Microplate Reader
Filter
Showing 61–90 of 100 results
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SpectraMax iD3 |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting | SoftMax Pro Software-Based |
| Detector Type | PMT and Photodiode |
| Wavelength Range | Absorbance 230–1000 nm |
| Absorbance Range | 230–1000 nm |
| Absorbance Linearity | 0–2.0 OD |
| Absorbance Speed | 96-well plate in 25 sec |
| Accuracy | < ±0.010 OD |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Model | SpectraMax iD5 |
| Detection Modes | Absorbance, Fluorescence (including TRF, FP), Luminescence (top/bottom), TR-FRET, HTRF, BRET, Dual-Luciferase (with injectors) |
| Wavelength Range | 230–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±0.010 OD or ±1.0% (0–3.0 OD) |
| Detector | –5°C Cooled Photomultiplier Tube (PMT) and UV-Enhanced Silicon Photodiode |
| Wavelength Scanning Speed | 30 sec per scan |
| Temperature Control | Ambient to 66°C |
| Shaking Modes | Linear, Orbital, Double-Orbital |
| Plate Formats | 6–384-well, including Western blot membranes |
| Optical System | Hybrid Quad-Grating + Filter-Based Pathway |
| Scan Density | Up to 20 × 20 points per well |
| Software | SoftMax Pro 7 with GxP Compliance (21 CFR Part 11, GLP/GMP audit trail) |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SpectraMax Mini |
| Detection Methods | Fluorescence Intensity, Absorbance, Luminescence |
| Functionality | Multimode |
| Automation Level | Fully Automated Microplate Reader |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting Options | Linear, 4-Parameter Logistic (4PL), 5-Parameter Logistic (5PL) |
| Detector | Thermoelectrically Cooled (–5°C) Photomultiplier Tube (PMT) and Photodiode |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±2 nm |
| Wavelength Switching Speed | <1 second per wavelength |
| Absorbance Accuracy | <±0.003 OD ±1.0% (0–3 OD) |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 318C+ |
| Price Range | USD 4,200–7,000 (FOB) |
| Functionality | Multimode |
| Automation Level | Fully Automated |
| Assay Methods | Absorbance, Coefficient Concentration, Standard Concentration, Linear Standard Curve, Single-Threshold (Pass/Fail), Dual-Threshold (Pass/Borderline/Fail), Categorical Classification, Column Subtraction |
| Curve Fitting | Polynomial, Linear, Log-Log, 4-Parameter Logistic (4PL), 5-Parameter Logistic (5PL) |
| Detector Light Source | Imported Halogen Lamp |
| Wavelength Range | 400–800 nm (Standard Filters: 405, 450, 492, 630 nm |
| Absorbance Range | 0.000–4.000 A |
| Linearity Range | 0.000–4.000 A (R² ≥ 0.999) |
| Measurement Speed | 5 s per 96-well plate (single wavelength), 10 s (dual wavelength) |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±0.01 A (0 ≤ A < 1.0) |
| Photometric Precision | ≤0.2% CV (0 ≤ A ≤ 1.5) |
| Stability | ±0.003 A over 30 min |
| Plate Agitation | Three-speed orbital shaking (low/medium/high) |
| Onboard Storage | 200 assay protocols + >1,000 full 96-well plate datasets |
| Display | 7-inch TFT LCD touchscreen (Chinese/English UI) |
| Built-in Thermal Printer | 57 mm width |
| Interface | RS-232 (9-pin D-sub), optional USB-to-serial adapter for modern PC integration |
| Dimensions (L×W×H) | 320 × 286 × 170 mm |
| Power Input | AC 100–240 V, 50/60 Hz |
| Power Consumption | ≤90 VA |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | PLS-24 / PLS-96G / PLS-96 |
| Measurement Range | 0.000–3.000 Abs (PLS-24), 0.000–4.000 Abs (PLS-96G/96) |
| Wavelength Range | 400–1100 nm |
| Optical Channels | 2 (PLS-24), 8 (PLS-96G/96) |
| Read Time (Single Wavelength) | 25 s (PLS-24), 5 s (PLS-96G/96) |
| Wavelength Accuracy | ±2.0 nm |
| Spectral Bandwidth | 8 ± 1.0 nm |
| Absorbance Repeatability (CV) | ≤0.5% |
| Channel Uniformity | ≤0.02 A |
| Stray Light | ≥2.0 A at 510 nm (50.0 g/L NaNO₂) |
| Absorbance Drift | ≤±0.005 A over 20 min (at 492 nm, ~1.000 A) |
| Absorbance Linearity Error | ±0.010 A (0.000–2.000 A), ±0.050 A (2.000–3.500 A) |
