Environmental Test Chamber
Filter
Showing 2731–2760 of 3663 results
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH600-HSC |
| Salt Spray Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 640 L |
| Humidity Control | Yes (RH 10–95% RH, ramp rate programmable) |
| Optional Features | Spray Module, Nozzle Auto-Cleaning System, Preconditioned Air Humidification |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2027, GB/T 10125, ISO 16701, Prohesion™ |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH600-HSC |
| Chamber Capacity | 640 L |
| Humidity Control Range | 10–95% RH (±2% RH typical accuracy) |
| Temperature Range | Ambient +10°C to 70°C |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117) |
| Heating Method | Forced-air convection (no steam generation) |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, ISO 16701, Prohesion™ protocol |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Q-FOG SSP-600 / SSP-1100 / CCT-600 / CCT-1100 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Air-Pressure-Assisted Exhaust |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 10–80 °C |
| Chamber Capacities | 640 L (SSP-600/CCT-600), 1103 L (SSP-1100/CCT-1100) |
| Sample Capacity | 160 specimens (75 mm × 150 mm) for 600-series |
| Humidity Control | Up to 100% RH (CCT models only) |
| Integrated Solution Reservoir | 120 L with built-in saltwater filter and low-level alarm |
| Heating/Cooling System | Internal resistive heaters + high-capacity forced-air cooling/drying fan |
| Controller | Microprocessor-based with self-diagnostic functions, cycle programming, service reminders, and safety shutdown |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor (not OEM) |
| Product Origin | Imported |
| Model | Q-FOG Series (e.g., Q-FOG CRH, Q-FOG SST, Q-FOG CCT) |
| Pricing | Available Upon Request |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Compression Exhaust |
| Salt Fog Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG Gas Corrosion Test Chamber |
| Temperature Range (°C) | Consult Technical Specifications |
| Corrosive Gas Compatibility | SO₂, H₂S, Cl₂, NO₂, CO₂, NH₃ (configurable per test standard) |
| Chamber Volume | Standard 60 L / 110 L / 1400 L options |
| Control System | Integrated microprocessor-based controller with real-time monitoring and programmable cycle sequencing |
| Compliance | ASTM B809, IEC 60068-2-60, ISO 21207, DIN EN ISO 16701, JIS Z 2371 (gas corrosion variants), UL/CSA certified electrical safety |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP 1100 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Air Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Compressed-air-assisted雾 expulsion |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 20–60 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Q-FOG SSP and CCT |
| Spray Method | Multiple (including continuous salt spray, Prohesion™, and cyclic humidity/dry phases) |
| Nozzle Pressure | 0.7–1.4 bar |
| Salt Solution Deposition Rate | 1.0–2.0 mL per 80 cm² per hour |
| Temperature Range | 35–70 °C |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Air Pressure | 0.7–1 kg/cm² |
| De-misting Method | Pneumatic Air-Driven Fog Exhaust |
| Salt Solution Reservoir Capacity | 120 L |
| Operating Temperature Range | Ambient to 50°C (controlled per cycle phase) |
| Cycle Phases | Salt Fog, Dry-off, Rest (Static), Optional Humidity (CCT only) |
| Compliance | ASTM B117, ASTM G85 (Annex A1–A5), ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP |
| Compliance | ASTM B117, ASTM G85, ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Cycle Capabilities | Salt Spray, Prohesion®, Dry-off, Optional Humidity (CCT only) |
| Control System | Microprocessor-based dual-line LCD interface with programmable multi-step cycling |
| Construction | Fiberglass-reinforced polymer (FRP) chamber body, corrosion-resistant stainless steel hardware |
| Temperature Range | Ambient to 50 °C (spray/dry modes), up to 60 °C (optional humidified mode in CCT models) |
| Solution Delivery | Pneumatic air-assisted atomization via adjustable nozzles, bubble-tower humidified air (except Prohesion®) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | SSP |
| Salt Fog Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70°C |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP |
