| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Compliance | ASTM B117, ASTM G85 Annex A5 (Prohesion), ISO 9227, SAE J2334, GMW 14872, Ford CETP 00.00-L-467, Renault D17 2028 |
| Chamber Capacity | 640 L (CCT-600) / 1103 L (CCT-1100) |
| Temperature Range | 10–70 °C (operational range under cyclic conditions) |
| Salt Solution Delivery | Precision-controlled via variable-speed peristaltic pump and regulated compressed air |
| Humidity Control | 100% RH capability (CCT only) |
| Sample Capacity | 160 specimens (75 mm × 150 mm) for CCT-600 |
| Internal Reservoir | 120 L deionized water tank with integrated salt solution filter and low-level alarm |
| Cycle Flexibility | Four-phase cycling — Salt Fog, Dry-off, 100% RH (CCT only), and Ambient Rest |
| Controller | Embedded microprocessor with self-diagnostic firmware, audit-trail-capable logging (FDA 21 CFR Part 11 compliant configuration available), and intuitive touchscreen interface |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CCT |
| Compliance | ASTM B117, ISO 9227, ISO 11997, ASTM G85 (Annex A1–A5), SAE J2334, GMW 14872, VDA 621-415, JIS Z 2371, DIN 50021, BS EN ISO 7253 |
| Humidity Range | 100% RH (CCT-specific) |
| Temperature Control | Spray, Dry, and Humidify Modes with Independent Heating Systems |
| Chamber Capacity | Standard configurations available (e.g., CCT-1100, CCT-2100) |
| Control System | Touchscreen Programmable Controller with Multi-Step Cycling Capability |
| Construction | Fiberglass-Reinforced Polymer (FRP) Cabinet, Corrosion-Resistant Interior |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CCT Series |
| Type | Cyclic Corrosion Test Chamber |
| Compliance | ASTM B117, ISO 9227, ASTM G85 (Annexes A1–A5), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VW PV1210 |
| Temperature Range | 10–70 °C (operational range per test method) |
| Humidity Control | 100% RH (CCT only) |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117) |
| Chamber Volume | Available in multiple standard sizes (e.g., CCT-1100: 1100 L) |
| Controller | Q-FOG Touchscreen Microprocessor with Multi-Step Program Logic, Audit Trail Logging, and User Access Levels |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT SSP CRH |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH/humidity) |
| Chamber Capacity | 640 L (CCT-600/SSP-600/CRH-600) or 1103 L (CCT-1100/SSP-1100/CRH-1100) |
| Internal Salt Solution Reservoir | 120 L |
| Sample Rack Capacity | 160 pcs (75 mm × 150 mm) for 600-series |
| Relative Humidity Control | 95–100% RH (CCT), fully adjustable 10–95% RH (CRH) |
| Air Pressure Requirement | 3–10 bar |
| Water Purity | <8 ppm TDS, resistivity >50 kΩ·cm |
| Power Supply | 208–230 V, 50/60 Hz, up to 38 A |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT-1100 |
| Salt Spray Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 1103 L |
| Sample Capacity | 160 panels (75 mm × 150 mm) |
| Humidity Control | Up to 100% RH |
| Cycle Modes | Salt Spray, Dry, High Humidity (100% RH), and Hold/Rest |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT-600 |
| Chamber Types | Salt Spray, Dry-off, 100% RH Humidity (CCT only), and Ambient Hold |
| Control System | Microprocessor-based Programmable Controller with Self-Diagnostic Functions |
| Internal Solution Reservoir | 120 L with Integrated Saltwater Filter and Low-Level Alarm |
| 雾 Dispersion | Variable-Speed Peristaltic Pump + Adjustable Air Pressure Regulator for Independent Control of Salt Spray Deposition Rate and Pattern |
| Temperature Transition Speed | Rapid due to In-Chamber Heaters and High-Capacity Cooling/Drying Blower |
| Water Requirement | Deionized or Distilled Water Only |
| Compliance Support | Designed to meet ASTM B117, ASTM G85 Annexes (A1–A5), ISO 9227, ISO 11997, VDA 621-415, GMW 14872, Ford CETP 00.00-L-467, SAE J2334, and other cyclic corrosion test standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT-600 |
| Salt Spray Deposition Rate | 0.5–3.0 mL/(h·80 cm²) |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 640 L |
| Sample Capacity | 160 panels (75 mm × 150 mm) |
| Humidity Control | Up to 100 % RH |
