Empowering Scientific Discovery

Platinum Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelQ6 NEWTON
Instrument TypeBenchtop
Excitation MethodSpark
Detector TypePhotomultiplier Tube (PMT)
Focal Length800 mm
Grating Groove Density3600 lines/mm
Wavelength Range120–200 nm
Number of Channels128
Argon Consumption2–4 L/min (during analysis)
Detector Pixel Count / Pixel Size3880 pixels per single detector block
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelQ4 POLO
Instrument TypeBenchtop
Excitation MethodSpark
Detector TypePhotomultiplier Tube (PMT)
Focal Length800 mm
Grating Groove Density3600 lines/mm
Wavelength Range120–785 nm (dual optical paths: 130–785 nm total coverage)
Number of Channels128
Optical SystemMultiVision™ with argon-purged vacuum UV path
Temperature CompensationAAC™ Active Ambient Compensation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQ4 TASMAN
Instrument TypeBenchtop
Excitation MethodSpark
Detector TypeDual Detector (PMT + CCD)
Focal Length800 mm
Grating Groove Density3600 lines/mm
Wavelength Range130–800 nm
Number of Channels128
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQ4 TASMAN
Instrument TypeDesktop
Excitation MethodSpark
Detector TypeDual Detector (PMT + CCD)
Focal Length800 mm
Grating Groove Density3600 lines/mm
Wavelength Range130–800 nm
Number of Channels128
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelQ8 MAGELLAN
Instrument TypeBenchtop
Excitation MethodSpark
Detector TypePhotomultiplier Tube (PMT)
Focal Length1000 mm
Grating Groove Density3600 lines/mm
Wavelength Range110–800 nm
Number of Channels128
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeBenchtop
Excitation SourceSpark
Detector ConfigurationDual Detector (PMT + CCD)
Focal Length400 mm
Grating Groove Density3600 lines/mm
Wavelength Range170–685 nm
Number of Analytical Channels32
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeBenchtop
Excitation MethodSpark
Detector TypeDual Detector (PMT + CCD)
Focal Length800 mm
Grating Groove Density3600 lines/mm
Wavelength Range130–800 nm
Number of Channels128
Argon Consumption2–4 L/min (during analysis)
Detector Pixel Count / Pixel Size3880 pixels per CCD chip
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeBenchtop
Excitation MethodSpark
Detector TypePhotomultiplier Tube (PMT)
Focal Length1000 mm
Grating Groove Density3600 lines/mm
Wavelength Range110–800 nm
Number of Channels128
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0