Microplate Reader
Filter
Showing 31–60 of 100 results
| Brand | Dynamica |
|---|---|
| Model | HALO MPR-96 |
| Origin | Switzerland |
| Wavelength Range | 400–750 nm (MPR-96UV: 340–750 nm) |
| Absorbance Range | 0–4.0 OD |
| Resolution | 0.001 OD |
| Stability | ±0.001 OD (after 15 min warm-up) |
| Accuracy | ±1.0% ±0.01 OD (405 nm, 0.000–2.500 OD) |
| Repeatability | ±0.5% ±0.005 OD (405 nm, 0.000–2.500 OD) |
| Linearity | ±1.0% (405 nm, 0.000–2.500 OD) |
| Filter Positions | 5 (4 fixed + 1 user-selectable, 400–750 nm) |
| Read Time | ≤10 s (single wavelength, 96-well) |
| Plate Formats | 96-well flat, U-bottom, V-bottom |
| Optical Channels | 8 measurement + 1 reference |
| Detector | Silicon photodiode |
| Light Source | Tungsten-halogen lamp |
| Display | Backlit LCD, 320×240 px |
| Incubation (optional) | Ambient +4°C to +50°C, ±0.5°C accuracy |
| Dimensions (W×D×H) | 290×425×200 mm |
| Weight | 15 kg (net), 20 kg (gross) |
| Power | 110–220 V auto-switching, 50/60 Hz, 50 W (standby), 100 W (operational) |
| Brand | Evergreen |
|---|---|
| Origin | Germany |
| Model | 00000 |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Detection Method | Absorbance (Photometric) |
| Wavelength Range | 300–750 nm |
| Absorbance Range | 0–4.0 OD |
| Linearity | ±2.5% or ±0.010 OD (whichever is greater) |
| Wavelength Scanning Speed | 400–750 nm |
| Accuracy | ±0.010 OD (0–4.0 OD range) |
| Detection System | 8-Channel Fiber-Optic Array |
| Measurement Time | ≤5 s per 96-well plate |
| Plate Compatibility | Standard 96-well microplates (flat, round, or V-bottom) |
| Software Interface | Windows-based GUI with touch-screen support |
| Data Storage | ≥10,000 assay results and ≥100 user-defined protocols |
| Compliance | Designed for ISO 13485-aligned workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LumiStation 1800 |
| Functionality | Dedicated Chemiluminescence Detection |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting | Linear Regression |
| Detector | Photon-Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 300–650 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Absorbance Linearity | 0.000–2.000 Abs |
| Single-Wavelength Kinetic Read Time | 6 sec per well |
| Sensitivity | 7 amol ATP per well |
| Plate Formats | 96-well and 384-well microplates |
| Incubation Range | Ambient +2 °C to 65 °C |
| Shaking Modes | Linear, Orbital, Cross |
| Integration Time | User-Configurable |
| Software Interface | USB-Controlled Data Acquisition & Analysis Workstation |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LumiStation 1800Plus |
| Price Range | USD 7,000–14,000 |
| Function Type | Dedicated Chemiluminescence Detection |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Dual-Read, Kinetic |
| Curve Fitting | Linear Regression |
| Detector | Photon-Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 300–650 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Absorbance Linearity | 0.000–2.000 Abs |
| Single-Wavelength Kinetic Read Time | 6 sec |
| Sensitivity | 7 amol ATP per well |
| Microplate Formats | 96-well & 384-well |
| Incubation Range | Ambient +2 °C to 65 °C |
| Shaking Modes | Linear, Orbital, Cross |
| Data Interface | USB 2.0 |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP Audit Trail, IQ/OQ/PQ Ready |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1000F |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 190–1000 nm |
| Absorbance Range | 0–6 Abs |
| Linearity Range | 0–3 Abs (±2%) |
| Wavelength Measurement Speed | 6 s per 96-well plate (fast mode) |
| Precision | CV ≤ 0.2% (0–3 Abs) |
| Detector Type | Photodiode |
| Filter Capacity | Up to 16 positions (standard: 405, 450, 620 nm) |
