| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 55i |
| Detection Principle | Gas Chromatography (GC) with Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Emission Monitor |
| Configuration | Dual-Channel GC-FID for Simultaneous CH₄ and NMHC Quantification |
| Measurement Ranges | 0–5/50/500 ppm |
| Resolution | 0.050 ppm CH₄ |
| Accuracy | ±2% of reading or ±50 ppb (whichever is greater) |
| Response Time (t₉₀) | 70 s |
| Zero Noise | 0.025 ppm RMS (300-s averaging) |
| MDL | 0.050 ppm CH₄ |
| Span Drift (24 h) | <2% of full scale |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Analyzer |
| Configuration | Multi-component VOC Analyzer |
| Detection Range | 0–50 ppm / 500 ppm / 5,000 ppm / 50,000 ppm / 500,000 ppm (as methane) |
| Resolution | 50 ppb |
| Accuracy | ±1% of full scale or 0.1 ppm (whichever is greater) |
| Response Time | <1 minute for NMHC analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Model | Thermo Scientific 5800 |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-component VOC Analyzer |
| Detection Range | 0–50 ppm / 500 ppm / 5,000 ppm / 50,000 ppm / 500,000 ppm (as methane) |
| Resolution | 50 ppb |
| Accuracy | ±1% of full scale or ±0.1 ppm (whichever is greater) |
| Response Time | <1 minute for NMHC analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | 5800-GO |
| Price Range | USD $42,000–$70,000 (FOB) |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Portable |
| Configuration | Multi-component VOC Analyzer |
| Measurement Ranges | 0–50, 500, 5,000, 50,000 ppm |
| Resolution (as propane) | 30 ppb |
| Response Time | ≤2 min (methane/non-methane hydrocarbons) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Thermo Scientific 5900 VOCs |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Continuous Analyzer |
| Detection Range | NMHC 0–5 ppm |
| Accuracy | ≤ ±10% |
| Response Time | ≤ 15 min |
| Compliance | Designed for EN 13526, EPA Method 25A, ISO 11890-2, and US EPA Compendium Method TO-17 (with preconcentration) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Thermo Scientific 5900 VOCs |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Continuous Analyzer |
| Detection Range | NMHC 0–5 ppm |
| Accuracy | ≤ ±10% |
| Response Time | ≤ 15 min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 5900-A |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Detection Limit | ≤30 ppb (as methane) |
| Compliance | ASTM D6348, EPA Method 25A, HJ 1012-2018, HJ 38-2017 |
| Installation Form | 19-inch rack-mountable chassis |
| Control System | Integrated EPC (Electronic Pressure Control) for carrier gas and sample flow |
| Data Output | Modbus TCP, RS-232/485, Analog 4–20 mA |
| Software | Thermo Scientific Chromeleon™ CDS (with 21 CFR Part 11 compliance option) |
| Operating Environment | 5–40 °C, <90% RH non-condensing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | 5900-A |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | 6000 VOC |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Gas Analyzer |
| Typical Configuration | Multi-Component VOC CEMS |
| Measurement Range | 0–5000 ppm (as methane or NMHC) |
| Accuracy | ±1% Full Scale or ±0.1 ppm |
| Response Time | ≤60 s (for NMHC, T90) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 6000 VOC |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-Component VOC CEMS |
| Measurement Range | 0–5000 ppm (as methane or NMHC) |
| Accuracy | ±1% F.S. or ±0.1 ppm |
| Response Time | ≤60 s (for NMHC) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | 6000 VOC |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-component VOC CEMS |
| Measurement Range | 0–5000 ppm (as methane or NMHC) |
| Accuracy | ±1% F.S. or ±0.1 ppm |
| Response Time | ≤60 s (for NMHC) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 6800 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 6800 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ADR-1500 |
| Pricing | Upon Request |
| Measurement Principle | Optical Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Enclosure Rating | IP65 |
| Power Options | AC, External DC, Internal Rechargeable Battery |
| Communication Interfaces | USB, RS-232, 0–5 V / 4–20 mA Analog Output, Optional Wireless Module |
| Environmental Compensation | Integrated Temperature, Relative Humidity, and Barometric Pressure Sensors with Active Heating |
| Flow Control | True Volumetric Flow Control via Digital Feedback Loop Using Calibrated Critical Orifice and Differential Pressure Sensor |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific ADR-1500 |
| Measurement Principle | Optical Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀, PM₂.₅, PM₄, PM₁ |
| Measurement Range | 0.001–400 mg/m³ (Auto-ranging) |
| Detection Limit | 0.1 µg/m³ |
| Sampling Flow Rate | 1.0–3.5 L/min |
| Flow Stability | ±2% of reading or ±0.005 mg/m³ (whichever is greater), 1-s averaging |
| Accuracy | ±5% of reading (traceable to SAE test standards) |
| Precision | ±2% (1 s), ±0.5% (10 s), ±0.2% (60 s) |
| Scatter Coefficient Range | 1.1×10⁻⁶ to 0.6 m⁻¹ (@ λ = 880 nm) |
| Aerodynamic Particle Size Cut Points | 1.0–10 µm (with optional cyclone cutters: GK2.05 for PM₄–PM₁₀ |
| Operating Environment | IP65-rated weatherproof enclosure |
| Power Options | AC, external DC, or internal rechargeable battery (up to 100 h continuous operation) |
| Data Connectivity | Wireless/3G, USB, RS-232, analog output |
| Onboard Display | Dual-line LCD showing real-time concentration, start time, date, average concentration, and runtime |
| Temperature & Humidity Compensation | Integrated heated sensor assembly with RH/T correction |
| True Volumetric Flow Control | Enabled via digital feedback from barometric pressure, temperature, and calibrated orifice ΔP sensors |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AerosolSense & Renvo |
