Environmental Monitoring Instruments
Filter
Showing 7651–7680 of 9029 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AquaPro Five-Parameter System |
| Instrument Type | Online Monitor |
| Temperature Range | –5 to 95 °C |
| pH Range | 0.00–14.00 pH |
| Dissolved Oxygen Range | 0.00–20.00 ppm (0–50 °C) |
| Conductivity Range | 0–2000 µS/cm |
| Turbidity Range | 0–4000 NTU (–5 to 50 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AquaPro RDO |
| Instrument Category | Online Dissolved Oxygen Analyzer |
| Measurement Principle | Fluorescence Quenching |
| Range | 0–20 ppm / 0–200% saturation |
| Accuracy | ±0.1 ppm (≤8 ppm), ±0.2 ppm (8–20 ppm) |
| Repeatability | ±5% |
| Detection Limit | 0.01 ppm or 0.1% saturation |
| Maintenance Interval | Fluorescence Cap Replacement Every 2 Years |
| Certification | CE Marked |
| Regulatory Compliance | Designed for compliance with ISO 5814:2012 (Water quality — Determination of dissolved oxygen — Electrochemical probe method), ASTM D888-22 (Standard Test Methods for Dissolved Oxygen in Water), and supports GLP/GMP data integrity requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AquaPro |
| Instrument Category | Online Water Quality Analyzer |
| Measurement Flexibility | Configurable Input Channels for Any Parameter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific AquaPro |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | DataStick Digital Sensor |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AquaSensors |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AquaTurb / AquaSol |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Turbidity, Suspended Solids (SS) Concentration |
| Optical Method | ISO 7027-compliant Nephelometric & Backscatter Detection |
| Light Source | Infrared LED (850 nm) |
| Detection Angles | 90° and 180° |
| Output | Digital (RS-485, Modbus RTU), Optional 4–20 mA Analog |
| Temperature Compensation | Integrated Pt1000 sensor |
| Enclosure Rating | IP68 |
| Cleaning Option | Optional Automatic Wiper or Air-Pulse Self-Cleaning Module |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM-1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10 / PM2.5 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | In-situ dilution sampling with wet-gas analysis |
| Compliance | EPA Reference Method 10, ASTM D6522, ISO 12039, EN 14181, US EPA PS-11 & PS-2 |
| Certifications | ISO 9001, China National Environmental Protection Agency (MEP) Certification, China National Technical Supervision Bureau Certification |
| Calibration | Full-system dynamic calibration (probe-to-analyzer) per EPA requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CEMS Hg |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ChemComb 3500 |
| Configuration | Integrated Multi-Phase Sampling Cartridge |
| Flow Rate | 10 L/min (PM₂.₅/PM₁₀ mode) |
| Diffusion Tube Material | Borosilicate Glass |
| Diffusion Tube Dimensions | Ø47 mm × 38 mm, ~212 hexagonal channels per unit, channel side length ≈ 2 mm, internal surface area ≈ 775 cm² |
| Filter Format | Four-stage 47 mm filter holder (PTFE construction) |
| Inlet Options | Anodized Aluminum or PTFE-coated PM₂.₅ (10 & 16.7 L/min) and PM₁₀ (10 L/min) cyclones |
| Organic Sorbent Stages | Optional PUF and/or XAD-2 resin beds downstream of filters |
| External Diameter (excl. clamps) | 7.49 cm |
| External Diameter (incl. clamps) | 9.68 cm |
| Length (inlet to 1/4″ quick-connect outlet) | 28.27 cm |
| Weight (empty) | 1.23 kg |
| Weight (with two diffusion tubes) | 1.45 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Dilution |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±0.5% of full scale (typical for certified dilution CEMS per EPA PS-2 and ISO 14956) |
