNC), temperature (miniDIN), stirrer (phono-jack, benchtop only) |
| Data Logging | 750 measurements |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 independent user profiles |
| Power | 4×AA alkaline batteries (up to 2000 h portable operation) or universal AC adapter (benchtop) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Environmental Rating | Benchtop IP54 (dust- and splash-resistant) |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | A216 (Benchtop) / A326 (Portable) |
| Instrument Type | Laboratory |
| pH Range | −2.000 to 20.000 |
| pH Accuracy | ±0.001 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| mV Range | ±2000.0 mV |
| mV Accuracy | ±0.1 mV |
| DO Measurement Principle | Polarographic or Luminescent (RDO) |
| Polarographic DO Range | 0–90 mg/L (±0.2 mg/L accuracy) |
| RDO DO Range | 0–50 mg/L (±0.1 mg/L @ 0–8 mg/L |
| DO Saturation Range | 0–600% (Polarographic) / 0–500% (RDO) |
| DO Saturation Accuracy | ±2% |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Temperature Range | 0–50 °C |
| Temp Accuracy | ±0.1 °C |
| Data Storage | 2000 entries (A216) / 5000 entries (A326), with timestamp, sample ID, user ID, and calibration metadata |
| Compliance | GLP-compliant data logging, FDA 21 CFR Part 11-ready audit trail support via optional software |
| Enclosure Rating | IP54 (A216), IP67 (A326) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Models | 8157BNUMD (Refillable), 8107BNUMD (Low-Maintenance) |
| pH Range | 0–14 |
| pH Accuracy | ±0.03 pH (with ATC) |
| pH Precision | ±0.01 pH |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1.0 °C |
| Reference System | ROSS™ Double-Junction |
| Internal Reference | ROSS™ Liquid Junction |
| Isopotential Point | pH 7 |
| Fill Solution (Refillable) | 3 M KCl |
| Body Material | Epoxy Resin |
| Electrode Length | 120 mm |
| Diameter | 12 mm |
| Compatible Meters | Orion Star™, Aplus™, and PerpHecT® Series |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | VERSA STAR |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | pH, ISE (Ion Selective Electrode), Conductivity, Dissolved Oxygen (DO), Temperature |
| Compliance | GLP-Compliant Data Storage (2000 Records) |
| Connectivity | Dual USB + RS232 |
| Protection Rating | IP54 |
| Operating Modules | Up to 4 Simultaneous Modules |
| Stirrer Support | 2 Orion Star Stirrers (Hot-Swappable) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | Partisol |
| Typical Configuration | Total Suspended Particulates (TSP) Sampler |
| Flow Range | Not Specified |
| Vacuum Pressure Capability | Not Specified |
| Flow Stability | Not Specified |
| Maximum Flow Error | Not Specified |
| Operational Duration at High Flow & High Backpressure | Not Specified |
| Service Life at Maximum Flow & Backpressure | Not Specified |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Custom Configuration Available |
| Pricing | Upon Request |
| Instrument Type | Radiation Survey Meter / Dose Rate Meter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | RDO Pro |
| Price | Upon Request |
| Measurement Principle | Fluorescence Lifetime Quenching |
| Range | 0–20 ppm / 0–200% saturation |
| Resolution | 0.01 ppm (<10 ppm), 0.1 ppm (≥10 ppm) |
| Accuracy | ±0.1 ppm (<8 ppm), ±0.2 ppm (8–20 ppm) |
| Response Time | t₉₀ = 30 s, t₉₅ = 37 s |
| Units | ppm, % saturation, °C, °F |
| Calibration | Single-point air-saturation calibration |
| Compensation | Automatic temperature, barometric pressure, and salinity compensation |
| Operating Temperature | 0–50 °C |
| Max Pressure Rating | 300 PSIG (20.7 bar) at 50 °C |
| Flow Independence | Yes |
| Housing Materials | Delrin®, Polystyrene |
| Probe Dimensions | 203 mm length × 47 mm diameter |
| Threaded Mount | 1.25" NPT |
| Warranty | 2 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405-DF |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅, and PMₜₕₒᵣₛₑ (coarse particulate matter) |
| Compliance | U.S. EPA Equivalent Method EQPM-0609-182 |
| Operating Temperature Range | −40 °C to +60 °C (sample gas) |
| Flow Rates | Fine channel: 3.0 L/min |
| Coarse channel | 1.67 L/min |
| Bypass | 12.0 L/min |
| Mass Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Data Output Interval | Configurable from 10 sec to 24 hr |
| Internal Memory | 500,000 records |
| Analog Outputs | 8 user-defined (0–1 V or 0–5 V DC) |
| Digital Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Power | Main unit: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 137.8 in |
| Weight | 38 kg |
| Safety Certifications | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | TLD 3500, TLD 5500, TLD 6600 |
| Instrument Class | Radiation Dosimetry Reader |
| Portability | Portable (TLD 3500), Benchtop Automated (TLD 5500), Fully Automated Floor-Standing System (TLD 6600) |
| Radiation Types Measured | Beta (β⁻), Photons (X-ray, γ), Neutrons (via converter foils) |
| Detector Compatibility | LiF:Mg,Ti (TLD-100), LiF:Mg,Cu,P (TLD-100H), CaF₂:Dy, CaSO₄:Dy, Al₂O₃:C (for OSL-compatible variants), and custom geometries (ribbons, rods, chips, powders) |
