| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DPCZ-I |
| Price Range | USD 1,400 – 7,000 |
| Moisture Accuracy | ±0.5% |
| Amylose Content Accuracy | ±1% |
| Chalkiness Degree Accuracy | ±1% |
| Chalky Grain Ratio Accuracy | ±2% |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Consistometer |
| Construction | Stainless steel body with electropolished 2 mm stainless steel channel |
| Sample volume | 75 mL |
| Dimensions (L × W × H) | 35.6 cm × 8.9 cm × 14.0 cm (14 in × 3.5 in × 5.5 in) |
| Base plate scale division | 0.5 cm |
| Leveling | Dual adjustable leveling screws + bubble level |
| Flow gate | Spring-loaded, instantaneous release mechanism |
| Compliance | Designed to meet ASTM D1200, ISO 2555, and AOAC Official Method 956.02 for consistency testing of semi-solid food products |
| Key | Brand: ENSOUL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MFT2 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MA2 |
| Pricing | Available Upon Request |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XQ-600 |
| Price | Upon Request |
| Measurement Range | 0–300 mg KOH/100 g dry matter |
| Resolution | 0.01 mg KOH/100 g dry matter |
| Repeatability | RSD ≤ 0.3% |
| Minimum Dispensing Volume | 0.625 µL |
| Titration Modes | Rapid Titration, Precise Titration |
| Preloaded Methods | Corn, Rice (Paddy), Wheat (100 method slots) |
| Compliance | GB/T 15684–1995, GB 5510–1985, GB/T 20569–2006, GB/T 20570–2006, GB/T 20571–2006 |
| Interfaces | RS232C, Parallel Printer Port |
| Software | Embedded real-time monitoring & PC-based data management suite |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Alphatec™ FNO |
| Application | Falling Number determination per ISO 3093, AACC 56-81B, ICC 107/1, and ASTM D7827 |
| Sample Types | Wheat, Rye, Barley, Sorghum, Flour, and other cereal-based materials |
| Measurement Principle | Viscosity-based enzymatic hydrolysis of starch gel under standardized boiling conditions |
| Display | 7-inch capacitive touchscreen interface with multilingual OS support |
| Compliance | Fully aligned with GLP/GMP data integrity requirements |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatMaster II |
| Technology | X-ray Transmission |
| Sample Types | Raw, chilled, or frozen meat (bone-in or boneless |
| Detection Parameters | Fat content, mass, foreign object detection (metal, bone) |
| Compliance | Designed for food processing environments meeting EU Hygiene Regulation (EC) No. 852/2004, HACCP principles, and compatible with GMP/GLP-aligned QA workflows |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MycoFoss |
| Detection Principle | Bead-based Flow Cytometric Immunoassay |
| Sample Throughput | Up to 12 samples per run |
| Assay Time | ≤8 minutes per sample |
| Target Analytes | Aflatoxins (AFB1, AFB2, AFG1, AFG2), Deoxynivalenol (DON), Zearalenone (ZEA), Ochratoxin A (OTA), T-2 Toxin, Fumonisins (FB1, FB2, FB3) |
| Sample Types | Ground corn, wheat, and barley |
| Automation Level | Fully automated sample preparation, assay execution, and data reporting |
| Compliance Support | Audit-trail enabled, 21 CFR Part 11–ready software architecture, GLP/GMP-aligned workflow design |
| Data Management | Integrated instrument control, result traceability, PDF report generation, and CSV export |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | GMK-835N |
| Price Range | USD 1,400 – 7,000 |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | SAM-700S |
| Measurement Principle | Refractive Index (Brix) & Electrical Conductivity (Acidity) |
| Brix Range | 0–35.0% w/w |
| Acidity Range | 0–3.50% (as citric acid) |
| Brix Resolution | 0.1% |
| Acidity Resolution | 0.01% |
| Brix Accuracy | ±0.2% |
| Acidity Accuracy | ±0.05% |
| Temperature Compensation | Automatic (ATC, 10–40 °C) |
| Power Supply | 9 V alkaline battery (1×) |
| Dimensions | 200 × 132 × 62 mm |
| Weight | ~2.0 kg |
| Accessories | Pipette, pipette tips, fruit juice extractor tool, dilution cup, syringe, light-blocking cap, user manual |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | SAM-706AC |
| Measurement Principle | Conductivity (Acidity), Refractometry (Brix) |
| Brix Range | 0.0–45.0% |
| Acidity Range (as citric acid) | 0.00–3.50% |
| Accuracy | ±0.2% Brix, ±0.05% acidity |
| Resolution | 0.1% Brix, 0.01% acidity |
| Temperature Compensation | Automatic, 5–70 °C |
| Measurement Time | 3 s (Brix), 8 s (acidity) |
| Power Supply | 9 V alkaline battery or AC 220 V/60 Hz |