| Plate Format | Standard 96-well microplates |
| Resolution | 0.001 Abs |
| Incubation Option | Optional heated incubator module (MF-10) |
| Control Interface | 7-inch capacitive touchscreen |
| Data Storage | 100 protocols + 100 × 96-well datasets |
| Connectivity | 3× USB (PC, USB drive, printer) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1500 |
| Detection Principle | Monochromator-based UV-Vis Absorbance |
| Wavelength Range | 190–1000 nm (1 nm step) |
| Optical Density Range | 0–4.000 OD |
| OD Linearity | ±0.01% in 0–2.0 OD |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Spectral Bandwidth | 2.5 nm (2–10 nm customizable) |
| Stray Light | <0.01% (@230 nm) |
| OD Precision | CV <0.5% (@450 nm) |
| Read Time | 20 s per 96-well plate (dual-wavelength) |
| Plate Format | Standard and UV-transparent 96-well microplates |
| Detector Type | UV-Vis photodiode array |
| Light Source | Xenon flash lamp |
| Interface | 7-inch capacitive touchscreen + USB data export |
| Software | Onboard firmware with kinetic, endpoint, spectral scan, and curve-fitting modes (linear, point-to-point) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1900 |
| Detection Principle | Absorbance (Photometric) |
| Wavelength Range | 190–900 nm |
| Optical Density Range | 0–4.000 OD |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Spectral Bandwidth | 2–10 nm (customizable) |
| Incubation Temperature Range | Ambient to 45 °C |
| Plate Formats | Standard 96-well and UV-transparent 96-well microplates |
| Detection Modes | Single-, Dual-, and Multi-wavelength |
| Data Interface | USB 2.0 |
| Software Compliance | FDA 21 CFR Part 11, IQ/OQ/PQ protocols, GLP/GMP-ready |
| Optional Accessories | Dual-cuvette adapter plate (NA-10), incubation-shaking module (MF-10), multi-mode washer (MX-10), LIMS server (WS-10) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ReadMax 1900 |
| Price Range | USD 7,000–14,000 |
| Functionality | Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, and Spectral Scan |
| Curve Fitting | Linear Regression Only |
| Detector Configuration | Dual-Detector System (Sample + Reference) |
| Wavelength Range | 190–1000 nm |
| Absorbance Range | 0–4.000 OD |
| Linearity Range | 0–4.0 Abs |
| Kinetic Measurement Speed | 6 sec per single wavelength |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Temperature Control Range | Ambient +2 °C to 65 °C |
| Plate Compatibility | Standard 96-well and UV-transparent 96-well microplates |
| Light Source | Pulsed Xenon Lamp |
| Cuvette Port | Integrated Single-Cell Optical Path for Standalone UV-Vis Spectrophotometry |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1900Plus |
| Detection Principle | Absorbance (Photometric) |
| Wavelength Range | 190–1000 nm |
| Optical Density Range | 0–4.000 OD |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 2–10 nm (configurable) |
| Temperature Control Range | Ambient to 65 °C |
| Plate Formats | Standard 96-well |
| Cuvette Mode | Integrated 1-cm pathlength cuvette port |
| Detection System | Dual photodiode detector (sample + reference) |
| Light Source | Pulsed xenon lamp |
| Kinetic & Spectral Scan Modes | Supported |
| Software Compliance | FDA 21 CFR Part 11, IQ/OQ/PQ validated, GLP/GMP-ready |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1900Plus |
| Function Type | Absorbance-Only |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting | Linear Regression |
| Detector Configuration | Dual-Channel (Sample + Reference) |
| Wavelength Range | 190–1000 nm |
| Absorbance Range | 0–4.000 OD |
| Absorbance Linearity | 0–4.000 OD |