| Repeatability | <0.3% RSD (under stable operating conditions) |
| Response Time (T90) | <120 s for SO₂ and NOₓ |
| Long-Term Stability | <1% drift over 7 days (with daily system calibration) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Thermo Scientific DM5018 |
| Measurement Principle | Beta-ray Attenuation |
| Measured Parameters | TSP / PM₁₀ / PM₂.₅ |
| Measurement Range | 0–10 mg/m³ |
| Sampling Flow Rate | 16.67 L/min |
| Detection Limit | <4 µg/m³ (1-hr avg), <1 µg/m³ (24-hr avg) |
| Flow Stability | ±2% of reading |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Environmental & Process Instruments |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Price Range | USD 70,000 – 140,000 |
| Measurement Accuracy | Not Specified |
| Repeatability | Not Specified |
| Response Time | Not Specified |
| Long-Term Stability | Not Specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EPD-G |
| Instrument Category | Dose/Dose Rate Meter |
| Instrument Type | Portable |
| Measured Radiation | X-ray and Gamma (γ) Radiation |
| Detector Type | Multi-stage Solid-State Detector |
| Dose Equivalent Range | 1/64 µSv to 16 Sv |
| Dose Rate Range | 1/64 µSv/h to 16 Sv/h |
| Accuracy | ±10% (referenced to Cs-137, 662 keV) |
| Energy Response | 15 keV – 10 MeV |
| Power Supply | Two AA 1.5 V alkaline batteries (8 weeks continuous operation) or one 3.6 V lithium battery (5 months continuous operation) |
| Data Retention | 10 years without power |
| Memory Capacity | Adjustable logging interval down to 1 s |
| Security | Password-protected data storage area |
| Compliance | Designed for use in accordance with IEC 61526:2010 (Radiation protection instrumentation — Measurement of personal dose equivalents Hp(10) and Hp(0.07) for X, gamma, neutron and beta radiations) and meets requirements for routine occupational monitoring under ISO 4037 and ANSI N42.20 |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FGD-CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Dilution Extraction with UV/IR Absorption and Paramagnetic/O2 Electrochemical Detection |
| Key Parameters | SO₂, NOₓ, CO, O₂, Flow Rate, Temperature, Static Pressure, Particulate Matter (PM), Relative Humidity, Total Reduced Sulfur (TRS), H₂S |
| Compliance Framework | EPA Performance Specifications (PS-2, PS-3, PS-5, PS-15), EN 15267, ISO 14001, US EPA Method 6C, Method 7E, Method 10, Method 3A, ASTM D6522, ASTM D5197 |
| Data Integrity | 21 CFR Part 11–compliant audit trail, GLP/GMP-ready reporting |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific FH62C14 |
| Measurement Principle | Beta Ray Attenuation |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Range | 0–5,000 µg/m³ or 0–10,000 µg/m³ (selectable) |
| LOD | 4 µg/m³ (1-hr avg), 1 µg/m³ (24-hr avg) |
| Flow Rate | 1 m³/h (16.7 L/min) |
| Radioisotope | ¹⁴C sealed source in BaCO₃ matrix |
| Activity | <3.7 MBq (<100 µCi), exempt under U.S. NRC regulations |
| Data Storage | >1 year of half-hourly mass concentration averages |
| Flow Mode Options | Standard temperature & pressure (STP) or actual ambient flow |
| Interference Compensation | Automatic correction for ambient radioactivity |
| Environmental Robustness | Immune to vibration and diurnal temperature fluctuations |
| Communication | Dual RS-232 serial ports for remote control and data export |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | FH62C14 |
| Measurement Method | Beta-Ray Absorption |
| Measured Parameter | PM2.5 |
| Radioisotope Source | Carbon-14 (¹⁴C) |
| Activity | <3.7 MBq (<100 μCi) |
| Measurement Range | 0–5000 μg/m³ or 0–10000 μg/m³ |
| LOD (24-h avg) | <1 μg/m³ |
| LOD (1-h avg) | <4 μg/m³ |
| Accuracy | ±2 μg/m³ (24-h) |
| Resolution | ±1 μg/m³ (instantaneous) |