| Sample Compatibility | Citrus, grape, apple, strawberry, peach, kiwifruit, tomato, plum, cherry, raspberry, mulberry, pomegranate, pineapple, mango, pear, orange, etc. |
| Accessories | 30 mL syringe sampler, filtration unit, pipette with tips, diluent vial, shade hood, anti-theft lock, user manual, AC adapter |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Solution Index Mixer |
| Motor Speed | 2800 rpm (drive), 3600 rpm (impeller) |
| Impeller | 16-blade stainless steel, clockwise rotation, flat side down, upward tilt from right to left |
| Vessel | 500 mL borosilicate glass beaker |
| Standards Compliance | ADPI, DLG, DIN ISO 8156 |
| Dimensions | 38 × 26 × 25 cm |
| Power | 65 W (220 V, 50 Hz) |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | TDT |
| Standards Compliance | DIN ISO 8967, ISO 3953, ISO 8460, ISO 9161, ISO 787-11, ASTM D4164, ASTM D4781, ASTM B527, USP <616> Method I, IDF 134 |
| Predefined Programs | 5 |
| Tap Count Range | 5–9995 cycles |
| Tap Rate | 250 taps/min |
| Tap Amplitude | 3 mm |
| Included Accessory | 250 mL calibrated graduated cylinder |
| Category | Food Quality Detector for Powder Bulk Density and Tap Density Measurement |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Imported Instrument |
| Model | VAPODEST 200 |
| Power | 2200 W |
| Supply Voltage | 220 V AC, 50/60 Hz |
| Water Consumption | ~5 L/min |
| Distillation Time (for N-nitrosamines) | 6–10 min |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Weight | 25 kg |
| Compliance | Fully compliant with GB 5009.26–2023 |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GMK-835F/835N |
| Price Range | USD 1,400 – 7,000 |
| Measurement Principle | Capacitive Sensing |
| Measurement Range | 0.00–3.50% (as citric acid equivalent) |
| Resolution | 0.01% |
| Accuracy | ±0.5% |
| Temperature Compensation | Automatic (0–40 °C) |
| Calibration | Auto-calibration with pre-stored fruit-specific calibration curves |
| Power Supply | 9 V alkaline battery (IEC 6LR61) |
| Dimensions | 154 mm (W) × 108 mm (L) × 43 mm (H) |
| Weight | 1.0 kg |
| Predefined Fruit Profiles | 12 (Citrus, Grape, Apple, Orange, Pineapple, Pear, Strawberry, Kiwi, Plum, Peach, Mango, Tomato) |
| Selectable Fruit Modes | 3 per device configuration |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorFlex EZ |
| Measurement Principle | 45°/0° Geometry Reflectance Spectrophotometry |
| Illuminant | D65, A, C, F2, F7, F11 |
| Observer Angle | 10° |
| Wavelength Range | 400–700 nm |
| Optical Resolution | 10 nm |
| Repeatability | ΔE*ab < 0.08 (for white tile, 10 readings) |
| Interface | USB 2.0 |
| Software Compatibility | EasyMatch QC v5.0+ |
| Compliance | ASTM E308, ISO 7724, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LSXE Tomato |
| Optical Geometry | 45°/0° (45-degree annular illumination, 0-degree viewing) |
| Aperture Size | 44 mm |
| Compliant Standards | ASTM E313-96, USDA Tomato Color Grading Protocol, BCR Certified Reference Tiles |
| Built-in Tomato-Specific Indices | Tomato Color Score, Tomato Juice Score, Tomato Catsup Score, Tomato Paste Score, Tomato Sauce Score, Lycopene Estimation (457 nm Brightness), A/B Ratio, Hunter L,a,b (C/2° & D65/10°) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectraTrend-HT Online Paper Color & Height Measurement System |
| Price Range | USD 26,000 – 39,000 (FOB) |
| Measurement Principle | Reflectance-based spectrophotometry (CIE-compliant, D65/10°) |
| Optical Geometry | 45°/0° (annular illumination, directional viewing) |
| Spectral Bandwidth | 10 nm |
| Wavelength Range | 400–700 nm |
| Measurement Distance | Up to 100 mm (4 in) |
| Sampling Rate | 5 Hz |
| IP Rating | NEMA 4 / IP56 |
| Interface | Ethernet (TCP/IP), PLC-compatible digital I/O |
| Software Platform | HunterLab EasyMatch QC v5.0+ (FDA 21 CFR Part 11 compliant audit trail option) |
| Brand | Junfang Physical & Chemical |
|---|---|
| Origin | Beijing, China |
| Model | JFQ-3150H |
| Respiratory Chamber Options | Φ100×140 mm and Φ150×250 mm |
| Simultaneous Measurement | CO₂ concentration, O₂ concentration, temperature, relative humidity |
| Dual Respiration Calculation Modes | CO₂ evolution rate and O₂ consumption rate |
| Application Environment | Ambient storage, cold storage, controlled atmosphere (CA) storage, retail refrigerated display units |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-1100M |
| Price Range | USD 1,400 – 7,200 |