| Dimensions | 370 × 245 × 170 mm (PLS-24), 420 × 305 × 170 mm (PLS-96G/96) |
| Weight | 6 kg (PLS-24), 9 kg (PLS-96G/96) |
| Data Storage | 100 assay methods (PLS-24), 200 assay methods + 105 plates (10,000 results) (PLS-96G/96) |
| Interface | RS-232 serial port |
| Display | Color TFT touchscreen (PLS-96G), color TFT with membrane keypad (PLS-24/96) |
| Detection Modes | Absorbance, qualitative, quantitative, enzyme inhibition rate |
| Filter Selection | Manual (PLS-24), automatic (PLS-96G/96) |
| Built-in Thermal Printer | Yes (PLS-24/96), optional external printer support (PLS-96G) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PV820 |
| Pricing | Upon Request |
| Brand | Revvity |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EnVision |
| Functionality | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting Options | Multiple Nonlinear Regression Models (e.g., 4PL, 5PL, Linear, Log-Log) |
| Detector Types | Photodiode & Photomultiplier Tube (PMT) |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | 0–2 OD (±0.5% deviation) |
| Wavelength Switching Time | ≤12 s |
| Absorbance Precision | <0.1% CV at 1 OD |
| Brand | Revvity |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EnVision NEXUS |
| Functionality | Multimode |
| Automation Level | Fully Automated |
| Detector Configuration | Dual-detector architecture enabling parallel high-throughput detection |
| Optical Density Range | 0–4 OD (±50 µOD accuracy) |
| Brand | Revvity |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | VICTOR Kira |
| Detection Modes | Absorbance, Fluorescence, Luminescence |
| Optical System | Quad-grating Monochromator |
| Automation Level | Fully Automated |
| Software Platform | Kira Control Suite |
| Compliance | Designed for GLP/GMP environments, supports 21 CFR Part 11 audit trails |
| Brand | Revvity |
|---|---|
| Origin | Finland |
| Manufacturer | Revvity (Oy, Turku) |
| Product Type | Multimode Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting Options | Linear, Log-Log, 4PL, 5PL, Quadratic, Sigmoidal |
| Detector Types | Silicon Photodiode & High-Sensitivity PMT |
| Wavelength Range | 230–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±0.01 OD (0–2 OD) |
| Wavelength Switching Time | ≤10 s |
| Absorbance Precision | <0.1% CV |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Stat Fax 2100 |
| Pricing | Upon Request |
| Brand | Tecan |
|---|---|
| Origin | Shanghai, China |
| Model | Infinite E Plex (CN) |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Detection Technologies | Quad4™ Monochromator-Based Absorbance, Fluorescence, Luminescence (configurable per application) |
| Wavelength Range (Absorbance) | 230–1000 nm |
| Wavelength Accuracy | ±1.5 nm (260/280 nm verified) |
| Minimum Sample Volume (with NanoQuant Plate EP2045015) | 2 µL per well (16-well parallel measurement) |
| Optical Path | Quartz-fused silica microfluidic light path per sample position, factory-calibrated, no user recalibration required |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-ready software architecture |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Infinite F50 |
| Detection Method | Absorbance |
| Detection Technology | Photometric (LED-based) |
| Measurement Modes | Endpoint, Kinetic, Multi-Label (sequential absorbance reads) |
| Read Channels | 8-channel simultaneous detection |
| Automation Level | Semi-Automatic |
| Light Source | Long-life LED (no warm-up, no alignment required) |
| Software | Magellan v7.x with FDA 21 CFR Part 11 compliance modules |
| Regulatory Compliance | EU IVDR 2017/746 (formerly 98/79/EC IVD Directive), FDA 21 CFR Part 11 audit trail & electronic signature support |
| Vibration Control | Adjustable speed and duration |
| Optical Path Correction | Reference well normalization supported |
| Data Export | CSV, Excel, PDF, XML |
| Interface | USB 2.0, Ethernet |
| Plate Formats | 6–384-well microplates (standard footprint) |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | F50 |
