Other Common Laboratory Equipment
Filter
Showing 541–570 of 1883 results
| Brand | Gerhardt (C. Gerhardt) |
|---|---|
| Origin | Germany |
| Model | Dumatherm DT N Pro |
| Configuration | Pneumatic autosampler (64-position standard |
| Detection Principle | High-temperature combustion followed by thermal conductivity detection (TCD) and/or chemiluminescence detection (CLD) of nitrogen oxides after catalytic reduction |
| Sample Forms | Solid, liquid, semi-solid (paste) |
| Typical Analysis Time | ≤180 s per sample |
| Nitrogen Range | Up to 50 mg N per analysis |
| RSD | <0.5% (absolute, for 200 mg EDTA reference) |
| Carrier Gas Options | Helium (optimal sensitivity) or Argon (cost-optimized) |
| Oxygen Delivery | Software-controlled precise dosing |
| Compliance | AOAC, DIN EN ISO, USP, and national food/feed/environmental standards |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | KT / KT-L |
| Sample Capacity | 8/20/40 positions |
| Digestion Tube Sizes | 100 mL, 250 mL, 400 mL |
| Temperature Control Accuracy | ±0.5% of setpoint |
| Programmable Methods | 99 methods, up to 40 temperature ramps per method |
| Predefined Methods | 30 standard protocols |
| Heating Rate | Adjustable |
| Safety Features | Overheat protection, acid drip tray, audible/visual alarms, automatic fume extraction activation, user-configurable safety cutoff temperature |
| Compliance | ISO/IEC 17025, GLP, FDA 21 CFR Part 11 (audit trail & user access control), DIN EN ISO 5983, AOAC 984.13, EPA 350.1, ASTM D5142, EU Regulation (EC) No 152/2009, APHA 4500-Norg, Ph. Eur. 2.5.33 (Method 7, Step A) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | VS |
| Application | Laboratory Acid Fume Treatment |
| Principle | Dilution, Chemical Neutralization, Absorption |
| Flow Rate | 120 L/min |
| Compliance | Meets German TRGS 554 and EU Directive 2010/32/EU for laboratory fume control |
| Power Consumption | 100 W |
| Noise Level | <52 dB(A) |
| Maintenance | Tool-free access via top-hinged door |
| Cooling | Integrated condensate trap |
| Filtration | Dual-stage — chemical scrubbing + optional solid-phase adsorption cartridge |
| Compatibility | Fully interoperable with Gerhardt KJELDATHERM, TURBOTHERM, KI digestion units and SMA series reflux digesters |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 300 |
| Water Consumption | ~3 L/min |
| Distillation Time | ~3 min 30 s (standard Kjeldahl method) |
| Power | 2200 W |
| Frequency | 50/60 Hz |
| Weight | 34 kg |
| Dimensions | 527 × 390 × 697 mm |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Supply Voltage | 230 V AC |
| Nitrogen Recovery Rate | >99.5% |
| Brand | Gerhardt (C. Gerhardt) |
|---|---|
| Origin | Germany |
| Model | Vapodest 450 |
| Configuration | Standalone Steam Distillation Unit with Optional External Titrator Integration |
| Compliance | Designed for ASTM D1193, ISO 8968-1, ISO 5983-1, AOAC 981.10, USP <467>, and EN ISO 1871 |
| [Origin | Germany |
|---|---|
| Model | Zennium Pro |
| Potentiostat/Galvanostat Bandwidth | 10 MHz |
| ADC Resolution | 32 bit |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Frequency Accuracy | ±0.0025% |
| Frequency Resolution | 10,000 steps/decade |
| AC Amplitude Range | 0–6 V |
| Impedance Measurement Range | 1 mΩ – 10 GΩ (±2%), 100 mΩ – 10 MΩ (±0.2% for POT mode), 10 µΩ – 1 GΩ (±2% for GAL mode), 100 mΩ – 100 GΩ (±2% with HIZ probe) |
| Max Current Output | ±3 A |
| Applied Potential Range | ±15 V |
| Cell Voltage Range | ±28 V |
| Voltage Resolution | 3 nV |
| Current Resolution | ±5 aA |
| Small-Signal Rise Time | 150 ns – 200 µs (5-step auto-ranging) |
| Input Impedance | >10 TΩ |
| Grounding Modes | Switchable floating/grounded configuration |
| IR Compensation | Real-time automatic iR compensation |
