| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific MPC 20 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fluoride ISE (CS00F02) |
| Instrument Type | Fluoride Ion Selective Electrode |
| Measurement Range | 0.02 ppm to saturation |
| Compliance | ASTM D1129, ISO 10523, USP <771>, EPA Method 300.0 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Thermo Scientific Orion 2210AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Indophenol Blue) |
| Measurement Ranges | 0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N) |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L |
| Detection Limit | 0.01 mg/L (as N) |
| Analysis Time | ≤30 minutes per cycle |
| Temperature Control | Integrated thermostatically controlled cuvette with magnetic stirring |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific Orion 2210AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Indophenol Blue Reaction) |
| Measurement Ranges | 0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N) |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L |
| Detection Limit | 0.01 mg/L (as N) |
| Analysis Time | ≤30 minutes per cycle |
| Sample Throughput | Continuous online operation (no batch processing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310D-01 |
| Price | Upon Request |
| DO Range | 0.00–90.0 mg/L |
| DO Resolution | 0.1 / 0.01 mg/L |
| DO Saturation Range | 0.0–600% |
| Saturation Resolution | 1 / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation Range | 0–45 ppt |
| Atmospheric Pressure Range | 450–850 mmHg |
| Calibration Modes | Water-saturated air, air-saturated water, Winkler titration zero-point |
| Electrode Type | Polarographic membrane sensor |
| Temperature Range | −5 to 105°C |
| Temp Resolution | 0.1°C (−5 to 99.9°C), 1.0°C (>99.9°C) |
| Temp Accuracy | ±0.1°C |
| Temp Compensation | Automatic/manual |
| Display | Backlit LCD |
| Sensor Interfaces | DO-miniDIN, Temp-miniDIN, Stirrer-phone jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| GLP Features | Data logging (200 entries), calibration history (last 10), method storage (10), self-test diagnostics, password protection, network-enabled firmware/software updates |
| Power | 4×AA batteries + universal AC adapter (benchtop) |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| Enclosure Rating | IP54 (benchtop) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310D-24 |
| Pricing | Upon Request |
| Conductivity Range | 0.000–3000 mS/cm |
| Conductivity Resolution | Up to 0.001 µS/cm (4 significant digits) |
| Conductivity Accuracy | ±0.5% of reading or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19,999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 15°C, 20°C, or 25°C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Calibration Points | 1–5 point |
| Temperature Range | −5°C to 105°C |
| Temperature Resolution | 0.1°C (−5°C to 99.9°C), 1.0°C (>99.9°C) |
| Temperature Accuracy | ±0.1°C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD |
| Sensor Interfaces | Conductivity – miniDIN |
| Communication | Bidirectional RS232, optional USB cable |
| Data Storage | 200 GLP-compliant measurements |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Self-Diagnostic Function | Yes |
| Password Protection | Yes |
| Firmware/Method Update | Network-enabled |
| Power Supply | 4 × AA batteries or universal AC adapter (benchtop) |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| Ingress Protection | IP54 (benchtop) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Orion 3150 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Measuring Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Range | 0–2 / 0–10 / 0–50 mg/L (user-selectable ranges per parameter) |
| Accuracy | ±5% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 0.01 mg/L |
| Light Source (TN module) | Xenon flash lamp (rated for >10⁸ flashes) |
| Sample Handling | Integrated digestion-colorimetric cell with automated reagent dosing and thermal digestion |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Orion 3150 |
| Measurement Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Measurement Ranges | 0–2 mg/L, 0–10 mg/L, 0–50 mg/L (auto-ranging) |
| Accuracy | ±5% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 0.01 mg/L |
| [Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 320D-01 |
| Price | Upon Request |
| DO Range | 0.00–90.0 mg/L |
| DO Resolution | 0.1 / 0.01 mg/L |
| DO Saturation Range | 0.0–600% |
| DO Saturation Resolution | 1 / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| Calibration Modes | Water-saturated air, air-saturated water, Winkler titration zero-point |
| Electrode Type | Polarographic membrane electrode |
| Temperature Range | −5 to 105°C |
| Temp Resolution | 0.1°C (−5 to 99.9°C), 1.0°C (>99.9°C) |
| Temp Accuracy | ±0.1°C |
| Temp Compensation | Automatic/manual |
| Display | Backlit LCD |