| Function Type | Multimode |
| Automation Level | Semi-Automated |
| Detection Method | Absorbance (Photometric) |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0–4.00 OD |
| Linearity Range | 0.000–2.000 Abs |
| Optical Channels | 8-Channel Simultaneous Detection |
| Wavelength Accuracy | ±2 nm |
| Absorbance Resolution | 0.0001 OD |
| Read Speed | <10 sec per 96-well plate (single wavelength) |
| Light Source | High-Stability LED Array |
| Plate Formats | 6–384-well microplates, cuvettes (optional) |
| Compliance | ISO 13485:2016, FDA 21 CFR Part 11 (with Magellan Tracker), EU IVD Directive 98/79/EC, RoHS & WEEE |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Infinite® 200 PRO |
| Detection Modes | Up to 8 (Absorbance, Fluorescence Intensity, Time-Resolved Fluorescence, Fluorescence Polarization, Luminescence, AlphaScreen/AlphaLISA®, BRET, TR-FRET/HTRF) |
| Plate Formats | 6–384-well microplates, PCR plates, cuvettes |
| Wavelength Range | 230–1000 nm (monochromator-based) |
| Absorbance Linearity | < ±0.2% deviation |
| Z-axis Auto-Focusing | Yes |
| Gas Control Module (GCM) | Optional O₂/CO₂ regulation for live-cell assays |
| Detector Types | Photomultiplier tube (PMT) for fluorescence/luminescence |
| Software Compliance | Supports 21 CFR Part 11 audit trail, GLP/GMP data integrity features |
| Regulatory Alignment | Designed to support ISO/IEC 17025, CLSI EP12-A2, and USP <1033> validation protocols |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Spark Cyto |
| Automation Level | Fully Automated |
| Detection Modes | Fluorescence Imaging, Brightfield, Multimode Plate Reading (Absorbance, Fluorescence Intensity, Luminescence, Time-Resolved Fluorescence, FRET) |
| Imaging Capabilities | Widefield Epifluorescence, Full-Well Capture per Field, Z-Stacking, Kinetic Time-Lapse, 2D & 3D Cell Culture Compatibility |
| Objectives | 2×, 4×, 10× (Motorized, Auto-Focus Enabled) |
| Fluorescence Channels | 4 Independent Filter Sets (Configurable) |
| Software Platform | SparkControl™ MAGNA with Real-Time Experiment Control (REC), GLP-Compliant Audit Trail, FDA 21 CFR Part 11 Ready |
| Throughput Options | Standalone or Integrated with Tecan Fluent/Genesis Liquid Handling Platforms and Incubation Modules (e.g., Gas-Controlled Multi-Plate Incubator) |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | Spark |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Detection Modes | Absorbance (UV-Vis spectral scanning), Fluorescence Top/Bottom Read (including 3D fluorescence spectral scanning), Time-Resolved Fluorescence (TRF), TRF Spectral Scanning, Fluorescence Resonance Energy Transfer (FRET), Time-Resolved FRET (TR-FRET), Fluorescence Polarization (FP), Luminescence (Glow, Flash, Multicolor, High-Sensitivity Luminescence Spectral Scanning), AlphaScreen®/AlphaLISA®/AlphaPlex®, Real-Time Brightfield Cell Imaging (Cell Counting & Confluence Analysis) |
| Wavelength Range | 200–1000 nm |
| Additional Modules | Cuvette Port (Absorbance), NanoQuant Plate, Temperature Control (RT +3 °C to 42 °C), Integrated Liquid Handling with Heating & Stirring, CO₂ & O₂ Gas Control Module, Humidity Chamber (Volatile Compound Protection), Te-Cool™ Active Cooling (18–42 °C), Automatic Lid Lifting, Built-in QC Tools (IQ/OQ Support), Integrated Spark-Stack™ Microplate Stacker |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | Sunrise |
| Type | Absorbance Microplate Reader |
| Automation Level | Fully Automated |
| Measurement Methods | Single-/Multi-wavelength, Kinetic Assays |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0–3.0 OD (340–399 nm), 0–4.0 OD (400–750 nm) |
| Linearity | 0.000–2.0 OD |
| Detection Speed | Full-plate scan in 5 seconds (12-channel parallel detection) |
| Optical Resolution | 0.001 OD |
| Filter Options | 4-position, 6-position, or continuous monochromator (400–700 nm) |
| Compliance | FDA 21 CFR Part 11 (Magellan Tracker), EU IVD Directive 98/79/EC (Magellan Clinical) |