| Correlation Coefficient | R > 0.98 |
| Sampling Flow Rate | 1 m³/h (16.67 L/min), adjustable 0–20 L/min via built-in critical orifice |
| Operating Temperature | −30 °C to +60 °C |
| Data Averaging Intervals | 0.5, 1, 3, and 24 hours |
| Storage Capacity | >1 year of half-hourly averages |
| Communication Interfaces | Dual RS-232 serial ports |
| Analog Outputs | 4–20 mA or 0–10 V |
| Power Supply (Analyzer) | 100–240 VAC, 50/60 Hz, 15 W |
| Power Supply (Pump) | 220–240 VAC, 50/60 Hz, 100 W |
| Dimensions (Analyzer) | 483 mm (W) × 311 mm (H) × 330 mm (D) |
| Weight (Analyzer) | 22.5 kg |
| Dimensions (Pump) | 210 mm (W) × 222 mm (H) × 108 mm (D) |
| Weight (Pump) | 8.16 kg |
| Regulatory Certifications | U.S. EPA and California Air Resources Board (CARB) equivalency for PM₂.₅ and PM₁₀ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific GM-5000 |
| Measurement Principle | Optical Scattering (for PM), Electrochemical (for SO₂, NO₂, NO, CO), Photoionization Detection (for TVOC), UV Absorption (for O₃) |
| Measured Parameters | PM₂.₅, PM₁₀, SO₂, NO₂, NO, O₃, CO, TVOC |
| Measurement Range | PM₂.₅ / PM₁₀: 0–1500 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 0–500 ppb |
| CO | 0–50 ppm |
| TVOC | 0–40 ppm |
| Sampling Interval | 10 s |
| Sample Flow Rate | >1.5 L/min |
| Detection Limits | PM₂.₅ / PM₁₀ <1.0 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 5 ppb |
| CO | 0.02 ppm |
| TVOC | 5 ppb |
| Flow Stability | ±2.5% of full scale (all sensors) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | GM-5000 |
| Instrument Type | Online Fixed-Station Monitor |
| Measured Gases | NO₂, SO₂, O₃, CO |
| Response Time (T90) | 120 s (all sensors) |
| Measurement Accuracy | ±10 ppb (gaseous pollutants) |
| Measurement Ranges | NO₂: 0–20 ppm |
| SO₂ | 0–50 ppm |
| O₃ | 0–20 ppm |
| CO | 0–500 ppm |
| PM₂.₅ | 0–1500 µg/m³ |
| PM₁₀ | 0–1500 µg/m³ |
| Detection Limits (2σ) | NO₂: 30 ppb |
| SO₂ | 40 ppb |
| O₃ | 30 ppb |
| CO | 25 ppb |
| PM₂.₅ & PM₁₀ | <1.0 µg/m³ |
| Linearity | ±5% of full scale |
| Zero Drift | ±1% of full scale |
| Repeatability | ±2.5% of full scale |
| Resolution | 10 ppb (gases), 0.1 µg/m³ (PM) |
| Sample Flow Rate | >1.5 L/min |
| Data Logging Interval | 1 min to 1 h |
| Onboard Storage | >500,000 records (~1 year) |
| Operating Temperature | –10 °C to +45 °C |
| Operating Humidity | 15–90% RH (non-condensing) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Dimensions | 406 mm (H) × 305 mm (W) × 152 mm (D) |
| Weight | 5 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Harshaw TLD |
| Instrument Category | Radiation Dosimetry / Dose Rate Meter |
| Form Factor | Personal/Environmental Wearable |
| Measured Radiation Types | Photons, Beta Particles, Thermal Neutrons, Fast Neutrons |
| Detector Material | LiF:Mg,Cu,P |
| LiF | Mg,Ti |
| Dosimetric Quantities | Hp(10), Hp(3), Hp(0.07), H*(10), H′(0.07), Neutron Fluence-to-Dose Conversion |
| Window Thickness | 3.3 mg/cm² (beta), 42 mg/cm² (photon), 7 mg/cm² (TLD-100/H/700H), 100 mg/cm² (TLD-100 for high-energy photon attenuation) |
| Element Dimensions | 3 mm × 0.4 mm (neutron-sensitive chips) |
| Compliance | ANSI N545-1993, ANSI N13.32-1995, ANSI N13.37 (draft), DOELAP, NVLAP-accredited testing protocols |
| Software | Integrated dose calculation software with ANSI/ISO traceable algorithms |
| Packaging | Hermetically sealed, barcoded, contamination-resistant encapsulation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Hg CEMS |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRAN SapphIRe |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | 3880i |
| Instrument Type | Flue Gas PM CEMS |
| Measurement Principle | Dual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM) |