| Compliance | ASTM B117, ASTM G85 (Annex A1–A5), ISO 9227, DIN 50021, VDA 621-415, GMW 14872, Ford CETP 00.00-L-467, SAE J2334 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT1100 |
| Chamber Volume | 1100 L |
| Cycle Types | Salt Spray / High-Humidity (100% RH) / Dry |
| Compliance | ASTM B117, ISO 9227, ASTM G85 Annex A5 (Prohesion), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, Renault D17 2028 |
| Control System | Touchscreen-based Q-FOG Controller with Audit Trail & User Access Levels |
| Data Logging | Internal memory + USB export |
| Construction | Fiberglass-reinforced polymer (FRP) chamber body, corrosion-resistant stainless steel hardware |
| Humidity Range | 100% RH (CCT only) |
| Temperature Range | Ambient to 50°C (typical operational range for cyclic corrosion testing) |
| Salt Fog Deposition Rate | Adjustable per ASTM B117 (typically 1.0–2.0 mL/80 cm²/h) |
| Air Supply | Oil-free compressed air (4–6 bar) |
| Power Requirement | 208–240 VAC, 50/60 Hz, 30 A |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT1100 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Pressure-Assisted Exhaust |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 10–80 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT1100 |
| Chamber Capacity | 1103 L |
| Cycle Capabilities | Salt Spray, Dry, 100% RH Humidity, and Hold |
| Control System | Integrated Microprocessor-Based Q-FOG Controller with Self-Diagnostic Functions |
| Solution Delivery | Precision-Controlled Peristaltic Pump + Adjustable Air Pressure Regulator |
| Water Requirement | Deionized or Distilled Water (Resistivity >50 kΩ·cm, Particles <200 µm) |
| Power Supply | 220–240 V, 50–60 Hz, Single Phase, Max 4.2 kW |
| Exhaust Duct | 4" (102 mm) ID Required |
| Operating Ambient Temperature | 19–27 °C |
| Internal Reservoir | 120 L with Saltwater Filter & Low-Level Alarm |
| Sample Capacity | 240 test panels (75 mm × 150 mm) or custom 3D fixtures via 20 mm diameter hanging rods |
| Compliance | Designed to support ASTM B117, ISO 9227, ASTM G85 Annex A5 (Prohesion), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, and other automotive cyclic corrosion standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT1100 |
| Salt Spray Deposition Rate | 1.0–2.0 mL/80 cm²/h (ASTM B117 compliant range) |
| Temperature Range | 10–50 °C (Salt Fog), 25–70 °C (Dry), 25–60 °C (Humid) |
| Humidity Control | 95–100% RH (Condensation Humidity Mode) |
| Chamber Volume | 1100 L |
| Power Supply | 220–240 V, 50/60 Hz, Single Phase, Max 4.2 kW |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT600 |
| Salt Spray Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 640 L |
| Cycle Modes | Neutral Salt Spray (NSS), Prohesion™, and 100% RH Humidity Conditioning |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT600 |
| Chamber Capacity | 640 L |
| Cycle Modes | Salt Spray / Dry / 100% RH Humidity / Ambient Hold |
| Compliance | ASTM B117, ISO 9227, ISO 11997-1/2, GMW 14872, SAE J2334, VW PV1210, Ford CETP, Renault D17 2025, GB/T 10587, GB/T 2423.17/18/33 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH 1100 |
| Salt Spray Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 1103 L |
| RH Control | Yes (via air pre-conditioning system) |
| Optional Spray Function | Yes |
| Internal DI Water Requirement | Yes |
| Calibration Interval | Every 6 months (temperature & RH sensors) |
| Compliance | ASTM B117, ISO 9227, ISO 11997, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10587, VDA 621-415 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CRH 600 |
| Salt Spray Deposition Rate | 0.5–3.0 mL/(h·80 cm²) |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 640 L |
| Humidity Control | Yes (via Air Preconditioner + Fogging Humidification) |
| Compliance | GMW 14872, SAE J2334, ISO 9227, VW 20108, Ford CETP, Renault D17 2020, Volvo STD 5110, GB/T 10125 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH 600-HSC |
| Category | Cyclic Corrosion Test Chamber (CCT) with RH Control and Spray Functionality |
| Compliance | ASTM B117, ISO 9227, ISO 16701, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, Volvo STD 515, Chrysler PF-9802, GB/T 10125 |