| Kinetic Measurement Speed | 6 sec per wavelength |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Temperature Control Range | Ambient +2°C to 65°C |
| Plate Compatibility | Standard 96-well and UV-transparent 96-well microplates |
| Light Source | Xenon Flash Lamp |
| Cuvette Port | Integrated UV-Vis spectrophotometer path |
| Software Compliance | FDA 21 CFR Part 11, IQ/OQ/PQ validated, GLP/GMP-ready audit trail |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 500F |
| Function Type | Absorbance-Only |
| Automation Level | Fully Automated |
| Assay Method | Endpoint |
| Calibration Curve Types | Single-Point & Linear Regression |
| Detector Type | Photodiode Array |
| Wavelength Range | 340–900 nm |
| Absorbance Range | 0–6 Abs |
| Linearity Range | 0–3 Abs (±2%) |
| Wavelength Switching Time | 6 s per filter |
| Precision | CV ≤ 0.2% (0–3 Abs) |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotech Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3000AL |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting | Linear regression |
| Detection Technologies | UV-Vis Absorbance, Chemiluminescence |
| Wavelength Range | 190–1000 nm (monochromator-based) |
| Absorbance Range | 0–4 OD (96-well, 450 nm) |
| Absorbance Linearity | 0–4 OD (±2% at 450 nm, 96-well) |
| Wavelength Scanning Speed | 6 sec per wavelength (kinetic mode) |
| Chemiluminescence Sensitivity | <7 amol ATP/well (flash-type ATP assay), dynamic range >7 decades |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Temperature Control | Ambient +2°C to 65°C |
| Plate Types | 96-well and 384-well microplates |
| Detection Detectors | Photodiode (absorbance), Photon-counting PMT (chemiluminescence) |
| Light Source | Xenon flash lamp |
| Plate Agitation | Linear, orbital, and circular shaking (adjustable amplitude) |
| Data Interface | USB 2.0 |
| Optional Modules | Dual-channel liquid dispenser (10–1000 µL), audit trail module, incubation shaker (MF-10) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3000FA |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting | Linear regression |
| Detection Modes | Fluorescence (top/bottom read), UV-Vis Absorbance |
| Wavelength Range | 190–1000 nm (monochromator-based) |
| Absorbance Range | 0–4 Abs (96-well, 450 nm) |
| Absorbance Linearity | ±2% (0–4 Abs, 96-well, 450 nm) |
| Kinetic Read Speed | 6 sec per wavelength (single-wavelength) |
| Fluorescence Sensitivity | Top-read < 0.5 fmol FITC/well (384-well plate) |
| Dynamic Range | >6 decades (top-read), >5.5 decades (bottom-read) |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | < ±0.2 nm (fluorescence), ±1.0 nm (absorbance) |
| Excitation Range | 190–1000 nm |
| Emission Range | 270–850 nm |
| Bandwidth Options | 10 nm or 20 nm |
| Light Source | Xenon flash lamp |
| Temperature Control | Ambient +2°C to 65°C |
| Plate Formats | 96-well and 384-well standard (custom formats available) |
| Shaking Modes | Linear, orbital, circular with adjustable amplitude |
| Detector Configuration | Dual PMT (sample + reference) for fluorescence |
| Data Interface | USB 2.0 |
| Software | SuPerMax Workstation (with audit trail option) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3000FL |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting | Linear, Log-Log, Four-Parameter Logistic (4PL), Five-Parameter Logistic (5PL), Quadratic, Cubic, Spline |
| Detection Modes | Fluorescence (Top/Bottom Read), Luminescence (Photon-Counting PMT) |
| Wavelength Range | 190–1000 nm (Monochromator-Based) |
| Absorbance Range | 0.000–2.000 OD |
| Absorbance Linearity | ±0.01 OD (0.000–2.000 OD) |
| Wavelength Accuracy | < ±0.2 nm |
| Wavelength Resolution | 1 nm |
| Excitation Range | 190–1000 nm |
| Emission Range | 270–850 nm |
