| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SERES 2000 As |
| Instrument Type | Online Water Quality Analyzer |
| Target Analyte | Total Arsenic (As) |
| Detection Principle | High-Temperature Oxidation Coupled with Ternary Complexation Spectrophotometry |
| Wavelength | 545 nm |
| Reagent Delivery | Infrared Photoelectric Precision Metering System |
| Sample Introduction | Non-Contact Peristaltic Sampling |
| Tubing Material | Modified PTFE |
| Digestion System | High-Pressure/High-Temperature Acid Oxidation |
| Temperature Control Accuracy | ±0.3 °C |
| Compliance | Designed for ISO 10566, EPA Method 200.8 (adapted), and GB/T 32217–2015 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | XHAN-90B |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ammonia Gas-Sensing Electrode Method |
| Measurement Range | 0–1000 mg/L NH₃–N (adjustable in multiple sub-ranges) |
| Detection Limit | 0.05 mg/L NH₃–N |
| Response Time | < 3 minutes (t₉₀) |
| Sample Requirements | Particulate concentration ≤ 10 mg/L, particle size < 0.1 mm (filtration not required) |
| Calibration | Automated two-point calibration (zero/span) |
| Data Storage | ≥ 90 days of high-resolution time-stamped records (1-min to 1-h intervals configurable) |
| Communication Interfaces | 4–20 mA analog output, RS485 serial interface, MODBUS RTU protocol support |
| Remote Access | TCP/IP-enabled for web-based monitoring and configuration |
| Maintenance Features | Automatic electrode cleaning cycle, reagent level monitoring, fault diagnostics with event logging |
| Compliance | Designed to meet ISO 15681-2:2022 (Water quality — Determination of phosphorus and nitrogen compounds — Part 2: Ammonium — Electrode method), supports GLP/GMP data integrity requirements including audit trail and user access control |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SERES 2000 Mn |
| Instrument Type | Online Analyzer |
| Detection Principle | Spectrophotometry (Formaldehyde Oxime Method with High-Temperature Oxidation) |
| Target Analyte | Manganese (Total Mn) |
| Analysis Cycle Time | ≤40 min |
| Accuracy/Precision | ±10% of Full Scale |
| Resolution | 0.01 mg/L |
| Wavelength | 470 nm |
| Compliance | Designed for continuous unattended operation in industrial and municipal wastewater monitoring environments |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | SERES 2000 TP |
| Measurement Parameter | Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | UV-Catalyzed Alkaline Persulfate Oxidation Coupled with Molybdenum Blue Spectrophotometry |
| Measurement Range | 0–0.5 / 0–5 / 0–10 / 0–50 mg/L P (selectable ranges) |
| Accuracy | ±3% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | ≤0.01 mg/L |
| Compliance Standard | HJ/T 103–2003 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XHCODMn-90 |
| Measuring Principle | Acidic Potassium Permanganate Oxidation with Photometric Endpoint Detection |
| Range | 0–20 mg/L (expandable) |
| Repeatability | ±4% |
| Accuracy | ±4% |
| LOD | 0.1 mg/L |
| Resolution | 0.01 mg/L |
| Analysis Time per Cycle | 40–60 min |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Xact 920 |
| Price Range | USD 70,000 – 125,000 (FOB) |
| Instrument Type | Online Analyzer |
| Detection Principle | X-ray Fluorescence (XRF) with Real-Time Regeneration (RTR) |
| Target Elements | Up to 24 heavy metals simultaneously |
| Measurement Interval | Configurable at 15, 30, 60, 120, 180, or 240 minutes per cycle |
| Detection Range | Sub-ppb to low-ppt levels |
| Sample Matrix | Aqueous solutions with variable total dissolved solids (TDS) |
| Origin | Hebei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XHZ2006 |
| Pricing | Available Upon Request |
| Measurement Principle | Flow Injection Analysis (FIA) |
| Measurement Range | 0–100 mg/L KMnO₄ |
| Accuracy | ±5% FS |
| Precision | ±5% FS |
| Detection Limit | 0.1 mg/L |
| Resolution | 0.1 mg/L |
| Minimum Cycle Time | 12 min |
| Dimensions | 620 × 1400 × 500 mm |
| Weight | 100 kg |
| Power Supply | 200 V, 50 Hz |
| Power Consumption | 200 W |
| Pump Type | Ceramic High-Pressure Injection Pump |
| Sample Handling | Direct injection, no pretreatment or cleaning required |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | SERES 2000 NH₃-N |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Salicylate Spectrophotometry) |
