- All
- Favorite
- Popular
- Most rated
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | VERSS Series |
| Pricing | Available upon Request |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | XHAQSP-708 |
| Sensor Principle | Electrochemical (O₂ & toxic gases), optional catalytic bead or infrared for combustibles |
| Detection Method | Diffusion and flow-through sampling |
| Display | 2.0-inch industrial-grade color LCD (-40°C to +70°C operating range) |
| Output Options | 4–20 mA (3-wire), RS-485 Modbus RTU, 4G LTE cellular telemetry |
| Relay Output | Built-in SPDT alarm relay (rated 250 VAC/30 VDC, 5 A) |
| Explosion Protection | Ex db IIC T6 Gb |
| Enclosure Rating | IP66 |
| Power Supply | 12–24 VDC |
| Response Time (T90) | <30 s (typical for electrochemical sensors) |
| Detection Range | Configurable per gas (e.g., 0–30 ppm CO, 0–25% vol O₂, 0–100% LEL CH₄) |
| Lower Detection Limit | Sub-ppm for select toxic gases |
| Compliance | GB 12358-2006, GB 3836.1–2010, GB 3836.4–2010, CE (per ATEX directive 2014/34/EU for non-certified use in EU zones), RoHS |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SERES 2000 As |
| Instrument Type | Online Water Quality Analyzer |
| Target Analyte | Total Arsenic (As) |
| Detection Principle | High-Temperature Oxidation Coupled with Ternary Complexation Spectrophotometry |
| Wavelength | 545 nm |
| Reagent Delivery | Infrared Photoelectric Precision Metering System |
| Sample Introduction | Non-Contact Peristaltic Sampling |
| Tubing Material | Modified PTFE |
| Digestion System | High-Pressure/High-Temperature Acid Oxidation |
| Temperature Control Accuracy | ±0.3 °C |
| Compliance | Designed for ISO 10566, EPA Method 200.8 (adapted), and GB/T 32217–2015 |
| Brand | SAIL HERO |
|---|---|
| Origin | USA |
| Manufacturer | Sunset Laboratory, Inc. |
| Model | Model 5L |
| Instrument Type | Aerosol OC/EC Thermal-Optical Analyzer |
| Compliance | NIOSH Method 5040, IMPROVE_A, EUSAAR2, EPA STN |
| Detection Principle | Thermal-Optical Transmittance (TOT) with Flame Ionization Detection (FID) |
| Calibration Standards | NIST-traceable sucrose solution and certified gas standards |
| Data Output | OC (µgC/cm²), EC (µgC/cm²), CC (µgC/cm²) |
| Software | Sunset OC/EC Data Analysis Suite with audit trail, manual peak integration, and dual-mode (transmittance/reflection) charring correction |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | XHAN-90B |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ammonia Gas-Sensing Electrode Method |
| Measurement Range | 0–1000 mg/L NH₃–N (adjustable in multiple sub-ranges) |
| Detection Limit | 0.05 mg/L NH₃–N |
| Response Time | < 3 minutes (t₉₀) |
| Sample Requirements | Particulate concentration ≤ 10 mg/L, particle size < 0.1 mm (filtration not required) |
| Calibration | Automated two-point calibration (zero/span) |
| Data Storage | ≥ 90 days of high-resolution time-stamped records (1-min to 1-h intervals configurable) |
| Communication Interfaces | 4–20 mA analog output, RS485 serial interface, MODBUS RTU protocol support |
| Remote Access | TCP/IP-enabled for web-based monitoring and configuration |
| Maintenance Features | Automatic electrode cleaning cycle, reagent level monitoring, fault diagnostics with event logging |
| Compliance | Designed to meet ISO 15681-2:2022 (Water quality — Determination of phosphorus and nitrogen compounds — Part 2: Ammonium — Electrode method), supports GLP/GMP data integrity requirements including audit trail and user access control |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHCAL3000 |
| Pricing | Available upon request |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHAQSN-901 |
| Pricing | Available upon Request |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SERES 2000 Mn |
| Instrument Type | Online Analyzer |
| Detection Principle | Spectrophotometry (Formaldehyde Oxime Method with High-Temperature Oxidation) |
| Target Analyte | Manganese (Total Mn) |
| Analysis Cycle Time | ≤40 min |
| Accuracy/Precision | ±10% of Full Scale |
| Resolution | 0.01 mg/L |
| Wavelength | 470 nm |
| Compliance | Designed for continuous unattended operation in industrial and municipal wastewater monitoring environments |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGMS4000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Gases & Measurement Ranges | CO₂ (0–5000 ppm), CH₄ (0–100 ppm), N₂O (0–50 ppm) |
| Compliance | GB/T 38997–2020, HJ 1013–2018, ISO 14064-1, ASTM D6522 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | SERES 2000 TP |
| Measurement Parameter | Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | UV-Catalyzed Alkaline Persulfate Oxidation Coupled with Molybdenum Blue Spectrophotometry |
| Measurement Range | 0–0.5 / 0–5 / 0–10 / 0–50 mg/L P (selectable ranges) |
| Accuracy | ±3% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | ≤0.01 mg/L |
| Compliance Standard | HJ/T 103–2003 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XHCODMn-90 |
| Measuring Principle | Acidic Potassium Permanganate Oxidation with Photometric Endpoint Detection |
| Range | 0–20 mg/L (expandable) |
| Repeatability | ±4% |
| Accuracy | ±4% |
| LOD | 0.1 mg/L |
| Resolution | 0.01 mg/L |
| Analysis Time per Cycle | 40–60 min |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Xact 920 |
| Price Range | USD 70,000 – 125,000 (FOB) |
| Instrument Type | Online Analyzer |
