Petroleum Low Temperature Property Tester
Filter
Showing 1–30 of 64 results
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Callisto 100 |
| Temperature Range | –60 °C to +45 °C |
| Cooling Profile | Programmable stepwise or linear (6–100 °C/h) |
| Calibration | Automated calibration for sample/jacket temperature and vacuum |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 test results |
| User Programs | Up to 90 customizable methods |
| External Cooling Required | Yes (280 W at –20 °C) |
| Dimensions | 340 × 580 × 310 mm (W × D × H) |
| Weight | 14 kg |
| Power Supply | 100–240 V, 50/60 Hz, 290 VA |
| Interfaces | 4× USB, 1× RS232, 1× LAN, 1× VGA |
| Data Export | XLS, PDF via USB flash drive |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | A1121 |
| Price Range | USD 7,000 – 14,000 |
| Measurement Range | Ambient to –70 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Display | LCD Touchscreen |
| Printer | Thermal, 36-character Chinese/English output |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions (W×D×H) | 460 × 310 × 480 mm |
| Weight | 21.3 kg |
| Brand | Ducom |
|---|---|
| Model | CPP |
| Origin | USA |
| Type | Integrated Dual-Function Petroleum Low-Temperature Property Analyzer |
| Temperature Range | –80 °C to +80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C (PT100 Class A) |
| Cooling System | Single-stage (to –40 °C) or Dual-stage (to –80 °C), CFC-free motor-compressor |
| Detection Methods | Cloud Point — coaxial infrared optical pulse detection |
| Compliance | ASTM D2500, D5771–D5773, D97, D5853, D5950 |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Dimensions (W×D×H) | 66 × 60 × 80 cm |
| Weight | 60 kg (max 6-test-head configuration) |
| Interface | 12″ integrated high-resolution TFT/LCD touch-panel PC |
| Brand | Ducom |
|---|---|
| Model | DPP |
| Type | Automatic Pour Point Tester |
| Origin | USA |
| Cooling Capacity | Single-stage to –40°C, Dual-stage to –80°C |
| Temperature Range | –80°C to +80°C |
| Resolution | 0.06°C |
| Accuracy | ±0.1°C |
| Repeatability | Compliant with ASTM D5950, ISO 3016, and IP 441 |
| Temperature Sensor | Class A PT100 |
| Display | 12″ TFT/LCD Touchscreen PC |
| Power Supply | 220 V ±15% / 50–60 Hz or 115 V ±15% / 60 Hz |
| Dimensions (W×D×H) | 66 × 60 × 80 cm |
| Weight | 60 kg (max. 6 test heads) |
| Standards Compliance | ASTM D97, D5853, D5950 |
| Brand | Ducom |
|---|---|
| Model | FPT |
| Origin | USA |
| Category | Petroleum Low-Temperature Property Tester |
| Cooling Range | −90 °C to +80 °C |
| Temperature Resolution | 0.01 °C |
| Accuracy | ±0.1 °C |
| Repeatability | Compliant with ASTM D2386, D5972, D7154 and IP 528 |
| Temperature Sensor | Class A PT100 |
| Cooling System | Fluorocarbon-free dual-stage refrigeration |
| Detection Method | Coaxial fiber-optic infrared pulse reflection with mirror-enhanced crystal detection |
| Stirring Mechanism | Motor-driven triple-brass-coil agitator |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Dimensions (W×D×H) | 34 × 60 × 80 cm |
| Weight | 34 kg |
| Standards Compliance | ASTM D2386, D5972, D7154, D852, D1177, D1655 |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | Noac |
| Temperature Range | 0–320 °C |
| Test Range | 225–275 °C |
| Temp. Resolution | 0.01 °C |
| Temp. Accuracy | ±0.1 °C |
| Temp. Repeatability | ASTM D5800-compliant |
| Vacuum Control | –2 mbar (electronic, continuous) |
| Pressure Differential | 20 mmH₂O (auto-regulated) |
| Vacuum Accuracy | ±1% |
| Heating Method | Oil Bath (Method A) or Sample-Controlled (Method B) |
| Compliance | ASTM D5800, IP 42 |
| Dimensions | 40 × 45 × 45 cm (W×D×H) |
| Weight | 22 kg |
| Power | 220 V ±15%, 50–60 Hz or 115 V ±15%, 60 Hz |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | PYNN ERASPEC |
| Sample Volume | 10 mL |
| Measurement Time | 1 min |
| Spectral Range | 4000–400 cm⁻¹ |
| Spectral Resolution | 3000 data points per scan |
| Density Accuracy | ±0.0001 g/cm³ (integrated Anton Paar density module) |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Power Option | 12 V / 4 A |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Connectivity | 3× USB, 1× Ethernet, 1× RS232, LIMS interface |
