Online Reaction Analysis System
Filter
Showing 31–57 of 57 results
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ALT-1-PH |
| Pricing | Upon Request |
| Detection Principle | Potentiometric and Colorimetric Acid-Base Titration |
| Analysis Frequency | Once per 20 minutes |
| RSD | ≤1% (Potentiometric), ≤2% (Colorimetric) |
| Detection Range | 0.01–10 mol/L H⁺ |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Alarm Indicators | Dual-color LED for liquid level, data out-of-spec, reagent expiry, and system fault |
| Output Interfaces | Modbus TCP, RS-232/485, CAN, 4–20 mA analog |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH (non-condensing at 10 °C) |
| Wetted Materials | PTFE/FEP |
| Enclosure Rating | IP55 / IP65 (when door is closed and locked) |
| Dimensions (W×D×H) | 500 × 400 × 1600 mm |
| Power Supply | 100–220 V AC, 50–60 Hz, 200 W |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ALT-1-TZ |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | ALT-EDTA |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ALT-ORP |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT-PCB Online Copper Ion Analyzer |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ALT-PCB Online Sodium Persulfate Concentration Analyzer (for NPS, SPS, and APS) |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT-PCB |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT-PH Series |
| Pricing | Upon Request |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH (non-condensing), 10 °C minimum |
| Resolution | Potentiometric input: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric absorbance | 0.003 Abs (0–1 Abs) |
| Enclosure Rating | IP55/IP65 (achieved when door is closed and latched) |
| Titration Precision | ±1 µL volumetric delivery accuracy (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ALT-SED |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | HG-CuOnline |
| Pricing | Upon Request |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Operating Environment | ≤90% RH, 10 °C (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | ±0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Ingress Protection | IP55/IP65 (when door is closed and latched) |
| Titration Accuracy | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Online Karl Fischer Coulometric Moisture Analyzer |
| Pricing | Upon Request |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Sample Pressure | Atmospheric (or pressurized via optional pressure regulator) |
| Sample Line | Φ1/8″ or 6–10 mm PFA tubing |
| Sample Flow Path | Standard single-channel |
| Sample Temperature Range | 5–60 °C |
| Reagent-Wetted Materials | Corrosion- and oxidation-resistant high-performance polymers |
| Nitrogen Purge | Optional micro-positive-pressure inert atmosphere |
| Enclosure Rating | IP55/IP65 (customizable) |
| Explosion Protection | Non-explosion-proof standard |
| Analyte Phase | Liquid samples only |
| Measurement Principle | Coulometric Karl Fischer titration |
| Auxiliary Functions | Multi-stream sampling module (1:N), reagent dosing control, anti-crystallization heating jacket |
| Detection Module | Potentiometric endpoint detection |
| Output Interfaces | Modbus TCP, RS-232/RS-485, CAN bus |
| Status Indicators | Dual-color LED (operational / alarm) |
| Measurement Range | Absolute water mass: 3 µg – 199 mg |
| Water concentration | 1 ppm – 100% w/w |
| Resolution | 0.01 µg (water mass) |
| Electrolysis Current | 0–400 mA |
| Max. Electrolysis Rate | 2241 µg/min |
| User Access Control | Three-tier permission system compliant with GMP/GLP requirements |
| Audit Trail | Full timestamped event logging including method changes, calibration actions, operator logins, and raw measurement data |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (PRC) |
| Model | GC-9560-HTP |
| Pricing | Upon Request |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | HK-5100 |
| Pricing | Upon Request |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-5200 |
| Quotation | Upon Request |
| Cooling Capacity | 4.5 kW |
| Refrigeration Power | 5 HP |
| Electrical Power Input | 6 kW |
| Circulating Pump Power | 1.5 kW |
| Max. Sample Inlet Temp | ≤40 °C |
| Outlet Temp Control | (25 ±1) °C |
| Total Sample Flow Rate | 1500 mL/min |
| Sample Points | 1–20 |
| Cooling Water Requirement | P ≤ 0.2 MPa, Q ≤ 6 t/h |
| Circulation Flow Rate | 12 L/h |
| Temperature Stabilization Time | ≤3 min for 0.35 ton coolant |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-5500 |
| Pricing | Upon Request |
| Heat Exchanger Area | 2 × 15–2 × 30 m² |
| Deionized Water Tank Volume | 2 m³ |
| Pump Configuration | Dual (1 active + 1 standby), H-(30–65)-30-2002, 2 × (5.5–7.5) kW |
| DI Water Flow Rate | 10–40 t/h |
| DI Water Outlet Temperature | ≤33 °C |
| DI Water Outlet Pressure | 0.2–0.6 MPa |
| Industrial Cooling Water Inlet Flow | 15–60 t/h |
| Industrial Water Inlet Temp | ≤33 °C |
| Industrial Water Inlet Pressure | 0.2–0.6 MPa |
| Power Supply | 380 VAC, 50 Hz |
| Dimensions (L×W×H) | 3200 × 2000 × 2300 mm |
| Weight | 3.2 t |
| Construction Material | AISI 304 stainless steel for all wetted parts |
| Heat Exchanger Type | Weld-free gasketed plate heat exchanger |
| Control Features | Low/high level alarms, dry-run protection, auto-refill solenoid valve, dual-pump redundancy |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Thermo Fisher specifications) |
| Model | Invitrogen™ EVOS™ S1000 |