| Measurement Range | 0–1 mg/L, 0–10 mg/L, 0–100 mg/L (extendable to 500 mg/L) |
| Accuracy | ±3% FS |
| Detection Limit | 0.005 mg/L |
| Cycle Time | 15 minutes per measurement |
| Batch Capacity | 3 samples simultaneously |
| Origin | Hebei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SERES 2000 CODMn |
| Measurement Principle | Potassium Permanganate Oxidation with ORP/Photometric Endpoint Detection |
| Range | 0–10 mg/L and 0–20 mg/L (expandable to 100 mg/L) |
| Repeatability | ≤3% RSD |
| Accuracy | ±3% of reading |
| LOD | 0.1 mg/L |
| Resolution | ≤0.01 mg/L |
| Analysis Time per Sample | 25 minutes |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | XHFP-90P |
| Instrument Type | Online Monitoring System |
| Temperature Range | -5 to 60 °C (non-freezing) |
| pH Range | 0–14 pH |
| Dissolved Oxygen Range | 0–50 mg/L |
| Conductivity Range | 0–500 mS/cm |
| Turbidity Range | 0–500 NTU (extendable to 0–4000 NTU) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XHTN-90 |
| Measurement Parameter | Total Nitrogen |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (Alkaline Potassium Persulfate Digestion + UV Absorption at 220 nm) |
| Measurement Range | 0–50 mg/L (expandable) |
| Accuracy | ±3.0% FS |
| Detection Limit | 0.1 mg/L |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Groundwater Automatic Monitoring System |
| Price Range | USD 42,000 – 70,000 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SERES2000 |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Hexavalent Chromium (Cr(VI)) |
| Measurement Principle | 1,5-Diphenylcarbazide (DPC) Spectrophotometric Method |
| Wavelength | 540 nm |
| Compliance | HJ 609–2011 |
| Valve System | Imported Multi-Position Rotary Valve |
| Detection System | High-Precision Infrared Photometric Reagent Metering |
| Optical Unit | High-Accuracy Spectrophotometer |
| Sample Introduction | Non-Contact Peristaltic Sampling |
| Tubing Material | Modified PTFE |
| Temperature Control | Precision Thermostatic Regulation |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | XHUV-90A |
| Measurement Wavelength | 254 nm (UV) + Visible Reference |
| Compensation | Temperature & Visible-Light Baseline Correction |
| Measurement Ranges | 0–200 m⁻¹ |
| Repeatability | ±1.5% FS |
| Zero Drift | ±1.5% FS |
| Span Drift | ±1.5% FS |
| Linearity | ±4% FS |
| Power Supply | AC 220 V, 50 Hz |
| Output Interfaces | RS232/RS485 digital communication |
| Display | Touchscreen LCD with Chinese UI |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SERES 2000 Cu |
| Instrument Type | Online Analyzer |
| Detection Principle | Bathocuproine-based Photometric Method with High-Temperature Acid Oxidation |
| Target Analyte | Total Copper (Cu) |
| Analysis Time | ≤ 40 min per cycle |
| Accuracy/Precision | ±10% RSD |
| Detection Resolution | 0.01 mg/L |
| Optical Wavelength | 480 nm |
| Sample Introduction | Non-contact Peristaltic Sampling with Modified PTFE Tubing |
| Digestion System | High-temperature, high-pressure Acid Oxidation Module |
| Reagent Delivery | High-precision Infrared Photoelectric Metering System |
| Valve System | Imported Multi-port Rotary Valve |
| Temperature Control | PID-regulated Heating Block with ±0.5 °C Stability |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XH-WQST |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | COD, BOD, TOC, UV₂₅₄, Color, Turbidity, Nitrate-N, Nitrite-N |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SERES 2000 Pb |
| Instrument Type | Online Analyzer |
| Detection Principle | Spectrophotometry (High-Temperature Oxidation + Porphyrin-Based Colorimetry) |
| Target Analyte | Lead (Pb) |
| Analysis Time | ≤30 min per cycle |
| Accuracy/Precision | ±10% of full scale |
| Resolution | 0.01 mg/L |
| Detection Range | 0.05–5.00 mg/L (typical, configurable per regulatory requirements) |
| Sample Inlet | Non-contact peristaltic pumping with modified PTFE tubing |
| Digestion System | High-temperature, high-pressure oxidation module (up to 120 °C, 0.3 MPa) |
| Photometric Unit | High-stability dual-beam spectrophotometer with 520 nm LED source and thermoelectrically stabilized detector |
| Reagent Delivery | Infrared optical reagent metering system with <±0.5% volumetric repeatability |