| Humidity Control | Programmable RH (30–95% RH, ±2% RH accuracy) via air pre-conditioning system |
| Temperature Range | 10–60 °C (±0.5 °C uniformity) |
| Salt Solution Delivery | Dual-mode — atomized fog (via compressed-air-driven nozzles) and programmable liquid spray (via peristaltic pump, flow-adjustable 0–500 mL/min) |
| Nozzle Maintenance | Automated self-cleaning cycle to prevent crystallization-induced clogging |
| Heating Method | Direct air-heating (non-steam, avoids salt concentration drift) |
| Water Requirement | Deionized water (resistivity ≥5 MΩ·cm) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH1100 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| De-misting Method | Air-pressurized Exhaust |
| Temperature Range | 20–60 °C |
| Humidity Control | Integrated Air Pre-conditioning System with RH Regulation |
| Optional Spray Module | Programmable High-Volume Liquid Spray |
| Internal Solution Reservoir | 120 L (≥7-day autonomy) |
| Chamber Capacity | 1103 L |
| Sample Capacity | 240 × 75 mm × 150 mm test panels |
| Structural Load Capacity | 544 kg (uniformly distributed) |
| Compliance | ASTM B117, ISO 9227, ISO 11997-1/2, SAE J2334, GMW 14872, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, VDA 621-415 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Pressure Exhaust |
| Salt Fog Deposition Rate | 1–2 mL / 80 cm²·h |
| Temperature Range | 20–60 °C |
| Humidity Control | Yes (via Air Pre-Conditioning System) |
| Optional Spray Module | Yes |
| Chamber Volumes | 640 L (CRH600), 1103 L (CRH1100) |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, ISO 16701 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH |
| Chamber Capacity | 640 L (CRH600-HSC) / 1103 L (CRH1100-HSC) |
| Temperature Range | Ambient to 50 °C (operational control range) |
| Relative Humidity Control | 30–95% RH (with air pre-conditioning system) |
| Salt Spray Deposition Rate | Adjustable via variable-speed peristaltic pump and regulated air pressure |
| Spray Nozzle Type | Self-cleaning, corrosion-resistant ceramic nozzles |
| Internal Solution Reservoir | 120 L (supports ≥7 days unattended operation) |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, Prohesion™ protocol |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CRH |
| Compliance | ASTM B117, ISO 9227, GMW14872, SAE J2334, VW PV1210, Ford CETP, Renault D17 2025, Volvo VCS 1027, Chrysler MSJC307 |
| Humidity Control Range | 10–95% RH (programmable) |
| Temperature Range | Ambient +10°C to 50°C |
| Spray System | Air-saturated compressed air + corrosion solution (NaCl, CuCl₂, acetic acid, etc.) |
| Preconditioned Air System | Integrated air pre-conditioner for precise RH ramping |
| Programmable Spray Option | Yes |
| Controller | Microprocessor-based with dual 80-character LCD interface |
| Built-in Test Cycles | ASTM B117, Prohesion™, CCT-1/CCT-IV, GMW14872, SAE J2334, and custom multi-step cycles |
| Data Logging | Time-stamped cycle step tracking, event history, audit trail capability |
| Software Interface | Q-FOG® Control Software (optional PC connectivity) |
| Construction | Fiberglass-reinforced polymer (FRP) chamber body, corrosion-resistant stainless steel hardware |
| Safety Features | Over-temperature protection, low-level solution alarm, door interlock, leak detection |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH) |
| Humidity Control | Fully adjustable relative humidity (RH), 10–95% RH (CRH-specific capability) |
| Internal Solution Reservoir | 120 L |
| Chamber Capacity | 640 L (CRH-600) or 1103 L (CRH-1100) |
| Sample Capacity | 160 plates (75 × 150 mm) or 240 plates (75 × 150 mm) |
| Water Purity Requirement | <8 ppm TDS, resistivity >50 kΩ·cm |
| Compressed Air | 4–10 bar (60–150 psi), max. 1.7 L/s (3.5 CFM) |
| Power Supply | 208–230 V, 50/60 Hz, up to 38 A |
| Weight (dry) | 333 kg (CRH-600), 378 kg (CRH-1100) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Q-FOG CRH |
| Spray Method | Dual-mode (Atomized Salt Fog + Programmable Spray) |
| Nozzle Pressure | 0.7–1.4 bar |
| Salt Deposit Rate | 1.0–2.0 mL / 80 cm² / h |
| Temperature Range | 35–70 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH |
