| Brand | Palas |
|---|---|
| Origin | Germany |
| Model | 2050X / 2100X / 2200X |
| Particle Size Range | 8–1200 nm |
| Classification Principle | Differential Electrical Mobility (DEMC, per ISO 15900) |
| Neutralizer Type | Integrated X-ray Neutralizer (XRC 049) |
| Scan Time | ≤30 s per distribution |
| Channels | Up to 64 per decade (logarithmic) |
| Display | 7-inch capacitive touchscreen GUI |
| Data Logging | Built-in recorder with linear/log scaling |
| Interfaces | USB, LAN, WLAN, RS-232/485 |
| Compatibility | Interoperable with third-party DMAs, CPCs, and aerosol electrometers |
| Software | Palas Evaluation Suite with statistical analysis, export (CSV, PDF), and audit-trail-ready data management |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Parker Balston NG Series |
| Price Range | USD 1,400 – 2,800 (FOB) |
| Analyte Scope | Trace Impurity Analysis in Ultra-High-Purity Gases (He, H₂, N₂, CO₂, O₂, CH₄, H₂O, CO, etc.) |
| Brand | PMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Lasair III |
| Instrument Type | Handheld |
| Flow Rate Options | 28.3 L/min, 50 L/min, 100 L/min |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±0.01 s |
| Repeatability | ±0.01% RSD |
| Size Distribution Accuracy | ±0.01 µm (for calibrated channels) |
| Indication Accuracy | ±0.001 particles/m³ (at reference concentration) |
| Brand | Pegasor |
|---|---|
| Origin | Finland |
| Model | Mi2 |
| Instrument Type | Online |
| Detection Principle | Electrostatic Detection with Integrated Heated Sampling |
| Particle Size Range | ~1 nm – 2.5 µm |
| Mass Concentration Range | 1 µg/m³ – 250 mg/m³ (at T = −20°C to +700°C) |
| Number Concentration Range | 10² – 10⁸ particles/cm³ (derived) |
| Sampling Frequency | 100 Hz (24-bit ADC) |
| Response Time | ≤ 0.2 s |
| Heated Sampling Line | 2 m, maintained at 200 °C |
| Operating Ambient Temperature | −20 °C to +55 °C |
| Power Supply | 24 VDC / 16 A (Mi2 unit) |
| Dimensions (L×W×H) | 798 × 484 × 208 mm |
| Weight | ~29 kg |
| Display | 4-inch color touchscreen |
| Outputs | 4-channel 4–20 mA analog |
| Interface | USB for PPS software connectivity |
| Auto-zero function | Yes |
| Compliance | Designed for EN 16454, ISO 8502-12, and EPA Method 202–compatible deployment in regulatory-grade exhaust monitoring |
| Brand | Pegasor |
|---|---|
| Origin | Finland |
| Model | PPC |
| Instrument Type | Handheld |
| Flow Rate | High-flow (5.5 L/min) |
| Concentration Range (PN) | 0–100,000,000 #/cm³ |
| Size Range (PN & LDSA) | 10 nm–1 µm |
| Size Range (PM & Dp) | 10–300 nm |
| Detection Sensitivity | 30–1,500 #/cm³ |
| Response Time | 0.2 s |
| Sampling Frequency | 10 Hz / 1 Hz / 60 s |
| Operating Temperature | 5–40 °C |
| Sample Gas Temperature | up to 600 °C |
| Heated Sensor Module | 200 °C |
| Integrated VPR | Yes |
| Power Input | 100–260 VAC, 50–60 Hz |
| Power Consumption | 140 W (steady), 1200 W (startup) |
| Dimensions | 464 × 175 × 339 mm |
| Weight | 9.1 kg (without heated sampling line) |
| Brand | Pegasor |
|---|---|
| Origin | Finland |
| Model | PPS-M |
| Particle Size Range | ~nm–2.5 µm |
| Mass Concentration Range | 1 µg/m³–500 mg/m³ (dependent on sample gas temperature) |
| Number Concentration | Supported via Faraday cup current differential |
| Response Frequency | Up to 100 Hz |