| Fluorescence Sensitivity | < 0.5 fmol FITC/well (Top Read, 384-well) |
| Luminescence Sensitivity | < 7 amol ATP/well (Flash Reaction) |
| Dynamic Range | > 6 decades (Fluorescence, Top Read) |
| Temperature Control | Ambient +2°C to 65°C |
| Plate Formats | 96-, 384-well standard |
| Shaking Modes | Linear, Orbital, Dual-Axis |
| Light Source | Xenon Flash Lamp |
| Data Interface | USB 2.0 |
| Software Compliance | Audit Trail (optional), User Access Control, Electronic Signature Support (21 CFR Part 11-ready configuration) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3100 |
| Function Type | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting | Linear |
| Detectors | Photomultiplier Tube (PMT) for Fluorescence & Luminescence, Photodiode for Absorbance |
| Wavelength Range | 190–1000 nm (monochromator-based) |
| Absorbance Range | 0–4 Abs (96-well, 450 nm) |
| Absorbance Linearity | 0–4 Abs (±2% at 450 nm, 96-well) |
| Wavelength Accuracy | ±1.0 nm |
| Kinetic Read Time (Single Wavelength) | 6 sec |
| Excitation Range | 190–1000 nm |
| Emission Range | 270–850 nm |
| Fluorescence Sensitivity (Top Read) | <0.5 fmol FITC/well (384-well) |
| Chemiluminescence Sensitivity | <7 amol ATP/well (flash reaction) |
| Temperature Control | Ambient +2°C to 65°C |
| Plate Formats | 96-, 384-well (custom formats supported) |
| Reading Modes | Top & Bottom |
| Light Source | Xenon Flash Lamp |
| Data Interface | USB 2.0 |
| Software | SuPerMax Workstation with Audit Trail (optional) |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotechnology Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3200 |
| Detection Modes | Absorbance, Fluorescence, Luminescence |
| Automation Level | Fully Automated |
| Wavelength Range | 190–1000 nm (Abs/Fluor Excitation), 270–850 nm (Fluor Emission), 300–650 nm (Luminescence) |
| Absorbance Linearity | 0–4 Abs (96-well, 450 nm), ±2% |
| Fluorescence Sensitivity | < 0.4 fmol FITC/well (top-read, 384-well plate) |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | < ±0.2 nm |
| Temperature Control | RT+2°C to 65°C |
| Plate Formats | 6- to 384-well microplates |
| Read Modes | Top & Bottom Reading |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3500 |
| Automation Level | Fully Automated |
| Detection Modes | Absorbance (190–1000 nm, monochromator-based), Fluorescence (top/bottom reading, TRF, FP), Luminescence (photon-counting PMT) |
| Detectors | Photodiode, Standard PMT, Photon-Counting PMT |
| Excitation Sources | Tungsten-halogen lamp, Xenon flash lamp |
| Wavelength Selection | Dual-path — monochromator or filter-based |
| Curve Fitting | Linear, quadratic/cubic/quartic polynomial, 4PL/5PL, log, exponential, double-logarithmic |
| Incubation Range | Ambient to 65 °C (±0.2 °C uniformity at 37 °C) |
| Plate Formats | 6–1536-well microplates |
| Software | Integrated workstation with formula editor, audit trail, GLP-compliant data handling, and automation-ready API |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax-3100 |
| Function Type | Multimode |
| Automation Level | Fully Automated Microplate Reader Workstation |
| Assay Modes | Endpoint Fluorescence, Absorbance, Chemiluminescence (ELISA/EIA) |
| Curve Fitting Options | Multiple nonlinear regression models (e.g., 4PL, 5PL, linear, quadratic, log-log) |
| Detectors | Photodiode (Absorbance), PMT (Fluorescence), Photon Counting PMT (Chemiluminescence) |
| Wavelength Range | 190–1000 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Excitation & Emission Monochromators | Dual high-resolution grating monochromators |
| Bandwidth | Adjustable from 2 to 20 nm |
| Temperature Control Range | Ambient to 65 °C |