| Detection Principle | X-ray Fluorescence (XRF) with Real-Time Regeneration (RTR) |
| Target Elements | Up to 24 heavy metals simultaneously |
| Measurement Interval | Configurable at 15, 30, 60, 120, 180, or 240 minutes per cycle |
| Detection Range | Sub-ppb to low-ppt levels |
| Sample Matrix | Aqueous solutions with variable total dissolved solids (TDS) |
| Origin | Hebei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XHZ2006 |
| Pricing | Available Upon Request |
| Measurement Principle | Flow Injection Analysis (FIA) |
| Measurement Range | 0–100 mg/L KMnO₄ |
| Accuracy | ±5% FS |
| Precision | ±5% FS |
| Detection Limit | 0.1 mg/L |
| Resolution | 0.1 mg/L |
| Minimum Cycle Time | 12 min |
| Dimensions | 620 × 1400 × 500 mm |
| Weight | 100 kg |
| Power Supply | 200 V, 50 Hz |
| Power Consumption | 200 W |
| Pump Type | Ceramic High-Pressure Injection Pump |
| Sample Handling | Direct injection, no pretreatment or cleaning required |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | SERES 2000 NH₃-N |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Salicylate Spectrophotometry) |
| Measurement Range | 0–1 mg/L, 0–10 mg/L, 0–100 mg/L (extendable to 500 mg/L) |
| Accuracy | ±3% FS |
| Detection Limit | 0.005 mg/L |
| Cycle Time | 15 minutes per measurement |
| Batch Capacity | 3 samples simultaneously |
| Origin | Hebei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SERES 2000 CODMn |
| Measurement Principle | Potassium Permanganate Oxidation with ORP/Photometric Endpoint Detection |
| Range | 0–10 mg/L and 0–20 mg/L (expandable to 100 mg/L) |
| Repeatability | ≤3% RSD |
| Accuracy | ±3% of reading |
| LOD | 0.1 mg/L |
| Resolution | ≤0.01 mg/L |
| Analysis Time per Sample | 25 minutes |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHPM2001 |
| Measurement Principle | Beta-ray Absorption (β-ray) |
| Measured Parameters | TSP, PM10, PM2.5, PM1 |
| Sampling Flow Rate | 16.7 L/min |
| Display | 7-inch High-Brightness TFT Touchscreen with Windows-based GUI |
| Calibration Method | Standardized Calibration Foil |
| Compliance | Certified by China Environmental Monitoring Station (CEMS) for PM10 Portability |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | XHFP-90P |
| Instrument Type | Online Monitoring System |
| Temperature Range | -5 to 60 °C (non-freezing) |
| pH Range | 0–14 pH |
| Dissolved Oxygen Range | 0–50 mg/L |
| Conductivity Range | 0–500 mS/cm |
| Turbidity Range | 0–500 NTU (extendable to 0–4000 NTU) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XHTN-90 |
| Measurement Parameter | Total Nitrogen |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (Alkaline Potassium Persulfate Digestion + UV Absorption at 220 nm) |
| Measurement Range | 0–50 mg/L (expandable) |
| Accuracy | ±3.0% FS |
| Detection Limit | 0.1 mg/L |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHAQSN-812 |
| Pricing | Available upon Request |
| Measured Pollutants | PM₂.₅, PM₁₀, SO₂, NO₂, NO, CO, O₃ |
| Optional Parameters | TSP, TVOC, Noise, Meteorological Five Parameters (Wind Speed, Wind Direction, Temperature, Relative Humidity, Atmospheric Pressure), Onboard Imaging |
| Brand | SAIL HERO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | XHVOC6000 |
| Detection Principle | Gas Chromatography-Mass Spectrometry (GC-MS) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-component VOC Monitoring System |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XHBX6001 |
| Detection Target | Gaseous CO |
| Response Time | ≤100 s |
| Measurement Principle | Electrochemical Sensing |
| Environmental Compensation | Integrated Temperature & Atmospheric Pressure Sensors |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | XHAQSP-709B |
| Instrument Type | Online Monitoring System |
| Detection Principle | Multi-sensor Array (Electrochemical, Metal Oxide Semiconductor – MOS, Photoionization Detector – PID) |
| Target Analytes | NH₃, H₂S, Trimethylamine, Methanethiol, Dimethyl Sulfide, Dimethyl Disulfide, Carbon Disulfide, Styrene, Odor Intensity (OUₑ) |
| Optional | TVOC, Cl₂, HCl |
| Compliance | GB 14554–1993 “Emission Standard of Malodorous Pollutants” |
| Data Storage | ≥3 years |
| Operating Temperature Range for Sensors | −20 °C to +50 °C |
| Sampling Method | Constant-flow sampling |
| Humidity Mitigation | Deep condensation dew point control + multi-stage particulate filtration |
| Calibration | Automated zero/span calibration with standard gas |
| Connectivity | Dual-mode (wired Ethernet + wireless LTE/4G) |
| Display | Integrated capacitive touchscreen interface |
| Algorithm Engine | Cross-interference compensation model + neural network-based odor intensity quantification |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XHS2100B |
| Measured Pollutant | H₂S |
| Detection Principle | Catalytic Thermal Conversion + UV Fluorescence (SO₂) |
| Conversion Efficiency | >96% |
| Zero/Span Calibration | Manual or Remote Automated |
| Data Storage | Internal Dynamic Memory ≥1 Year (1-Minute Averages) |
| Environmental Compensation | Automatic Temperature & Pressure Correction |
| Interference Mitigation | Integrated Hydrocarbon Scrubber (PAH Removal) |
| Communication Interfaces | RS232, RS485, 0–5 V Analog Output, 4–20 mA Current Loop (Optional) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Groundwater Automatic Monitoring System |
| Price Range | USD 42,000 – 70,000 |
Show next