| Operating Sample Gas Temperature | Standard version up to 200 °C |
| Ambient Temperature Range | −20 °C to +50 °C |
| Sample Gas Pressure | 1–10 bar (absolute) |
| Power Consumption | 6 W |
| Output Interface | USB (standard), analog output optional |
| Sensor Housing Material | Stainless steel |
| Dimensions | 400 mm (length) |
| Weight | 2.6 kg |
| Gas Inlet/Outlet | G1/4″ (inlet), G3/8″ (outlet), G1/8″ (clean air supply) |
| Brand | Pentol |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PENTOL |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Turbidimetric Spectrophotometry |
| Measurement Range | 1–200 ppm SO₃ |
| Accuracy | ±5% of reading (calibrated range) |
| Repeatability | ±2% |
| Response Time (90% FSD) | <120 s |
| Drift Stability | ±5% over 30 days |
| T90 Delay | ~60 s |
| Sample Flow Control | Precise dual-pump liquid/gas flow regulation |
| Absorbent | Aqueous isopropanol solution |
| Reaction Chemistry | SO₃ → H₂SO₄ → SO₄²⁻ → BaClO₄⁻ complex formation |
| Reagent Consumption | 0.25–2 cm³/h (adjustable) |
| Operating Ambient Temperature | 0–40 °C |
| Power Supply | 230 V / 110 V, 50/60 Hz, 350 W |
| Analyzer Module | 19″ rack, 6U height, 500 mm depth, 27 kg |
| Control Module | 19″ rack, 4U height, 500 mm depth, 13 kg |
| Probe Length Options | 1.0, 1.2, 1.5, 2.0 m |
| Analog Output | 4–20 mA (isolated) |
| Digital Interface | RS232 (optional, factory-configurable) |
| Brand | Pentol |
|---|---|
| Origin | Germany |
| Model | SO3 Generator |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Component |
| Measurement Accuracy | ±5% |
| Repeatability | ±5% |
| Response Time | 1 s |
| Long-Term Stability | ±5% |
| Target Analyte | SO₃ |
| Catalyst | V₂O₅ |
| SO₂ Feed Rate | 2–200 L/h |
| Air Dilution Flow | 100–5,000 L/h |
| Max Operating Temperature | 1000 °C |
| Heating Rate (to 500 °C, no load) | 20 K/min |
| Power Supply | 400 V / 30 A / 7 kW |
| Dimensions (L×W×H) | 1800 × 1400 × 1200 mm |
| Weight | 429 kg |
| Brand | Pergam |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LMC-G2-DL |
| Detection Range | 30 m |
| Measurement Range | 1–50,000 ppm·m |
| Sensitivity (at 30 m) | 125 ppm·m |
| Real-Time Data Transmission | Yes |
| Onboard Data Storage | Yes |
| Integrated GPS | Yes |
| Laser Wavelength | 1.65 µm (eye-safe) |
| Dimensions | 70 × 179 × 42 mm |
| Weight | 0.53 kg (base unit), 1.0 kg (DL configuration) |
| Brand | Pergam |
|---|---|
| Origin | Switzerland |
| Model | LMF |
| Detection Range | 100 m |
| Measurement Range | 1–50,000 ppm·m |
| Sensitivity (at 30 m) | 10 ppm·m |
| Sensitivity (at 50 m) | 20 ppm·m |
| Sensitivity (at 70 m) | 80 ppm·m |
| Sensitivity (at 100 m) | 150 ppm·m |
| Real-Time Data Transmission | Yes |
| Onboard Data Storage | Yes |
| Integrated GPS | Yes |
| Laser Wavelength | 1.65 µm (eye-safe) |
| Dimensions | 130 × 95 × 140 mm |
| Weight | 1.7 kg |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom Version |
| Pricing | Upon Request |
| Detection Gases | Hydrogen, Combustible Gases (e.g., CH₄), Oxygen, Ammonia |
| Measurement Ranges | 0–100% LEL (H₂ & combustibles), 0–25% O₂, 0–100 ppm NH₃ |
| Accuracy | ≤±3% FS (H₂ & combustibles), ≤±2% FS (O₂), ≤±5% FS (NH₃) |
| T90 Response Time | ≤30 s (H₂), ≤60 s (combustibles, O₂, NH₃) |
| Certification | CCC (China Compulsory Certification) |