| Plate Formats | Standard 96-well (customizable to 24-, 384-, 1536-well) |
| Dispensing Capability | Dual-channel liquid handler (expandable to quad-channel) |
| Reading Modes | Top-read and bottom-read fluorescence |
| Kinetic & Spectral Scanning | Supported |
| Software Compliance | IQ/OQ/PQ validated |
| Brand | Shanghai Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Absorbance-Based Microplate Reader |
| Automation Level | Fully Automated |
| Wavelength Range | 190–1000 nm |
| Optical System | Monochromator-Based (Grating) with Dual-Detector Architecture (8 Sample + 8 Reference Channels) |
| Temperature Control | Ambient to 65 °C (Uniformity: ±0.2 °C at 37 °C) |
| Built-in Functions | Plate Incubation, Orbital Shaking |
| Optional Module | Standalone Cuvette Holder (1-cm Pathlength) |
| Pathlength Correction | Integrated Optical Pathlength Conversion Algorithm (Converts Microplate OD to Equivalent 1-cm Cuvette OD) |
| Data Analysis Models | Linear, Quadratic, Cubic, Quartic, 4-Parameter Logistic (4PL), 5-Parameter Logistic (5PL), Logarithmic, Exponential, Double-Logarithmic Fitting |
| Software | PC-Based Control & Analysis Suite with Formula Editor, Audit Trail, and Export (CSV, Excel, PDF) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | MTS 2/4 Digital |
| Orbital Motion Type | Circular |
| Orbit Diameter | 3 mm |
| Max. Load Capacity (incl. clamps) | 2 or 4 microplates |
| Motor Input Power | 35 W |
| Motor Output Power | 13.2 W |
| Continuous Operation Duty Cycle | 100 % |
| Min. Adjustable Speed | 50 rpm |
| Speed Range | 0–1100 rpm |
| Speed Display | Analog Scale |
| Timer Function | Yes |
| Timer Display | 7-segment LED |
| Timer Setting Range | 1–99 min |
| Operation Modes | Timed or Continuous |
| Microplate Compatibility | Standard 96-well and 384-well plates |
| Dimensions (W × D × H) | 185 × 105 × 320 mm |
| Weight | 2.7 kg |
| Ambient Operating Temperature | 5–40 °C |
| Max. Relative Humidity | 80 % (non-condensing) |
| Ingress Protection Rating | IP21 (per DIN EN 60529) |
| Input Voltage | 220–240 V / 100–120 V |
| Frequency | 50/60 Hz |
| Total Instrument Power Consumption | 45 W |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio600 |
| Detection Method | Absorbance Photometry |
| Wavelength | 600 nm |
| Wavelength Accuracy | ±4.0 nm |
| Spectral Bandwidth | 8 nm |
| Absorbance Range | −0.3 to 3.0 A |
| Absorbance Accuracy | ±0.005 A (0–0.5 A), ±0.01 A (0.5–1.0 A) |
| Absorbance Repeatability | 0.002 A |
| Sample Volume | ≥200 µL |
| Light Source | Long-life LED (Cold White) |
| Detector | Silicon Photodiode |
| Display | 7-inch Color Touchscreen (1024 × 600) |
| Data Storage | Internal (128 MB) + USB/SD Card Export |
| Connectivity | USB-B |
| Power Supply | AC 100–240 V, 50/60 Hz or DC 12 V / 3 A |
| Dimensions (W×D×H) | 290 × 260 × 100 mm |
| Weight | 2.15 kg |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | Keebio-5000PRO |
| Detection Method | Absorbance (UV-Vis) |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Detector Type | UV-Visible Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Absorbance Range | 0–4.0 A |
| Absorbance Linearity | ±2% (0–2.5 A) |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 ± 0.4 nm |
| Stray Light | ≤0.05% at 220 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Absorbance Precision | SD < 0.003 A or CV < 1.0% (at 450 nm) |
| Absorbance Accuracy | ±(1.0% + 0.003 A) for 0–2.0 A |
| Plate Formats | 96-well and 384-well microplates |
| Cuvette Compatibility | 1-cm standard quartz/glass cuvettes |
| Incubation Temperature Range | Ambient +5°C to 45°C (±0.5°C uniformity at 37°C) |
| Reading Time | 10 s per 96-well plate, 20 s per 384-well plate |