| Traceability | NIST-traceable mass concentration |
| Compliance | EPA PS-11, QA/QC Procedure 2, Method 5/17 Verified |
| Range | 0–250 mg/m³ (extendable to 0–5 mg/m³ low-range mode) |
| Accuracy | ±20% (uncorrected), ±10% (source-corrected) |
| Detection Limit | 0.25 mg/m³ (15-min integrated) |
| Response Time (T90) | 15 min |
| Power Supply | 200–240 VAC, 50/60 Hz, 30 A |
| Purge Air | 80 slpm at 0.55–0.7 MPa |
| Max Flue Gas Temp | 200 °C |
| Operating Ambient Temp (Controller) | 4–50 °C, non-condensing |
| Analog Outputs | 6 × 0–100 mV / 1/5/10 V, 6 × 0–20 mA / 4–20 mA |
| Digital I/O | 1 power-fail alarm, 10 relay outputs |
| Probe Dimensions | 1117.85 mm (W) × 474.73 mm (H) × 7.09 mm (D), with 914/1524 mm sheath |
| Probe Weight | 59 kg |
| Controller Dimensions | 482.6 mm (19″ W) × 189.5 mm (H) × 655.32 mm (D) |
| Controller Weight | 25 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410 |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | 5012, MAAP |
| Measurement Principle | Multi-angle absorption photometry |
| Measured Parameters | BC (Black Carbon), PM₁₀, PM₂.₅ |
| Detection Limit (2-min avg) | <100 ng/m³ BC, <0.66 M/m Babs |
| Detection Limit (10-min avg) | <50 ng/m³ BC, <0.33 M/m Babs |
| Detection Limit (30-min avg) | <20 ng/m³ BC, <0.13 M/m Babs |
| Flow Rate | 0.5–1.4 m³/h (16.7 L/min nominal) |
| Linearity Error | <1% @ 16.7 L/min |
| Filter Medium | Glass fiber tape (~40 m length) |
| Data Storage | 18,560 concentration values |
| Operating Temperature | −20 to +50 °C |
| Power | Instrument: 100–240 V, 50/60 Hz, 30 W |
| Pump | 220–240 V, 50/60 Hz, 100 W |
| Dimensions (Instrument) | 483 × 311 × 330 mm (W×H×D) |
| Weight (Instrument) | 22.5 kg |
| Pump Dimensions | 210 × 222 × 108 mm |
| Pump Weight | 6.1 kg |
| Analog Output | 0/4–20 mA or 0–10 V |
| Digital Interface | Dual RS-232 serial ports |
| Sampling Efficiency | >98% duty cycle |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Model 5014i Beta |
| Measurement Principle | Beta-ray attenuation |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Radioisotope Source | Carbon-14 (¹⁴C) |
| Range Options | 0–1.0 / 2.0 / 3.0 / 5.0 / 10.0 mg/m³ (equivalent to 0–100 / 1,000 / 2,000 / 3,000 / 5,000 / 10,000 µg/m³) |
| LOD | 6 µg/m³ (0.5-hr avg), 4 µg/m³ (1-hr avg), 3 µg/m³ (3-hr avg), 1 µg/m³ (24-hr avg) |
| Resolution | 1 µg/m³ |
| Accuracy | ±5% (mass measurement, NIST-traceable membrane standards) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Thermo Scientific 5030 SHARP (High-Volume Sampling Configuration) |
| Instrument Type | High-Volume Ambient Air Sampler |
| Sampling Path | Single-Channel |
| Flow Range | PM₁₀ & PM₂.₅: 40 SCFM (1,133 L/min) |
| Flow Accuracy | Mass Flow Control: ±2.5% deviation over 24 h |
| Volumetric Flow Control | <1% deviation over 24 h |
| Power | 750 W (Mass Flow) / 840 W (Volumetric Flow) |
| Motor | 0.6 HP (Mass Flow) / 0.1 HP (Volumetric Flow) |
| Compliance | EPA Reference Method for PM₁₀/PM₂.₅ (40 CFR Part 53), ISO 12103-1, ASTM D1424 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | 5030i |
| Measurement Principle | Beta-ray Absorption + Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Detection Limit | <0.5 µg/m³ (1-hr, 2σ), <0.2 µg/m³ (24-hr, 2σ) |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±5% (mass-based, traceable to NIST) |
| Range | 0–10,000 µg/m³ (7 full-scale options) |
| Flow Rate | 16.67 L/min (1 m³/h), ±2% accuracy |
| Operating Temperature | Sample gas: −30 to +50 °C |
| Analyzer enclosure | +4 to +50 °C |
| Power | 100–240 VAC, 50/60 Hz, max 880 W |
| Dimensions | 425 mm (W) × 584 mm (D) × 219 mm (H) |
| Weight | 19 kg |
| Compliance | US EPA Federal Equivalent Method (FEM) for PM₂.₅ and PM₁₀, CE, UL 61010-1, CSA C22.2 No. 61010-1, FCC Class B |