| Heating Method | Resistive (TLD 3500), Hot-Gas Convection (TLD 5500), Nitrogen-Heated Non-Contact (TLD 6600) |
| Max Heating Temperature | 600 °C |
| Readout Sensitivity | ≤1 µGy (LiF-based elements, typical) |
| Calibration Traceability | NIST-traceable, compliant with ANSI N13.11, N13.32, N545 |
| Software Platform | WinREMS v5.x (data acquisition, QA/QC logging, audit trail), WinAlgorithms v3.x (dose conversion per ICRP 74, ISO 4037, IEC 62387) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TVA Series |
| Instrument Type | Portable Real-Time Gas Analyzer |
| Typical Configuration | Dual FID & PID Detector |
| Detection Range (FID) | 1–50,000 ppm (methane equivalent) |
| Detection Range (PID) | 0.5–2,000 ppm (isobutylene equivalent) |
| Resolution | <100 ppb (PID), <300 ppb (FID) |
| Accuracy | ±25% of reading or ±2.5 ppm (whichever is greater), per EPA Method 21 calibration protocols |
| Response Time (T90) | ≤3.5 s (both detectors) |
| Operating Temperature | 0–40 °C |
| Weight | ~5 kg |
| Certifications | FM Class I, Division 1 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | VFC-PM10 |
| Typical Configuration | PM₁₀ Inhalable Particulate Sampler |
| Flow Rate | 40 ACFM (1.13 m³/min) |
| Flow Accuracy | < ±1% deviation over 24 h |
| Motor | 1.0 HP, 7 A, 840 W |
| Power Supply | 110 V AC, single-phase, 60 Hz (optional configurations available) |
| Weight | 62 kg (total system) |
| Dimensions | Cabinet: 129 cm H × 56 cm W × 56 cm D (22 kg) |
| PM₁₀ Cyclone | 81 cm H × 81 cm W × 63.5 cm D (25 kg) |
| VFC Fan & Filter Holder Assembly | 71 cm H × 53 cm W × 48 cm D (12 kg) |
| Flow Control Principle | Critical-flow Venturi with aerodynamic energy recovery |
| Compliance | U.S. EPA Reference Method RFPS-1287-063 for PM₁₀ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Pro |
| Detection Principle | Gas Chromatography-Mass Spectrometry (GC-MS) Coupled Online Sampling |
| Instrument Type | Continuous Online Analyzer |
| Typical Configuration | Multi-Channel VOC Monitoring System |
| Detection Range | 0.01–1 ppm (v/v) |
| Resolution | Dual Slit Selection — 60 (1 mm slit), 20 (4 mm slit) |
| Accuracy | <0.1% relative error |
| Response Time | ≤15 min for up to 100 sampling points |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Sentinel Pro |
| Detection Principle | Gas Chromatography-Mass Spectrometry (GC-MS) Coupled Online Sampling |
| Instrument Category | Online Real-Time Analyzer |
| Typical Configuration | Multi-Channel VOC Monitoring System |
| Detection Range | 0.01–1 ppm (v/v) |
| Resolution | Dual-Slit Selector — 60 (1 mm slit), 20 (4 mm slit) |
| Accuracy | <0.1% relative precision |
| Response Time | ≤15 min for up to 100 sampling points |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Models | SGS I, SGS II |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Portability | Portable |
| Measured Radiation Types | Gamma (γ) and Neutron (n) |
| Detector Configuration | Dual plastic scintillator gamma detectors |
| Gamma Sensitivity | 500 cps/μR/h |
| Neutron Detection | He-3 proportional counter (3 atm) |
| Operating Temperature | –20 °C to +50 °C |
| Compliance | IAEA TS-G-1.2, ITRAP+10, ANSI N42.35-2019 |
| Data Storage | 1300 measurement records |
| Communication | RS-485 (to detectors), RS-232 (to PC) |
| Alarm Logic | Dual-threshold per channel, configurable alarm levels |
| Gamma Detector Volume (SGS I) | 50 L total (2 × 25 L) |
| Gamma Detector Volume (SGS II per 1500 GN unit) | 25 L |
| Neutron Detection Limit (SGS II, 10 s, 2 m, 252Cf) | 20,000 n/s |
| Gamma Detection Limit (SGS II) | <100 nSv/h (background 200 nSv/h) |
| Detection Probability | >99.9% |
| False Alarm Rate | <1 per 10,000 measurements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | STRIDE |
| Instrument Category | Radiation Dose Rate Meter |
| Instrument Form Factor | Portable |
| Measured Medium | Radioactive Materials on Personnel or Vehicles |
| Detector Type | High-Sensitivity NaI(Tl) Scintillation Detector with Optional He-3 Neutron Detector and GM Tube |
| Measurement Mode | Portal-Based Screening |
| Nuclide Identification Time | 20–30 seconds (dependent on nuclide type, activity, background radiation level, and shielding) |
| Sensitivity | High |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | TPM-903B |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Instrument Type | Online, Real-Time Portal Monitor |
| Measured Medium | Gamma-emitting Radionuclides (e.g., Cs-137, Co-60) |
| Detector Type | Dual BC408 Plastic Scintillation Detectors |
| Detection Application | Rapid Personnel Screening & Emergency Radiological Incident Response |
| Sensitivity | ≤1 mCi RDA (Reference Dispersal Activity) for Cs-137 at 25 µR/h background, 1-second transit time |
| Shielding | Full-perimeter 1.6 mm lead lining |
| Transit Speed | One-second dwell time per individual |
| Operating Temperature | −20 °C to +50 °C |
| Portable Case Dimensions | 231 cm × 93 cm × 61 cm |
| Portable Case Weight | 40 kg |