| Sensor Interfaces | DO-miniDIN, Temp-miniDIN, Stirrer-phone jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| GLP Features | 200 data points, last 10 calibrations stored, 10 user methods, self-test diagnostics, password protection, network-enabled firmware/method updates |
| Power | 4×AA batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| IP Rating | Benchtop—IP54 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410D-01 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410P-01 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 420D-01 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 420P-01 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 510M-01 (Benchtop), 520M-01 (Portable) |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Orion 7070iX TRO |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | Orion 8010cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | (0.02–2) mg/L |
| Accuracy | ±3% of reading ±0.04 mg/L (0.02–2 mg/L) |
| Detection Limit | 0.02 mg/L |
| Analysis Time | ≤30 min |
| Resolution | 0.001 mg/L (<100 mg/L) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Sample Flow Rate | 50–1000 mL/min |
| Sample Pressure | 1–5 bar |
| Sample Temperature | 5–50 °C |
| Sample pH | 4–9 |
| Max. Turbidity (NTU) | <30 |
| Max. Color (Pt-Co) | <180 |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 450 × 737 × 322 mm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 100 W, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (max. 900 Ω load) |
| Digital Interface | RS485 |
| Relay Outputs | Two dry contacts (2 A @ 250 VAC) |
| Regulatory Compliance | cTUVus, CB, CE-LVD, RCM, FCC, CE-EMC, CE-RoHS, REACH, China RoHS |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Orion 8010cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | 0.02–2 mg/L |
| Accuracy | ±3% of reading + 0.04 mg/L (0.02–2 mg/L) |
| Detection Limit | 0.02 mg/L |
| Analysis Time | ≤30 min |
| Environmental Operating Temperature | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Sample Flow Rate | 50–1000 mL/min |
| Sample Pressure | 1–5 bar |
| Sample Temperature | 5–50 °C |
| Sample Requirements | TDS < 170 mg/L, TSS < 30 mg/L, pH 4–9, Color < 180 Pt-Co units |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 450 × 737 × 322 mm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 100 W, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (max. 900 Ω load) |
| Digital Interface | RS485 |
| Relay Outputs | Two dry contacts (2 A @ 250 VAC) |
| Regulatory Compliance | cTUVus, CB, CE-LVD, RCM (safety) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Orion 8030cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Heteropoly Molybdenum Blue Colorimetry |
| Detection Range | 0–5000 µg/L SiO₂ |
| LOD | <0.5 µg/L (typical, phosphate-compensated) |
| Enclosure Rating | IP65 |
| Reagent Replacement Interval | ≤100 days |
| User Interface | Capacitive Touchscreen Display |
| Platform Compatibility | Orion 8000 Series Multi-Parameter Platform |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model | AQ4EK1 |
| Pricing | Available Upon Request |
| Conductivity Range | 0–20.00 / 200.0 / 2000 µS/cm |
| Conductivity Resolution | 0.01 / 0.1 / 1 µS/cm |
| Conductivity Accuracy | ±1% of Full Scale |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| pH Electrode Slope | 80–120% |
| mV Range | –1000 to +1000 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±2 mV |
| Temperature Range (pH/Conductivity) | –10.0–110.0 °C (Conductivity), 0.0–100.0 °C (pH) |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.5 °C |
| Temperature Compensation | Automatic or Manual (0–50 °C for conductivity |
| Cell Constant Options | 0.1, 1.0, 10.0 cm⁻¹ |
| Reference Temperature Options | 20.0 °C or 25.0 °C |
| Conductivity Calibration Points | Up to 1 per range, max 5 total |
| pH Calibration Points | 1–3 points |
| Buffer Standards | USA (pH 4.01, 7.00, 10.01), NIST (pH 4.01, 6.88, 9.18), Pb (pH 4.10, 6.97) |
| Auto-Range Switching | Yes |
| Data Hold Function | Yes |
| Auto-Power-Off | 17 min (pH/mV), 20 min (conductivity) |
| Low-Battery Indicator | Yes (“LO” display) |
| Power Supply | 4 × AAA alkaline batteries |
| Battery Life | >500 h (pH/mV mode), >100 h (conductivity mode) |
| Dimensions | 14 × 7 × 3.5 cm |
| Weight | 200 g |
| Interface | BNC (conductivity sensor), needle-type thermistor port (temperature probe) |
| Display | Custom monochrome LCD |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | ISE Series |
| Instrument Category | Multi-Ion Analyzers |
| Compliance | ASTM D1129, ISO 10523, USP <798>, EPA Method 300.0, EN ISO 10304-1 |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A113, A123 |
| Pricing | Available Upon Request |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A323 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic & Optical (RDO) Fluorescence |
| DO Concentration Range | 0–90 mg/L (Polarographic), 0–50 mg/L (RDO) |
| DO Saturation Range | 0–600% (Polarographic), 0–500% (RDO) |
| Accuracy | ±0.001 pH / ±0.1 mV / ±0.2 mg/L (Polarographic, 0–20 mg/L) / ±0.1 mg/L (RDO, 0–8 mg/L) |
