Other Common Laboratory Equipment
Filter
Showing 571–600 of 1883 results
| Brand | HCP (Longcai Technology) |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-sourced) |
| Model | PPLN Waveguide Chips |
| Pricing | Upon Request |
| Brand | HCP (Longcai Technology) |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (Taiwan-made) |
| Model | 1x0 High Power SHG Mixer |
| Pricing | Upon Request |
| Input | Fiber-coupled (1064 nm, up to 5 W CW) |
| Output | Free-space 532 nm (green), single-channel |
| Conversion Efficiency | >65% (typical at 5 W input) |
| Beam Quality | M² < 1.2 |
| Polarization | Linear, vertical |
| Cooling | Conductive (fanless, thermally stabilized baseplate) |
| Dimensions | 85 × 55 × 32 mm |
| Weight | 280 g |
| Operating Temperature | 15–35 °C |
| Storage Temperature | –10–60 °C |
| Humidity | <80% RH (non-condensing) |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | HD-21 |
| Dimensions (W×D×H) | 127 × 38 × 52 mm |
| Weight | 105 g |
| Material | Corrosion-resistant anodized aluminum alloy |
| Compatibility | Designed for simultaneous mounting of two standard single-channel pipettes onto a three-axis hydraulic micromanipulator (e.g., MO-10, MN-151 series) |
| Alternate Use | Direct replacement for UT-10 universal joint |
| Included Tool | Hex key (2.0 mm) |
| Origin | Liaoning, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Tri-Target High-Vacuum |
| Pricing | Upon Request |
| Ultimate Vacuum | ≤5.0×10⁻⁵ Pa (after bake-out) |
| Leak Rate | <2.0×10⁻⁸ Pa·L/s |
| Pump-Down Time to 6.0×10⁻⁴ Pa | ≤40 min (after brief air exposure + dry N₂ purge) |
| Chamber Dimensions | Ø300 × 350 mm |
| Target Diameter | Ø50 mm (3 targets |
| Substrate Heating Range | RT–600 °C ±1 °C |
| Substrate Rotation Speed | ≤30 rpm |
| Target-to-Substrate Distance | Adjustable from 90–110 mm |
| Base Pressure Recovery (12 h idle) | ≤5 Pa |
| Brand | Hengyu |
|---|---|
| Origin | Tianjin, China |
| Model | HY-726-1 |
| Clamp Width | 45 mm |
| Clamp Spacing | 35 mm |
| Display | 6-digit LCD |
| Dimensions (L×W×H) | 45×38×50 cm |
| Weight | 60 kg |
| Power Supply | AC 220 V, 50 Hz, 500 W |
| Operating Environment | 20 °C, 65 % RH |
| Compliance | GB/T 8948–2008, GB/T 8949–2008, JIS L 1096, JIS K 6404–6, JASO M 403, GMW 3217 |
| Brand | Hengyu |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | HY-7520-1 |
| Pricing | Upon Request |
| Standards Compliance | EN 13595-2, EN 14120, GB/T 24278–2019 |
| Abrasive Belt Speed | 2–8 m/s |
| Abrasion Head Diameter | 40 mm |
| Effective Abraded Area | 1963 mm² |
| Drop Height | 50 ± 5 mm |
| Applied Load | 49 N (via calibrated weights, excluding pneumatic lift mechanism mass) |
| Standard Reference Fabric | Provided cotton duck cloth (EN-compliant) |
| Abrasive Belts | P60 and P120 grit aluminum oxide belts |
| Brand | Hengyu |
|---|---|
| Model | QB/T 2714 |
| Standard Compliance | QB/T 2714–2005, ISO 5402, ISO 20344, ASTM D6182, BS 3144, JIS K 6546, GB/T 20991–2007, FZ/T 73028, SATRA TM55, SLP 14, IUP 20, Adidas GE-24 |
| Test Stations | 12 |
| Drive Motor | Imported low-noise AC motor |
| Base Construction | Monolithic machined aluminum base (no welding) |
| Dimensions (L×W×H) | 63 × 45 × 40 cm |
| Weight | 60 kg |
| Power Supply | AC 220 V, 50 Hz, 300 W |
| Operating Environment | 23 °C ± 2 °C, 50 % RH ± 5 % RH |
| Footprint | Benchtop installation |
| Brand | HENGYU |
|---|---|