| Software Platform | Thales XT with Zahner SIM, Z-HIT, EIS time-series analysis, equivalent circuit fitting, GITT/PITT, RDE/RRDE, battery cycling, electrochemical noise, and photoelectrochemical modules] |
| Brand | GLTLab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TR-1C |
| Price | USD 720 (FOB Guangdong) |
| Roller Length Custom Range | 20–100 cm |
| Roller Diameter Custom Range | 2–10 cm |
| Speed Range | 1–1500 rpm |
| Load Capacity per Roller | 10–100 kg |
| Timer Range | 1 s – 200 h |
| Display | Digital LED Control Panel |
| Roller Spacing | 15 cm |
| Control System | Microprocessor-Based Numerical Control (NC) |
| Key | Origin: Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | GMK-508-1L / GMK-508-3L / SC60 |
| Measurement Range | 0.1–100% H₂O |
| Accuracy | ±0.2% |
| Sample Capacity | 5 g (GMK-508-1L), 50 g (GMK-508-3L), 10–100 g (SC60) |
| Readability | 0.001 g |
| Heating Source | Halogen Lamp (200 W × 1 for GMK-508-1L |
| Display | LCD with real-time moisture %, initial/final weight & temperature |
| Interface | RS232 for printer/data export |
| Pan Diameter | Φ80 mm (GMK-508-1L), Φ170 mm (GMK-508-3L), Φ110 mm (SC60) |
| Dimensions | 260×130×370 mm (GMK-508-1L), 410×245×425 mm (GMK-508-3L), 350×200×260 mm (SC60) |
| Weight | 4.5 kg (GMK-508-1L), 10 kg (GMK-508-3L), 7.5 kg (SC60) |
| Brand | Gongyi Yuhua Instrument |
|---|---|
| Origin | Henan, China |
| Model | YDF-1L, YDF-2L, YDF-3L, YDF-5L, YDF-10L–YDF-100L |
| Vessel Material | GG-17 Borosilicate Glass (3.3) |
| Max Vacuum | −0.098 MPa (−98 kPa) |
| Stirring Speed Range | 0–800 rpm (digital display) |
| Motor Power | 40 W |
| Operating Voltage | 220 V AC |
| Sealing | PTFE Components |
| Temperature Control | Compatible with External Oil/Water Bath Circulators or Chilled Circulation Units |
| Discharge | Bottom-mounted Full-Seal Drain Valve (for ≥10 L models) |
| Compliance | Designed for Lab-Scale Synthesis, Extraction, and Distillation under Ambient and Reduced Pressure |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | Mobile LAB |
| Vehicle Integration | Custom Chassis Options |
| Power Supply | Dual-mode (110/240 V AC + Rechargeable Battery) |
| Environmental Control | Independent HVAC with 20 air changes/hour |
| Safety | Seismic-grade instrument mounting, anti-slip flooring, fire extinguisher, dedicated waste/fresh water tanks |
| Data Infrastructure | Integrated LAN, optional GPS, printer, and PC |
| Compliance | Designed for ASTM D975, D3948, D4865, EN 590, ISO 4214, and USP <1058> analytical instrument qualification frameworks |
| Brand | KJ GROUP (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-1100X-S |
| Pricing | Upon Request |
| Power | AC 220 V, 50 Hz |
| Max. Temperature | 1100 °C (<2 h) |
| Operating Temperature | ≤1000 °C |
| Heating Zone Length | 300 mm |
| Uniform Temperature Zone | 120 mm |
| Ramp Rate | ≤20 °C/min |
| Temperature Control Accuracy | ±1 °C |
| Thermocouple Type | K-type |
| Heating Element | Mo-doped Fe-Cr-Al alloy wire with ZrO₂ coating |
| Tube Dimensions | Φ25 mm × 600 mm & Φ50 mm × 600 mm (quartz) |
| Vacuum Capability | 10⁻² torr (with mechanical pump) |
| Furnace Dimensions | 400 mm × 300 mm × 550 mm |
| Net Weight | 19 kg |
| Brand | KJ GROUP / Shenyang Kejing |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | GSL-1400X-III |
| Pricing | Upon Request |
| Power Supply | AC 220 V, 50/60 Hz, 4 kW |
| Maximum Temperature | 1400 °C (continuous at 1300 °C) |
| Heating Element | Silicon Carbide Rods |
| Thermocouple Type | S-type Platinum-Rhodium |
| Uniform Temperature Zone | 120 mm |
| Tube Dimensions | Φ60 × 1000 mm or Φ80 × 1000 mm (Al₂O₃) |
| Chamber Lining | High-Purity Alumina Fiber (Vacuum-Formed) |
| Control Accuracy | ±1 °C |
| Vacuum Compatibility | Yes (with optional high-vacuum system) |