| Resolution | 0.001 pH / 0.1 mV / 0.01 mg/L (DO) |
| Temperature Range | 0–50 °C |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Compensation | 0–45 ppt |
| Data Storage | 5000 entries with timestamp, sample ID, user ID, calibration data |
| Compliance | GLP-compliant data logging, FDA 21 CFR Part 11-ready software support |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A329 |
| Instrument Type | Portable Multiparameter Water Quality Analyzer |
| Compliance | GLP-Compliant Data Logging (5000 Entries) |
| Protection Rating | IP67 |
| Power | 4×AA Batteries or AC Adapter |
| Connectivity | USB & RS232 |
| Software Support | Orion™ Comli Software (FDA 21 CFR Part 11 Ready) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Orion Star LogR Series |
| Model | LogR pH/ISE |
| Measurement Principle | Potentiometric (Glass Electrode + ISE) with LogR™ Membrane Resistance-Based Temperature Sensing |
| Compliance | ASTM D1293, ISO 10523, USP <791>, EPA Method 150.1, GLP-Ready |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Star RDO |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Reference/Equivalent Method PM Sampler |
| Models | Partisol 2000i (single-channel), Partisol 2000i-D (dual-channel) |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min (2000i-D), Coarse Particle Flow Rate: 1.67 L/min (2000i-D) |
| Total Flow Range | 5–17 L/min (2000i) |
| Data Storage | 86 days @ 5-min intervals, 32 filter records |
| Operating Temperature | −40 °C to +50 °C |
| Power | 1.1 A @ 240 VAC |
| Dimensions (H×W×D) | 1620 mm × 1175 mm × 927.5 mm (base unit) |
| Weight | 37.2 kg (2000i), 38.6 kg (2000i-D) |
| Compliance | U.S. EPA RFPS-0498-117 (PM₂.₅), RFPS-1298-126 (PM₁₀), RFPS-0509-175 (Coarse PM) |
| Filter Format | Dual 47 mm filter holders (2000i-D), single 47 mm holder (2000i) |
| Cut Points | PM₂.₅ (cyclone or impactor), PM₁₀ (inlet), Coarse PM (PM₁₀–PM₂.₅ via virtual impactor in 2000i-D) |
| Interface | RS-232, USB, Ethernet |
| Software | iPort™ Communications Suite, Activol™ Flow Management System |
| Safety Certification | CE EN 61326 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2000i-D / 2000i |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min |
| Coarse Particle Flow Rate | 1.67 L/min |
| Filter Format | Dual 47 mm membrane holders |
| Data Logging Interval | 5 min |
| Internal Memory Capacity | 86 days @ 5-min intervals + 32 filter records |
| Communication Interfaces | RS-232, USB, Enhanced Ethernet (iPort™) |
| Operating Temperature Range | −40 °C to +50 °C |
| Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), Equivalent Method for PM₁₀ and Coarse PM (PM₁₀–PM₂.₅), ASTM D6216, ISO 7708 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 2015i/2025i-D |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15.0 L/min ±2% |
| Coarse Particle Flow Rate | 1.67 L/min ±2% |
| Filter Format | Dual 47 mm membrane filters per sampling cycle |
| Filter Capacity | Up to 16 filter cassettes (32 total filters) |
| Data Logging Interval | 5-minute resolution |
| Internal Memory | 86 days of operational data (5-min intervals) + 32 filter cycle records |
| Communication Interfaces | RS-232, USB 2.0, Ethernet (10/100 Mbps), iPort™ embedded communications module |
| Operating Temperature Range | −40 °C to +50 °C |
| Regulatory Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), EPA Equivalent Method for PM₂.₅ and Coarse PM (PM₁₀–PM₂.₅), ISO 12103-1, ASTM D1739, EN 12341 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Models | Partisol 2025i, Partisol 2025i-D |
| Flow Control | Activol Mass Flow Controller |
| Volume Flow Range | 1.67–15 L/min |
| Flow Accuracy | ±2% of setpoint |
| Operating Temperature | −40 °C to +50 °C |
| Power Requirement | 1.5 A @ 240 VAC |
| Data Storage | 86 days at 5-minute intervals + 32 filter records |
| Compliance | U.S. EPA Reference Methods RFPS-0498-118 (PM₂.₅), RFPS-1298-127 (PM₁₀), RFPS-0509-176 (Coarse PM) |
| Safety Certification | CE / EN 61326 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PDM3600 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0–200 mg/m³ |
| Resolution | 0.05 mg/m³ (1σ, 30-sec average) |
| Accuracy | ±25% of reference method (for concentrations >0.2 mg/m³) |
| Relative Humidity Range | 0–100% RH |
| Operating Temperature | −20°C to +40°C |
| Mass Sensor Temperature Range | 0°C to +60°C |
| Sampling Flow Rate | 2.2 L/min (±2% σ in lab |
| Minimum Detectable Load | 0.1 mg |
| Maximum Load Capacity | 4 mg |
| Dimensions (Monitor Housing) | 24.31 cm W × 8.26 cm D (excl. clip) / 8.69 cm D (incl. clip) × 17.15 cm H (excl. PTO) / 19.30 cm H (incl. PTO) |
| Weight (Monitor) | 2.27 kg |
| Umbilical Cable | 167 cm long, 0.51 kg |
| TEOM Sensor Module | 5.82 cm W × 4.9 cm D × 7.75 cm H |
| Charging Module | 7.21 cm W × 15.25 cm D × 19.38 cm H, 1.42 kg |
| Power Supply | Dual internal lithium-ion battery packs |
| Compliance | MSHA Approval No. 19-A040002-0 |
| EN 61326-1 | 2005 |
| Charger | ANSI/UL 1012, Class 2, 7th Ed. (Apr 29, 2005) |