| Software Platform | Magellan™ (PC & embedded Windows CE versions) |
| Integration Capability | Compatible with Freedom EVO® and Freedom EVOlyzer® automated platforms |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Sunrise |
| Detection Method | Absorbance |
| Function Type | Multifunctional |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Detector Type | Photodiode Array-Based Absorbance Detector |
| Regulatory Compliance | EU In Vitro Diagnostic Directive 98/79/EC |
| Software | Magellan™ v7.x (Multilingual: English, German, French, Italian, Spanish, Russian, Chinese) |
| Design | Modular Base System with Optional Upgrades (Variable Wavelength Selection, Precise Temperature Control, Barcode Reader, Plate Shaking) |
| Intended Use | Clinical Diagnostics, ELISA, Cytotoxicity Assays, Enzyme Kinetics, Quality Control in IVD Laboratories |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Multiskan SkyHigh |
| Pricing | Upon Request |
| Origin | Assembled in Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | MULTISKAN ASCENT |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | Multiskan SkyHigh |
| Detection Method | Absorbance (Photometry) |
| Function Type | Single-Mode |
| Automation Level | Fully Automated Microplate Reader |
| Assay Modes | Endpoint, Kinetic, and Spectrum Scan |
| Curve Fitting Options | Linear, Point-to-Point, Quadratic, Cubic, Four-Parameter Logistic (4PL), Cubic Spline, Two-Parameter Logarithmic |
| Detector Type | Monochromator-Based |
| Wavelength Range | 200–1,000 nm |
| Absorbance Range | Up to 3.0 Abs |
| Absorbance Linearity | 0–2.5 Abs (±2%) |
| Wavelength Scanning Speed | 10 s (200–1000 nm, 1 nm step) |
| Precision | SD < 0.003 Abs or CV < 1.0% |
| Brand | Thermo Fisher |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Varioskan ALF |
| Detection Methods | Absorbance, Turbidimetry, Fluorescence, Luminescence |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan, Kinetic Spectral Scan |
| Detector Types | Photomultiplier Tube (PMT) for fluorescence/luminescence |
| Wavelength Range | 200–1000 nm (monochromator-based) |
| Absorbance Range | 0.000–4.000 OD |
| Sample Formats | 6–384-well microplates, cuvettes, and proprietary ultra-low-volume plates (e.g., NanoDrop-compatible microvolume strips) |
| Brand | Thermo Scientific |
|---|---|
| Origin | Singapore |
| Model | Fluoroskan / Fluoroskan FL / Luminoskan |
| Detection Mode | Fluorescence & Luminescence (Dual-Mode for Fluoroskan FL) |
| Detector Type | Photomultiplier Tube (PMT) |
| Plate Formats | 6–384-well microplates |
| Reading Speed | 18 s per 96-well plate |
| Measurement Modes | Endpoint, Kinetic, Multi-point per well |
| Excitation/Emission Flexibility | Top-read and bottom-read optical paths |
| Dynamic Range | >6 decades |
| Incubation Range | Up to 45 °C with orbital shaking |
| Liquid Handling | Optional integrated reagent dispensers (0, 1, or 2 dispensers) |
| Software | Thermo Scientific SkanIt PC and Cloud-based assay protocol library |
| Compliance | DLReady certified (Luminoskan & Fluoroskan FL), supports GLP/GMP workflows with audit trail capability |
| [Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Multiscan MK3 |
| Optical Range | 340–750 nm (standard configuration: 405, 450, 492, 630 nm) |
| Absorbance Range | 0.000–3.500 A |
| Resolution | 0.001 A |
| Accuracy | ±1% (0–2.0 A) |
| Precision (CV) | <0.2% or ≤0.001 Abs at 0.5 A |
| Read Time | ≤5 seconds per 96-well plate |
| Plate Shaking | Linear vibration, 3 adjustable speeds |
| Dimensions | 140 × 420 × 320 mm (W × D × H) |
| Weight | 11 kg |
| Interface | RS-232 serial port, parallel printer port |
| Light Source | Quartz tungsten halogen lamp |
| Display | 2 × 20-character LCD |
| Keyboard | 30-key membrane keypad |
| Power Supply | 220–240 V, 50/60 Hz] |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | Multiskan FC & Varioskan ALF |
| Detection Modes | Absorbance, Fluorescence (including FRET), Luminescence (including FRET) |