| Design | Explosion-Proof (Ex d IIB T6 Gb), Modular Controller Architecture, Integrated Sampling & Pre-treatment Compatibility |
| Environmental Resistance | Vibration-resistant, Salt Mist Resistant |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom10 |
| Pricing | Upon Request |
| Gas Measurement Range | NH₃ (0–10,000 ppm), NO (0–3,000 ppm), NO₂ (0–3,000 ppm), N₂O (0–1,000 ppm), CH₃OH (0–2,000 ppm), CH₂O (0–1,000 ppm), CH₄ (0–30,000 ppm), O₂ (0–24% vol), CO (0–2,000 ppm), CO₂ (0–14% vol), SO₂ (0–1,000 ppm) |
| Accuracy | ≤ ±2% FS for all listed gases |
| Detection Technologies | NDIR, UV-DOAS, TDLAS |
| Application Scope | Dual-fuel diesel, LNG, methanol, and ammonia-fueled marine engines |
| Compliance Support | ASTM D6595, ISO 8178-4, IMO MARPOL Annex VI Tier III test protocols |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Custom-1 |
| Pricing | Upon Request |
| Principle | Laser Raman Spectroscopy |
| Form Factor | Portable |
| Detection Range | H₂: 0–100% vol, O₂: 0–20% vol, N₂: 0–100% vol |
| Accuracy | ≤0.3% vol (0–10% range), ≤3% FS (10–100% range) |
| Response Time | Default 30 s, Adjustable |
| Power | Integrated Rechargeable Battery (≥8 h runtime) |
| Dimensions | Approx. 40 × 30 × 25 cm (l×w×h), Luggage-Sized Enclosure |
| Sampling | Built-in Diaphragm Pump with External Gas–Liquid Separator |
| Compliance | Designed for IAEA Safety Standards, NRC Regulatory Guidance (NUREG-0711), and ISO 17025 Traceability Framework |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom T |
| Pricing | Upon Request |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Detection Method | Wavelength Modulation Spectroscopy (WMS) with Digital Lock-in Amplification |
| Gas Species | H₂O (dew point), O₂, HF, NH₃, CO, CO₂, H₂S |
| Concentration Ranges | 0–1000 ppm (H₂O), 0–25% vol (O₂), 0–10 ppm (HF), 0–100 ppm (NH₃, CO, CO₂), 0–2% vol (CO₂), 0–100 ppm (H₂S) |
| Accuracy | ±3% FS for all listed gases |
| Detection Limits | 0.1 ppm (H₂O, HF, NH₃, CO, CO₂), 0.1% vol (O₂), 0.01 ppm (H₂S), 0.5 ppm (H₂S — alternate spec) |
| Form Factors | Portable, In-situ Online, Ambient-Temperature & High-Temperature Configurations |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Custom Model 5 |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Customized 4 |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Customized 7 |
| Quotation | Upon Request |
| Repeatability | 2% F.S. |
| Resolution | 0.01% VOL |
| Response Time | ≤30 s |
| CO₂ Measurement Range | (0–10)% VOL |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Accuracy | ±2% F.S. |
| Operating Ambient Temperature | −20 °C to +55 °C |
| Brand | PERIC |
|---|---|
| Model | EMO-HJV |
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Power Supply | AC 220 V ±10%, with built-in rechargeable battery supporting ≥6 hours operation during power outage |
| Sampling Method | Active pump-driven aspiration with integrated hydrophobic dust/water filter |
| Communication Interfaces | 4G LTE (Cat 1), Ethernet (RJ45), LoRaWAN (optional), RS485 (Modbus RTU) |
| Local Storage | MicroSD card slot (up to 32 GB) |
| Data Upload Protocol | MQTT/HTTP over TLS 1.2 |
| Remote Capabilities | OTA firmware update, remote zero/span calibration, drift compensation algorithm |