| Atmosphere Capability | Inert, reducing, oxidizing, or vacuum |
| Certifications | CE-compliant |
| Overall Dimensions | 860 × 470 × 720 mm |
| Net Weight | 120 kg |
| Brand | KJ Group (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | GSL-QHRL-X |
| Pricing | Upon Request |
| Ultimate Vacuum | ≤6.67×10⁻⁵ Pa (after bake-out) |
| Leak Rate | ≤5.0×10⁻⁷ Pa·L/s |
| Pump-Down Time | ≤45 min to 6.6×10⁻⁴ Pa after N₂ purge |
| Operating Temperature Range | 100–2300 °C |
| Chamber Orientation | Vertical or Horizontal |
| Chamber Diameter | Ø200–Ø2000 mm (customizable) |
| Heating Zones | Single to Multi-Zone (1–3+ zones) |
| Heating Elements | W, Mo, Ta, Graphite (high-temp) |
| Insulation | Multi-layer metal radiation shield, graphite cylinder, carbon felt, or water-cooled jacket |
| Cooling System | Integrated closed-loop chiller (deionized water, ≤25 °C, 0.25–0.4 MPa, ≥12 L/min) |
| Atmosphere Control | High-purity N₂ or Ar (≥99.99%) via external cylinder with φ10 mm dual-ferrule fitting & regulator |
| Power Supply | AC 380 V, 50 Hz, ±6% tolerance, grounding resistance <2 Ω |
| Footprint | 2000 mm × 2000 mm, load capacity ≥1000 kg |
| Exhaust | Mandatory external ducted ventilation |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | GY-TBY-10 |
| Pricing | Available Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | DR900 |
| Wavelengths | 420, 520, 560, 610 nm |
| Absorbance Range | 0 to 2.0 AU |
| Preprogrammed Methods | 90 |
| Data Storage Capacity | 500 measurements with sample ID and user ID |
| Display | Backlit LCD |
| Connectivity | USB (CSV export, no software required) |
| Power | 4 × AA batteries (included) |
| IP Rating | IP67 (dust-tight and submersible up to 1 m for 30 min) |
| Dimensions | 22.9 cm × 5.1 cm × 2.5 cm (L × H × W) |
| Weight | 340 g |
| Brand | Hach |
|---|---|
| Model | MS9000 |
| Origin | Imported |
| Sample Parameters | Temperature, pH, Dissolved Oxygen (DO), Conductivity, Turbidity, Permanganate Index (CODMn), Ammonia-N, Total Phosphorus (TP), Total Nitrogen (TN) |
| Design | Integrated, All-in-One Station for Unmanned Operation |
| Compliance | Designed to support GLP/GMP-aligned data integrity workflows |
| Software Integration | Compatible with Hach EWAS (Environmental Water Analytics System) digital platform |
| Maintenance Interval | Up to 7 days in high-fouling environments |
| Pre-treatment | Integrated mechanical filtration and automatic cleaning system |
| Data Output | Real-time streaming, historical trend export (CSV/PDF), alarm-triggered notifications |
| Certifications | Meets requirements for ISO 5667-22, ASTM D1293, D888, D511, D5907, D6508, and USP <643> where applicable |
| Brand | Hach |
|---|---|
| Model | SDI-12 |
| Measurement Principle | ASTM D4189-95 (Constant Pressure Filtration) |
| Channel Configuration | Single-Channel (Configurable up to 4 Channels) |
| Calibration & Maintenance | Auto-calibration and auto-cleaning cycles |
| Compliance | ASTM D4189-95, ISO 15714:2016 (Water quality — Determination of silt density index), GLP/GMP-ready data logging |
| Application Environment | Industrial feed water monitoring for UF/RO systems, including high-salinity variants (seawater-grade option available) |
| Output Interface | 4–20 mA analog + Modbus RTU/TCP |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | IP65 |
| Brand | Hailong |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | TD-2000 |
| Primary Desorption Temp Range | 40–380 °C, ±1 °C |
| Valve Heating Range | 40–240 °C, ±1 °C |
| Transfer Line Temp Range | 40–220 °C, ±1 °C |
| Cryo-Focusing Trap Temp Range | −35 to 400 °C |
| Flash Desorption Ramp Rate | >3000 °C/min |
| Peak Width (FWHM) | <3 s |
| Sample Tube ID | ≤6.5 mm |
| Primary Desorption Time | 0–60 min |
| Injection Time | 0–10 min |