| Model | RF 1106-1 |
| Power Supply | AC 220 V, 50 Hz, 1000 W |
| Operating Environment | 10–35 °C, 10–80 % RH |
| Gas Source | Butane |
| Display | 7-inch color touchscreen |
| Ventilation System | Forced-exhaust fan, adjustable airflow fan, and internal recirculation fan |
| Ignition Source | Bunsen burner |
| Compliance | ISO 105-G02, GB/T 11039.2, AATCC 23 |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HXG-T225 |
| Price Range | USD 14,000 – 42,500 |
| Microwave Power Output | 0–4800 W (continuously adjustable) |
| Operating Frequency | 2450 MHz |
| Cavity Volume | 225 L |
| Cavity Material | Seamless 304 Stainless Steel Welded Construction |
| Internal Configuration | 1–4 Removable Perforated Stainless Steel Trays |
| Temperature Measurement | Dual-mode — Thermocouple (0–1200 °C) + Infrared Pyrometer (0–500 °C) |
| Humidity Sensing | Integrated Capacitive RH Sensor |
| Airflow System | Forced Convection with Adjustable Flow Rate |
| Control System | PLC-based Intelligent Controller with 7″ Color Touchscreen |
| Data Management | Multi-step Program Storage, Real-time Temp/RH Curve Logging, USB Data Export |
| Safety Compliance | Microwave Leakage <5 mW/cm² (GB 10436-2008), Interlocked Door Switch, Overtemperature & Overpressure Protection, Explosion-Resistant Sealed Cavity, Corrosion-Resistant Enclosure |
| Dimensions (W×D×H) | 1500 × 750 × 1640 mm |
| Continuous Duty Rating | 24/7 Industrial Operation |
| Key | Brand: HEXING BIOCHEMICAL |
|---|---|
| Model | HXH-G3A / HXH-G6B / HXH-G9B |
| Microwave Power | 0–4.8 kW / 0–9.6 kW / 0–14.4 kW (2450 MHz, continuously adjustable) |
| Cavity Volume | 65 L (single-tube) / 2×65 L (dual-tube) / 3×65 L (triple-tube) |
| Sample Capacity | 3×2 L crucibles (single-environment) / 6×2 L crucibles (dual-environment) / 9×2 L crucibles (tri-environment) |
| Temperature Range | 0–1200 °C (thermocouple feedback) |
| Safety Compliance | GB 4706.21-2008, GB 5959.6-2008 |
| Operating Atmosphere | Air or user-defined gas inlet with adjustable positive/negative pressure control |
| Exhaust | Integrated Venturi-based negative-pressure exhaust system |
| Control System | PLC-based intelligent controller with color touchscreen, multi-step programmable protocols, real-time temperature/time curve logging, USB data export |
| Surface Temp | <50 °C |
| Microwave Leakage | <5 mW/cm² (per national standard) |
| Key | Brand: HEXING BIOCHEMICAL |
|---|---|
| Model | HXH-L10 |
| Origin | Shandong, China |
| Power Range | 0–3.2 kW (adjustable) |
| Frequency | 2450 MHz |
| Cavity Volume | 56 L |
| Crucible Capacity | 10 L (quartz, standard |
| Temperature Range | 0–1200 °C (thermocouple-sensed) |
| Cavity Construction | Fully sealed, stainless steel welded monoblock with micro-positive pressure design |
| Insulation | Integrated high-efficiency thermal insulation |
| Gas Atmosphere | Adjustable air inlet |
| Exhaust | Venturi-based negative-pressure exhaust system |
| Safety Compliance | GB 4706.21–2008, GB 5959.6–2008 |
| Regulatory Alignment | GB/T 14883.1–2016, GB 5749–2006, GB 16145–1995 |
| Dimensions (W×D×H) | 975 × 750 × 1680 mm |
| Control System | PLC with color touchscreen interface, multi-stage programmable protocols, real-time temperature/time curve logging, USB data export |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXH-T25 / HXH-T100 |
| Microwave Power | 0–3.2 kW (HXH-T25) / 0–10 kW (HXH-T100) |