| Data Integrity | 断点续传 (Resume-on-Interruption) with local queue buffering |
| Expandability | Optional meteorological module (wind speed/direction, temperature, humidity, pressure, rainfall) |
| Compliance | Designed per IEC 61326-1 (EMC), EN 50270 (gas detection equipment), and aligned with technical requirements of China’s HJ 653–2013 and HJ 93–2013 for ambient air monitoring stations |
| Detection Parameters & Ranges | PM₂.₅ (0–1000 µg/m³, resolution: 1 µg/m³), PM₁₀ (0–1000 µg/m³, resolution: 1 µg/m³), CO (0–12.5 µmol/mol, resolution: 0.01 µmol/mol), SO₂ (0–1000 nmol/mol, resolution: 1 nmol/mol), NO₂ (0–1000 nmol/mol, resolution: 1 nmol/mol), O₃ (0–1000 nmol/mol, resolution: 1 nmol/mol), VOCs (0–50 µmol/mol, resolution: 1 nmol/mol) |
| Sensor Technologies | Optical scattering (PM), electrochemical (CO, SO₂, NO₂, O₃), photoionization detection (PID) for VOCs, NDIR for CO₂ (optional) |
| Brand | PERIC |
|---|---|
| Model | EMO-YC |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Certification | CCEP, CPA, CMA |
| Measurement Principle | Laser Light Scattering |
| Particle Range | TSP/PM10/PM2.5: 0–10 mg/m³ |
| LOD | 0.001 mg/m³ |
| Accuracy | ±10% |
| Temp. Range | −40–80 °C (±0.3 °C) |
| RH Range | 0–100% RH (±3% RH) |
| Wind Speed | 0–30.0 m/s (0.1 m/s res.) |
| Wind Direction | 0–360° (8-sector) |
| Barometric Pressure | 300–1100 hPa (1 Pa res.) |
| IP Rating | IP54 |
| Power Input | AC 220 V |
| Data Transmission | 4G Cellular + Optional Wired Ethernet |
| Operating Temp. | −20–70 °C |
| Humidity Limit | ≤95% RH non-condensing |
| Brand | PERIC |
|---|---|
| Model | EO-VD |
| Detection Principle | Photoionization Detection (PID) |
| Measurement Target | Total Volatile Organic Compounds (TVOC), including benzene, aliphatic hydrocarbons, and alkanes |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Protection Rating | IP66 |
| Explosion Protection | Ex d IIC T6 Gb |
| Communication Interface | 4G LTE + Ethernet (RJ45) |
| Alarm Output | Visual (LED strobe) + Audible (≥85 dB at 1 m) |
| Data Protocol | HJ 212–2017 (China EPA Standard) |
| Operating Temperature | −10 °C to +55 °C |
| Relative Humidity | ≤93 % RH (non-condensing at 25 °C) |
| Atmospheric Pressure Range | 86–106 kPa |
| Response Time (T90) | ≤20 s |
| Accuracy | ±10 % of Full Scale (FS) |
| Display | High-resolution color LCD (≥3.5″, 320×240 pixels) |
| Sensor Configuration | Triple-sensor simultaneous monitoring (customizable VOC selectivity) |
| Calibration Gas | Isobutylene (default), traceable to NIST or equivalent national standards |
| Typical Measurement Ranges | 0–20, 0–50, 0–200, 0–2000 μmol/mol or 0–50, 0–125 mg/m³ (selectable) |
| Display Resolution | 0.1 or 1 μmol/mol |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | G-WA10 |
| Pricing | Upon Request |
| Detection Principles | Electrochemical, Infrared (IR), Catalytic Combustion, Thermal Cracking + IR |
| Supported Gases | >30 toxic, flammable, and corrosive gases including NH₃, NF₃, SiH₄, AsH₃, B₂H₆, PH₃, H₂S, Cl₂, HF, HCl, HBr, SO₂, O₃, CO, NO, O₂, CH₄, C₂H₂, C₂H₄, C₃H₆, H₂, D₂, C₄F₆, CH₃F, CH₂F₂, COS, IPA, TEOS, GeH₄, ClO₂, CH₃ClO₂S |
| Sampling | Integrated diaphragm pump with flow & pressure monitoring and auto-adaptive regulation |