| Data Storage | ≥2000 test records |
| Display | 6.5″ color touchscreen (Chinese UI) |
| Compliance | ASTM D1655, ASTM D7462, ASTM D7845, ISO 13739, IP 359, DEF STAN 91-91 |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0304 |
| Temperature Range | Ambient to –70 °C (customizable) |
| Compliant Standard | GB/T 510 |
| Cooling System | Imported Refrigeration Compressor |
| Control Accuracy | ±0.5 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | ≤1000 W |
| Operating Environment | ≤30 °C, RH ≤85% |
| Display | LCD with Bilingual (Chinese/English) Interface |
| Timing & Alert | Automated Timing and Audible/Visual Alerts |
| Temperature Calibration | Built-in Offset Correction and Calibration Functionality |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-NQ |
| Price | USD 2,500 (approx.) |
| Temperature Range | −70 °C to +51 °C |
| Compliant Standards | GB/T 510, ISO 3016, ASTM D97, ASTM D6749, SN/T 3017 |
| Detection Method | Automated Pneumatic Pressure Method |
| Sample Volume | 4.5 mL |
| Test Interval | 1 °C |
| Repeatability | ±1 °C |
| Temperature Sensor | Class A PT100 |
| Temperature Accuracy | ±0.1 °C |
| Applied Test Pressure | 310 Pa |
| Cooling Method | Semiconductor-based Thermoelectric Cooling |
| Heating Rate | 1–3 °C/min |
| Cooling Rate | 3–4 °C/min (from ambient to −40 °C), 0.8–1.1 °C/min near pour point |
| Display | 7-inch HD Touchscreen (1024×600) |
| OS | Android-based Embedded System |
| Data Storage | Unlimited (eMMC-dependent) |
| Connectivity | Cloud Upload, USB Export, Thermal Printer Support |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Max Power Consumption | ≤350 W |
| Dimensions (L×W×H) | 440×370×390 mm |
| Net Weight | 19 kg |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | HK-3020ND |
| Price Range | USD 4,200 – 7,000 |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Model | CP610 |
| Temperature Range | –70 °C to +30 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Cooling Capacity | 600 W at 0 °C, 300 W at –40 °C, 100 W at –70 °C |
| Cooling Rate | ~30 °C/h (average) |
| Sample Capacity | 4-position rotating bath |
| Bath Volume | 3.8 L |
| Dimensions | 42 × 53 × 66 cm |
| Weight | ~68 kg |
| Power Supply | 220 V, 10 A, 50/60 Hz, single-phase |
| Compliance | ASTM D97, ASTM D2500, ISO 3016, ISO 2084, IP 15, GB/T 6986, GB/T 3536 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | FK45995 (Mechanical Bath), FK45910 (Dry-Ice Bath) |
| Standards Compliance | ASTM D6371, IP 309, DIN 51428 |
| Temperature Range | –68°C (–90°F) min (mechanical bath) |
| Dimensions (Mechanical) | 89 × 66 × 78.75 cm |
| Weight (Mechanical) | 117.75 kg |
| Dimensions (Dry-Ice) | 30 × 30 cm |
| Weight (Dry-Ice) | 8.6 kg |
| Thermometer Options | ASTM 5C (–38 to +50°C), ASTM 6C (–80 to +20°C) |
| Construction | Pyrex™ test cup, brass sleeve, rubber stopper, plastic insulating ring & gasket, calibrated pipette, 45-µm stainless steel mesh filter |
| Pressure Measurement | Mercury-free U-tube manometer |
| Accessories | K45900 CFPP test assembly, K45920 suction system, K45995 mechanical cold bath, K45910 dry-ice cold bath |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K29795 |
| Price Range | USD 14,000 – 70,000 |
| Temperature Range | Ambient to –73°C (–100°F) |
| Resolution | 0.1°C / 0.1°F |
| Accuracy & Uniformity | Exceeds ASTM D2386 requirements across full operational range |
| Power Supply | 220–240 V, 50 Hz, Single Phase, 10 A |
| Dimensions | 89 × 66 × 78.75 cm |
| Weight | 117.75 kg |
| Cooling Method | Air-cooled, CFC-free refrigeration |
| Display | Dual digital PID controller with selectable °C/°F scale |
| Safety Features | Enhanced enclosure design, transparent observation window with integrated LED illumination, adjustable leveling feet |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | K77000 |
| Price | Upon Request |
| Temperature Range | −105 °C to +50 °C |
| Compliant Standards | ASTM D5771, D5950 |
| Detection Method | Pour Point — Tilting Method |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model Series | 100 / 200 / 300 / 410 |
| Application Domain | Petroleum Low-Temperature Property Testing |