| Plate Shaking | Linear shaking with low/medium/high speed settings |
| Display | 10-inch color capacitive touchscreen |
| Interfaces | RS232, USB |
| Dimensions (W×D×H) | 503 × 376 × 330 mm |
| Weight | 15 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Keebio |
|---|---|
| Model | MR200 |
| Type | Automated Absorbance Microplate Reader |
| Wavelength Range | 340–800 nm |
| Absorbance Range | 0.000–4.000 A |
| Accuracy | ≤ ±0.005 A or ±0.2% T |
| Light Source | High-Stability LED (20,000 h lifetime) |
| Optical Path | 8-Channel Simultaneous Detection |
| Plate Format | Standard 96-well (flat/U/V-bottom compatible) |
| Read Speed | ≤3 sec/plate (single wavelength), ≤6 sec/plate (dual wavelength) |
| Filter Positions | 10 (standard: 405, 450, 492, 630 nm |
| Bandwidth | ≤8 nm (FWHM) |
| Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Repeatability | ≤0.2% (A) or ≤0.2% T |
| Drift | ≤±0.002 A or ≤0.5% T / 10 min |
| Data Storage | 2,000 plates (96-well), ≥500 assay protocols |
| Interface | USB 2.0, RS232, parallel printer port, USB mouse/keyboard support |
| Display | 7-inch color TFT LCD touchscreen |
| Operating Environment | 5–40 °C, 15–80% RH |
| Dimensions | 475 × 350 × 210 mm |
| Net Weight | 10 kg |
| Brand | Kehua Biosciences (KHB) |
|---|---|
| Origin | Shanghai, China |
| Model | ST-960 |
| Detection Method | Absorbance (Photometric) |
| Function Type | Multifunctional |
| Automation Level | Fully Automatic |
| Measurement Modes | Absorbance, Factor Calculation, Standard Concentration, Standard Curve, Single-Threshold, Dual-Threshold, Categorical Classification, Column Subtraction, Point-to-Point |
| Optical System | 8-Channel High-Precision Fiber Optic Path |
| Wavelength Range | 400–1000 nm |
| Absorbance Range | 0.000–4.500 Abs |
| Linearity Range | 0.000–3.000 Abs |
| Wavelength Accuracy | ±5 nm (at center wavelength) |
| Detection Speed | <5 seconds per 96-well plate (single or dual wavelength) |
| Resolution | 0.001 Abs |
| Light Source | Long-Life LED Cold Light Source |
| Display | 7-inch True-Color Touchscreen (840 × 480 resolution) |
| Filter Positions | 8 positions |
| Data Storage | Internal high-capacity memory |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Model | ST-360 |
| Detection Method | Absorbance (Photometric) |
| Function Type | Multifunctional |
| Automation Level | Fully Automatic |
| Assay Modes | Absorbance, Factor Calculation, Standard Concentration, Standard Curve, Single-Threshold, Dual-Threshold, Categorical Classification, Column Subtraction, Point-to-Point |
| Measurement Configurations | Single-Wavelength, Dual-Wavelength, Dual-Time, Kinetic, Multi-Wavelength, PC-Controlled |
| Light Source | Halogen Lamp |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0.000–4.000 A |
| Linearity (0–3 A) | ≥0.99 |
| Wavelength Measurement Speed | 3 s per wavelength |
| Resolution | 0.001 A |
| Repeatability | ≤±0.005 A |
| Optical Channels | 8-channel fiber-optic detection (optional reference channel) |
| Filter Positions | 8 positions (standard: 405, 450, 492, 630 nm |
| optional | 414, 546, 578, 690 nm) |
| Plate Handling | 96-well microplates only |
| Vibration Function | Adjustable amplitude and duration |
| Display | Large LCD with full-dot-matrix Chinese interface |
| Data Storage | 500 assay protocols + 1,100 full 96-well runs (expandable) |
| Software | Integrated qualitative/quantitative analysis suite with customizable equations, curve-fitting models (linear, quadratic, log-log, 4PL, 5PL), QC tools (Levey-Jennings, Westgard rules), and user-defined plate layout templates |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | PlateDirect A96 |
| Detection Method | Absorbance (Optical Density) |