| Sensor Architecture | Modular, hot-swap intelligent sensors with offline calibration capability |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GAF X8-II |
| Pricing | Upon Request |
| Display | 4.3-inch HD TFT LCD |
| Communication | LoRa wireless protocol (sub-GHz ISM band, up to 5 km line-of-sight range) |
| Output Interface | Digital output (isolated relay or 4–20 mA configurable) |
| Application Domain | Confined-space occupational health monitoring, tunneling (e.g., shield TBM construction), underground infrastructure safety management |
| Compliance Context | Designed for deployment in environments requiring adherence to OSHA 1910.120 (HAZWOPER), ISO 17025-accredited field measurement workflows, and GLP-aligned data integrity practices |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GAP X2 P |
| Price | Upon Request |
| Detection Gases | Combustible Gas (EX), Hydrogen Sulfide (H₂S), Carbon Monoxide (CO), Oxygen (O₂) |
| Measurement Ranges | 0–100% LEL (EX), 0–100 ppm (H₂S), 0–1000 ppm (CO), 0–30% VOL (O₂) |
| Accuracy | ≤±5% FS (EX), ±10% (CO), ±5 µmol (H₂S) |
| Response Time | ≤45 s |
| Operating Temperature | −20 °C to +50 °C |
| Dimensions & Weight | 160 × 80 × 60 mm / 0.4 kg |
| Display | 3.5″ IPS, 320 × 480 resolution, bilingual (English/Chinese) |
| Power | 4600 mAh Li-ion battery, standby >9 h |
| Ingress Protection & Certification | IP66, Ex ib IIB T3 Gb |
| Alarm Modes | Audible (≥85 dB), visual (high-brightness LED), and vibration |
| Data Logging | 3000-event alarm memory |
| Sampling Method | Integrated micro-diaphragm pump (pump-suction) |
| Charging Interface | Micro-USB, compatible with portable power banks |
| Brand | PERIC |
|---|---|
| Model | GAP X4 |
| Gas Detection Channels | CH₄ (0–100% LEL), O₂ (0–30.0% vol), CO (0–500 ppm), H₂S (0–100 ppm) |
| Detection Principles | Catalytic combustion (CH₄), electrochemical (O₂, CO, H₂S) |
| Sampling Method | Diffusion |
| Response Time (T₉₀) | ≤60 s for all gases |
| Accuracy | ±5% FS (CH₄), ±3% FS (O₂), ±10% relative (CO, H₂S) |
| Display Resolution | 1% LEL / 0.1% vol / 1 ppm / 1 ppm |
| Alarm Thresholds (Configurable) | CH₄: 25% LEL |
| O₂ | Low 19.5% vol, High 23.5% vol |
| CO | 24 ppm |
| H₂S | 18 ppm |
| Power | Rechargeable 3.7 V Li-ion battery (103450 type) |
| Operating Temp | −10 °C to +55 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Ingress Protection | IP65 |
| Explosion Protection | Ex ib IIB T3 Gb per GB 3836.1–2010 & GB 3836.4–2010 |
| Brand | PERIC |
|---|---|
| Model | GAP-D10 |
| Type | Portable Gas Analyzer |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measurand | NH₃ |
| Range | 0–100 ppm / 0–1000 ppm (switchable) |
| Detection Limit | <50 ppb (typical, 1σ, 1-s averaging) |
| Sampling Flow Rate | ≥2.8 L/min |
| Response Time (T₉₀) | ≤30 s |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95 % RH (non-condensing) |
| Accuracy | ≤±1 % FS |
| Power Supply | 220 V AC, 50 Hz |
| Enclosure Rating | IP54 |
| Optical Path | Heated Multi-Pass Gas Cell |
| Signal Processing | Digital Lock-in Amplifier with 2f-WMS Demodulation |
| Brand | PERIC |
|---|---|
| Model | GAP-O3 |
| Measurement Principle | UV Absorption (254 nm) |
| Detection Range | 0–1000 nmol/mol |
| Detection Limit | ≤1 nmol/mol |
| Accuracy | ±3% FS |
| Repeatability | ≤1% |
| Response Time (T90) | ≤20 s |
| Zero Drift (4 h) | ±2 nmol/mol |
