- All
- Favorite
- Popular
- Most rated
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | XHAQSP-708 |
| Sensor Principle | Electrochemical (O₂ & toxic gases), optional catalytic bead or infrared for combustibles |
| Detection Method | Diffusion and flow-through sampling |
| Display | 2.0-inch industrial-grade color LCD (-40°C to +70°C operating range) |
| Output Options | 4–20 mA (3-wire), RS-485 Modbus RTU, 4G LTE cellular telemetry |
| Relay Output | Built-in SPDT alarm relay (rated 250 VAC/30 VDC, 5 A) |
| Explosion Protection | Ex db IIC T6 Gb |
| Enclosure Rating | IP66 |
| Power Supply | 12–24 VDC |
| Response Time (T90) | <30 s (typical for electrochemical sensors) |
| Detection Range | Configurable per gas (e.g., 0–30 ppm CO, 0–25% vol O₂, 0–100% LEL CH₄) |
| Lower Detection Limit | Sub-ppm for select toxic gases |
| Compliance | GB 12358-2006, GB 3836.1–2010, GB 3836.4–2010, CE (per ATEX directive 2014/34/EU for non-certified use in EU zones), RoHS |
| Brand | SAIL HERO |
|---|---|
| Origin | USA |
| Manufacturer | Sunset Laboratory, Inc. |
| Model | Model 5L |
| Instrument Type | Aerosol OC/EC Thermal-Optical Analyzer |
| Compliance | NIOSH Method 5040, IMPROVE_A, EUSAAR2, EPA STN |
| Detection Principle | Thermal-Optical Transmittance (TOT) with Flame Ionization Detection (FID) |
| Calibration Standards | NIST-traceable sucrose solution and certified gas standards |
| Data Output | OC (µgC/cm²), EC (µgC/cm²), CC (µgC/cm²) |
| Software | Sunset OC/EC Data Analysis Suite with audit trail, manual peak integration, and dual-mode (transmittance/reflection) charring correction |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHCAL3000 |
| Pricing | Available upon request |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGMS4000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Gases & Measurement Ranges | CO₂ (0–5000 ppm), CH₄ (0–100 ppm), N₂O (0–50 ppm) |
| Compliance | GB/T 38997–2020, HJ 1013–2018, ISO 14064-1, ASTM D6522 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHPM2001 |
| Measurement Principle | Beta-ray Absorption (β-ray) |
| Measured Parameters | TSP, PM10, PM2.5, PM1 |
| Sampling Flow Rate | 16.7 L/min |
| Display | 7-inch High-Brightness TFT Touchscreen with Windows-based GUI |
| Calibration Method | Standardized Calibration Foil |
| Compliance | Certified by China Environmental Monitoring Station (CEMS) for PM10 Portability |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHAQSN-812 |
| Pricing | Available upon Request |
| Measured Pollutants | PM₂.₅, PM₁₀, SO₂, NO₂, NO, CO, O₃ |
| Optional Parameters | TSP, TVOC, Noise, Meteorological Five Parameters (Wind Speed, Wind Direction, Temperature, Relative Humidity, Atmospheric Pressure), Onboard Imaging |
| Brand | SAIL HERO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | XHVOC6000 |
| Detection Principle | Gas Chromatography-Mass Spectrometry (GC-MS) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-component VOC Monitoring System |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | XHAQSP-709B |
| Instrument Type | Online Monitoring System |
| Detection Principle | Multi-sensor Array (Electrochemical, Metal Oxide Semiconductor – MOS, Photoionization Detector – PID) |
| Target Analytes | NH₃, H₂S, Trimethylamine, Methanethiol, Dimethyl Sulfide, Dimethyl Disulfide, Carbon Disulfide, Styrene, Odor Intensity (OUₑ) |
| Optional | TVOC, Cl₂, HCl |
| Compliance | GB 14554–1993 “Emission Standard of Malodorous Pollutants” |
| Data Storage | ≥3 years |
| Operating Temperature Range for Sensors | −20 °C to +50 °C |
| Sampling Method | Constant-flow sampling |
| Humidity Mitigation | Deep condensation dew point control + multi-stage particulate filtration |
| Calibration | Automated zero/span calibration with standard gas |
| Connectivity | Dual-mode (wired Ethernet + wireless LTE/4G) |
| Display | Integrated capacitive touchscreen interface |
| Algorithm Engine | Cross-interference compensation model + neural network-based odor intensity quantification |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XHS2100B |
| Measured Pollutant | H₂S |
| Detection Principle | Catalytic Thermal Conversion + UV Fluorescence (SO₂) |
| Conversion Efficiency | >96% |
| Zero/Span Calibration | Manual or Remote Automated |
| Data Storage | Internal Dynamic Memory ≥1 Year (1-Minute Averages) |
| Environmental Compensation | Automatic Temperature & Pressure Correction |
| Interference Mitigation | Integrated Hydrocarbon Scrubber (PAH Removal) |