| Frequency | 2450 MHz |
| Cavity Volume | 25–26 L |
| Max Operating Temperature | 900 °C (short-term up to 1200 °C) |
| Temperature Sensor | K-type thermocouple |
| Chamber Material | Industrial-grade stainless steel welded monoblock cavity with internal ceramic fiber insulation (optional quartz-lined cavity) |
| Airflow Control | Adjustable inlet + programmable negative-pressure exhaust system |
| Sample Capacity | Dual-layer 2 × 2 L ceramic crucibles (T100) or up to 84 × 15 mL / 40 × 30 mL / 12 × 150 mL crucibles (T25) |
| Control System | PLC-based touchscreen interface with real-time curve logging (time/temperature/power), multi-step program storage, and USB data export |
| Safety Compliance | Interlocked door, surface temperature <50 °C, microwave leakage <5 mW/cm² (GB 10436), over-temperature & over-pressure protection |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HXJ-L10A |
| Power Supply | 220 V ±10 V, 50 Hz |
| Operating Temperature Range | 0–800 °C |
| Maximum Temperature | 1200 °C |
| Temperature Measurement Accuracy | ±2 °C |
| Gas Flow Rate | 1000 Nm³/h |
| Odor Removal Efficiency | 98.7% |
| H₂S Inlet Concentration | ≤10 ppm |
| Ambient Humidity Tolerance | ≤80% RH |
| Inlet Pollutant Concentration Range | 0–100 mg/m³ |
| Stage 1 Filtration | Refrigerated Condensation-Based Tar Collector |
| Stage 2 Filtration | Electrostatic Tar & Odor Scrubber |
| Overall Dimensions (W×D×H) | 800 × 500 × 500 mm |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXO-T50 |
| Power Supply | 220 V ±10 V, 50 Hz ±1 Hz |
| Total Power | 3000 W |
| Temperature Range | 0–1200 °C |
| Control System | PLC-based touchscreen interface with dual-zone 20-segment programmable ramp/soak profiles |
| Heating Tube Dimensions | Ø50 mm × 900 mm |
| Sample Holder | Ceramic boat |
| Temperature Sensing | Type K thermocouples, accuracy ±1 °C |
| Oxidation Configuration | Multi-gas inlet with independent mass flow control (O₂, air, CO₂/O₂ mix), dual-stage condensation for H₂O(³H) capture, tandem alkaline absorption traps for CO₂(¹⁴C) recovery |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MKX-M/R Series |
| Price Range | USD 7,000 – 14,000 |
| Microwave Power | 0–800 W (MKX-M1B), 0–1600 W (MKX-R2HB) |
| Frequency | 2450 MHz |
| Operating Temperature Range | 0–1000 °C (short-term up to 1200 °C) |
| Temperature Sensor | K-type thermocouple |
| Cavity Volume | 1.2 L (MKX-M1B), 5 L (MKX-R2HB) |
| Cavity Material | Industrial-grade stainless steel welded enclosure with internal ceramic fiber insulation (MKX-M1B) or quartz-lined high-purity chamber (MKX-R2HB) |
| Atmosphere Control | Adjustable inlet for air, O₂, N₂, or Ar |
| Control System | PLC-based intelligent controller with color touchscreen interface |
| Safety Compliance | Interlocked door switch, surface temperature <50 °C, microwave leakage <5 mW/cm² (GB 10436-2008) |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MKX-X1/X2 Series |
| Output Power | 0–800 W / 0–1800 W |
| Frequency | 2450 MHz |
| Cavity Volume | 20 L (MKX-X1) / 70 L (MKX-X2) |
| Temperature Range | 0–300 °C |
| Pressure Range | 0–3 MPa |
| Sample Capacity | 6 × 80 mL / 20 × 55 mL / 40 × 55 mL |
| Vessel Material | TFM (Perfluoroalkoxy alkane) |
| Vessel Sleeve Material | PEEK + GF (Glass-Filled Polyetheretherketone) |
| Cavity Construction | Industrial-grade stainless steel with multi-layer PFA coating |