| Compliance | ASTM B117, ASTM G85 (Prohesion), ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Chamber Volume | 640 L (SSP-600) or 1103 L (SSP-1100) |
| Temperature Range | Ambient to 50 °C (operational during salt fog cycle) |
| Salt Solution Delivery | Precision metered pneumatic spray system with adjustable nozzle pressure and calibrated collection rate (1.0–2.0 mL/80 cm²/h per ASTM B117) |
| Control System | Touchscreen programmable controller with multi-step cycling capability, real-time logging, and audit-trail-ready event history |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | SSP Series |
| Compliance | ASTM B117, ASTM G85 (Prohesion™), ISO 9227, BS 3900-F4/F9, DIN 50021 |
| Temperature Range | Ambient to 50 °C (operational range for salt fog and dry-off cycles) |
| Salt Solution Delivery | Precision metered spray via pneumatic atomization |
| Chamber Capacity | Available in multiple standard sizes (e.g., SSP-600, SSP-1200) |
| Control System | Touchscreen PLC-based controller with cycle programming and real-time logging |
| Humidity Control | Not applicable (non-humidity-controlled |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP-600, Q-FOG SSP-1100, Q-FOG CCT-600, Q-FOG CCT-1100 |
| Temperature Range | 20–70 °C (spray/dry), 20–60 °C (RH/humidity) |
| Chamber Capacity | 640 L (SSP/CCT-600), 1103 L (SSP/CCT-1100) |
| Salt Solution Reservoir | 120 L |
| Sample Capacity | 160 panels (75 × 150 mm) for 600-series |
| Spray Rate | 1–2 mL/80 cm²·hr |
| Air Pressure | 0.7–1.0 kg/cm² (≈70–100 kPa) |
| Humidity Control | 95–100% RH (CCT models only) |
| Power Supply | 208–230 V, 50/60 Hz, 13–38 A |
| Weight (dry) | 224–378 kg |
| Water Purity Requirement | <8 ppm TDS, >50 kΩ·cm resistivity |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP-600 |
| Compliance | ASTM B117, ASTM G85 (Annex A2–A5), ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Chamber Capacity | 160 × 75 mm × 150 mm test panels |
| Internal Solution Reservoir | 120 L |
| Operating Modes | Salt Spray, Dry-off, Humidity Hold (CCT models only), Rest |
| Control System | Microprocessor-based programmable controller with self-diagnostic functions |
| Required Supply | Deionized or purified water (≥1 MΩ·cm resistivity) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP-600 |
| Salt Spray Deposition Rate | 0.5–3.0 mL/(h·80 cm²) |
| Temperature Range | Ambient to 70°C |
| Compliance | ASTM B117, ASTM G85 (Prohesion), ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP1100 |
| Salt Spray Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 1103 L |
| Compliance Standards | ASTM B117, ASTM G85 (Prohesion), ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP1100 |
| Chamber Capacity | 1103 L |
| Salt Fog Deposition Rate | Adjustable per ASTM B117 & ISO 9227 |
| Temperature Range | 15–50 °C (operational range during salt fog, dry, and humidity cycles) |
| Sample Capacity | Up to 240 standard test panels |
| Internal Solution Reservoir | 120 L |
| Compliance | ASTM B117, ASTM G85 (Annex A2–A5), ISO 9227, BS EN 3900 F4/F9, DIN 50021, SAE J2334, GMW 14872, Ford CETP 00.00-L-467 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | SSP600 |
| Chamber Capacity | 640 L |
| Sample Capacity | 160 × 75 mm × 150 mm test panels |
| Salt Solution Delivery | Variable-speed peristaltic pump |
| Temperature Range | Ambient to 50 °C (operational range per ASTM B117 & ISO 9227) |
| Corrosion-Resistant Construction | Fiberglass-reinforced polymer (FRP) interior, no internal steel structure |
| Compliance | ASTM B117, ASTM G85 (Annex A5 Prohesion), ISO 9227, DIN 50021, BS 3900 F4/F9, GB/T 10125 |
| Humidity Control | Not supported (SSP series lacks 100% RH conditioning) |
| Internal Reservoir | 120 L deionized water-compatible tank with level sensor and inline salt solution filter |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP600 |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Compression Exhaust |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 20–60 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP600 |
| Chamber Capacity | 640 L |
| Test Modes | ASTM B117 (Continuous Salt Fog), Prohesion™, and Custom Cyclic Corrosion Testing |
| Salt Solution Delivery | Precision-controlled via variable-speed peristaltic pump and regulated compressed air |
| Temperature Range | 25–50 °C (operational range during salt fog cycle) |
