Oil Content Analyzer
Filter
Showing 61–90 of 202 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-dispersive Infrared (NDIR) Absorption |
| Extractant | S-316 (OCMA-350) / H-997 (OCMA-355) |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Optical Path | Quartz Cuvette (200 mm path length) |
| Detector | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C serial port, parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Standard Accessories | Covered quartz cuvette, power cord, heavy oil standard (B-grade), 2 A fuse, 10 mL syringe, 25 µL syringe |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-Dispersive Infrared (NDIR) Absorption |
| Extractant | S-316 (OCMA-350) / H-997 (OCMA-355) |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Optical Path | Quartz Cuvette (200 mm path length) |
| Detector | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C serial port & parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Weight | Approx. 8.5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-Dispersive Infrared (NDIR) Absorption |
| Extractant | S-316 (OCMA-350) / H-997 (OCMA-355) |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Optical Detector | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C port & parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Sample Cell | 200-mm pathlength quartz cuvette |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-Dispersive Infrared (NDIR) Absorption |
| Extractant | S-316 (OCMA-350) / H-997 (OCMA-355) |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Detector Type | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C serial port, parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Sample Cell | 200 mm pathlength quartz cuvette |
| Minimum Detectable Concentration | 0.1 ppm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-dispersive Infrared (NDIR) Absorption |
| Extraction Solvent | OCMA-350 — S-316 |
| Measurement Range | 0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs |
| Repeatability | ±0.4 mg/L ±1 digit (0–9.9 mg/L), ±2.0 mg/L ±1 digit (10.0–99.9 mg/L), ±4 mg/L ±1 digit (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Detector | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C port, parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 mm (W) × 200 mm (H) × 285 mm (D) |
| Sample Cell | 200 mm pathlength quartz cuvette |
| Minimum Detection Limit | 0.1 ppm (as oil) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L |
| Detection Limit | < 0.1 mg/L (as defined per ASTM D7066 and ISO 9377-2) |
| Accuracy | ±1 mg/L (at 10–100 mg/L range) |
| Resolution | 0.01 mg/L (0–99.9 mg/L) |
| Measurement Frequency | One analysis per 60 seconds (typical cycle time including extraction, separation, and quantification) |
| Solvent | S-316 (1,1,2-trichloro-1,2,2-trifluoroethane) |
| Sample-to-Solvent Ratio | 2:1 (v/v) |
| Data Storage Capacity | 300 measurement records with timestamp, operator ID, and calibration history |
| Compliance | Designed to meet EPA Method 1664A, ISO 9377-2, JIS K 0102, and supports GLP/GMP audit trails when paired with optional PC software |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-555 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, single-range) |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extraction Solvent | S-316 (trichloroethylene-free, certified for oil-in-water analysis) |
| Sample Throughput | Fully automated extraction + NDIR quantification per cycle |
| Compliance | Designed to support EPA Method 1664A (modified), ISO 9377-2, and JIS K 0102 reference frameworks |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption after Solvent Extraction |
| Measurement Range | 0–200 mg/L |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extractant | S-316 (trichloroethylene-free chlorinated solvent) |
| Compliance | ASTM D7066, ISO 9377-2 (aligned), EPA Method 1664B (extraction protocol compatible) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-550 |
| Instrument Type | Portable |
| Measurement Principle | Fluorometric Detection (S-316 solvent extraction followed by non-dispersive infrared absorption) |
| Measurement Range | 0–200 mg/L |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Compliance | Designed for ASTM D7066, ISO 9377-2, and EPA Method 1664B-aligned workflows |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extractant | S-316 (trichloroethylene-free chlorinated solvent) |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L |
| Resolution | 0.1 mg/L |
| Extraction Solvent | S-316 (Tetrachloroethylene) |