| Detection Parameters | Moisture (0.0–27.0%), Fructose + Glucose (0.0–76.0%), Sucrose (0.0–12.0%), Acidity (0.0–100.0 mL/kg), Hydroxymethylfurfural (HMF) (0.0–100.0 mg/kg), Diastase Activity (0.0–25.0 mL/(g·h)) |
| LOD | Moisture: 12.0%, Fructose + Glucose: 13.0%, Sucrose: 3.0%, Acidity: 4.0 mL/kg, HMF: 1.0 mg/kg, Diastase Activity: 1.0 mL/(g·h) |
| Accuracy | ±2% |
| Interface | RS-232 / USB |
| Display | Backlit LCD with Chinese UI |
| Data Handling | Onboard storage, PC connectivity, statistical analysis |
| Brand | Jinggong (JNGON) |
|---|---|
| Origin | Shanghai, China |
| Model | JZ-3100 |
| Heating Units | 6 independent positions |
| Touchscreen Display | 7-inch color LCD (main unit), 5-inch color LCD (steam generator) |
| Steam Generator Power | 3000 W (adjustable) |
| Individual Heating Power | 0–600 W per position |
| Distillation Rate | 2–12 mL/min |
| Steam Flow Control | Electromagnetic + pinch valve with atmospheric venting |
| Automatic Endpoint Detection | Dual-mode (pressure-weight sensing + timer), range: 1–500 g (mL) |
| Nitrogen Purge | Optional, 0–2 L/min per port, individually controllable |
| Cooling System | Closed-loop compressor chiller, temperature range: ambient to 35 °C, outlet coolant ≤15 °C |
| Anti-suckback Protection | Pressure-responsive solenoid valve + automatic steam-line venting |
| Flask Compatibility | 250 mL or 500 mL round-bottom flasks ×6 (customizable) |
| Total Power Consumption | 3600 W (adjustable) |
| Dimensions (Main Unit) | 930 × 450 × 720 mm (L×W×H) |
| Dimensions (Steam Generator) | 350 × 500 × 540 mm (L×W×H) |
| Water Reservoir Capacity | 16 L with level indicator and auto-refill alert |
| Compliance Standards | GB 5009.34–2022 (SO₂, ion chromatography method), GB 5009.120–2016 (sodium/calcium propionate), GB 5009.277–2016 (sodium diacetate) |
| Brand | JWP |
|---|---|
| Origin | Japan |
| Model | CA-Hi |
| Measurement Principle | Near-Infrared (NIR) Spectroscopy |
| Sample Throughput | ≤80 seconds per measurement |
| Sample Types | Solid, Powder, Liquid (transmission/reflection modes) |
| Data Output | Energy (kcal/100g), Protein (%), Fat (%), Carbohydrates (%), Moisture (%) |
| Connectivity | USB 2.0 |
| Software | CA-Hi Control Suite v3.2 (Windows-compatible) |
| Compliance | ISO 17025-aligned operation, supports GLP audit trails, FDA 21 CFR Part 11–ready data logging |
| Brand | JWP |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CA-HM |
| Pricing | Available Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AT-710 |
| Price Range | USD 6,800 – 13,600 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | RA-600 |
| Price Range | USD 7,000–14,000 |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | AlveoPC |
| Compliance | AACC 54-30.02, ICC 121, NF EN ISO 27971, GB/T 14614.4 |
| Application Domain | Wheat breeding, flour milling, grain procurement, food processing, official quality inspection |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | CD1 |
| Type | Laboratory-scale roller mill for wheat flour milling simulation |
| Application | Flour yield determination, short-patent milling flow optimization, millability assessment |
| Compliance | Designed per ISO 27990 (Cereal and cereal products — Determination of flour yield), aligned with AACC Method 26–50A and ICC Standard No. 171 |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | Mixolab 2 |
| Compliance | ISO 17718:2013, AACC 54-60-01, ICC 173-1, GOST R 54498-2011, GOST R ISO 17718-2015, GB/T 37511-2019 |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | Rheo F4 |
| Application | Fermentation & Dough Rheology Analysis for Gluten-Free, Whole Wheat, and Pre-Fermented Products |
| Category | Food-Specific Quality Instrumentation |
| Compliance Context | Designed for ISO 21502, AACC Method 54-10A, and ASTM D7908 (Rheological Characterization of Leavened Dough Systems) |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | SDmatic 2 |
| Measurement Principle | Amperometric iodine binding assay (Medcalf & Gilles method) |
| Compliance | NF EN ISO 17715:2015, ICC 172, AACC 76-33.01, GB/T 31577-2015 |
| Sample Requirement | 1 g flour |
| Analysis Time | <10 min per test |
| Display | 7-inch color touchscreen |
| Data Storage | Internal database + USB export |
| Connectivity | Ethernet/LAN for LIMS integration |
| Electrode Maintenance | User-replaceable |
| Firmware Update | Online (via network) or offline (via USB drive) |
| Software Features | Protocol customization (flour mass, iodine reaction time, measurement duration), unit selection, guided workflow, learning mode, timer |