| Function Type | Single-Mode Absorbance Reader |
| Automation Level | Fully Automated |
| Measurement Mode | Endpoint and Kinetic Scanning |
| Microplate Format | 96-well, Flat-Bottom |
| Wavelength Options | Variant 1: 405 nm, 450 nm, 492 nm, 620 nm |
| Variant 2 | 492 nm, 570 nm, 600 nm, 650 nm |
| Absorbance Range | 0–4.0 OD |
| Resolution | 0.001 OD |
| Read Time | ≤5 seconds per 96-well plate |
| Brand | Molecular Devices |
|---|---|
| Model | MultiWash-C |
| Type | Automated Microplate Washer |
| Plate Format | 96-well (flat-bottom, U-bottom, V-bottom) |
| Dispense Volume Range | 50–3000 µL (in 50 µL increments) |
| Accuracy & Precision @ 300 µL | ≤3% |
| Residual Volume | ≤1 µL/well |
| Wash Cycle Time (3 cycles, 3000 µL/well) | <90 s (12-channel head), <125 s (8-channel head) |
| Oscillation | 3 adjustable frequencies |
| Aspiration/Dispense Speed | 3-speed control |
| Onboard Storage | 100 programs, up to 99 steps per program |
| Dimensions (W×H×D) | 46 × 30 × 40 cm |
| Weight (packed) | 13 kg |
| Power Input | 100–240 V, 50–60 Hz |
| Integrated Sensors | Liquid level detection for 2 × 4 L wash bottles and 1 × 10 L waste bottle |
| Compliance | Designed for GLP-compliant ELISA workflows |
| Software | Standalone touchscreen interface, no external PC required |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Model | QPix FLEX |
| Detection Method | Fluorescence Intensity |
| Functionality | Multimodal |
| Automation Level | Fully Automated |
| Assay Type | Automated Microbial Identification & Colony Isolation |
| Detector Type | Fluorescence Imaging Sensor |
| Sample Handling | Integrated Liquid Handling, Streaking, Plating, and Colony Picking |
| Dimensions | Compact Footprint (Designed for Benchtop & Anaerobic Chamber Integration) |
| Traceability | 2D Barcode Scanning for Microplate & Pick Log Registration |
| Compliance Context | Supports GLP/GMP-aligned workflows with full audit trail capability |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Model | SpectraMax 190 |
| Detection Method | Absorbance (UV-Vis) |
| Automation Level | Fully Automated |
| Wavelength Range | 190–850 nm (1 nm step) |
| Minimum Bandwidth | 2 nm |
| Absorbance Range | 0–4.0 OD |
| Pathlength Correction | Patented PathCheck™ sensor (temperature-independent, converts to 1-cm equivalent) |
| Detection Channels | 8-sample + 1-reference photodiode array |
| Temperature Control | Ambient +4°C to 45°C (±0.5°C accuracy) |
| Orbital Shaking | Linear or orbital, programmable speed/amplitude |
| Microvolume Capability | SpectraDrop™ module (2 µL/sample, 64 wells/scan, dsDNA sensitivity: 2 ng/µL) |
| Software | SoftMax Pro® 7 (GLP-compliant, 21 CFR Part 11 ready, audit trail, 19 curve-fit models, custom equation editor) |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | SpectraMax iD3 |
| Detection Methods | Absorbance, Fluorescence, Luminescence |
| Functionality | Multi-mode |
| Automation Level | Fully Automated |
| Assay Formats | Endpoint, Kinetic, Scanning |
| Curve Fitting | SoftMax Pro Software (Log-Log, 4PL, 5PL, PLA) |
| Detector Type | PMT and Photodiode |
| Wavelength Ranges | Absorbance 230–1000 nm |
| Absorbance Range | 0–4.0 OD |
| Linearity | ±0.010 OD (0–2.0 OD) |
| 96-Well Absorbance Read Time | ≤25 sec |
| Temperature Control | Ambient to 65 °C |
| Plate Formats | 6–384-well, SpectraDrop™ Microvolume Plates |
| Scan Density | Up to 20 × 20 wells/plate |
| Optical System | Dual-monochromator (QuadraGrating™), Xenon Flash Lamp, Cooled (−5 °C) PMT |
| Injection System | Dual SmartInject™ Reagent Injectors with Overflow Protection |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready via SoftMax Pro GxP Edition |