| Instrument Type | Aerosol Pathogen Monitoring System |
| Detection Target | Influenza A/B, SARS-CoV-2, RSV-B |
| Sample Processing Time (Renvo) | ≤30 min |
| Amplification Technology | Oscillating Amplification Reaction (Oscar™) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific Alpha |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Thermo Scientific AM16 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Thermo Scientific AnalogPlus |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | APDPHYL500 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific APDSOIL |
| Instrument Category | Online Analyzer |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Measurement Ranges | 0.1–10 ppm, 0.2–100 ppm, 1–1000 ppm |
| Detection Limits | 0.1 ppm, 0.2 ppm, 1 ppm |
| Accuracy | ≤3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | APIX |
| Detection Targets | Conventional + Specialty Gas Trace Impurities |
| Detection Method | Atmospheric Pressure Ionization Mass Spectrometry (API-MS) |
| Mass Range | 1–300 AMU |
| Ion Source | Atmospheric Pressure Ionization (API) |
| Background Level | <1 ppt |
| Detector | 100 MHz Pulse-Counting Electron Multiplier |
| Noise Floor | 10 counts per 10⁶ pulses |
| LOD | <10 ppt (compound-dependent) |
| Analysis Time per Component | <1 s |
| Typical Cycle Time | <5 s |
| Flow Path Switching Time | <15 min (to sub-ppb stability) |
| Compatible Bulk Gases | UHP H₂, N₂, Ar, He |
| Dimensions (δQ) | 1.9 m (H) × 0.7 m (W) × 0.65 m (D) |
| Dimensions (Quattro) | 1.9 m (H) × 2.1 m (W) × 0.65 m (D) |
| Communication Protocols | OPC UA, Modbus TCP/RTU, PROFIBUS DP, Siemens 3964R, DDE, EtherNet/IP |
| Software Platform | Thermo Scientific GasWorks® v5.x |
| Compliance | Designed for ISO 9001-certified manufacturing |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APIX |
| Detection Range | 1–300 AMU |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific AQ4700 |
| Instrument Type | Online |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Time | 5 min |
| Compliance | ISO 11348 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AQ4700 |
| Instrument Category | Online |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Time | 5 min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific AquaClear |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Parameter | Turbidity |
| Compliance | Meets and exceeds USEPA Method 180.1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | 3110TP |
| Application | Online Water Quality Monitoring |
| Measured Parameter | Total Phosphorus (TP) |
| Measurement Range | 0–1 / 0–2 / 0–10 / 0–50 mg/L |
| Accuracy | <5% for standard solutions |
| Detection Limit | 0.01 mg/L |
| Resolution | < ±5% of Full Scale |
| Instrument Type | Online Automated Analyzer |
| Compliance Context | Designed for continuous operation in compliance with ISO 15681-1 (Water quality — Determination of phosphorus — Part 1: Spectrophotometric determination after digestion) and supports GLP/GMP data integrity requirements via audit-trail-capable software |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 3110TP |
| Measurement Parameter | Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Acid Digestion + Molybdenum Blue Colorimetry |
| Measurement Ranges | 0–1 / 0–2 / 0–10 / 0–50 mg/L as P |
| Accuracy | <5% for standard solutions |
| Detection Limit | 0.01 mg/L |
| Resolution | < ±5% of Full Scale (F.S.) |
| Repeatability | <5% of reading |
| Data Storage Capacity | 20,000 records with auto-rollover |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Enclosure Rating | IP66 / NEMA 4X |
| Dimensions (W×H×D) | 510 × 775 × 330 mm |
| Weight | 40 kg (instrument only) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | AquaEZ 3130 COD |
| Instrument Type | Online Analyzer |
| Wavelength | 450 nm |
| Measurement Range | 10–4000 mg/L |
| Accuracy | ±10% of reading (for samples >100 mg/L) |
| Repeatability | <5% of reading |
| Limit of Detection | 15 mg/L |
| Analysis Time | 45 minutes per cycle |
| Batch Capacity | 30 samples per 30-minute interval |
| Zero Drift | ≤5 mg/L |
| Protection Rating | IP65 / NEMA 4 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×H×D) | 510 × 775 × 330 mm |
| Weight | 40 kg (excluding reagents) |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Output Interfaces | Dual 4–20 mA analog outputs, RS232 standard, RS485 optional |
| Digital I/O | 2 digital inputs, 8 digital outputs |
| Calibration Modes | Automatic scheduled, manual, and external-triggered |
| Data Storage | Up to 2 years of time-stamped measurement history with event tagging (M = maintenance, D = fault, C = calibration) |
| Display | Color LCD screen showing real-time results, calibration curves, and historical trends |
| Digestion Conditions | 165 °C, duration adjustable from 10–30 minutes |
| Measurement Modes | Continuous, periodic, timed, or external signal-triggered |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific AquaOZ |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Application | Real-time Dissolved Ozone Monitoring in Process Water Streams |
| Electrode Technology | Clark-type Amperometric Three-Electrode Sensor System |
| Controller Platform | AquaPro Multi-Channel Process Controller (up to 4 channels) |
| Data Logging Capacity | 1,000 data points with USB export |
| Firmware Update | USB-port field-upgradable |
| Language Support | 6 languages including English, Chinese, Spanish, French, German, and Portuguese |
| Membrane Assembly | Pre-filled, disposable membrane cap with electrolyte |
| Temperature Compensation | High-accuracy integrated Pt1000 RTD sensor |
| Housing Material Options | PVC, PVDF, 316L SS, and Hastelloy C-276 |