| Chamber Capacity | 640 L (CRH600-HSC) / 1103 L (CRH1100-HSC) |
| Temperature Range | Ambient to 70 °C (operational range per test standard) |
| Relative Humidity Control | 30–95% RH (with air pre-conditioning system) |
| Salt Spray Deposition Rate | Adjustable via precision peristaltic pump and compressed air regulation |
| Spray Nozzle Type | Corrosion-resistant, self-cleaning atomizing nozzles |
| Optional Features | Integrated spray module (high-volume liquid delivery), programmable dry/wet/humidity/cycle sequences |
| Compliance | Designed to meet ASTM B117, ISO 9227, ISO 16701, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2027, GB/T 10587, and other automotive & industrial cyclic corrosion standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH-600 |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH) |
| Internal Chamber Volume | 640 L (incl. lid) |
| Salt Solution Reservoir | 120 L |
| Sample Capacity | 160 × 75 mm × 150 mm panels |
| RH Control Range | Fully adjustable 10–95% RH (CRH model only) |
| Compressed Air Requirement | 4–10 bar, ≤1.7 L/s |
| Deionized Water Specification | <8 ppm TDS, >50 kΩ·cm resistivity |
| Power Supply | 230 V ±10%, 50/60 Hz, 32 A single-phase |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH1100 |
| Spray Mode | Continuous Atomization |
| Fog Output | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| De-fogging Method | Air-pressurized Exhaust |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 20–60 °C |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH1100 |
| Chamber Capacity | 1103 L |
| Salt Spray Deposition Rate | Adjustable via precision peristaltic pump and regulated air pressure |
| Temperature Range | 10–70 °C (operational), with rapid thermal transition capability |
| Relative Humidity Control | 10–95% RH (via integrated air pre-conditioning system) |
| Spray Function | Optional high-flow liquid spray module with user-adjustable duration and flow rate |
| Internal Water Reservoir | 120 L deionized water tank with particulate filtration and low-level alarm |
| Compliance | Designed to meet GMW 14872, SAE J2334, ISO 9227, ISO 11997, ASTM B117, ASTM G85 Annex A5 (Prohesion), VW PV1210, Ford CETP, Renault D17 2025, GB/T 2423.17, GB/T 2423.36 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH1100 |
| Chamber Capacity | 1103 L |
| Temperature Range | Ambient +10°C to 50°C (operational, adjustable per cycle phase) |
| Relative Humidity Control Range | 10% to 95% RH (±2% RH accuracy, typical) |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable via variable-speed peristaltic pump and regulated air pressure) |
| Spray Nozzle Type | Self-cleaning, corrosion-resistant ceramic nozzle array |
| Preconditioned Air System | Integrated dual-stage air pre-conditioning module for precise RH ramping and stabilization |
| Optional Features | Programmable rinse/spray module, internal LED lighting, viewing window, DI water requirement, built-in 120 L solution reservoir with level sensor and particulate filtration |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH600 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Driven Mechanical Exhaust |
| Salt Deposit Rate | 1–2 mL / 80 cm²·h |
| Temperature Range | 20–60 °C |
| Humidity Control | Integrated Preconditioned Air System with Adjustable RH (20–95% RH, typical operating range) |
| Chamber Volume | 640 L |
| Compliance | ASTM B117, ISO 9227, ISO 11997-1/2, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Volvo VCS 1027,000, Renault D17 2020, GB/T 10125 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH600 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Driven Exhaust |
| Salt Fog Deposition Rate | 1–2 mL / 80 cm²·h |
| Temperature Range | 10–80 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH600 |
| Salt Fog Deposition Rate | Adjustable and Calibratable per ASTM B117 & ISO 9227 |
| Temperature Range | 10°C to 70°C (operational, with ±0.5°C uniformity) |
| Humidity Control | 10–99% RH, programmable via integrated air pre-conditioning system |
| Cycle Programming | Multi-step sequences including salt spray, dry-off, high-humidity soak, and ambient recovery |