| Temperature Sensing | Fiber-optic or infrared (single/dual point) |
| Pressure Monitoring | Real-time digital pressure transducer with overpressure alarm |
| Control System | PLC-based intelligent controller with color TFT touchscreen |
| Data Logging | Time-temperature-pressure-power dynamic curves, exportable via USB |
| Safety Compliance | <5 mW/cm² microwave leakage (GB 10436-2008), interlocked door, explosion-resistant vessel design, corrosion-resistant exhaust system, CE-marked electrical architecture |
| Key | Brand: HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | MSX-G2A |
| Microwave Power | 0–1600 W (continuously adjustable, 2450 MHz) |
| Cavity Volume | 33 L |
| Cavity Material | Industrial-grade 304 stainless steel, fully welded, interior coated with multi-layer PTFE |
| Temperature Range | 0–300 °C (steam/microwave-controlled), optional thermocouple up to 1200 °C |
| UV System | Dual-sided UVC irradiation (254 nm) |
| Steam System | Sealed, recirculating high-temperature steam generator with pressure regulation |
| Air Management | Independent ducted airflow with motorized gate valves for humidification, steaming, drying, and dehumidification modes |
| Control System | PLC-based intelligent controller with 7-inch color touchscreen, multi-stage programmable protocols, real-time temperature/time curve display, data export (USB) |
| Safety Compliance | Interlocked door switch, surface temperature <50 °C, microwave leakage <5 mW/cm² (GB 4706.21–2008), explosion-proof & corrosion-resistant design |
| Dimensions (W×D×H) | 520 × 550 × 618 mm |
| Configuration Options | MSX-G2A1 (Sterilization-Optimized), MSX-G2A2 (Drying-Optimized) |
| Sample Capacity | 1–4 layer stackable trays (metal or PTFE-coated polymer) |
| Regulatory Context | Designed for GLP-compliant sample prep environments |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Origin Classification | Domestic |
| Model Options | 250 mL, 500 mL, 1000 mL |
| Pricing | Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Origin Category | Domestic |
| Model | Custom |
| Pricing | Upon Request |
| Brand | HHitech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HT-1 |
| Pricing | Available Upon Request |
| Brand | auniontech |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | HiCAM Fluo |
| Max Frame Rate | 4000 fps |
| Sensor Resolution | 1280 × 1024 pixels |
| Minimum Exposure Time | 2 µs |
| Gating Pulse Width (FWHM) | 40 ns |
| Gating Repetition Rate | Up to 100 kHz |
| Image Intensifier | Gen III, fiber-optically coupled |
| Cooling | Peltier-cooled intensifier (−30 °C typical operating temperature) |
| Interface | CoaXPress v2.0 (quad-link) |
| Pixel Size | 6.6 × 6.6 µm |
| Software Support | CoaXPress SDK, LabVIEW drivers, optional real-time FPGA-based frame grabber integration |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | OPO |
| Price | Upon Request |
| Tuning Range | Signal 414–709 nm, Idler 710–2200 nm, SHG 220–350 nm |
| Pulse Width | <1–2 ns (FWHM) |
| Peak Pulse Energy | >12 mJ (Signal), up to 60 mJ @ 355 nm pump with 150 mJ input |
| Repetition Rate | 50 Hz |
| Linewidth | 0.15 nm @ 500 nm |
| Conversion Efficiency | Up to 40% (Signal + Idler) |
| Pump Compatibility | Nd:YAG (266/355/532/1064 nm), including third-harmonic 355 nm |
| Nonlinear Crystal | BBO (broadband, pre-screened & certified) |
| Control Interface | PC-based automated software with real-time parameter logging and remote operation capability |