| Valve System | Imported multi-position selection valve (ceramic rotor, chemically inert) |
| Temperature Control | PID-regulated thermal management (±0.3 °C stability over operating range) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Geopump I / Geopump II |
| Instrument Category | Manual Water Sampler |
| Instrument Type | Portable Groundwater Sampler |
| Maximum Sampling Depth | ≤ 8.8 m below ground surface |
| Flow Rate Range (by Tubing Size) | 15# tubing: 11–1100 mL/min |
| 24# tubing | 18–1800 mL/min |
| 35# tubing | 26–2600 mL/min |
| 36# tubing | 34–3400 mL/min |
| Power Supply | AC 220 V / DC 12 V |
| Dual-Station Configuration | Geopump II only |
| Direction Control | Forward/Reverse (for backflushing) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Instrument Type | Online Water Quality Analyzer |
| Detection Parameters | Total Phosphorus (TP), Orthophosphate (PO₄³⁻), Total Nitrogen (TN), Ammonia-N (NH₃-N), Nitrate-N (NO₃⁻), Nitrite-N (NO₂⁻), Hexavalent Chromium (Cr⁶⁺) |
| Detection Methodology | Sequential Injection Analysis (SIA) with Standardized Spectrophotometric and UV-Absorption Protocols |
| Reagent Consumption | 400–600 µL per measurement cycle |
| Standby Power | 0.25 W |
| Operational Duration per Reagent Fill | 180–200 analyses (at 4–6 cycles/day ≈ 40 days) |
| Compliance Basis | Chinese National Standards (e.g., GB 11893-89, GB 11894-89, HJ 636-2012, HJ 535-2009, HJ 537-2009, HJ 546-2015, HJ 547-2015) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | XHAN-91 |
| Price Range | USD 21,000 – 28,000 (FOB) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Nesslerization or Salicylate, compliant with ISO 7150-1 & HJ 1002-2018) |
| Measurement Range | 0.1–80 mg/L NH₃–N (extendable via dilution module) |
| Detection Limit | 0.005 mg/L NH₃–N |
| Cycle Time | 40–60 minutes per analysis |
| Temperature Control Accuracy | ±0.1 °C |
| Reagent Consumption | <100 µL per measurement |
| Flow System | Zero-dead-volume sequential injection manifold |
| Calibration | Auto-range switching without standard solution replacement |
| Data Integrity | Built-in audit trail, event logging, and power-loss recovery |
| Brand | SAIL HERO (Xianhe Environmental Protection) |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | 300 PSI / 500 PSI |
| Instrument Type | Manual Water Sampler |
| Power Input Options | DC/AC |
| Max. Operating Depth | 210 m (300 PSI) / 305 m (500 PSI) |
| Bladder Material | Virgin PTFE (Resin-Grade) |
| Housing Material | 316 Stainless Steel |
| Inlet Filter | Integrated Stainless Steel Sieve |
| Controller Features | Microprocessor-Based Timing, Over-Pressure Protection, Water-Level Drawdown Compatibility with DIP-Tape Sensors |
| Drop-Tube Compatible | Yes |
| Regulatory Compliance | Designed for ASTM D6771, EPA Method 502.2 & 8260-compliant VOC sampling workflows |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | SERES 2000 Zn |
| Instrument Type | Online Analyzer |
| Detection Principle | Photometric Method (Porphyrin-based Colorimetry) |
| Target Analyte | Zinc (Zn) |
| Analysis Time | ≤40 min |
| Accuracy/Precision | ±10% |
| Resolution | 0.01 mg/L |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | Redi-Flo2 |
| Instrument Type | Manual Water Sampler |
| Max Operating Depth | 85 m |
| Flow Range | 100 mL/min to 30 L/min |
| Pump Diameter | 4.6 cm |
| Well Compatibility | ≥5 cm diameter monitoring wells |
| Material | Chemically inert (FDA-compliant elastomers and 316 stainless steel components) |
| Configuration Options | Dedicated-well or portable setup |
| Origin | Hebei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XHZ2004 |
| Price | Available Upon Request |
| Measurement Principle | Flow Injection Analysis (FIA) with High-Temperature Acid Digestion |
| Range | 0.05–50 mg/L TP |
| Detection Limit | 0.05 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy & Precision | ±10% of Full Scale (FS) |
| Minimum Cycle Time | 12 min |
| Digestion Conditions | 130 °C, 0.7 MPa |
| Dimensions (W×H×D) | 620 × 1500 × 500 mm |
| Weight | 110 kg |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 250 W |
| Sample Handling | Direct injection—no pretreatment or post-run cleaning required |
| Maintenance Interval | >6 months under continuous operation |