| Compliance Framework | ASTM D2500, D97, D5949, D6371 |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 300/410/2 |
| Standards Compliance | ASTM D1177, D97, D2386, D5901, D5972, D5853, D5950, IP16, IP441, IP528, IP529, ISO 3013, ISO 3016, GB/T 6537, SH/T 0770, GB/T 510 |
| Temperature Range | +80 °C to –80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling System | Dual-stage fluorine-free compressor, min. –85 °C |
| Temperature Sensor | Pt100 Class A |
| Optical Detection | Pulsed IR fiber-optic probe (freeze point) |
| Mechanical Detection | Dual PT100 surface probes + programmable tilt actuator (pour/pour point) |
| Power Supply | 220 V ±15%, 50/60 Hz |
| Dimensions (W×D×H) | 66 × 60 × 80 cm (1-head) |
| Weight | 70 kg (1-head, single-stage), 80 kg (1-head, dual-stage), 90 kg (2-head, single-stage), 100 kg (2-head, dual-stage) |
| Software | LabLink v5.x (Windows 2000/XP/Vista), supports up to 10 analysis heads, LIMS-compatible, 21 CFR Part 11-ready audit trail, Excel-exportable data format (.csv/.xls), >60,000 result storage capacity |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 410 |
| Freeze Point Range | +80 °C to –100 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D1177, D2386, D5901, D5972, D1655 |
| Measurement Principle | Coaxial pulsed IR spectroscopy with fiber-optic probe and reflective optical path |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 100 / D2500 |
| Temperature Range | +80 °C to –80 °C |
| Cooling System | Single-stage or dual-stage compressor |
| Temperature Sensor | Pt100 Class A |
| Optical Detection | Pulsed IR fiber-optic probe with silver-coated sample tube bottom |
| Temp. Resolution | 0.06 °C |
| Temp. Accuracy | ±0.1 °C |
| Compliance | ASTM D2500, D5771, D5772, D5773 |
| Software | LabLink (Windows-compatible, multi-head control up to 10 units) |
| Data Storage | >60,000 assays, Excel-exportable, LIMS-integrated |
| Dimensions (1-head) | 66 × 60 × 80 cm |
| Weight (1-head, single-stage) | 70 kg |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 1300 |
| Temperature Range | +80 °C to –80 °C |
| Cooling System | Single-stage or dual-stage compressor (–40 °C or –85 °C min) |
| Temperature Sensor | PT100 Class A |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D2500, D5771–D5773, D97, D5950, D5853 |
| Optical Detection | Pulsed IR fiber-optic probe for cloud point |
| Mechanical Detection | Dual PT100 surface probes + motorized tilt arm for pour point |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 300 |
| Temperature Range | +80 °C to –80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D97, D5950, D5853 |
| Detection Method | Dual PT100 surface probes with motorized sample tube tilting |
| Cooling System | Single-stage or dual-stage compressor options |
| Test Heads | 1 or 2 independent stations |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 300/2 |
| Temperature Range | +80 °C to –80 °C |
| Cooling System | Dual-stage compressor |
| Temperature Sensor | PT100 Class A |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Standards Compliance | ASTM D97, D5950, D5853 |
| Sample Capacity | Dual PT100 surface probes, standardized test tube per ASTM/IP/ISO |
| Software | LabLink (Windows-compatible), supports up to 10 analysis heads, LIMS- and Excel-compatible data export, audit-trail-capable calibration logging |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 410/2 |
| Cooling Capacity | −85 °C (dual-stage compressor) |
| Temperature Range | +80 °C to −100 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D1177, D2386, D5901, D5972, D1655 |
| Detection Principle | Optical crystallization detection via coaxial IR fiber-optic probe and polished mirror surface |
| Temperature Sensor | PT100 Class A |
| Stirring System | Miniature motor-driven mechanical stirrer |
| Cooling System | Hermetic dual-stage refrigeration (R513A/R1234ze, fluorine-free) |
| Power Supply | 220 V ±15 %, 50/60 Hz |
| Safety Certifications | CE, integrated pressure controllers, thermal cut-offs, compressor overload protection |
| Software | LabLink v5.x (Windows 10/11 compatible), supports up to 10 analysis heads, 21 CFR Part 11–ready audit trail, LIMS integration, Excel-exportable data format (.csv, .xlsx) |