| Simulated Sampling Duration | 0–60 min |
| Simulated Sampling Flow Rate | 16–160 mL/min |
| RSD | ≤2.5% (benzene in 0.05 µg methanol standard) |
| Power Consumption | 500 W |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Valve Actuation | Motor-Driven 6-Port Rotary Valve |
| System Architecture | Integrated Benchtop Unit with Embedded Microcontroller and Full-Text LCD Interface |
| Brand | Hailong |
|---|---|
| Model | TD-380 |
| Thermal Desorption Temperature Range | Ambient to 380 °C |
| Valve Oven Temperature Range | Ambient to 150 °C |
| Transfer Line Temperature Range | Ambient to 150 °C |
| Desorption Time | 0–60 min |
| Bake-out (Conditioning) Time | 0–60 min |
| Sample Introduction Time | 0–10 min |
| Carrier Gas Control | High-precision pressure-regulated stainless steel pneumatic system |
| Construction | Passivated 316 SS tubing, PTFE-sealed high-temp valve manifold, silicone O-rings (low-volatility), de-activated inert transfer lines |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | L10060 |
| Pricing | Available Upon Request |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Yundata |
| Instrument Category | Biological Degradation Air Purification System |
| Suitable Area | ≤60 m² |
| Noise Level | 55 dB(A) |
| Air Velocity | 7.4 m/s |
| Dimensions (W×D×H) | 542.6 × 320 × 577.5 mm |
| Brand | HCP / Longcai Technology |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Model | 1x0 2W 532nm Mixer |
| Output Wavelength | 532 nm |
| Input | Fiber-Coupled Fundamental (1064 nm) |
| Output | Free-Space Green Beam |
| Power Output | 2 W |
| Configuration | Single-Channel, Plug-and-Play SHG Module |
| Mechanical Design | Compact, Rigid Aluminum Housing |
| Conversion Efficiency | High (Typical >40% @ 2 W IR input) |
| Beam Quality | TEM₀₀, M² < 1.1 |
| Polarization | Linear, >100:1 Extinction Ratio |
| Brand | HCP |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Distributor |
| Model | 1x0 THG Mixer |
| Output Wavelength | 355 nm |
| Input | Fiber-Coupled (1064 nm fundamental) |
| Output Power | ≥50 mW (at 355 nm, with 1064 nm input ≥150 mW) |
| Conversion Efficiency | >33% (typical) |
| Polarization | Linear, orthogonal to input |
| Beam Quality | M² < 1.2 |
| Dimensions | 85 × 55 × 35 mm |
| Operating Temperature | 15–30 °C |
| Cooling | Conduction-cooled, no active cooling required |
| Compliance | RoHS 2015/863/EU, CE Marked (EMC Directive 2014/30/EU) |
| Brand | HCP (Longcai Technology) |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (Taiwan-sourced) |
| Model | 1x1 532 nm Waveguide Mixer |
| Pricing | Upon Request |
| Brand | HCP (Longcai Technology) |
|---|---|
| Origin | Taiwan |
| Type | 1×1 Fiber-Coupled Tunable Mixer |
| Wavelength Range | Continuously Tunable Across C-band, L-band, or C+L-band |
| Configuration | Fiber-in/Fiber-out |
| Form Factor | All-Fiber Integrated Module |
| Compliance | RoHS-compliant, Telcordia GR-1221-CORE Qualified |
| Brand | HCP (Longcai Technology) |
|---|---|
| Origin | Taiwan |
| Model | PPLN |
| Crystal Type | Periodically Poled Lithium Niobate (LiNbO₃) |
| Poling Period Range | 4.5 µm – 35 µm |
| Transparency Range | 350 nm – 5000 nm |
| Damage Threshold | >1 GW/cm² (1064 nm, 10 ns, 10 Hz) |
| Curie Temperature | 1140 °C |
| Refractive Index (1064 nm) | nₑ ≈ 2.19, nₒ ≈ 2.28 |
| QPM Structure Options | Uniform, Multi-Period, Fan-Out (Continuous Tuning), Chirped, Cascaded |
| Coating Options | AR/HR coatings available from UV to MIR |
| Substrate Orientation | Z-cut or X-cut configurable |
| Standard Dimensions | 5 × 5 × 0.5 mm³, 10 × 10 × 0.5 mm³, 10 × 10 × 1.0 mm³ (customizable) |
| Brand | HCP (Longcai Technology) |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (Taiwan-sourced) |
| Model | PPLN Cavity Mixers |
| Pricing | Available Upon Request |