| Repeatability | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Solvent Extraction + Non-Dispersive Infrared (NDIR) Absorption |
| Measurement Range | 0–200 mg/L (dynamic, auto-ranging) |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±0.1 mg/L (at low range), ±4 mg/L (at 100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Sampling Frequency | 1 measurement per minute |
| Extractant | S-316 (OCMA-500) or H-997 (OCMA-505) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L), ±2 mg/L ±1 digit (10–100 mg/L), ±4 mg/L ±1 digit (100–200 mg/L) |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500/505 & OCMA-550/555 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared Absorption (NDIR) at ~3.4 µm |
| Measurement Range | 0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs (absorbance) |
| Detection Limit | < 0.1 ppm (equivalent to < 0.1 mg/L) |
| Accuracy | ±0.2 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L (0–99.9 mg/L), 1 mg/L (100–200 mg/L) |
| Sampling Frequency | 1 measurement per 2 minutes (0.5 Hz) |
| Extractant Compatibility | S-316 or H-997 chlorinated solvents |
| Calibration | Automatic zero and span calibration (OCMA-500/505) |
| Compliance | Designed for ASTM D7066, ISO 9377-2, and EPA Method 1664B workflows |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Laboratory Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption after Solvent Extraction |
| Measurement Range | 0–200 mg/L |
| Detection Limit | Not Specified |
| Accuracy | ±0.1 mg/L (0–99.9 mg/L) |
| Resolution | 0.1 mg/L (0–9.9 mg/L) |
| Measurement Cycle | One analysis per minute |
| Extractant | HORIBA H-997 solvent |
| Sample-to-Extractant Ratio | 2:1 (v/v) |
| Data Storage Capacity | 300 measurements |
| Display | 3.5-inch backlit color LCD |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 200 × 313 × 342 mm |
| Weight | 7 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Laboratory Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, single-range) |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extractant | HORIBA H-997 Solvent |
| Integrated Sample Extraction | Yes |
| Compliance | ASTM D7066, ISO 9377-2, EPA Method 1664 (compatible), GLP/GMP-ready data logging |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 / OCMA-555 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, auto-ranging), 0–1000 mg/kg, 0–1 Abs |
| Accuracy | ±1 mg/L |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L) |
| Extractant | HORIBA H-997 Solvent |
| Optional Accessory | SR-305 Solvent Regenerator |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Spectrophotometry (with solvent extraction and non-dispersive infrared detection) |
| Measurement Range | 0–200 mg/L (dynamic full-scale range) |
| Detection Method | Solvent extraction followed by non-dispersive infrared (NDIR) absorption analysis |
| Sample Matrix | Freshwater, seawater, and industrial wastewater |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L) |
| Compatible Extraction Solvents | S-316 (for OCMA-550 configuration) or H-997 (for OCMA-555 configuration) |
| Optional Accessory | Solvent Regenerator SR-305 (activated carbon + activated alumina column-based regeneration system) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, single-range), 0–1000 mg/kg, 0–1 Abs |
| Accuracy | ±1 mg/L (at 200 mg/L full scale) |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L), ±2 mg/L ±1 digit (10–100 mg/L), ±4 mg/L ±1 digit (100–200 mg/L) |
| Extractant | HORIBA H-997 solvent |
| Optional Accessory | Solvent Regenerator SR-305 (activated carbon + activated alumina column) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Solvent Extraction Followed by Non-Dispersive Infrared (NDIR) Absorption |
| Measurement Range | 0–200 mg/L |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±1% of reading or ±0.1 mg/L (whichever is greater) |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L) |
| Extractant | HORIBA H-997 Solvent |
| Optional Accessory | SR-305 Solvent Regenerator |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 / OCMA-550 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic full-scale) |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extraction Solvent | HORIBA H-997 |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic full-scale) |
| Resolution | 0.1 mg/L |
| Detection Method | Solvent Extraction Followed by NDIR Absorption Analysis |
| Extractant for OCMA-505 | H-997 |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L), ±2 mg/L ±1 digit (10–100 mg/L), ±4 mg/L ±1 digit (100–200 mg/L) |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Solvent Extraction + Non-Dispersive Infrared (NDIR) Absorption |