| Communication Interfaces | RS232, RS485, 0–5 V Analog Output, 4–20 mA Current Loop (Optional) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHAQSN-822 |
| Pricing | Available upon Request |
| Measured Pollutants | PM2.5, PM10, TSP, CO, O₃, SO₂, NO₂, NO, TVOC |
| Optional Modules | Meteorological Sensors (Temperature, Relative Humidity, Atmospheric Pressure, Wind Speed, Wind Direction), Noise Monitoring, Video Surveillance, Negative Air Ions |
| Sensor Technologies | Laser Scattering (PM), Quad-Electrode Electrochemical (Gases), Photoionization Detection (TVOC) |
| Certifications | CAPI Environmental Product Certification (China) |
| Brand | SAIL HERO |
|---|---|
| Model | XHN2100B |
| Measurement Principle | Chemiluminescence Detection (CLD) with NO–O₃ Reaction |
| Target Analyte | NH₃ (derived via TNₓ–NOₓ differential) |
| Compliance | Designed for continuous ambient air quality monitoring per China’s HJ 654-2013 and compatible with EPA Method 7010 / ISO 11088:2021 frameworks |
| Output Options | RS232, RS485, 0–5 V analog, 4–20 mA current loop (optional) |
| Environmental Compensation | Integrated temperature & pressure sensors with real-time correction |
| Calibration | Manual or remote zero/span calibration capability |
| Display & Interface | Touchscreen GUI with multilingual support (default Chinese, English firmware-ready) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Operating Temperature | 0–40 °C |
| Enclosure Rating | IP54 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHPM2000E |
| Measurement Method | Beta-ray Absorption (β-ray) with Dynamic Heating System |
| Measured Parameter | PM₁₀ |
| Measurement Range | 0–0.1, 0.2, 1, 2, 5, or 10 mg/m³ (user-selectable full-scale) |
| Sampling Interval | 30 min to 1 h (configurable) |
| Sample Flow Rate | 16.7 L/min ±2.5% |
| Limit of Detection (24-h avg) | 1 µg/m³ |
| Compliance | EPA EQPM-0805-154 (equivalent), HJ 653–2013, HJ 93–2013, HJ 978–2018 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XHZ3000 |
| Zero Air Purity | SO₂ ≤ 0.1 nmol/mol |
| Output Pressure Range | 0.06–0.42 MPa |
| Dew Point | < −20 °C |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | XHCEMS-8000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measured Gases & Ranges | CO₂ (standard), with optional expansion to CH₄ and N₂O |
| Application Field | Environmental Compliance Monitoring |
| Regulatory Context | Designed for continuous compliance reporting per national emission standards (e.g., China’s HJ 75–2017, HJ 76–2017) and compatible with international CEMS framework requirements (e.g., EN 14181, US EPA PS-11/PS-15) |
| Brand | SAIL HERO |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | BAM1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10, PM2.5 |
| EPA Certification | EQPM-0798-122 (PM10), EQPM-0308-170 (PM2.5) |
| Calibration Standard | FRM-certified calibration membrane |
| Data Storage Capacity | 182 days |
| Remote Operation Duration | Up to 60 days |
| Humidity Control | Integrated precision heater for RH conditioning |
| Communication Interface | RS-232 serial port |
| Meteorological Sensor Support | Up to 6 channels |
| Automatic Span Check Frequency | Hourly |
| Filter Exchange Interval | Hourly |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | XHAQSP-709A |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Hybrid Sensor Array (Electrochemical, Metal Oxide Semiconductor – MOS, and Photoionization Detector – PID) |
| Target Analytes | NH₃, H₂S, Trimethylamine, Methanethiol, Dimethyl Sulfide, Dimethyl Disulfide, Carbon Disulfide, Styrene, Odor Intensity (OUₘ), Optional: TVOC, Cl₂, HCl |
| Compliance | GB 14554–1993 “Emission Standard of Odorous Pollutants” |
| Data Storage | ≥3 years (local SD + cloud backup) |
| Operating Temperature Range | –20 °C to +50 °C (sensor-controlled) |
| Sampling Method | Constant-flow sampling with integrated thermoelectric cooling condenser and multi-stage particulate filtration |
| Calibration | Automated zero/span calibration using standard gas cylinders |
| Brand | SAIL HERO (Xianhe Environmental Protection) |
|---|---|
| Origin | USA |
| Manufacturer | Sunset Laboratory, Inc. |
| Instrument Type | Aerosol Carbon Analyzer |
| Compliance | NIOSH Method 5040, IMPROVE, STN protocols |
| Calibration Standards | NIST-traceable sucrose solution and CH₄/He (5% CH₄ in He) calibration gas |
| Detection Principle | Thermal-Optical Transmittance (TOT) with real-time laser transmittance monitoring |