| Wavelength Range | 340–850 nm (Multiskan FC) |
| Plate Formats | 6–384-well microplates, including UV-transparent and ultra-low-volume plates |
| Incubation Temperature | Up to 50 °C |
| Built-in Shaking | Yes |
| Onboard Software | Thermo Scientific SkanIt PC Software (FDA 21 CFR Part 11 compliant with audit trail, user roles, and electronic signature support) |
| Regulatory Compliance | IVD CE-marked (Multiskan FC IVD variant), ISO 13485-aligned design, GLP/GMP-ready workflows |
| Connectivity | USB 2.0, optional Ethernet |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Multiskan FC Microplate Reader |
| Pricing | Available Upon Request |
| Wavelength Range | 340–850 nm |
| Plate Formats | 96-well and 384-well microplates |
| Incubation Temperature | Up to 50 °C |
| Display | Color LCD with Multi-language UI |
| Software | Thermo Scientific SkanIt™ PC Software |
| Interface | USB 2.0 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | FC |
| Detection Method | Absorbance (Photometric) |
| Functionality | Single-mode |
| Automation Level | Semi-automated |
| Measurement Mode | Endpoint Scanning |
| Curve Fitting | Polynomial, Linear, Log-Log, 4-Parameter Logistic (4PL), and Other Standard Functions |
| Detector Type | UV-Visible Photodiode Array |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–6 ABS |
| Linear Range | 0–3 ABS (at 405 nm, 96-well, standard mode) |
| Wavelength Selection Speed | 6 s per wavelength (96-well plate, fast mode) |
| Accuracy | ±1% (0–3 ABS), ±2% (3–4 ABS) at 405 nm |
| Precision (CV) | ≤0.2% (0–3 ABS), ≤1.0% (3–4 ABS), standard mode |
| Optical Resolution | 0.001 ABS |
| Filter Wheel | 8-position, standard filters: 405 nm, 450 nm, 620 nm |
| optional filters available (FWHM | 3–9 nm) |
| Plate Formats | 96-well and 384-well microplates |
| Incubation (optional) | RT +4°C to 50°C |
| Shaking | Linear shaking with three speed settings |
| Display | 480 × 272 pixel color LCD touchscreen |
| Onboard Memory | 100 protocols + 100 result sets (96-well) |
| Interfaces | 3× USB (PC, printer, USB storage) |
| Compliance | RoHS, CE (2002/96/EC), FCC Part 15 Subpart B Class B, IEC 61010-1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Multiskan™ FC |
| Functionality | Absorbance-only microplate reader |
| Automation Level | Fully automated |
| Assay Modes | Endpoint and kinetic |
| Curve Fitting Options | Linear, 4-parameter logistic (4PL), 5-parameter logistic (5PL), quadratic, cubic, log-log, semi-log |
| Detector Type | Photodiode-based UV-Vis spectrophotometer |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–6.0 OD |
| Linearity | ±2% deviation from theoretical value within 0–4.0 Abs (96-well plate, standard mode) |
| Read Speed | 6 seconds per 96-well plate (fast mode) |
| Precision | CV ≤ 0.2% (0–3.0 Abs, standard mode) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA (assembled in Shanghai) |
| Model | MK3 |
| Function Type | Multifunctional |
| Automation Level | Semi-Automatic |
| Measurement Method | Scanning |
| Curve Fitting | Mathematical Functions |
| Detector Type | UV-Vis Photomultiplier Tube (PMT) |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–4.0 ABS |
| Linearity Range | 0–2.0 ABS |
| Wavelength Switching Time | 6 s |
| Photometric Accuracy | ±1% (0–2.0 ABS) |
| Precision (CV) | <0.5% (0–1.5 ABS) |
| Resolution | 0.001 ABS |
| Plate Read Time | ≤5 s per 96-well plate |
| Optical System | Multi-channel fiber-optic detection |
| Filter Capacity | Up to 8 positions, motorized filter wheel |
| Built-in Shaker | Linear, 3 adjustable speeds |
| Dimensions | 140 × 420 × 320 mm |
| Weight | 11 kg |
| Power Supply | 220–240 V, 50/60 Hz |
| Light Source | Tungsten-halogen lamp with spare bulb included |
| Interface | RS-232 serial port, parallel printer port |
| Onboard Display | 2 × 20 character LCD |
| Keyboard | 30-key tactile membrane keypad |
| Data Storage | 64 programmable protocols and calibration curves |
| Software | Windows-based MK3 Control & Analysis Suite (included) |