| Pricing | Available upon Request |
| Brand | KPM PSC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Guardian HD |
| Pricing | Upon Request |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MAY-2001HPO |
| Price | USD 4,050 (FOB Guangdong) |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Ra300-R4 |
| Origin | Guangdong, China |
| Concentration Range | 10 ppm – 99.9% |
| Measurement Temperature | −20 °C to 135 °C |
| Concentration Accuracy | ±10 ppm to ±0.1% (dependent on matrix and calibration) |
| Resolution | 0.01% |
| Sensor Technology | Soft X-ray & Visible Spectroscopy |
| Pressure Rating | ≤1 MPa |
| Environmental Operating Temperature | −10 °C to 130 °C |
| Output Signals | TCP/IP, RS-485/232 (digital), 2-channel relay outputs (high/low limit & fault alarms) |
| Power Supply | 220 V AC, <0.2 A |
| Ingress Protection | IP67 (wetted parts) |
| Display Options | 4.3″ or 8″ embedded touchscreen controller |
| Temperature Compensation | Automatic |
| Channel Capacity | 1–6 configurable detection channels (customizable) |
| Brand | PSC |
|---|---|
| Origin | USA |
| Model | MCT 460, MCT 466-SF, MCT 469-SF |
| Cooling Options | Air-cooled and water-cooled |
| Detector | Thermoelectrically temperature-stabilized MCT (Mercury Cadmium Telluride) |
| Operating Ambient Temperature | Up to 80 °C with optional cooling kit |
| Compliance | Designed for industrial environments per IEC 60529 (IP65/IP66 enclosures available) |
| Communication Protocols | PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP, DeviceNet, OPC UA over Ethernet |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RTK MFC-12V/24V |
| Pricing | Upon Request |
| Channels | 12 or 24 |
| Voltage Range | 0–1 V |
| Voltage Resolution | 0.001 V |
| Brand | SIELINS |
|---|---|
| Model | XLZ-1090A |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Gas Channels | Up to 3 simultaneous analytes (e.g., CO, CO₂, CH₄, SO₂, NO + optional O₂) |
| Measurement Range (typ.) | CO: 0–2000 ppm |
| CO₂ | 0–1000 ppm |
| O₂ | 0–1% vol |
| Display | Color TFT LCD with capacitive touch interface |
| Output | 4–20 mA analog (isolated), 8 relay outputs (SPDT), RS232 (field-upgradable to RS485) |
| Response Time (T90) | ≤15 s (IR channels) |
| Stability | ±1% FS / 7 days |
| Repeatability | ±0.5% FS |
| Linearity Error | ±1% FS |
| Temp. Drift | ±1% FS (5–45 °C) |
| Pressure Compensation | Yes |
| Enclosure | 19″ (483 mm) rack-mount chassis |
| Certifications | Non-explosive (non-ATEX/IECEx) |
| Operating Ambient | 5–45 °C |
| Interference Rejection | ±1% FS under cross-gas interference |
| Brand | SIELINS |
|---|---|
| Model | XLZ-800 |
| Application | Cement Kiln Electrostatic Precipitator & Coal Mill Safety Monitoring |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–1000 ppm CO (configurable) |
| Accuracy | ±2% FS |
| Response Time (T90) | <30 s |
| Output Signals | 4–20 mA, Relay Alarms (SPDT), Digital Modbus RTU |
| Environmental Operating Range | −10 to +50 °C, ≤90% RH (non-condensing) |
| Enclosure Rating | IP65 |
| Compliance | GB/T 18204.2–2014, ISO 12039, IEC 61508 SIL 2 capable |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | XLZ-900 |
| Output | 4–20 mA analog signal per gas component |
| Alarm Output | Dry contact (NO/NC) for concentration threshold violation |
| Communication Interface | RS-485 (Modbus RTU) |
| Application Domain | Microbial fermentation off-gas monitoring (O₂, CO₂, exhaust airflow) |
| Compliance Context | Designed for integration into GMP-compliant biomanufacturing environments with audit-ready data logging capability |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | SIELINS-904 |
| Power Supply | AC 220 V ±10%, 50 Hz ±1% |
| Total Power Consumption | 2000 VA |
| Probe Power | 800 VA |
| � | �热管线供电: 1500 VA |
| Compressed Air Requirement | 0.6 MPa, oil-free & dry |
| Ambient Temperature Range | −10–50 °C |
| Relative Humidity | <80% RH |
| Output Signal | Isolated 4–20 mA DC |
| Alarm Output | Dry contact (NO/NC configurable) |
| Sample Gas | Wet, dusty process gas containing CO |
| Primary Analyte | Carbon Monoxide (CO) |
| Compliance | Designed for industrial process monitoring per IEC 61511 functional safety principles (non-SIL certified), compatible with DCS/PLC integration under ISO 50001 energy management contexts |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TONSOER® Explorer I Platform |
| Pricing | Upon Request |
| Measurement Scope | Designed for spatially distributed, homogeneous process monitoring applications — e.g., Cu²⁺ and H₂SO₄ concentration monitoring in PCB manufacturing lines |
| Detection Principles | Potentiometric titration (acid-base, complexometric, precipitation, redox), photometric detection, and photometric titration |
| Sample Throughput | Base configuration (4 modules): ~10 min for 4 analytes |
| Standard configuration (8 modules) | ~10 min for 8 analytes |
| System Footprint | 3550 mm (W) × 650 mm (D) × 1850 mm (H) |
| Sample Handling Unit | 1250 mm (W) × 650 mm (D) × 1000 mm (H) |
| Analytical Unit | 620 mm (W) × 650 mm (D) × 1850 mm (H) |
| Power Supply | 198–242 V AC, 50 Hz ± 0.5 Hz, 2000 W |
| Operating Environment | 15–30 °C, RH 65 % ± 20 % (max daily temperature fluctuation ≤5 °C) |
| Control Interface | Windows-based desktop PC with ≥23-inch display |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Amine Concentration and H₂S/CO₂ Acid Gas Online Analyzer |
| Pricing | Available Upon Request |