| Detection Range | 0–200 mg/L |
| Extractant | H-997 |
| Repeatability | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Compliance | Designed for ASTM D7066, ISO 9377-2, and EPA Method 1664B alignment |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (oil in water), 0–1000 mg/kg (oil in soil/sludge), 0–1 Abs (absorbance) |
| Accuracy | ±1 mg/L (at 10–100 mg/L range) |
| Resolution | 0.1 mg/L (0–99.9 mg/L), 1 mg/L (100–200 mg/L) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L) |
| Extractant | HORIBA H-997 solvent |
| Optional Accessory | Solvent Regenerator SR-305 (activated carbon + activated alumina column) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, auto-ranging), 0–1000 mg/kg, 0–1 Abs |
| Detection Limit | < 0.2 mg/L |
| Accuracy | ±1% of reading (mg/L) |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Sampling Frequency | 0.2 samples/min |
| Extractant | HORIBA H-997 solvent |
| Compliance | ASTM D7066, ISO 9377-2 (oil-in-water), EPA Method 1664 (modified), JIS K 0102 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505H |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (oil in water), 0–1000 mg/kg (oil in soil/sludge), 0–1 Absorbance |
| Accuracy | ±1% of reading (at 10–100 mg/L), ±4 mg/L + 1 digit (at 100–200 mg/L) |
| Resolution | 0.1 mg/L (0–99.9 mg/L), 1 mg/L (100–200 mg/L) |
| Repeatability | ±0.2 mg/L + 1 digit (0–10 mg/L), ±2 mg/L + 1 digit (10–100 mg/L), ±4 mg/L + 1 digit (100–200 mg/L) |
| Extractant | HORIBA H-519 solvent |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-550 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Fluorescence Spectrophotometry |
| Measurement Range | 0–200 mg/L |
| Detection Limit | <0.2 mg/L |
| Accuracy | ±0.4 mg/L ±1 digit (0–9.9 mg/L) |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Measurement Frequency | 1 measurement per minute |
| Cell Material | Quartz |
| Cell Path Length | 20 mm |
| Extraction Solvent | S-316 (reusable) |
| Solvent Volume per Test | 6.5 mL |
| Display | 3.5-inch color LCD (320 × 240 pixels, backlight) |
| Data Storage | Up to 300 measurement records |
| Output Interface | USB flash drive export |
| Power Supply | 100–240 V AC ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 253 × 253 × 195 mm |
| Weight | 5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-550 |
| Principle | Non-Dispersive Infrared (NDIR) Absorption with S-316 Solvent Extraction |
| Measurement Range | 0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs |
| Accuracy | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Resolution | 0.1 mg/L (equivalent to 0.1 ppm in aqueous phase) |
| Detector | Thermoelectric Sensor |
| Display | Backlit LCD with Timestamp |
| Interface | RS-232C, Parallel Printer Port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Sample Cell | 200 mm Pathlength Quartz Cuvette |
| Compliance | ASTM D7066, ISO 9377-2 (oil-in-water), USP <1058> (instrument qualification framework), GLP/GMP-ready data logging |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-550 |
| Instrument Type | Laboratory |
| Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic full-scale) |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extractant | S-316 (trichloroethylene substitute) |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-550 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectrophotometry |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Accuracy | ±1% of reading (at 1 mg/L level) |
| Resolution | 0.1 mg/L (for 0–99.9 mg/L range) |
| Repeatability | ±0.4 mg/L ±1 digit (0–9.9 mg/L), ±2.0 mg/L ±1 digit (10.0–99.9 mg/L), ±4 mg/L ±1 digit (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Detector | Thermopile Sensor |
| Light Source | IR Emitter at ~3.4 µm |
| Solvent Compatibility | S-316 (non-absorbing at 3.4 µm) |
| Display | Backlit LCD with timestamping |
| Data Interface | RS-232C serial port & parallel printer port |
| Dimensions | 250 mm × 200 mm × 285 mm (W × H × D) |
| Power Supply | 230 V AC, 50 Hz |
| Standard Cell | 20 mm pathlength quartz cuvette |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-550 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectrophotometry |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Detection Limit | 0.3 mg/L |
| Accuracy | ±1% of reading (for mg/L scale) |
| Resolution | 0.1 mg/L (0–99.9 mg/L range) |
| Optical Path Length | 20 mm quartz cell |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Detector Type | Thermoelectric sensor |
| Data Interface | RS-232C, parallel printer port |
| Display | Backlit LCD with timestamping |