| Enclosure | Hermetically sealed, compact OEM-grade housing |
| Lifetime | >1 × 10⁶ shots (BBO crystal & optics qualified per MIL-STD-883 optical aging protocols) |
| Key | Origin: Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HT-CRE-30 |
| Quotation | Upon Request |
| Max Test Load | 5–30 kN |
| Temp Range (Standard) | 300–900 °C |
| Max Temp | 1000 °C |
| Optional | High-Temp Creep Extensometer |
| Key | Origin: Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | High-Speed Impact Testing Machine (Hydraulic Servo Type) |
| Pricing | Upon Request |
| Max Impact Energy | 5250 J |
| Rated Specimen Absorption Energy | 4500 J |
| Rated Specimen Reaction Force | ±400 kN |
| Loading Velocity Range | ±2 to ±10 m/s |
| Brand | ALLSHENG (Hangzhou Aosheng) |
|---|---|
| Substrate | Fluorinated Release Liner + Transparent PS Adhesive Layer |
| Total Thickness | 95 µm |
| Width | 80 mm |
| Length | 51 m |
| Part Number | AS-F16R |
| Origin | Zhejiang, China |
| Brand | HISTO (Hengdao Manufacturing) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Histo-AK |
| Price | USD 850 (FOB Zhejiang) |
| Dimensions | 30 cm × 20 cm × 10 cm |
| Power Consumption | 200 W |
| Operating Voltage | 220 V, 50 Hz |
| Temperature Range | 0–100 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Capacity | ≥49 standard glass slides (76 mm × 26 mm) |
| Display | Digital LED temperature readout with intuitive keypad interface |
| IP Rating | IPX5-rated sealed enclosure for full-unit rinsing |
| Brand | HISTO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Histo-xiu Wax Trimming Station |
| Price | USD 850 (FOB Zhejiang) |
| Dimensions | 15 × 11 × 15 cm (W × D × H) |
| Power | 100 W |
| Operating Voltage | 220 V, 50 Hz |
| Temperature Range | 0–100 °C |
| Temperature Control Accuracy | ±1 °C |
| Brand | Hitec Zang |
|---|---|
| Origin | Germany |
| Model | HiClave |
| Pressure Rating | Up to 300 bar |
| Temperature Range | Up to 300 °C |
| Reactor Volume Options | 10–250 mL |
| Construction Materials | SS 1.4571 (316 Ti) or Hastelloy C-4 |
| Sealing | All-metal face seal with threaded closure |
| Stirring Options | Magnetic stirring (10–20 mL), top-driven magnetic-coupled mechanical stirring (50–250 mL, torque up to 50 N·cm) |
| Gas/Liquid Inlets/Outlets | Up to 7 ports |
| Integrated Hydration Module | Automated inert gas purging, leak testing, and pressure hold verification |
| Real-time Gas Consumption Monitoring | Mass-flow-based kinetic measurement with timestamped data logging |
| Brand | HJ Purification |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | AAS-700As |
| Price | USD 1,650 (FOB Shanghai) |
| Filter Efficiency | ≥99.97% @ ≥0.5 µm |
| Interlock-Compatible Door Control | Dual-Interlocked |
| Air Shower Duration | 0–60 s (adjustable in 1-s increments) |
| Nozzle Quantity & Diameter | 16 × Φ30 mm stainless steel nozzles |
| Exit Air Velocity | 15–20 m/s (measured at nozzle exit plane) |
| Power Supply | AC 220 V ±10%, 50 Hz, Single Phase |
| Total Power Consumption | ≤1.0 kW |
| Unit Weight | ~300 kg |
| HEPA Filter Specification | 600 × 600 × 120 mm, 8 units |
| Pre-Filter Specification | 850 × 580 × 10 mm, 8 units |
| Chamber Wall Material | Polyphenylsulfone-reinforced color-coated steel sandwich panel (core density: 14 kg/m³) |
| Structural Frame | 304 Stainless Steel Reinforced Chassis |