| Brand | Linetroic |
|---|---|
| Origin | Switzerland |
| Model | 200 CFPP |
| Compliance | ASTM D97, D5950, D5853 |
| Temperature Range | +80 °C to –90 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling System | Single-stage or dual-stage compressor (–40 °C or –85 °C base cooling) |
| Sensor Type | PT100 Class A platinum resistance thermometers |
| Sample Capacity | Standardized test jar per ASTM/IP/ISO specifications |
| Brand | Linetronic |
|---|---|
| Origin | Switzerland |
| Model | 300/2 |
| Temperature Range | +80 °C to –80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling System | Dual-stage compressor (–85 °C min) or single-stage compressor (–40 °C min) |
| Temperature Sensor | PT100 Class A |
| Detection Method | Coaxial fiber-optic IR pulse reflection with mirror-based crystallization monitoring |
| Compliance | ASTM D1177, D2386, D5901, D5972, D1655 |
| Software | LabLink v.x (Windows 2000/XP/Vista), supports up to 10 analysis heads, LIMS-compatible, 21 CFR Part 11-ready audit trail capability |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CFPP |
| Price Range | USD 13,500 – 67,500 (FOB Rotterdam) |
| Test Range | −105 °C to +65 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Sensor | PT100 Class A |
| Temperature Resolution | 0.1 °C |
| Vacuum Control | Microprocessor-controlled, programmable fixed/dynamic vacuum (2.0 ± 0.1 kPa) |
| Cooling System | Integrated solid-state thermoelectric bath (no external chiller required), min. temp. −105 °C |
| Cooling Profile | Programmable linear and stepwise ramping |
| Sample Detection | Triple-point laser level sensor |
| Filtration Mesh | 45 µm stainless steel |
| Pipette Volume | 20 mL |
| Timing Resolution | >0.1 s (digital display) |
| Data Storage Capacity | 200 test records |
| Cleaning Protocol | Fully automated dual-solvent wash cycle |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 150 W |
| Dimensions (W×D×H) | 16 cm × 59 cm × 35 cm |
| Weight | 25 kg |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Model | CPPP |
| Temperature Bath Range | +65 °C to −105 °C |
| Cooling Rate | 1–60 °C/h (linear or stepwise) |
| Detection Method | High-resolution digital imaging with real-time video analysis |
| Temperature Sensor | Removable Pt100 probe with embedded calibration data and ID |
| Power Supply to Test Head | Wireless Powercast® technology |
| Motion Control | Microprocessor-driven stepper motor for precise tube lifting and tilting |
| Compliance | ASTM D97, D2500, D5853, D5771, D6892 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FT |
| Quotation | Upon Request |
| Temperature Range | –25 °C to 80 °C (standard) |
| Pressure Range | 10 bar (145 psi), 200 bar (2,900 psi), or 700 bar (10,000 psi) |
| Stirring Speed | 0–1,000 rpm |
| Titration Flow Rate | 0.3–30 mL/min |
| Optical Detection Sensitivity | 0.005 lux |
| Probe Interface | Threaded in-line mounting (NPT/BSP options available) |
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-0248A |
| Origin | Shaanxi, China |
| Manufacturer | Yes |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Input Power | <1250 W |
| Cooling Range | Ambient to –40 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | 400 W |
| Refrigerant | Anhydrous Ethanol |
| Filtration Pressure | 1961 Pa (200 mmH₂O) |
| Filter Mesh | 363 mesh (≈40 µm nominal aperture) |
| Standard Compliance | SH/T 0248 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-0248B |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Input Power | <1250 W |
| Cooling Bath Temperature Range | Ambient to –40 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | 400 W |
| Refrigerant | Anhydrous Ethanol |
| Refrigeration System | Cascade Compressor-Based |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-3535A |
| Input Power | < 800 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | Ambient to –35 °C |
| Temperature Control Accuracy | ±1 °C |
| Cooling Time | ≤ 100 min |
| Cold Bath Dimensions | 200 × 90 × 120 mm |
| Bath Configuration | Dual-Position Single Bath (1 pour point station + 1 cloud point station) |
| Compliance | GB/T 3535, GB/T 6986 |