Empowering Scientific Discovery

Hebei Sunriver Environmental Protection Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSAIL HERO
OriginHebei, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelCCLJP-100A
PricingAvailable Upon Request
Measurement PrincipleOptical Light Scattering (90° Detection)
Sampling Flow Rate1 L/min
Particle Size Range0.18–20 µm
Particle Counting Range0–20,000 particles/cm³
Number of Size Channels64
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSAIL HERO
OriginHebei, China
Manufacturer TypeDirect Manufacturer
Instrument TypeOnline Analyzer
Measurement PrinciplePotassium Dichromate Oxidation–Spectrophotometric Method
Measurement Range0–3500 mg/L COD<sub>Cr</sub> (expandable)
Repeatability±3% RSD
Limit of Detection5 mg/L COD<sub>Cr</sub>
Analysis Cycle Time60–360 min per measurement
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSAIL HERO
OriginHebei, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelXHPM2000E
Measurement PrincipleBeta-ray attenuation with dynamic heating system
Measured ParameterPM₂.₅ mass concentration
Measurement Range0–0.1, 0.2, 1, 2, 5, or 10 mg/m³ (user-selectable full-scale ranges)
Measurement Cycle30 min to 60 min (configurable)
Sampling Flow Rate16.7 L/min ±2.5%
Limit of Detection (24-hr avg)5 µg/m³
ComplianceCertified per Chinese EPA requirements for radioactive source management, HJ 653–2013, HJ 93–2013, and GB/T 34672–2017
Regulatory ApprovalsCEPAA Environmental Product Certification, CNEMC Calibration & Performance Verification Report, CIPAC Technical Appraisal Certificate for PM₂.₅ Separation Inlet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSAIL HERO
OriginHebei, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelXHAQSP-709E
Instrument TypeOnline
Detection PrincipleMulti-sensor Array (Electrochemical, Metal Oxide Semiconductor, Photoionization Detector PID)
Sampling MethodNegative-pressure Vacuum Sampling
Sample ContainerPolyester Gas Sampling Bags (Low Adsorption, Low Permeability, Low VOC Background)
Deployment FlexibilityAmbient Air or Integrated Monitor Inlet Sampling
Bag Capacity & QuantityConfigurable (Standard Options: 1–6 bags × 0.5–3 L each)
Compliance ContextDesigned to support GB/T 14675–2023, GB/T 14678–1993, HJ 905–2017, and ISO 16000-6 for odor sample integrity and traceability