| Salt Deposit Rate | Adjustable and compliant with ASTM B117 (1.0–2.0 mL/80 cm²/h) |
| Internal Reservoir | 120 L with integrated salt solution filter and low-level alarm |
| Sample Capacity | 160 test panels (75 mm × 150 mm) |
| Compliance | ASTM B117, ASTM G85 (Annex A1–A5), ISO 9227, DIN 50021, BS EN ISO 9227, BS 3900-F4/F9 |
| Controller | Embedded microprocessor with full self-diagnostic suite, real-time status display, service alerts, and safety shutdown |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Q-Panel |
| Pricing | Available Upon Request |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Q-LAB B02 |
| Xenon Lamp Power | 1800 W (air-cooled) |
| Irradiance Range | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Control | Integrated RH system (range per ISO 105-B02 and AATCC TM16 specifications) |
| Sample Capacity | 31 AATCC specimens (46 × 264 mm each), total exposure area: 1882 cm² |
| Lamp Life | ~1500 hours |
| Calibration Compliance | NIST-traceable, ISO/IEC 17025 accredited (A2LA Cert. #2382-01, #2383-02, #2383-03) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-SUN B02 |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Control | Standard |
| Water Spray Option | Available |
| Lamp Type | Air-Cooled 1800 W Xenon Arc Lamp |
| Lamp Life | ~1500 h |
| Sample Capacity | 31 AATCC pre-cut specimens (1882 cm² total exposure area) |
| Compliance | ISO 105-B02, ISO 105-B04, AATCC TM16 (Options 2 & 3), AATCC TM169, M&S C9/C9A |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-LAB Q-SUN B02 |
| Xenon Lamp Power | 1800 W |
| Irradiance | 42 W/m² (broadband, 300–800 nm) |
| Light Exposure Duration | 1500 h (lamp life at nominal output) |
| Humidity Range | 35–65 % RH |
| Operating Temperature Range | 35–65 °C (chamber air) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN B02 |
| Xenon Lamp Power | 1800 W (air-cooled) |
| Lamp Life | ~1500 hours |
| Filter Configuration | Dual-filter system with outer borosilicate tube and inner 7-piece filter sets (Window-B/SL per AATCC TM16 |
| Compliance | Designed to meet ISO 105-B02, AATCC TM16, and related textile colorfastness standards |
| Cooling Method | Air-cooled lamp assembly |
| Lamp Replacement | Top-access, single connector + two set screws |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN B02-S |
| Xenon Lamp Power | 1800 W |
| Compliance | ISO 105-B02, ISO 105-B04, AATCC TM 16 (Option 2 & 3), AATCC TM 169, M&S C9/C9A |
| Sample Capacity | 31 AATCC pre-cut specimens (1882 cm² total exposure area) |
| Lamp Type | Air-cooled xenon arc lamp |
| Lamp Life | ~1500 hours |
| Temperature Control | Blackboard temperature (35–103 °C), chamber air temperature |
| Humidity Control | Relative humidity (RH) with optional water spray |
| Filter System | Dual-filter assembly (outer borosilicate tube + inner 7-element filter set) for Window-IR (ISO/M&S) or Window-B/SL (AATCC) spectral profiles |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model Series | Q-SUN Xe-1, Xe-2, Xe-3 |
| Xenon Lamp Power | 1800 W |
| Irradiance (at 340 nm) | up to 1.30 W/m²/nm |
| Typical Broadband Irradiance | 42 W/m² (with Window-SF5/IR/B04 filters) |
| Lamp Life | up to 3000 h (X-1800+/X-1850+ lamps) |
| Black Panel Temperature Range | 25–120 °C (model-dependent) |
| Relative Humidity Control | 20–95% RH (Xe-2 & Xe-3 only) |
| Water Purity Requirement | >5 MΩ·cm, <0.2 µS/cm, <0.1 ppm TDS (for spray/humidification) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 / Xe-2 / Xe-3 |
| Xenon Lamp Power | 1800 W per lamp |
| Lamp Cooling | Air-cooled |
| Filter Options | Daylight, Window Glass, Extended UV |
| Sample Capacity | Xe-1: 251 mm × 457 mm (flat) |
| Xe-2 | 31 × 46 mm × 122 mm specimens on rotating drum |
| Xe-3 | 451 mm × 718 mm (flat) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02, GB/T 16422.2 |
| Humidity Control | Yes (Xe-2 & Xe-3 standard |
| Water Spray | Yes (deionized water, programmable during light/dark cycles) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1, Q-SUN Xe-3, Q-SUN B02 |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Control | Yes (RH range per IEC 60068-2-78 & ASTM G154) |
| Water Spray | Purified water spray, programmable during light/dark cycles |
| Lamp Type | Air-cooled xenon arc lamp |
| Lamp Life | ~1500 hours |
| Filter Options | Daylight, Window Glass, Extended UV (per ISO 4892-2, ASTM G155, SAE J2527) |