| Operating Mode | Semi-continuous automated cycle (sampling → analysis → sampling → analysis...) |
| Data Output | Continuous real-time OC/EC mass concentrations (µg/m³), split point identification, charring correction |
| Gas Control | Electronically regulated proportional pressure control system with computer-managed flow paths |
| Laser System | High-stability 635 nm diode laser with precision optical alignment and thermal drift compensation |
| Heater Assembly | Long-life quartz tube furnace with adaptive power regulation and ±0.5°C temperature stability |
| Sample Substrate | Pre-baked quartz fiber filter tape (25 mm diameter) |
| Flow Control Accuracy | ±1.5% of setpoint across 0.1–2.0 L/min range |
| Environmental Compensation | Automatic T&P correction using integrated temperature/pressure sensors |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | XHCYQ2000 |
| Flow Rate | 16.67 L/min (±0.3 L/min) |
| Flow RSD | ≤1.5% |
| Flow Accuracy | ≤1.5% |
| Standardized Volume Error | ±3% |
| Clock Drift (6h, powered) | ±10 s |
| Clock Drift (6h, after 5 power interruptions) | ±2 min |
| Barometric Pressure Accuracy | ≤1 kPa |
| Temperature Accuracy | ±2 ℃ |
| Reference Method Correlation | Slope = 1 ± 0.1, Intercept = 0 ± 0.5 µg/m³, r ≥ 0.97 |
| MTBF | ≥800 h |
| Dimensions (H×W×D) | 46 cm × 66 cm × 35 cm (excl. pump enclosure) |
| Weight | 25 kg |
| Origin | Hebei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | XHAQSN-804 |
| Pricing | Upon Request |
| Measurement Principle | Hybrid Electrochemical & Optical Sensing |
| Measured Parameters | PM₂.₅, PM₁₀, Temperature, Relative Humidity |
| Power Supply | Flexible (DC 12 V / Solar Optional) |
| Communication | LTE-M/NB-IoT + Secure TLS 1.2 Encrypted Uplink |
| Data Resolution | 1–5 Minute Intervals |
| Compliance | CE-marked for Environmental Use |
| Enclosure Rating | IP65 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHAQMS3000 |
| Pollutants Measured | SO₂, NOₓ (NO, NO₂), CO, O₃, TSP, PM₁₀, PM₂.₅, PM₁ |
| Operating Temperature Range | −40 °C to +45 °C |
| Operating Humidity Range | 0–100 % RH |
| Enclosure Dimensions | ≤1800 × 850 × 950 mm |
| Enclosure IP Rating | IP65 |
| Data Acquisition & Transmission | Integrated DAQ with wired (RS485/Ethernet) and wireless (4G/LTE) support |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHS2000B |
| Measured Pollutant | SO₂ |
| Detection Principle | UV Fluorescence (UVF) |
| Interference Mitigation | Integrated Hydrocarbon Scrubber for PAH Removal |
| Compliance | Certified by China Environmental Monitoring Instrument Quality Supervision & Inspection Center |
| Data Storage | >1 year of minute-averaged data (internal dynamic memory) |
| Environmental Compensation | Automatic temperature and pressure compensation |
| Communication Interfaces | RS232, RS485 (standard) |
| User Interface | Chinese-language menu with self-diagnostic and alarm functions |
| Power Recovery | Auto-restart on power restoration |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHAQSP-709D |
| Instrument Type | Portable |
| Detection Principles | Electrochemical (EC), Metal Oxide Semiconductor (MOS), Photoionization Detection (PID) |
| Target Analytes | NH₃, H₂S, Trimethylamine, Methanethiol, Dimethyl Sulfide, Dimethyl Disulfide, Carbon Disulfide, Styrene, Odor Intensity (OUₑ), Optional: TVOC, Cl₂, HCl |
| Compliance | GB 14554–1993 “Emission Standard of Odorous Pollutants” |
| Data Connectivity | 4G + BeiDou/GPS Dual-Mode Positioning |
| Power Supply | Rechargeable Lithium Battery + AC Adapter |
| Operating Temperature Range | –20 °C to +50 °C with Sensor Thermostatic Control |
| User Interface | Industrial-Grade Capacitive Touchscreen |
| Calibration | Automated Zero Calibration |
| Software Integration | Cloud Platform & Mobile APP (iOS/Android) |
| Data Processing | Cross-Interference Compensation Algorithm, Artificial Neural Network (ANN) Modeling, Principal Component Analysis (PCA) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | CCLJP-100 |
| Pricing | Upon Request |
| Measurement Principle | Optical Light Scattering (Lorenz-Mie Theory) |
| Sampling Flow Rate | 4.8 L/min |
| Particle Size Range | 0.18–100 µm |
| Particle Number Concentration Range | 0–20,000 particles/cm³ |
| Size Channels | 64 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | CCLJP-100B |
| Pricing | Upon Request |
| Measurement Principle | Optical Light Scattering |
| Particle Size Range | 0.3–20 µm |
| Number of Size Channels | 12 |
Show next