| Span Drift (4 h) | ±4 nmol/mol |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Display | 5-inch capacitive touchscreen |
| Power Supply | DC 12 V (with internal rechargeable Li-ion battery) |
| Compliance | Designed for continuous ambient and industrial process monitoring per ISO 13964, ASTM D5012, and EPA Reference Method EQOA-01 |
| Brand | PERIC |
|---|---|
| Model | GHB-X4 |
| Gas Detection Channels | O₂, CO, H₂S, Combustible Gas (CH₄-calibrated) |
| Measurement Principle | Electrochemical (CO, H₂S), Catalytic Bead (Combustible), Zirconia/Galvanic (O₂) |
| Power Supply | 3.7 V Li-ion (Detector: 5000 mAh |
| Magnetic Battery Pack | 27,000 mAh) |
| Intrinsic Safety Rating | Ex ib IIC T3 Gb per GB/T 3836.1–2021 & GB/T 3836.4–2021 |
| Operating Frequency Band | 410.15–493.125 MHz (default 430.125 MHz) |
| Max Transmit Power | 22.0 dBm |
| Receiver Sensitivity | −147 dBm (typ.) |
| LoRa Modem | SX1262-based |
| Network Topology | Self-organizing multi-hop mesh via repeaters |
| Default Upload Interval | 5 min |
| Standby Duration | ≥24 h (detector only), ≥7 days (with magnetic battery pack) |
| Charging Protocol Support | QC3.0 / FCP / SCP / VOOC / AFC (18 W fast charge) |
| Alarm Output | Dual-tone voice alert + dual-color LED flash + local buzzer |
| Environmental Rating | IP65 (detector unit) |
| Compliance | Meets GB/T 3836 series for intrinsic safety |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GX-C100X |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | OX-01 |
| Pricing | Available Upon Request |
| Oxygen (O2) Detection Principle | Zirconia Electrochemical Cell |
| O2 Range | 90–100 % vol |
| O2 Resolution | 0.01 % |
| CO2 Detection Principle | NDIR (Non-Dispersive Infrared) |
| CO2 Range | 0–2000 ppm |
| CO2 Resolution | 0.1 ppm |
| CO Detection Principle | Electrochemical Sensor |
| CO Range | 0–50 ppm |
| CO Resolution | 0.1 ppm |
| Cl₂ Detection Principle | Electrochemical Sensor |
| Cl₂ Range | 0–10 ppm |
| Cl₂ Resolution | 0.1 ppm |
| Dew Point Temperature Measurement Principle | Capacitive Hygrometry |
| Dew Point Range | –60 to +20 °C |
| Dew Point Resolution | 0.01 °C |
| Particulate Matter (PM) Detection Principle | Laser Light Scattering |
| PM Range | 0–1 mg/m³ |
| PM Resolution | 0.001 mg/m³ |
| Display | 5.6-inch high-resolution TFT LCD |
| Data Logging | Internal storage with timestamped records |
| Portability | Handheld, battery-operated design for field deployment |
| Brand | PERIC |
|---|---|
| Model | PR-CEMS-100 |
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Measurement Principles | UV Differential Optical Absorption Spectroscopy (UV-DOAS), Non-Dispersive Infrared (NDIR), Electrochemical Sensing |
| Measured Gases | SO₂, NO, NO₂, CO, CO₂, O₂, CH₄ (optional) |
| Sample Flow Rate | 60–100 L/min |
| Response Time | ≤30 s |
| Accuracy | ≤±2% FS |
| Zero/ Span Drift | <±2% FS/week |
| S/C Ratio Calculation | Supported |
| Environmental Rating | Marine-grade (salt fog, vibration, acceleration/deceleration) |
| Compliance | MARPOL Annex VI, GB 15097–2016, GD01–2011 |
| Certifications | Recognized by Major Classification Societies (e.g., CCS, DNV, LR, ABS) |
| Output Interfaces | 4–20 mA analog, Modbus TCP/RTU |
| Optional Enclosure | Climate-controlled cabinet with HVAC |